Real-time full-field photoacoustic imaging using an ultrasonic camera.

Abstract:

:A photoacoustic imaging system that incorporates a commercial ultrasonic camera for real-time imaging of two-dimensional (2-D) projection planes in tissue at video rate (30 Hz) is presented. The system uses a Q-switched frequency-doubled Nd:YAG pulsed laser for photoacoustic generation. The ultrasonic camera consists of a 2-D 12 x 12 mm CCD chip with 120 x 120 piezoelectric sensing elements used for detecting the photoacoustic pressure distribution radiated from the target. An ultrasonic lens system is placed in front of the chip to collect the incoming photoacoustic waves, providing the ability for focusing and imaging at different depths. Compared with other existing photoacoustic imaging techniques, the camera-based system is attractive because it is relatively inexpensive and compact, and it can be tailored for real-time clinical imaging applications. Experimental results detailing the real-time photoacoustic imaging of rubber strings and buried absorbing targets in chicken breast tissue are presented, and the spatial resolution of the system is quantified.

journal_name

J Biomed Opt

authors

Balogun O,Regez B,Zhang HF,Krishnaswamy S

doi

10.1117/1.3420079

subject

Has Abstract

pub_date

2010-03-01 00:00:00

pages

021318

issue

2

eissn

1083-3668

issn

1560-2281

journal_volume

15

pub_type

杂志文章
  • Surface-enhanced Raman spectroscopy of tears: toward a diagnostic tool for neurodegenerative disease identification.

    abstract:SIGNIFICANCE:A noninvasive method based on surface-enhanced Raman spectroscopy (SERS) of tears was proposed as a support for diagnosing neurodegenerative pathologies, including different forms of dementia and Alzheimer's disease (AD). In this field, timely and reliable discrimination and diagnosis are critical aspects ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.8.087002

    authors: Cennamo G,Montorio D,Morra VB,Criscuolo C,Lanzillo R,Salvatore E,Camerlingo C,Lisitskiy M,Delfino I,Portaccio M,Lepore M

    更新日期:2020-08-01 00:00:00

  • "Seeing" electroencephalogram through the skull: imaging prefrontal cortex with fast optical signal.

    abstract::Near-infrared spectroscopy is a novel imaging technique potentially sensitive to both brain hemodynamics (slow signal) and neuronal activity (fast optical signal, FOS). The big challenge of measuring FOS noninvasively lies in the presumably low signal-to-noise ratio. Thus, detectability of the FOS has been controversi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3505007

    authors: Medvedev AV,Kainerstorfer JM,Borisov SV,Gandjbakhche AH,Vanmeter J

    更新日期:2010-11-01 00:00:00

  • Design of synchrotron light source and its beamline dedicated to dual-energy x-ray computed tomography.

    abstract::A synchrotron light source dedicated to medical applications has been designed at National Institute of Radiological Sciences. The storage ring, with circumference of 80 m, is designed for acceleration of 2.3 GeV and a stored current of 420 mA. It is equipped with two multipole wigglers to produce sufficient photon fl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1383062

    authors: Torikoshi M,Tsunoo T,Endo M,Noda K,Kumada M,Yamada S,Soga F,Hyodo K

    更新日期:2001-07-01 00:00:00

  • Study on application of optical clearing technique in skin diseases.

    abstract::So far, the study of the optical clearing is almost always about healthy tissue. However, the ultimate goal is to detect diseases for clinical application. Optical clearing on diseased skins is explored. The effect is evaluated by applying a combined liquid paraffin and glycerol mixed solution on several kinds of dise...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.11.115003

    authors: Shan H,Liang Y,Wang J,Li Y

    更新日期:2012-11-01 00:00:00

  • No-core fiber-based highly sensitive optical fiber pH sensor.

    abstract::The present work describes the fabrication and characterization of an optical fiber pH sensor using a sol–gel technique. The sensing head configuration is incorporated using a short section of no-core fiber, coated with tetraethyl orthosilicate and spliced at the end of a single mode fiber with a bulge. Different type...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.5.057001

    authors: Bhardwaj V,Pathak AK,Singh VK

    更新日期:2017-05-01 00:00:00

  • Quantitative real-time optical imaging of the tissue metabolic rate of oxygen consumption.

    abstract::The tissue metabolic rate of oxygen consumption (tMRO2) is a clinically relevant marker for a number of pathologies including cancer and arterial occlusive disease. We present and validate a noncontact method for quantitatively mapping tMRO2 over a wide, scalable field of view at 16  frames  /  s. We achieve this by d...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.3.036013

    authors: Ghijsen M,Lentsch GR,Gioux S,Brenner M,Durkin AJ,Choi B,Tromberg BJ

    更新日期:2018-03-01 00:00:00

  • Macromolecular diffusion in the extracellular matrix measured by fluorescence correlation spectroscopy.

    abstract::Diffusion of therapeutic macromolecules through the extracellular matrix of tumor tissue is a crucial step in drug delivery. We use fluorescence correlation spectroscopy (FCS) to measure diffusion of IgG (150 kDa) and dextrans (155 kDa and 2 MDa) in solution, 5% gelatin hydrogel, and multicellular spheroids. Gel and s...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2982530

    authors: Reitan NK,Juthajan A,Lindmo T,de Lange Davies C

    更新日期:2008-09-01 00:00:00

  • Quantitative mapping of collagen fiber alignment in thick tissue samples using transmission polarized-light microscopy.

    abstract::Immersion optical clearing makes it possible to use transmission polarized-light microscopy for characterization of thick (200 to 2000  μm) layers of biological tissues. We discuss polarization properties of thick samples in the context of the problem of characterization of collagen fiber alignment in connective tissu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.7.071111

    authors: Yakovlev DD,Shvachkina ME,Sherman MM,Spivak AV,Pravdin AB,Yakovlev DA

    更新日期:2016-07-01 00:00:00

  • Combined anatomical optical coherence tomography and intraluminal pressure reveal viscoelasticity of the in vivo airway.

    abstract::It is hypothesized that the local, viscoelastic (time-dependent) properties of the airway are important to accurately model and ultimately predict dynamic airway collapse in airway obstruction. Toward this end, we present a portable, endoscopic, swept-source anatomical optical coherence tomography (aOCT) system combin...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.23.10.100501

    authors: Balakrishnan S,Bu R,Iftimia N,Price H,Zdanski C,Oldenburg AL

    更新日期:2018-10-01 00:00:00

  • Label-free separation of human embryonic stem cells and their differentiating progenies by phasor fluorescence lifetime microscopy.

    abstract::We develop a label-free optical technique to image and discriminate undifferentiated human embryonic stem cells (hESCs) from their differentiating progenies in vitro. Using intrinsic cellular fluorophores, we perform fluorescence lifetime microscopy (FLIM) and phasor analysis to obtain hESC metabolic signatures. We id...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.4.046012

    authors: Stringari C,Sierra R,Donovan PJ,Gratton E

    更新日期:2012-04-01 00:00:00

  • Monitoring the reduced scattering coefficient of bone tissues on the trajectory of pedicle screw placement using near-infrared spectroscopy.

    abstract::Pedicle screw (PS) fixation has been widely used for spine diseases. Scientists and clinicians employ several approaches to navigate PS during operation. We have demonstrated the feasibility of monitoring the reduced scattering coefficient (μ's) on the trajectory of PS using near-infrared spectroscopy (NIRS). To perfo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.117002

    authors: Liu Y,Wang Y,Qian Z,Zhao J,Cao X,Li W

    更新日期:2014-01-01 00:00:00

  • Resolution in the ApoTome and the confocal laser scanning microscope: comparison.

    abstract::The essential feature of the confocal laser scanning microscope (cLSM) is the generation of optical sections by the removal of out-of-focus light. About ten years ago, structured illumination microscopy (SIM) was introduced as an alternative method for obtaining optical sections from biological specimens. Here we comp...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3083439

    authors: Weigel A,Schild D,Zeug A

    更新日期:2009-01-01 00:00:00

  • Multi-reference global registration of individual A-lines in adaptive optics optical coherence tomography retinal images.

    abstract:SIGNIFICANCE:Adaptive optics optical coherence tomography (AO-OCT) technology enables non-invasive, high-resolution three-dimensional (3D) imaging of the retina and promises earlier detection of ocular disease. However, AO-OCT data are corrupted by eye-movement artifacts that must be removed in post-processing, a proce...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.26.1.016001

    authors: Kurokawa K,Crowell JA,Do N,Lee JJ,Miller DT

    更新日期:2021-01-01 00:00:00

  • Photoacoustic microscopy of blood pulse wave.

    abstract::Blood pulse wave velocity (PWV) is an important physiological parameter that characterizes vascular stiffness. In this letter, we present electrocardiogram-synchronized, photoacoustic microscopy for noninvasive quantification of the PWV in the peripheral vessels of living mice. Interestingly, blood pulse wave-induced ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.070504

    authors: Yeh C,Hu S,Maslov K,Wang LV

    更新日期:2012-07-01 00:00:00

  • Swept-source optical coherence tomography powered by a 1.3-μm vertical cavity surface emitting laser enables 2.3-mm-deep brain imaging in mice in vivo.

    abstract::We report noninvasive, in vivo optical imaging deep within a mouse brain by swept-source optical coherence tomography (SS-OCT), enabled by a 1.3-μm vertical cavity surface emitting laser (VCSEL). VCSEL SS-OCT offers a constant signal sensitivity of 105 dB throughout an entire depth of 4.25 mm in air, ensuring an exten...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.10.106004

    authors: Choi WJ,Wang RK

    更新日期:2015-10-01 00:00:00

  • Blood oxygen flux estimation with a combined photoacoustic and high-frequency ultrasound microscopy system: a phantom study.

    abstract::The metabolic rate of oxygen consumption, an important indicator of tissue metabolism, can be expressed as the change of net blood oxygen flux into and out of a tissue region per 100 g of tissue. In this work, we propose a photoacoustic and Doppler ultrasound method for imaging local blood oxygen flux of a single vess...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.3.036012

    authors: Jiang Y,Forbrich A,Harrison T,Zemp RJ

    更新日期:2012-03-01 00:00:00

  • Nile Red derivatives enable improved ratiometric imaging for nerve-specific contrast.

    abstract::Surgical nerve damage due to difficulty with identification remains a major risk for postsurgical complications and decreased quality of life. Fluorescence-guided surgery offers a means to specifically highlight tissues of interest such as nerves and a number of fluorescence-guided surgical systems are in clinical tri...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.7.076002

    authors: Korber J,Barth C,Gibbs S

    更新日期:2018-07-01 00:00:00

  • Diagnosis of oral submucous fibrosis with optical coherence tomography.

    abstract::The epithelium (EP) thickness and the standard deviation (SD) of A-mode scan intensity in the laminar propria (LP) layer are used as effective indicators for the diagnosis of oral submucous fibrosis (OSF) based on the noninvasive clinical scanning of a swept-source optical coherence tomography (OCT) system of approxim...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3233653

    authors: Lee CK,Tsai MT,Lee HC,Chen HM,Chiang CP,Wang YM,Yang CC

    更新日期:2009-09-01 00:00:00

  • Minimizing Thermal Damage in Corneal Ablation with Short Pulse Mid-infrared Lasers.

    abstract::Photospallation is proposed as the primary mechanism behind our recent animal studies involving corneal ablation by nanosecond-pulse mid-IR laser beams. Following a brief summary of earlier work directed to refractive procedures in the mid-IR, a preliminary analysis is presented, based on simple one-dimensional models...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429958

    authors: Hoffman HJ,Telfair WB

    更新日期:1999-10-01 00:00:00

  • Acoustic attenuation compensation in photoacoustic tomography using time-variant filtering.

    abstract::Most reconstruction algorithms used in photoacoustic tomography do not account for the effects of acoustic attenuation on the recorded signals. For experimental measurements made in biological tissue, the frequency dependent acoustic attenuation causes high frequency components of the propagating photoacoustic waves t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.036008

    authors: Treeby BE

    更新日期:2013-03-01 00:00:00

  • Reflectance confocal microscopy for characterization of mammary ductal structures and development of neoplasia in genetically engineered mouse models of breast cancer.

    abstract::The earliest steps of breast cancer begin with aberrations in mammary ductal structure. Techniques that enable an investigator to image in situ and then analyze the same tissue using biochemical tools facilitates identification of genetic networks and signaling pathways active in the imaged structure. Cellular confoca...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2065827

    authors: Parrish A,Halama E,Tilli MT,Freedman M,Furth PA

    更新日期:2005-09-01 00:00:00

  • Quantitative polarized Raman spectroscopy in highly turbid bone tissue.

    abstract::Polarized Raman spectroscopy allows measurement of molecular orientation and composition and is widely used in the study of polymer systems. Here, we extend the technique to the extraction of quantitative orientation information from bone tissue, which is optically thick and highly turbid. We discuss multiple scatteri...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3426310

    authors: Raghavan M,Sahar ND,Wilson RH,Mycek MA,Pleshko N,Kohn DH,Morris MD

    更新日期:2010-05-01 00:00:00

  • Bioluminescence measurements in mice using a skin window.

    abstract::Studies of bioluminescence in living animals, such as cell-based biosensor applications, require measurement of light at different wavelengths, but accurate light measurement is impeded by absorption by tissues at wavelengths<600 nm. We present a novel approach to this problem--the use of a plastic window in the skin/...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2795567

    authors: Huang Q,Acha V,Yow R,Schneider E,Sardar DK,Hornsby PJ

    更新日期:2007-09-01 00:00:00

  • Analysis of blood coagulation process based on fractality and dynamic characteristic of laser speckle pattern.

    abstract::The reflection and transmission of coherent light from a biological system can yield information about its condition. In the case of blood exposed to the air, there is a change in the properties of the speckle patterns observed in the coagulation process. This can be studied by means of the rate of temporal variation,...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.3.031018

    authors: Yokoi N,Aizu Y,Uozumi J

    更新日期:2018-12-01 00:00:00

  • Biochemical analysis of human breast tissues using Fourier-transform Raman spectroscopy.

    abstract::We employ Fourier-transform Raman spectroscopy to study normal and tumoral human breast tissues, including several subtypes of cancers. We analyzed 194 Raman spectra from breast tissues that were separated into 9 groups according to their corresponding histopathological diagnosis. The assignment of the relevant Raman ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2363362

    authors: Bitar RA,Martinho Hda S,Tierra-Criollo CJ,Zambelli Ramalho LN,Netto MM,Martin AA

    更新日期:2006-09-01 00:00:00

  • Fluorescence-based surface magnifying chromoendoscopy and optical coherence tomography endoscope.

    abstract::A side-viewing, 2.3-mm diameter, surface magnifying chromoendoscopy-optical coherence tomography (SMC-OCT) endoscope has been designed for simultaneous, nondestructive surface fluorescence visualization and cross-sectional imaging. We apply this endoscope to in vivo examination of the mouse colon. A 30,000 element fib...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.086003

    authors: Wall RA,Barton JK

    更新日期:2012-08-01 00:00:00

  • Spatial distribution of vastus lateralis blood flow and oxyhemoglobin saturation measured at the end of isometric quadriceps contraction by multichannel near-infrared spectroscopy.

    abstract::Muscle blood flow (MBF) and muscle oxygen saturation (SmO(2)) were measured at eight locations (four proximal, four distal) over a 4 x 8 cm(2) area of the vastus lateralis at rest and immediately after isometric, maximal quadriceps contraction using multichannel, frequency-domain, near-infrared spectroscopy. A venous ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1646417

    authors: Quaresima V,Ferrari M,Franceschini MA,Hoimes ML,Fantini S

    更新日期:2004-03-01 00:00:00

  • Neural networks improve brain cancer detection with Raman spectroscopy in the presence of operating room light artifacts.

    abstract::Invasive brain cancer cells cannot be visualized during surgery and so they are often not removed. These residual cancer cells give rise to recurrences.

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.9.094002

    authors: Jermyn M,Desroches J,Mercier J,Tremblay MA,St-Arnaud K,Guiot MC,Petrecca K,Leblond F

    更新日期:2016-09-01 00:00:00

  • Loss of image quality in photobleaching during microscopic imaging of fluorescent probes bound to chromatin.

    abstract::Prolonged excitation of fluorescent probes leads eventually to loss of their capacity to emit light. A decrease in the number of detected photons reduces subsequently the resolving power of a fluorescence microscope. Adverse effects of fluorescence intensity loss on the quality of microscopic images of biological spec...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2136313

    authors: Bernas T,Robinson JP,Asem EK,Rajwa B

    更新日期:2005-11-01 00:00:00

  • Contact, high-resolution spatial diffuse reflectance imaging system for skin condition diagnosis.

    abstract::Spatially resolved diffuse reflectance spectroscopy (srDRS) is a well-established technique for noninvasive, in vivo characterization of tissue optical properties toward diagnostic applications. srDRS has a potential for depth-resolved analysis of tissue, which is desired in various clinical situations. However, curre...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.11.115003

    authors: Petitdidier N,Koenig A,Gerbelot R,Grateau H,Gioux S,Jallon P

    更新日期:2018-11-01 00:00:00