Contact, high-resolution spatial diffuse reflectance imaging system for skin condition diagnosis.

Abstract:

:Spatially resolved diffuse reflectance spectroscopy (srDRS) is a well-established technique for noninvasive, in vivo characterization of tissue optical properties toward diagnostic applications. srDRS has a potential for depth-resolved analysis of tissue, which is desired in various clinical situations. However, current fiber-based and photodiode-based systems have difficulties achieving this goal due to challenges in sampling the reflectance with a high enough resolution. We introduce a compact, low-cost architecture for srDRS based on the use of a multipixel imaging sensor and light-emitting diodes to achieve lensless diffuse reflectance imaging in contact with the tissue with high spatial resolution. For proof-of-concept, a prototype device, involving a commercially available complementary metal-oxide semiconductor coupled with a fiber-optic plate, was fabricated. Diffuse reflectance profiles were acquired at 645 nm at source-to-detector separations ranging from 480  μm to 4 mm with a resolution of 16.7  μm. Absorption coefficients (μa) and reduced scattering coefficients (μs') of homogeneous tissue-mimicking phantoms were measured with 4.2  ±  3.5  %   and 7.0  ±  4.6  %   error, respectively. The results obtained confirm the potential of our approach for quantitative characterization of tissue optical properties in contact imaging modality. This study is a first step toward the development of low-cost, wearable devices for skin condition diagnosis in vivo.

journal_name

J Biomed Opt

authors

Petitdidier N,Koenig A,Gerbelot R,Grateau H,Gioux S,Jallon P

doi

10.1117/1.JBO.23.11.115003

subject

Has Abstract

pub_date

2018-11-01 00:00:00

pages

1-9

issue

11

eissn

1083-3668

issn

1560-2281

pii

JBO-180306R

journal_volume

23

pub_type

杂志文章
  • Sensitivity map of laser tweezers Raman spectroscopy for single-cell analysis of colorectal cancer.

    abstract::Raman spectroscopy on single, living epithelial cells captured in a laser trap is shown to have diagnostic power over colorectal cancer. This new single-cell technology comprises three major components: primary culture processing of human tissue samples to produce single-cell suspensions, Raman detection on singly tra...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2748060

    authors: Zheng F,Qin Y,Chen K

    更新日期:2007-05-01 00:00:00

  • Confocal reflectance and two-photon microscopy studies of a songbird skull for preparation of transcranial imaging.

    abstract::We present experiments and analyses of confocal reflectance and two-photon microscopy studies of zebra finch skull samples. The thin and hollow structure of these birds' skulls is quite translucent, which can allow in vivo transcranial two-photon imaging for brain activation monitoring. However, the skull structure is...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3155522

    authors: Abi-Haidar D,Olivier T

    更新日期:2009-05-01 00:00:00

  • Photoacoustic properties of anterior ocular tissues.

    abstract::Clinical imaging techniques for the anterior segment of the eye provide excellent anatomical information, but molecular imaging techniques are lacking. Molecular photoacoustic imaging is one option to address this need, but implementation requires use of contrast agents to distinguish molecular targets from background...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.5.056004

    authors: Kubelick KP,Snider EJ,Ethier CR,Emelianov S

    更新日期:2019-05-01 00:00:00

  • Near-ultraviolet removal rates for subgingival dental calculus at different irradiation angles.

    abstract::The laser ablation rate of subgingival dental calculus irradiated at a 400-nm-wavelength, 7.4-mJ pulse energy, and 85- and 20-deg irradiation angles is measured using laser triangulation. Three-dimensional images taken before and after irradiation create a removal map with 6-μm axial resolution. Fifteen human teeth wi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3564907

    authors: Schoenly JE,Seka WD,Rechmann P

    更新日期:2011-07-01 00:00:00

  • Effect of motion artifacts and their correction on near-infrared spectroscopy oscillation data: a study in healthy subjects and stroke patients.

    abstract::Functional near-infrared spectroscopy is prone to contamination by motion artifacts (MAs). Motion correction algorithms have previously been proposed and their respective performance compared for evoked rain activation studies. We study instead the effect of MAs on "oscillation" data which is at the basis of functiona...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.5.056011

    authors: Selb J,Yücel MA,Phillip D,Schytz HW,Iversen HK,Vangel M,Ashina M,Boas DA

    更新日期:2015-05-01 00:00:00

  • Dialysis-assisted fiber optic spectroscopy for in situ biomedical sensing.

    abstract::A miniature fiber optic spectrometer enclosed within a semipermeable (dialysis) membrane is proposed for in vivo interstitial sensing applications. The semipermeable membrane acts as a molecular filter, allowing only small molecules to pass through to the sampling volume. This filtering, in principle, should enable co...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2166086

    authors: Blazkiewicz P,Blazkiewicz K,Verhaege A,Anissimov YG,Roberts MS,Zvyagin AV

    更新日期:2006-01-01 00:00:00

  • Label-free separation of human embryonic stem cells and their differentiating progenies by phasor fluorescence lifetime microscopy.

    abstract::We develop a label-free optical technique to image and discriminate undifferentiated human embryonic stem cells (hESCs) from their differentiating progenies in vitro. Using intrinsic cellular fluorophores, we perform fluorescence lifetime microscopy (FLIM) and phasor analysis to obtain hESC metabolic signatures. We id...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.4.046012

    authors: Stringari C,Sierra R,Donovan PJ,Gratton E

    更新日期:2012-04-01 00:00:00

  • Comparison of spectroscopically measured tissue alcohol concentration to blood and breath alcohol measurements.

    abstract::Alcohol testing is an expanding area of interest due to the impacts of alcohol abuse that extend well beyond drunk driving. However, existing approaches such as blood and urine assays are hampered in some testing environments by biohazard risks. A noninvasive, in vivo spectroscopic technique offers a promising alterna...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3253353

    authors: Ridder TD,Ver Steeg BJ,Laaksonen BD

    更新日期:2009-09-01 00:00:00

  • Characterization of retinal biomechanical properties using Brillouin microscopy.

    abstract:SIGNIFICANCE:The retina is critical for vision, and several diseases may alter its biomechanical properties. However, assessing the biomechanical properties of the retina nondestructively is a challenge due to its fragile nature and location within the eye globe. Advancements in Brillouin spectroscopy have provided the...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.9.090502

    authors: Ambekar YS,Singh M,Scarcelli G,Rueda EM,Hall BM,Poché RA,Larin KV

    更新日期:2020-09-01 00:00:00

  • Lipid-cell interactions in human monocytes investigated by doubly-resonant coherent anti-Stokes Raman scattering microscopy.

    abstract::We demonstrate that doubly-resonant coherent anti-Stokes Raman scattering can provide enhanced and highly specific contrast for molecules containing unique Raman-active small molecular groups. This combination provides contrast for molecules that can otherwise be difficult to discriminate by Raman spectroscopy. Here, ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3544585

    authors: Weeks T,Schie I,den Hartigh LJ,Rutledge JC,Huser T

    更新日期:2011-02-01 00:00:00

  • Detection of breast surgical margins with optical coherence tomography imaging: a concept evaluation study.

    abstract::This study aimed to evaluate the concept of using high-resolution optical coherence tomography (OCT) imaging to rapidly assess surgical specimens and determine if cancer positive margins were left behind in the surgical bed. A mouse model of breast cancer was used in this study. Surgical specimens from 30 animals were...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.5.056001

    authors: Savastru D,Chang EW,Miclos S,Pitman MB,Patel A,Iftimia N

    更新日期:2014-05-01 00:00:00

  • Quantitative microscopy and nanoscopy of sickle red blood cells performed by wide field digital interferometry.

    abstract::We have applied wide-field digital interferometry (WFDI) to examine the morphology and dynamics of live red blood cells (RBCs) from individuals who suffer from sickle cell anemia (SCA), a genetic disorder that affects the structure and mechanical properties of RBCs. WFDI is a noncontact, label-free optical microscopy ...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3556717

    authors: Shaked NT,Satterwhite LL,Telen MJ,Truskey GA,Wax A

    更新日期:2011-03-01 00:00:00

  • Diagnostic performance of receptor-specific surgical specimen staining correlates with receptor expression level.

    abstract::Intraoperative margin assessment is imperative to cancer cure but is a continued challenge to successful surgery. Breast conserving surgery is a relevant example, where a cosmetically improved outcome is gained over mastectomy, but re-excision is required in >25  %   of cases due to positive or closely involved margin...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.2.026002

    authors: Schaefer JM,Barth CW,Davis SC,Gibbs SL

    更新日期:2019-02-01 00:00:00

  • Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry.

    abstract::Optical spectroscopy, imaging, and therapy tissue phantoms must have the scattering and absorption properties that are characteristic of human tissues, and over the past few decades, many useful models have been created. In this work, an overview of their composition and properties is outlined, by separating matrix, s...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.2335429

    authors: Pogue BW,Patterson MS

    更新日期:2006-07-01 00:00:00

  • Photon migration through fetal head in utero using continuous wave, near-infrared spectroscopy: development and evaluation of experimental and numerical models.

    abstract::In this work experimental tissue phantoms and numerical models were developed to estimate photon migration through the fetal head in utero. The tissue phantoms incorporate a fetal head within an amniotic fluid sac surrounded by a maternal tissue layer. A continuous wave, dual-wavelength (lambda = 760 and 850 nm) spect...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429983

    authors: Vishnoi G,Hielscher AH,Ramanujam N,Chance B

    更新日期:2000-04-01 00:00:00

  • Single-cell analysis of dihydroartemisinin-induced apoptosis through reactive oxygen species-mediated caspase-8 activation and mitochondrial pathway in ASTC-a-1 cells using fluorescence imaging techniques.

    abstract::Dihydroartemisinin (DHA), a front-line antimalarial herbal compound, has been shown to possess promising anticancer activity with low toxicity. We have previously reported that DHA induced caspase-3-dependent apoptosis in human lung adenocarcinoma cells. However, the cellular target and molecular mechanism of DHA-indu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3481141

    authors: Lu YY,Chen TS,Wang XP,Li L

    更新日期:2010-07-01 00:00:00

  • Understanding three-dimensional spatial relationship between the mouse second polar body and first cleavage plane with full-field optical coherence tomography.

    abstract::The morphogenetic relationship between early patterning and polarity formation is of fundamental interest and remains a controversial issue in preimplantation embryonic development. We use a label-free three-dimensional (3-D) imaging technique of full-field optical coherence tomography (FF-OCT) successfully for the fi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.1.010503

    authors: Zheng JG,Huo T,Chen T,Wang C,Zhang N,Tian N,Zhao F,Lu D,Chen D,Ma W,Sun JL,Xue P

    更新日期:2013-01-01 00:00:00

  • Ammonia and ethylene biomarkers in the respiration of the people with schizophrenia using photoacoustic spectroscopy.

    abstract::Oxidative stress has become an exciting area of schizophrenia (SCZ) research, and provides ample opportunities and hope for a better understanding of its pathophysiology, which may lead to new treatment strategies. The first objective of the present study was to analyze the oxidative stress markers in breath samples o...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.5.057006

    authors: Popa C,Petrus M,Bratu AM

    更新日期:2015-05-01 00:00:00

  • Quantitative fluorescence imaging of protoporphyrin IX through determination of tissue optical properties in the spatial frequency domain.

    abstract::The ability to quantitatively determine tissue fluorescence is of interest for the purpose of better understanding the details of photodynamic therapy of skin cancer. In particular, we are interested in quantifying protoporphyrin IX (PpIX) in vivo. We present a method of correcting fluorescence for effects of native t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3665440

    authors: Saager RB,Cuccia DJ,Saggese S,Kelly KM,Durkin AJ

    更新日期:2011-12-01 00:00:00

  • Parameters affecting ultrafast laser microsurgery of subepithelial voids for scar treatment in vocal folds.

    abstract::Toward developing a new method for restoring tissue viscoelasticity in scarred vocal folds, we previously proposed a method to localize biomaterials within subepithelial voids ablated using ultrafast laser pulses. The clinical implementation of this method necessitates the quantification of the laser parameters for ab...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.11.118001

    authors: Yildirim M,Ferhanoglu O,Kobler J,Zeitels SM,Ben-Yakar A

    更新日期:2013-11-01 00:00:00

  • Bipolar cellular morphology of malignant melanoma in unstained human melanoma skin tissue.

    abstract::Microstructures of unstained human melanoma skin tissues have been examined by multimodal nonlinear optical microscopy. The polarized shape of the individual melanoma cell can be readily recognized-a phenotype that has been identified in laboratory cultures as characteristic of proliferating melanocytes but has not be...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3120491

    authors: Zhang K,Zhang W,Yang CY,Yang H

    更新日期:2009-03-01 00:00:00

  • Ultrafast wavelength multiplexed broad bandwidth digital diffuse optical spectroscopy for in vivo extraction of tissue optical properties.

    abstract::Frequency-domain diffuse optical spectroscopy (FD-DOS) utilizes intensity-modulated light to characterize optical scattering and absorption in thick tissue. Previous FD-DOS systems have been limited by large device footprints, complex electronics, high costs, and limited acquisition speeds, all of which complicate acc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.3.036009

    authors: Torjesen A,Istfan R,Roblyer D

    更新日期:2017-03-01 00:00:00

  • Two-photon microscopy of cortical NADH fluorescence intensity changes: correcting contamination from the hemodynamic response.

    abstract::Quantification of nicotinamide adenine dinucleotide (NADH) changes during functional brain activation and pathological conditions provides critical insight into brain metabolism. Of the different imaging modalities, two-photon laser scanning microscopy (TPLSM) is becoming an important tool for cellular-resolution meas...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3633339

    authors: Baraghis E,Devor A,Fang Q,Srinivasan VJ,Wu W,Lesage F,Ayata C,Kasischke KA,Boas DA,Sakadzić S

    更新日期:2011-10-01 00:00:00

  • Intravascular near-infrared fluorescence catheter with ultrasound guidance and blood attenuation correction.

    abstract::Intravascular near-infrared fluorescence (NIRF) imaging offers a new approach for characterizing atherosclerotic plaque, but random catheter positioning within the vessel lumen results in variable light attenuation and can yield inaccurate measurements. We hypothesized that NIRF measurements could be corrected for var...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.5.056009

    authors: Dixon AJ,Hossack JA

    更新日期:2013-05-01 00:00:00

  • Low-level chemiluminescent analysis of nondiluted human blood reveals its dynamic system properties.

    abstract::Lucigenin- and luminol-dependent chemiluminescence [(LC-CL) and (LM-CL)] in nondiluted human blood was studied. LM-CL was low in fresh blood and disappeared after its storage for 3 h, though the respiratory burst (RB) stimulation in blood was followed by high intensity and long-lasting LM-CL. LC-CL was high in fresh b...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429921

    authors: Voeikov VL,Novikov CN,Vilenskaya ND

    更新日期:1999-01-01 00:00:00

  • Stress analysis in oral obturator prostheses, part II: photoelastic imaging.

    abstract::In part I of the study, two attachment systems [O-ring; bar-clip (BC)] were used, and the system with three individualized O-rings provided the lowest stress on the implants and the support tissues. Therefore, the aim of this study was to assess the stress distribution, through the photoelastic method, on implant-reta...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.6.066012

    authors: Pesqueira AA,Goiato MC,da Silva EV,Haddad MF,Moreno A,Zahoui A,dos Santos DM

    更新日期:2014-06-01 00:00:00

  • Angiography with a multifunctional line scanning ophthalmoscope.

    abstract::A multifunctional line scanning ophthalmoscope (mLSO) was designed, constructed, and tested on human subjects. The mLSO could sequentially acquire wide-field, confocal, near-infrared reflectance, fluorescein angiography (FA), and indocyanine green angiography (ICGA) retinal images. The system also included a retinal t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.2.026008

    authors: Hammer DX,Ferguson RD,Patel AH,Vazquez V,Husain D

    更新日期:2012-02-01 00:00:00

  • Autofluorescence of epithelial tissue: single-photon versus two-photon excitation.

    abstract::We instrumented a combined fluorescence spectroscopy and imaging system to characterize the single- and two-photon excited autofluorescence in epithelial tissue. Single-photon fluorescence (SPF) are compared with two-photon fluorescence (TPF) measured at the same location in epithelial tissue. It was found that the SP...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2975866

    authors: Zheng W,Wu Y,Li D,Qu JY

    更新日期:2008-09-01 00:00:00

  • Laser trap ionization for identification of human erythrocytes with variable hemoglobin quantitation.

    abstract::An approach to an established technique that is potentially applicable for a more comprehensive understanding of the electrical properties of red blood cells (RBCs) is presented. Using a high-intensity gradient laser trap, RBCs can be singly trapped and consequentially ionized. The subsequent dynamics of the ionized c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.5.055005

    authors: Kelley M,Cooper J,Devito D,Mushi R,Aguinaga MDP,Erenso DB

    更新日期:2018-05-01 00:00:00

  • All fiber optics circular-state swept source polarization-sensitive optical coherence tomography.

    abstract::A swept source (SS)-based circular-state (CS) polarization-sensitive optical coherence tomography (PS-OCT) constructed entirely with polarization-maintaining fiber optics components is proposed with the experimental verification. By means of the proposed calibration scheme, bulk quarter-wave plates can be replaced by ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.2.021110

    authors: Lin H,Kao MC,Lai CM,Huang JC,Kuo WC

    更新日期:2014-02-01 00:00:00