Transmissive liquid-crystal device for correcting primary coma aberration and astigmatism in biospecimen in two-photon excitation laser scanning microscopy.

Abstract:

:All aberrations produced inside a biospecimen can degrade the quality of a three-dimensional image in two-photon excitation laser scanning microscopy. Previously, we developed a transmissive liquid-crystal device to correct spherical aberrations that improved the image quality of a fixed-mouse-brain slice treated with an optical clearing reagent. In this study, we developed a transmissive device that corrects primary coma aberration and astigmatism. The motivation for this study is that asymmetric aberration can be induced by the shape of a biospecimen and/or by a complicated refractive-index distribution in a sample; this can considerably degrade optical performance even near the sample surface. The device’s performance was evaluated by observing fluorescence beads. The device was inserted between the objective lens and microscope revolver and succeeded in improving the spatial resolution and fluorescence signal of a bead image that was originally degraded by asymmetric aberration. Finally, we implemented the device for observing a fixed whole mouse brain with a sloping surface shape and complicated internal refractive-index distribution. The correction with the device improved the spatial resolution and increased the fluorescence signal by ?2.4×. The device can provide a simple approach to acquiring higher-quality images of biospecimens.

journal_name

J Biomed Opt

authors

Tanabe A,Hibi T,Ipponjima S,Matsumoto K,Yokoyama M,Kurihara M,Hashimoto N,Nemoto T

doi

10.1117/1.JBO.21.12.121503

subject

Has Abstract

pub_date

2016-12-01 00:00:00

pages

121503

issue

12

eissn

1083-3668

issn

1560-2281

pii

2553354

journal_volume

21

pub_type

杂志文章
  • Anomalous photobleaching in fluorescence recovery after photobleaching measurements due to excitation saturation--a case study for fluorescein.

    abstract::In this study we examine the implications of excitation saturation on fluorescence recovery after photobleaching (FRAP) experiments. In particular we present both experimental and theoretical evidence that fluorescein, one of the most frequently used fluorophores in FRAP, does not always comply with the basic assumpti...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2337531

    authors: Braeckmans K,Stubbe BG,Remaut K,Demeester J,De Smedt SC

    更新日期:2006-07-01 00:00:00

  • Specific absorption spectra of hemoglobin at different PO2 levels: potential noninvasive method to detect PO2 in tissues.

    abstract::Hemoglobin (Hb), as one of main components of blood, has a unique quaternary structure. Its release of oxygen is controlled by oxygen partial pressure (PO2). We investigate the specific spectroscopic changes in Hb under different PO2 levels to optimize clinical methods of measuring tissue PO2. The transmissivity of Hb...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.12.125002

    authors: Liu P,Zhu Z,Zeng C,Nie G

    更新日期:2012-12-01 00:00:00

  • Imaging and tracking HIV viruses in human cervical mucus.

    abstract::We describe a systematic approach to image, track, and quantify the movements of HIV viruses embedded in human cervical mucus. The underlying motivation for this study is that, in HIV-infected adults, women account for more than half of all new cases and most of these women acquire the infection through heterosexual c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.9.096001

    authors: Boukari F,Makrogiannis S,Nossal R,Boukari H

    更新日期:2016-09-01 00:00:00

  • Optical pH measurement system using a single fluorescent dye for assessing susceptibility to dental caries.

    abstract::Sugar-rich diets and poor dental hygiene promote the formation of a biofilm (plaque) that strongly adheres to the dental enamel surface and fosters the evolution of aciduric bacteria. The acid contributes to demineralization of the exterior tooth enamel, which accelerates after the pH drops below a critical value (∼5....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.1.017001

    authors: Sharma M,Graham JY,Walczak PA,Nguyen R,Lee LK,Carson MD,Nelson LY,Patel SN,Xu Z,Seibel EJ

    更新日期:2019-01-01 00:00:00

  • Transmission versus reflectance spectroscopy for quantitation.

    abstract::The objective of this work was to compare the accuracy of analyte concentration estimation when using transmission versus diffuse reflectance spectroscopy of a scattering medium. Monte Carlo ray tracing of light through the medium was used in conjunction with pure component absorption spectra and Beer-Lambert absorpti...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.1.018001

    authors: Gardner CM

    更新日期:2018-01-01 00:00:00

  • SpineLab: tool for three-dimensional reconstruction of neuronal cell morphology.

    abstract::SpineLab is a software tool developed for reconstructing neuronal feature skeletons from three-dimensional single- or multi-photon image stacks. These images often suffer from limited resolution and a low signal-to-noise ratio, making the extraction of morphometric information difficult. To overcome this limitation, w...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.076007

    authors: Jungblut D,Vlachos A,Schuldt G,Zahn N,Deller T,Wittum G

    更新日期:2012-07-01 00:00:00

  • Quantitative phase microscopy of articular chondrocyte dynamics by wide-field digital interferometry.

    abstract::We experimentally implement label-free phase microscopy using wide-field digital interferometry (WFDI) techniques to retrieve quantitative volumetric data of articular chondrocyte dynamics. Using the scanless interferometric system, we visualize chondrocyte swelling and bursting induced by hypo-osmotic pressure. Recon...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3290242

    authors: Shaked NT,Finan JD,Guilak F,Wax A

    更新日期:2010-01-01 00:00:00

  • Enhanced thulium fiber laser lithotripsy using micro-pulse train modulation.

    abstract::The thulium fiber laser (TFL) is currently being studied as an alternative to the conventional holmium:YAG (Ho:YAG) laser for lithotripsy. The diode-pumped TFL may be electronically modulated to operate with variable parameters (e.g., pulse rate, pulse duration, and duty cycle) for studying the influence of pulse trai...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.2.028002

    authors: Blackmon RL,Irby PB,Fried NM

    更新日期:2012-02-01 00:00:00

  • Dynamic in vivo imaging of small animal brain using pulsed laser diode-based photoacoustic tomography system.

    abstract::We demonstrate dynamic in vivo imaging using a low-cost portable pulsed laser diode (PLD)-based photoacoustic tomography system. The system takes advantage of an 803-nm PLD having high-repetition rate ∼7000  Hz combined with a fast-scanning single-element ultrasound transducer leading to a 5 s cross-sectional imaging....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.9.090501

    authors: Upputuri PK,Pramanik M

    更新日期:2017-09-01 00:00:00

  • Study of molecule variations in renal tumor based on confocal micro-Raman spectroscopy.

    abstract::Confocal micro-Raman spectroscopy--a valuable analytical tool in biological and medical field of research-allows probing molecular vibrations of samples without external labels or extensive preparation. We employ confocal micro-Raman spectroscopy to characterize renal tumors and normal tissue. Results show that Raman ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.031103

    authors: Zhuang Z,Li N,Guo Z,Zhu M,Xiong K,Chen S

    更新日期:2013-03-01 00:00:00

  • Continuous monitoring of arthritis in animal models using optical imaging modalities.

    abstract::Given the several difficulties associated with histology, including difficulty in continuous monitoring, this study aimed to investigate the feasibility of optical imaging modalities—cross-polarization color (CPC) imaging, erythema index (EI) imaging, and laser speckle contrast (LSC) imaging—for continuous evaluation ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.106010

    authors: Son T,Yoon HJ,Lee S,Jang WS,Jung B,Kim WU

    更新日期:2014-01-01 00:00:00

  • Listening to membrane potential: photoacoustic voltage-sensitive dye recording.

    abstract::Voltage-sensitive dyes (VSDs) are designed to monitor membrane potential by detecting fluorescence changes in response to neuronal or muscle electrical activity. However, fluorescence imaging is limited by depth of penetration and high scattering losses, which leads to low sensitivity in vivo systems for external dete...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.4.045006

    authors: Zhang HK,Yan P,Kang J,Abou DS,Le HN,Jha AK,Thorek DL,Kang JU,Rahmim A,Wong DF,Boctor EM,Loew LM

    更新日期:2017-04-01 00:00:00

  • Measurement and imaging of birefringent properties of the human cornea with phase-resolved, polarization-sensitive optical coherence tomography.

    abstract::Optical coherence tomography (OCT) is an emerging technology for high-resolution, noncontact imaging of transparent and scattering media. Polarization-sensitive optical coherence tomography (PS-OCT) is a functional extension of OCT that can image birefringent properties of a biological sample. PS-OCT was used to measu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1629308

    authors: Götzinger E,Pircher M,Sticker M,Fercher AF,Hitzenberger CK

    更新日期:2004-01-01 00:00:00

  • Combined anatomical optical coherence tomography and intraluminal pressure reveal viscoelasticity of the in vivo airway.

    abstract::It is hypothesized that the local, viscoelastic (time-dependent) properties of the airway are important to accurately model and ultimately predict dynamic airway collapse in airway obstruction. Toward this end, we present a portable, endoscopic, swept-source anatomical optical coherence tomography (aOCT) system combin...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.23.10.100501

    authors: Balakrishnan S,Bu R,Iftimia N,Price H,Zdanski C,Oldenburg AL

    更新日期:2018-10-01 00:00:00

  • Modeling of the temporal effects of heating during infrared neural stimulation.

    abstract::A model of infrared neural stimulation (INS) has been developed to allow the temporal characteristics of different stimulation parameters and geometries to be better understood. The model uses a finite element approach to solve the heat equation and allow detailed analysis of heat during INS with both microsecond and ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.035004

    authors: Thompson AC,Wade SA,Cadusch PJ,Brown WG,Stoddart PR

    更新日期:2013-03-01 00:00:00

  • Light propagation in a turbid medium with insonified microbubbles.

    abstract::Surfactant stabilized microbubbles are widely used clinical contrast agents for ultrasound imaging. In this work, the light propagation through a turbid medium in the presence of microbubbles has been investigated. Through a series of experiments, it has been found that the optical attenuation is increased when the mi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.1.015002

    authors: Leung TS,Honeysett JE,Stride E,Deng J

    更新日期:2013-01-01 00:00:00

  • Ethidium bromide as a marker of mtDNA replication in living cells.

    abstract::Mitochondrial DNA (mtDNA) in tumor cells was found to play an important role in maintaining the malignant phenotype. Using laser scanning confocal fluorescence microscopy (LSCFM) in a recent work, we reported a variable fluorescence intensity of ethidium bromide (EB) in mitochondria nucleoids of living carcinoma cells...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.4.046001

    authors: Villa AM,Fusi P,Pastori V,Amicarelli G,Pozzi C,Adlerstein D,Doglia SM

    更新日期:2012-04-01 00:00:00

  • In vivo near-infrared dual-axis confocal microendoscopy in the human lower gastrointestinal tract.

    abstract::Near-infrared confocal microendoscopy is a promising technique for deep in vivo imaging of tissues and can generate high-resolution cross-sectional images at the micron-scale. We demonstrate the use of a dual-axis confocal (DAC) near-infrared fluorescence microendoscope with a 5.5-mm outer diameter for obtaining clini...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.2.021102

    authors: Piyawattanametha W,Ra H,Qiu Z,Friedland S,Liu JT,Loewke K,Kino GS,Solgaard O,Wang TD,Mandella MJ,Contag CH

    更新日期:2012-02-01 00:00:00

  • Cell disintegration by laser-induced transient microbubbles and its simultaneous monitoring by interferometry.

    abstract::Selective retina treatment (SRT) is a novel short pulsed laser therapy of several retinal diseases associated with a decreased metabolism at the retinal pigment epithelium (RPE). The range of laser pulse energies is small, in which the desired selective RPE disintegration is achieved without adverse effects to the neu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2339815

    authors: Neumann J,Brinkmann R

    更新日期:2006-07-01 00:00:00

  • Effect of motion artifacts and their correction on near-infrared spectroscopy oscillation data: a study in healthy subjects and stroke patients.

    abstract::Functional near-infrared spectroscopy is prone to contamination by motion artifacts (MAs). Motion correction algorithms have previously been proposed and their respective performance compared for evoked rain activation studies. We study instead the effect of MAs on "oscillation" data which is at the basis of functiona...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.5.056011

    authors: Selb J,Yücel MA,Phillip D,Schytz HW,Iversen HK,Vangel M,Ashina M,Boas DA

    更新日期:2015-05-01 00:00:00

  • Multiphoton fluorescence lifetime imaging of chemotherapy distribution in solid tumors.

    abstract::Doxorubicin is a commonly used chemotherapeutic employed to treat multiple human cancers, including numerous sarcomas and carcinomas. Furthermore, doxorubicin possesses strong fluorescent properties that make it an ideal reagent for modeling drug delivery by examining its distribution in cells and tissues. However, wh...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.11.116010

    authors: Carlson M,Watson AL,Anderson L,Largaespada DA,Provenzano PP

    更新日期:2017-11-01 00:00:00

  • Micro-Raman spectroscopy study of cancerous and normal nasopharyngeal tissues.

    abstract::The capabilities of micro-Raman spectroscopy for differentiating normal and malignant nasopharyngeal tissues were evaluated. Raman scattering signals were acquired from 22 normal and 52 malignant nasopharyngeal tissue samples. Distinctive spectral differences in Raman spectra between normal and malignant nasopharyngea...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.2.027003

    authors: Li Y,Pan J,Chen G,Li C,Lin S,Shao Y,Feng S,Huang Z,Xie S,Zeng H,Chen R

    更新日期:2013-02-01 00:00:00

  • Optical imaging for brain tissue characterization using relative fluorescence lifetime imaging.

    abstract::An autofluorescence lifetime wide-field imaging system that can generate contrast in underlying tissue structures of normal and malignant brain tissue samples with video rate acquisition and processing time is presented. Images of the investigated tissues were acquired with high resolution (∼35 μm) using an algorithm ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.6.060504

    authors: Papour A,Taylor Z,Sherman A,Sanchez D,Lucey G,Liau L,Stafsudd O,Yong W,Grundfest W

    更新日期:2013-06-01 00:00:00

  • Effect of probe pressure on cervical fluorescence spectroscopy measurements.

    abstract::Fluorescence spectroscopy is a promising technology for detection of epithelial precancers and cancers. While age and menopausal status influence measurements in the cervix, other variables do not significantly affect the diagnosis. In this study we examine probe pressure as a variable. A fiber optic probe to measure ...

    journal_title:Journal of biomedical optics

    pub_type: 临床试验,杂志文章

    doi:10.1117/1.1695562

    authors: Nath A,Rivoire K,Chang S,Cox D,Atkinson EN,Follen M,Richards-Kortum R

    更新日期:2004-05-01 00:00:00

  • Potential of optical microangiography to monitor cerebral blood perfusion and vascular plasticity following traumatic brain injury in mice in vivo.

    abstract::Optical microanglography (OMAG) is a recently developed imaging modality capable of volumetric imaging of dynamic blood perfusion, down to capillary level resolution, with an imaging depth up to 2.00 mm beneath the tissue surface. We report the use of OMAG to monitor the cerebral blood flow (CBF) over the cortex of mo...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3207121

    authors: Jia Y,Alkayed N,Wang RK

    更新日期:2009-07-01 00:00:00

  • Laser scoop desobliteration: a method for minimally invasive remote recanalization of chronically occluded superficial femoral arteries.

    abstract::Stenosis and occlusion of the superficial femoral artery (SFA) are most common in arterial occlusive disease. There are numerous interventional, surgical, and combined approaches to reconstitute maximum blood supply to the lower limb; however, despite intense clinical research, the long-term success rates are still po...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.2.025005

    authors: Heneweer C,Siggelkow M,Helle M,Petzina R,Wulff A,Schaefer JP,Berndt R,Rusch R,Wedel T,Klaws G,Müller-Gerbl M,Röcken C,Jansen O,Lutter G,Cremer J,Groß J

    更新日期:2015-02-01 00:00:00

  • Human graft cornea and laser incisions imaging with micrometer scale resolution full-field optical coherence tomography.

    abstract::Micrometer scale resolution full-field optical coherence tomography (FF-OCT) is developed for imaging human graft corneas. Three-dimensional (3-D) images with ultrahigh resolution (respectively, 1 and 1.5 μm in the axial and transverse directions), comparable to traditional histological sections, are obtained allowing...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3486544

    authors: Latour G,Georges G,Lamoine LS,Deumié C,Conrath J,Hoffart L

    更新日期:2010-09-01 00:00:00

  • Comparison of cerebral oxygen saturation in premature infants by near-infrared spatially resolved spectroscopy: observations on probe-dependent bias.

    abstract::Spatially resolved spectroscopy (SRS) allows the estimation of absolute tissue oxygen saturation, the ratio of oxygenated to total hemoglobin concentration, which may facilitate the comparison of results among patients. Eighty-two premature infants were included over two years. The cerebral tissue oxygenation index (c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3013454

    authors: Sorensen LC,Leung TS,Greisen G

    更新日期:2008-11-01 00:00:00

  • Reproducibility of parameters of postocclusive reactive hyperemia measured by diffuse optical tomography.

    abstract::The application of near-infrared spectroscopy (NIRS) to assess microvascular function has shown promising results. An important limitation when using a single source-detector pair, however, is the lack of depth sensitivity. Diffuse optical tomography (DOT) overcomes this limitation using an array of sources and detect...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.6.066012

    authors: Vidal-Rosas EE,Billings SA,Chico T,Coca D

    更新日期:2016-06-01 00:00:00

  • Nondestructive imaging of fiber structure in articular cartilage using optical polarization tractography.

    abstract::Collagen fiber orientation plays an important role in determining the structure and function of the articular cartilage. However, there is currently a lack of nondestructive means to image the fiber orientation from the cartilage surface. The purpose of this study is to investigate whether the newly developed optical ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.11.116004

    authors: Yao X,Wang Y,Ravanfar M,Pfeiffer FM,Duan D,Yao G

    更新日期:2016-11-01 00:00:00