Compact instrument for fluorescence image-guided surgery.

Abstract:

:Fluorescence image-guided surgery (FIGS) is an emerging technique in oncology, neurology, and cardiology. To adapt intraoperative imaging for various surgical applications, increasingly flexible and compact FIGS instruments are necessary. We present a compact, portable FIGS system and demonstrate its use in cardiovascular mapping in a preclinical model of myocardial ischemia. Our system uses fiber optic delivery of laser diode excitation, custom optics with high collection efficiency, and compact consumer-grade cameras as a low-cost and compact alternative to open surgical FIGS systems. Dramatic size and weight reduction increases flexibility and access, and allows for handheld use or unobtrusive positioning over the surgical field.

journal_name

J Biomed Opt

authors

Wang X,Bhaumik S,Li Q,Staudinger VP,Yazdanfar S

doi

10.1117/1.3378128

subject

Has Abstract

pub_date

2010-03-01 00:00:00

pages

020509

issue

2

eissn

1083-3668

issn

1560-2281

journal_volume

15

pub_type

杂志文章
  • Measurement of ocular anterior segment dimension and wavefront aberration simultaneously during accommodation.

    abstract::In order to understand the relationship between accommodation and vision quality, a custom-built ultra-long scan depth spectral domain optical coherence tomography (UL-SDOCT) and a Shack-Hartmann wavefront sensor (HSWFS) were combined. The resolution and scan depth of UL-SDOCT are 6 μm and 15.6 mm, respectively, which...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.17.12.120501

    authors: Shi G,Wang Y,Yuan Y,Wei L,Lv F,Zhang Y

    更新日期:2012-12-01 00:00:00

  • Logarithmic intensity compression in fluorescence guided surgery applications.

    abstract::The use of fluorescence video imaging to guide surgery is rapidly expanding, and improvements in camera readout dynamic range have not matched display capabilities. Logarithmic intensity compression is a fast, single-step mapping technique that can map the useable dynamic range of high-bit fluorescence images onto the...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.8.080504

    authors: DSouza AV,Lin H,Gunn J,Pogue BW

    更新日期:2015-08-01 00:00:00

  • Quality analysis of in vivo near-infrared fluorescence and conventional gamma images acquired using a dual-labeled tumor-targeting probe.

    abstract::The cyclic peptide, cyclopentapeptide cyclo(lys-Arg-Gly-Asp-phe) (c(KRGDf)), which is known to target alpha(v)beta3 integrin, is dual-labeled with a radiotracer, (111)indium, for gamma scintigraphy as well as with a near-infrared dye, IRDye800, for continuous-wave (cw) imaging of alpha(v)beta3 positive human M21 melan...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2114748

    authors: Houston JP,Ke S,Wang W,Li C,Sevick-Muraca EM

    更新日期:2005-09-01 00:00:00

  • Characterization of retinal biomechanical properties using Brillouin microscopy.

    abstract:SIGNIFICANCE:The retina is critical for vision, and several diseases may alter its biomechanical properties. However, assessing the biomechanical properties of the retina nondestructively is a challenge due to its fragile nature and location within the eye globe. Advancements in Brillouin spectroscopy have provided the...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.9.090502

    authors: Ambekar YS,Singh M,Scarcelli G,Rueda EM,Hall BM,Poché RA,Larin KV

    更新日期:2020-09-01 00:00:00

  • Computer model to investigate the effect of eye movements on retinal heating during long-duration fixation on a laser source.

    abstract::A computer simulation called RHME (Retinal Heating in Moving Eye) is developed to simulate the heating pattern that occurs in the retina during a long-duration exposure to a continuous wave laser beam. The simulation takes into account eye movements that occur during a deliberate fixation. Due to the rapid (millisecon...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1783355

    authors: Lund BJ

    更新日期:2004-09-01 00:00:00

  • New cross-talk measure of near-infrared spectroscopy and its application to wavelength combination optimization.

    abstract::In near-infrared spectroscopy, concentration changes in oxygenated and deoxygenated hemoglobin are calculated from the changes in the attenuation of the measurement light. This is done by solving a linear equation based on the modified Lambert-Beer law. To solve this equation, we need to know the partial optical pathl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3147402

    authors: Umeyama S,Yamada T

    更新日期:2009-05-01 00:00:00

  • Retinal response of Macaca mulatta to picosecond laser pulses of varying energy and spot size.

    abstract::We investigate the relationship between the laser beam at the retina (spot size) and the extent of retinal injury from single ultrashort laser pulses. From previous studies it is believed that the retinal effect of single 3-ps laser pulses should vary in extent and location, depending on the occurrence of laser-induce...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1805554

    authors: Roach WP,Cain CP,Narayan DG,Noojin GD,Boppart SA,Birngruber R,Fujimoto JG,Toth CA

    更新日期:2004-11-01 00:00:00

  • Quantitative detection of chemical compounds in human hair with coherent anti-Stokes Raman scattering microscopy.

    abstract::Coherent anti-Stokes Raman scattering (CARS) microscopy is used to determine the distribution and concentration of selected compounds in intact human hair. By generating images based on ratiometric CARS contrast, quantitative concentration maps of both water and externally applied d-glycine are produced in the cortex ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3184444

    authors: Zimmerley M,Lin CY,Oertel DC,Marsh JM,Ward JL,Potma EO

    更新日期:2009-07-01 00:00:00

  • Amending of fluorescence sensor signal localization in human skin by matching of the refractive index.

    abstract::Fluorescence diagnostic techniques are notable amongst many other optical methods because they offer high sensitivity and noninvasive measurement of tissue properties. However, a combination of multiple scattering and physical heterogeneity of biological tissues hampers interpretation of the fluorescence measurements....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1645796

    authors: Churmakov DY,Meglinski IV,Greenhalgh DA

    更新日期:2004-03-01 00:00:00

  • Curved array photoacoustic tomographic system for small animal imaging.

    abstract::We present systematic characterization of a photoacoustic imaging system optimized for rapid, high-resolution tomographic imaging of small animals. The system is based on a 128-element ultrasonic transducer array with a 5-MHz center frequency and 80% bandwidth shaped to a quarter circle of 25 mm radius. A 16-channel d...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2907157

    authors: Gamelin J,Aguirre A,Maurudis A,Huang F,Castillo D,Wang LV,Zhu Q

    更新日期:2008-03-01 00:00:00

  • Fluorescence confocal endomicroscopy of the cervix: pilot study on the potential and limitations for clinical implementation.

    abstract::Current diagnostic capabilities and limitations of fluorescence endomicroscopy in the cervix are assessed by qualitative and quantitative image analysis. Four cervical tissue types are investigated: normal columnar epithelium, normal and precancerous squamous epithelium, and stromal tissue. This study focuses on the p...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.126011

    authors: Schlosser C,Bodenschatz N,Lam S,Lee M,McAlpine JN,Miller DM,Van Niekerk DJ,Follen M,Guillaud M,MacAulay CE,Lane PM

    更新日期:2016-12-01 00:00:00

  • Myocardial tissue oxygenation estimated with calibrated diffuse reflectance spectroscopy during coronary artery bypass grafting.

    abstract::We present a study using a method able to assess tissue oxygenation, taking into account the absorption and the level of scattering in myocardial tissue using a calibrated fiber optic probe. With this method, interindividual comparisons of oxygenation can be made despite varying tissue optical properties during corona...

    journal_title:Journal of biomedical optics

    pub_type: 临床试验,杂志文章

    doi:10.1117/1.2976433

    authors: Häggblad E,Lindbergh T,Karlsson MG,Casimir-Ahn H,Salerud EG,Strömberg T

    更新日期:2008-09-01 00:00:00

  • Motion-compensated noncontact imaging photoplethysmography to monitor cardiorespiratory status during exercise.

    abstract::With the advance of computer and photonics technology, imaging photoplethysmography [(PPG), iPPG] can provide comfortable and comprehensive assessment over a wide range of anatomical locations. However, motion artifact is a major drawback in current iPPG systems, particularly in the context of clinical assessment. To ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3602852

    authors: Sun Y,Hu S,Azorin-Peris V,Greenwald S,Chambers J,Zhu Y

    更新日期:2011-07-01 00:00:00

  • Polarization-interferometry-based wavelength-interrogation surface plasmon resonance imager for analysis of microarrays.

    abstract::Polarization interferometry (PI) techniques, which are able to improve surface plasmon resonance (SPR) sensing performance and reduce restrictions on allowable parameters of SPR-supporting metal films, have been experimentally realized only in SPR sensors using monochromatic light as a source. Wavelength-interrogation...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.3.036002

    authors: Liu Z,Liu L,Wang X,Shi H,Chong X,Ma S,Ji Y,Guo J,Ma H,He Y

    更新日期:2012-03-01 00:00:00

  • Comparison of laser and diode sources for acceleration of in vitro wound healing by low-level light therapy.

    abstract::Low-level light therapy has been shown to improve in vitro wound healing. However, well-defined parameters of different light sources for this therapy are lacking. The goal of this study was (1) to determine if the wavelengths tested are effective for in vitro wound healing and (2) to compare a laser and a light-emitt...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.3.038001

    authors: Spitler R,Berns MW

    更新日期:2014-03-01 00:00:00

  • Measurement and imaging of birefringent properties of the human cornea with phase-resolved, polarization-sensitive optical coherence tomography.

    abstract::Optical coherence tomography (OCT) is an emerging technology for high-resolution, noncontact imaging of transparent and scattering media. Polarization-sensitive optical coherence tomography (PS-OCT) is a functional extension of OCT that can image birefringent properties of a biological sample. PS-OCT was used to measu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1629308

    authors: Götzinger E,Pircher M,Sticker M,Fercher AF,Hitzenberger CK

    更新日期:2004-01-01 00:00:00

  • Determination of optical scattering properties in turbid media using Mueller matrix imaging.

    abstract::A need exists for the continued development of diagnostic tools and methods capable of distinguishing and characterizing slight differences in the optical properties of tissues. We present a method to estimate the scattering coefficient contribution as a function of particle size in complex mixtures of polystyrene sph...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2363347

    authors: Cameron BD,Li Y,Nezhuvingal A

    更新日期:2006-09-01 00:00:00

  • Angle-resolved Mueller matrix study of light scattering by B-cells at three wavelengths of 442, 633, and 850 nm.

    abstract::Angle-resolved signals of polarized light scattered by biological cells provide rich information on cell morphology. Quantitative study of these signals can lead to new methods to develop and improve high-throughput instrumentation for cell probing such as scattering-based flow cytometry. We employ a goniometer system...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2749730

    authors: Ding H,Lu JQ,Brock RS,McConnell TJ,Ojeda JF,Jacobs KM,Hu XH

    更新日期:2007-05-01 00:00:00

  • Photoacoustic needle: minimally invasive guidance to biopsy.

    abstract::We introduce a needle probe based on photoacoustics (PA) to extend the scope of optical needle methods in guiding biopsies. Pulsed light is coupled to an optical fiber in a needle to be inserted in tissue, and PA signals are detected using an ultrasound imager used for needle guidance. This PA needle samples large vol...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.7.070502

    authors: Piras D,Grijsen C,Schütte P,Steenbergen W,Manohar S

    更新日期:2013-07-01 00:00:00

  • Average-power mediated ultrafast laser osteotomy using a mode-locked Nd:YVO4 laser oscillator.

    abstract::By using a novel temporal characterization technique, we determined that a threshold average laser power of 160 mW is required to drill through a 0.75-mm-thick cortical bone for a Nd:YVO(4) mode-locked laser oscillator with a peak intensity of 1.3 GWcm(2). The ablation mechanism is identified as average-power induced ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2821149

    authors: Lee YM,Tu RY,Chiang AC,Huang YC

    更新日期:2007-11-01 00:00:00

  • Noninvasive assessment of diabetic foot ulcers with diffuse photon density wave methodology: pilot human study.

    abstract::A pilot human study is conducted to evaluate the potential of using diffuse photon density wave (DPDW) methodology at near-infrared (NIR) wavelengths (685 to 830 nm) to monitor changes in tissue hemoglobin concentration in diabetic foot ulcers. Hemoglobin concentration is measured by DPDW in 12 human wounds for a peri...

    journal_title:Journal of biomedical optics

    pub_type: 临床试验,杂志文章

    doi:10.1117/1.3275467

    authors: Papazoglou ES,Neidrauer M,Zubkov L,Weingarten MS,Pourrezaei K

    更新日期:2009-11-01 00:00:00

  • Use of laser tweezers to analyze sperm motility and mitochondrial membrane potential.

    abstract::We combine laser tweezers with custom computer tracking software and robotics to analyze the motility [swimming speed, VCL (curvilinear velocity), and swimming force in terms of escape laser power (Pesc)] and energetics [mitochondrial membrane potential (MP)] of individual sperm. Domestic dog sperm are labeled with a ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2839051

    authors: Nascimento JM,Shi LZ,Chandsawangbhuwana C,Tam J,Durrant B,Botvinick EL,Berns MW

    更新日期:2008-01-01 00:00:00

  • Monte-Carlo-based model for the extraction of intrinsic fluorescence from turbid media.

    abstract::A Monte-Carlo-based model of fluorescence is developed that is capable of extracting the intrinsic fluorescence properties of tissue, which are independent of the absorption and scattering properties of tissue. This model is flexible in its applicability to different illumination-collection geometries and is also vali...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2907161

    authors: Palmer GM,Ramanujam N

    更新日期:2008-03-01 00:00:00

  • Characterization of novel microsphere chain fiber optic tips for potential use in ophthalmic laser surgery.

    abstract::Ophthalmic surgery may benefit from use of more precise fiber delivery systems during laser surgery. Some current ophthalmic surgical techniques rely on tedious mechanical dissection of tissue layers. In this study, chains of sapphire microspheres integrated into a hollow waveguide distal tip are used for erbium:YAG l...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.6.068004

    authors: Hutchens TC,Darafsheh A,Fardad A,Antoszyk AN,Ying HS,Astratov VN,Fried NM

    更新日期:2012-06-01 00:00:00

  • Time-resolved imaging of optical coefficients through murine chest cavities.

    abstract::As small animal optical imaging and tomography are gaining popularity for interrogating functional and molecular events in vivo, it becomes increasingly necessary to gain knowledge of the optical properties of the species investigated to better understand and describe photon propagation through their tissues. To achie...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2400702

    authors: Niedre MJ,Turner GM,Ntziachristos V

    更新日期:2006-11-01 00:00:00

  • Detection of enzyme activity in orthotopic murine breast cancer by fluorescence lifetime imaging using a fluorescence resonance energy transfer-based molecular probe.

    abstract::Cancer-related enzyme activity can be detected noninvasively using activatable fluorescent molecular probes. In contrast to "always-on" fluorescent molecular probes, activatable probes are relatively nonfluorescent at the time of administration due to intramolecular fluorescence resonance energy transfer (FRET). Enzym...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3594153

    authors: Solomon M,Guo K,Sudlow GP,Berezin MY,Edwards WB,Achilefu S,Akers WJ

    更新日期:2011-06-01 00:00:00

  • Quantitative microscopy and nanoscopy of sickle red blood cells performed by wide field digital interferometry.

    abstract::We have applied wide-field digital interferometry (WFDI) to examine the morphology and dynamics of live red blood cells (RBCs) from individuals who suffer from sickle cell anemia (SCA), a genetic disorder that affects the structure and mechanical properties of RBCs. WFDI is a noncontact, label-free optical microscopy ...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3556717

    authors: Shaked NT,Satterwhite LL,Telen MJ,Truskey GA,Wax A

    更新日期:2011-03-01 00:00:00

  • Swept-source optical coherence tomography powered by a 1.3-μm vertical cavity surface emitting laser enables 2.3-mm-deep brain imaging in mice in vivo.

    abstract::We report noninvasive, in vivo optical imaging deep within a mouse brain by swept-source optical coherence tomography (SS-OCT), enabled by a 1.3-μm vertical cavity surface emitting laser (VCSEL). VCSEL SS-OCT offers a constant signal sensitivity of 105 dB throughout an entire depth of 4.25 mm in air, ensuring an exten...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.10.106004

    authors: Choi WJ,Wang RK

    更新日期:2015-10-01 00:00:00

  • Real-time full-field photoacoustic imaging using an ultrasonic camera.

    abstract::A photoacoustic imaging system that incorporates a commercial ultrasonic camera for real-time imaging of two-dimensional (2-D) projection planes in tissue at video rate (30 Hz) is presented. The system uses a Q-switched frequency-doubled Nd:YAG pulsed laser for photoacoustic generation. The ultrasonic camera consists ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3420079

    authors: Balogun O,Regez B,Zhang HF,Krishnaswamy S

    更新日期:2010-03-01 00:00:00

  • Micro-Raman spectroscopy study of cancerous and normal nasopharyngeal tissues.

    abstract::The capabilities of micro-Raman spectroscopy for differentiating normal and malignant nasopharyngeal tissues were evaluated. Raman scattering signals were acquired from 22 normal and 52 malignant nasopharyngeal tissue samples. Distinctive spectral differences in Raman spectra between normal and malignant nasopharyngea...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.2.027003

    authors: Li Y,Pan J,Chen G,Li C,Lin S,Shao Y,Feng S,Huang Z,Xie S,Zeng H,Chen R

    更新日期:2013-02-01 00:00:00