Abstract:
:Dihydroartemisinin (DHA), a front-line antimalarial herbal compound, has been shown to possess promising anticancer activity with low toxicity. We have previously reported that DHA induced caspase-3-dependent apoptosis in human lung adenocarcinoma cells. However, the cellular target and molecular mechanism of DHA-induced apoptosis is still poorly defined. We use confocal fluorescence microscopy imaging, fluorescence resonance energy transfer, and fluorescence recovery after photobleaching techniques to explore the roles of DHA-elicited reactive oxygen species (ROS) in the DHA-induced Bcl-2 family proteins activation, mitochondrial dysfunction, caspase cascade, and cell death. Cell Counting Kit-8 assay and flow cytometry analysis showed that DHA induced ROS-mediated apoptosis. Confocal imaging analysis in a single living cell and Western blot assay showed that DHA triggered ROS-dependent Bax translocation, mitochondrial membrane depolarization, alteration of mitochondrial morphology, cytochrome c release, caspase-9, caspase-8, and caspase-3 activation, indicating the coexistence of ROS-mediated mitochondrial and death receptor pathway. Collectively, our findings demonstrate for the first time that DHA induces cell apoptosis by triggering ROS-mediated caspase-8/Bid activation and the mitochondrial pathway, which provides some novel insights into the application of DHA as a potential anticancer drug and a new therapeutic strategy by targeting ROS signaling in lung adenocarcinoma therapy in the future.
journal_name
J Biomed Optjournal_title
Journal of biomedical opticsauthors
Lu YY,Chen TS,Wang XP,Li Ldoi
10.1117/1.3481141subject
Has Abstractpub_date
2010-07-01 00:00:00pages
046028issue
4eissn
1083-3668issn
1560-2281journal_volume
15pub_type
杂志文章abstract::A highly efficient method based on Maxwell's theory was developed, which enables the calculation of the scanning of a focused beam through scattering media. Maxwell's equations were numerically solved in two dimensions using finite difference time domain simulations. The modeling of the focused beam was achieved by ap...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.19.7.071404
更新日期:2014-07-01 00:00:00
abstract::Frequency domain optical coherence tomography (FD-OCT), based on an all-reflective high-speed InGaAs spectrometer, operating in the 1050 nm wavelength region for retinal diagnostics, enables high-speed, volumetric imaging of retinal pathologies with greater penetration into choroidal tissue is compared to conventional...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2773728
更新日期:2007-07-01 00:00:00
abstract::Fluorescence spectroscopy is a promising technology for detection of epithelial precancers and cancers. While age and menopausal status influence measurements in the cervix, other variables do not significantly affect the diagnosis. In this study we examine probe pressure as a variable. A fiber optic probe to measure ...
journal_title:Journal of biomedical optics
pub_type: 临床试验,杂志文章
doi:10.1117/1.1695562
更新日期:2004-05-01 00:00:00
abstract:SIGNIFICANCE:Detailed biochemical and morphological imaging of the plaque burdened coronary arteries holds the promise of improved understanding of atherosclerosis plaque development, ultimately leading to better diagnostics and therapies. AIM:Development of a dual-modality intravascular catheter supporting swept-sour...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.25.9.096010
更新日期:2020-09-01 00:00:00
abstract::A microelectromechanical system (MEMS) mirror based endoscopic swept-source optical coherence tomography (SS-OCT) system that can perform three-dimensional (3-D) imaging at high speed is reported. The key component enabling 3-D endoscopic imaging is a two-axis MEMS scanning mirror which has a 0.8×0.8 mm2 mirror plate...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.8.086005
更新日期:2013-08-01 00:00:00
abstract::We demonstrate the ex vivo imaging of an oral cancerous sample with a swept-source optical coherence tomography (SS-OCT) system. With the axial resolution of 8 microm in free space and system sensitivity of 108 dB, we can well distinguish the normal and abnormal tissue portions in a sample. In particular, we analyze t...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2960632
更新日期:2008-07-01 00:00:00
abstract::Optical coherence tomography (OCT) is an emergent imaging tool used for noninvasive diagnosis of skin diseases. The present meta-analysis was carried out to assess the accuracy of OCT for the diagnosis of skin cancer. We conducted a systematic literature search though EMBASE, Medline, PubMed, the Cochrane Library, and...
journal_title:Journal of biomedical optics
pub_type: 杂志文章,meta分析
doi:10.1117/1.JBO.23.2.020902
更新日期:2018-02-01 00:00:00
abstract::Spectral resolved tissue imaging has a broad range of biomedical applications such as the minimally invasive diagnosis of diseases and the study of wound healing and tissue engineering processes. Two-photon microscopy imaging of endogenous fluorescence has been shown to be a powerful method for the quantification of t...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1891370
更新日期:2005-03-01 00:00:00
abstract:SIGNIFICANCE:Visible light optical coherence tomography (OCT) is emerging for spectroscopic and ultrahigh resolution imaging, but challenges remain. Depth-dependent dispersion limits retinal image quality and current correction approaches are cumbersome. Inconsistent group refractive indices during image reconstruction...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.25.9.090501
更新日期:2020-09-01 00:00:00
abstract::High resolution is important for sensitive detection of subtle distortions of retinal morphology at an early stage of eye diseases. We demonstrate virtually structured detection (VSD) as a feasible method to achieve in vivo super-resolution ophthalmoscopy. A line-scanning strategy was employed to achieve a super-resol...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.12.120502
更新日期:2016-12-01 00:00:00
abstract::This study investigates the correlation of tumor blood oxygenation and tumor pO(2) with respect to carbogen inhalation. After having refined and validated the algorithms for calculating hemoglobin concentrations, we used near-infrared spectroscopy (NIRS) to measure changes of oxygenated hemoglobin concentration (delta...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1527049
更新日期:2003-01-01 00:00:00
abstract::Angle-resolved signals of polarized light scattered by biological cells provide rich information on cell morphology. Quantitative study of these signals can lead to new methods to develop and improve high-throughput instrumentation for cell probing such as scattering-based flow cytometry. We employ a goniometer system...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2749730
更新日期:2007-05-01 00:00:00
abstract::A swept source (SS)-based circular-state (CS) polarization-sensitive optical coherence tomography (PS-OCT) constructed entirely with polarization-maintaining fiber optics components is proposed with the experimental verification. By means of the proposed calibration scheme, bulk quarter-wave plates can be replaced by ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.19.2.021110
更新日期:2014-02-01 00:00:00
abstract::Microstructures of unstained human melanoma skin tissues have been examined by multimodal nonlinear optical microscopy. The polarized shape of the individual melanoma cell can be readily recognized-a phenotype that has been identified in laboratory cultures as characteristic of proliferating melanocytes but has not be...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3120491
更新日期:2009-03-01 00:00:00
abstract::We report a photonic approach for selective inactivation of viruses with a near-infrared subpicosecond laser. We demonstrate that this method can selectively inactivate viral particles ranging from nonpathogenic viruses such as the M13 bacteriophage and the tobacco mosaic virus to pathogenic viruses such as the human ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3275477
更新日期:2009-11-01 00:00:00
abstract::An autofluorescence lifetime wide-field imaging system that can generate contrast in underlying tissue structures of normal and malignant brain tissue samples with video rate acquisition and processing time is presented. Images of the investigated tissues were acquired with high resolution (∼35 μm) using an algorithm ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.6.060504
更新日期:2013-06-01 00:00:00
abstract::Optically derived tissue properties across a range of breast densities and the effects of breast compression on estimates of hemoglobin, oxygen metabolism, and water and lipid concentrations were obtained from a coregistered imaging system that integrates near-infrared spectral tomography (NIRST) with digital breast t...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.9.091316
更新日期:2016-09-01 00:00:00
abstract::We measure the tumor vascular response to varying irradiance rates during photodynamic therapy (PDT) in a Dunning rat prostate model with interstitial Doppler optical coherence tomography (IS-DOCT). Rats are given a photosensitizer drug, Photofrin, and the tumors are exposed to light (635 nm) with irradiance rates ran...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2744068
更新日期:2007-05-01 00:00:00
abstract::Mueller polarimetry is applied to study the samples of nails: natural (or reference) and irradiated to 2 Gy ionizing radiation dose. We measure the whole Mueller matrices of the samples as a function of the scattering angle at a wavelength of 632.8 nm. We apply depolarization analysis to measured Mueller matrices by c...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.7.071108
更新日期:2016-07-01 00:00:00
abstract::Hyperspectral reflectance imaging technique has been used for in vivo detection of cervical intraepithelial neoplasia. However, the clinical outcome of this technique is suboptimal owing to multiple limitations such as nonuniform illumination, high-cost and bulky setup, and time-consuming data acquisition and processi...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.12.121303
更新日期:2015-12-01 00:00:00
abstract::The epithelium (EP) thickness and the standard deviation (SD) of A-mode scan intensity in the laminar propria (LP) layer are used as effective indicators for the diagnosis of oral submucous fibrosis (OSF) based on the noninvasive clinical scanning of a swept-source optical coherence tomography (OCT) system of approxim...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3233653
更新日期:2009-09-01 00:00:00
abstract::All aberrations produced inside a biospecimen can degrade the quality of a three-dimensional image in two-photon excitation laser scanning microscopy. Previously, we developed a transmissive liquid-crystal device to correct spherical aberrations that improved the image quality of a fixed-mouse-brain slice treated with...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.12.121503
更新日期:2016-12-01 00:00:00
abstract::Artificially created demineralized and remineralized carious lesions on the root and enamel of human teeth were examined by photothermal radiometry (PTR) and modulated luminescence (LUM). Fourteen extracted human teeth were used and a lesion was created on a 1 mmx4 mm rectangular window, spanning root to enamel, using...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2942374
更新日期:2008-05-01 00:00:00
abstract::Intraoperative fluorescence molecular imaging based on targeted fluorescence agents is an emerging approach to improve surgical and endoscopic imaging and guidance. Short exposure times per frame and implementation at video rates are necessary to provide continuous feedback to the physician and avoid motion artifacts....
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.19.4.046012
更新日期:2014-04-01 00:00:00
abstract::Different colors of visible light penetrate to varying depths in tissue due to the wavelength dependence of tissue optical absorption and elastic scattering. We exploit this to map the contour of the closest surface of a buried fluorescent object. This uses a novel algorithm based on the diffusion theory description o...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3523369
更新日期:2010-11-01 00:00:00
abstract::During emergency medical situations, where the patient has an obstructed airway or necessitates respiratory support, endotracheal intubation (ETI) is the medical technique of placing a tube into the trachea in order to facilitate adequate ventilation of the lungs. Complications during ETI, such as repeated attempts, f...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.11.117004
更新日期:2016-11-01 00:00:00
abstract::Parametric and nonparametric data processing schemes for analyzing translating laser speckle data used to investigate the mechanical behavior of biological tissues are examined. Cross-correlation, minimum mean square estimator, maximum likelihood, and maximum entropy approaches are discussed and compared on speckle da...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1412224
更新日期:2001-10-01 00:00:00
abstract::A confocal imaging and image processing scheme is introduced to visualize and evaluate the spatial distribution of spectral information in tissue. The image data are recorded using a confocal laser-scanning microscope equipped with a detection unit that provides high spectral resolution. The processing scheme is based...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.17.10.106011
更新日期:2012-10-01 00:00:00
abstract::Environmental metastability of zirconia (ZrO2) ceramic in the human body [represented by a tetragonal-to-monoclinic (t→m) phase transformation] takes place on the surface of the artificial joint and proceeds with time toward its interior. Its quantitative characterization is mandatory for the safety of joint implants ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.12.127002
更新日期:2013-12-01 00:00:00
abstract::We fabricate scaffolds with a fine linear grating (periodicity of 1 to 8 microm and height of 1 microm) on a glass substrate for controlling cardiomyocyte orientation. The fabrication is done by the solidification of a liquid photopolymerizable material using two laser beam interference. As the photopolymerizable mate...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2186042
更新日期:2006-03-01 00:00:00