Effect of probe pressure on cervical fluorescence spectroscopy measurements.

Abstract:

:Fluorescence spectroscopy is a promising technology for detection of epithelial precancers and cancers. While age and menopausal status influence measurements in the cervix, other variables do not significantly affect the diagnosis. In this study we examine probe pressure as a variable. A fiber optic probe to measure fluorescence spectra at different calibrated levels of pressure was designed and tested. A pilot study was conducted measuring fluorescence excitation emission matrices in 20 patients at light, medium, and firm pressure. Spectroscopic data were pre-processed and analyzed to compare mean peak intensities as a function of pressure. Further statistical analyses tested for differences in intensities at each excitation/emission wavelength pair. Four providers made measurements from 41 sites; 33 yielded good quality spectroscopic data (22 squamous normal, 7 squamous abnormal, 3 columnar normal, 1 transformation zone) from 17 of 20 patients. At all pressure levels, abnormal tissue showed less fluorescence intensity than normal tissue, and post-menopausal patients showed higher fluorescence intensity than premenopausal patients, consistent with previous analyses. A permutation analysis suggests that pressure does not significantly affect fluorescence intensity or lineshape. While other studies are needed to confirm these findings, this study suggests that fluorescence spectroscopy is a robust technology likely not influenced by fiber optic probe pressure.

journal_name

J Biomed Opt

authors

Nath A,Rivoire K,Chang S,Cox D,Atkinson EN,Follen M,Richards-Kortum R

doi

10.1117/1.1695562

subject

Has Abstract

pub_date

2004-05-01 00:00:00

pages

523-33

issue

3

eissn

1083-3668

issn

1560-2281

journal_volume

9

pub_type

临床试验,杂志文章
  • Classifying structural alterations of the cytoskeleton by spectrum enhancement and descriptor fusion.

    abstract::A classifier capable of ranking structural alterations of the cytoskeleton is developed. Images of cytoskeletal microtubules obtained from the epifluorescence microscopy of primary culture rat hepatocytes are analyzed. Morphological descriptors are extracted by contour and mass fractal analysis, direct methods, and sp...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2187423

    authors: Crosta GF,Urani C,Fumarola L

    更新日期:2006-03-01 00:00:00

  • Detection of breast surgical margins with optical coherence tomography imaging: a concept evaluation study.

    abstract::This study aimed to evaluate the concept of using high-resolution optical coherence tomography (OCT) imaging to rapidly assess surgical specimens and determine if cancer positive margins were left behind in the surgical bed. A mouse model of breast cancer was used in this study. Surgical specimens from 30 animals were...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.5.056001

    authors: Savastru D,Chang EW,Miclos S,Pitman MB,Patel A,Iftimia N

    更新日期:2014-05-01 00:00:00

  • Early development of optical low-coherence reflectometry and some recent biomedical applications.

    abstract::This paper explains the term low-coherence interferometry, reviews the early development of optical low-coherence reflectometry, and shows some of the paths that led to the field of biomedical optics. This paper demonstrates that early technical developments in the telecommunications industry resulted in a myriad of t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429914

    authors: Masters BR

    更新日期:1999-04-01 00:00:00

  • Bipolar cellular morphology of malignant melanoma in unstained human melanoma skin tissue.

    abstract::Microstructures of unstained human melanoma skin tissues have been examined by multimodal nonlinear optical microscopy. The polarized shape of the individual melanoma cell can be readily recognized-a phenotype that has been identified in laboratory cultures as characteristic of proliferating melanocytes but has not be...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3120491

    authors: Zhang K,Zhang W,Yang CY,Yang H

    更新日期:2009-03-01 00:00:00

  • In vivo near-infrared dual-axis confocal microendoscopy in the human lower gastrointestinal tract.

    abstract::Near-infrared confocal microendoscopy is a promising technique for deep in vivo imaging of tissues and can generate high-resolution cross-sectional images at the micron-scale. We demonstrate the use of a dual-axis confocal (DAC) near-infrared fluorescence microendoscope with a 5.5-mm outer diameter for obtaining clini...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.2.021102

    authors: Piyawattanametha W,Ra H,Qiu Z,Friedland S,Liu JT,Loewke K,Kino GS,Solgaard O,Wang TD,Mandella MJ,Contag CH

    更新日期:2012-02-01 00:00:00

  • In vivo label-free quantification of liver microcirculation using dual-modality microscopy.

    abstract::Microcirculation lesion is a common symptom of chronic liver diseases in the form of vasculature deformation and circulation alteration. In acute to chronic liver diseases such as biliary atresia, microcirculation lesion can have an early onset. Detection of microcirculation lesion is meaningful for studying the progr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.116006

    authors: Yan J,Kang Y,Xu S,Ong LL,Zhuo S,Bunte RM,Chen N,Asada HH,So PT,Wanless IR,Yu H

    更新日期:2014-01-01 00:00:00

  • Chemical reactivation of fluorescein isothiocyanate immunofluorescence-labeled resin-embedded samples.

    abstract::Resin embedding is widely used and facilitates microscopic imaging of biological tissues. In contrast, quenching of fluorescence during embedding process hinders the application of resin embedding for imaging of fluorescence-labeled samples. For samples expressing fluorescent proteins, it has been demonstrated that th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.2.020501

    authors: Li L,Rao G,Lv X,Chen R,Cheng X,Wang X,Zeng S,Liu X

    更新日期:2018-02-01 00:00:00

  • Infrared spectroscopic imaging of renal tumor tissue.

    abstract::Fourier transform infrared (FTIR) spectroscopic imaging has been used to probe the biochemical composition of human renal tumor tissue and adjacent normal tissue. Freshly resected renal tumor tissue from surgery was prepared as a thin cryosection and examined by FTIR spectroscopic imaging. Tissue types could be discri...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3622292

    authors: Sablinskas V,Urboniene V,Ceponkus J,Laurinavicius A,Dasevicius D,Jankevicius F,Hendrixson V,Koch E,Steiner G

    更新日期:2011-09-01 00:00:00

  • Dependence of image quality on image operator and noise for optical diffusion tomography.

    abstract::By applying linear perturbation theory to the radiation transport equation, the inverse problem of optical diffusion tomography can be reduced to a set of linear equations, Wμ=R, where W is the weight function, μ are the cross-section perturbations to be imaged, and R is the detector readings perturbations. We have st...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429870

    authors: Chang J,Graber HL,Barbour RL

    更新日期:1998-04-01 00:00:00

  • Optical coherence tomography today: speed, contrast, and multimodality.

    abstract::In the last 25 years, optical coherence tomography (OCT) has advanced to be one of the most innovative and most successful translational optical imaging techniques, achieving substantial economic impact as well as clinical acceptance. This is largely owing to the resolution improvements by a factor of 10 to the submic...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.19.7.071412

    authors: Drexler W,Liu M,Kumar A,Kamali T,Unterhuber A,Leitgeb RA

    更新日期:2014-01-01 00:00:00

  • Extraction of optical properties and prediction of light distribution in rat brain tissue.

    abstract::Predicting the distribution of light inside any turbid media, such as biological tissue, requires detailed information about the optical properties of the medium, including the absorption and scattering coefficients and the anisotropy factor. Particularly, in biophotonic applications where photons directly interact wi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.7.075001

    authors: Azimipour M,Baumgartner R,Liu Y,Jacques SL,Eliceiri K,Pashaie R

    更新日期:2014-01-01 00:00:00

  • Intravascular near-infrared fluorescence catheter with ultrasound guidance and blood attenuation correction.

    abstract::Intravascular near-infrared fluorescence (NIRF) imaging offers a new approach for characterizing atherosclerotic plaque, but random catheter positioning within the vessel lumen results in variable light attenuation and can yield inaccurate measurements. We hypothesized that NIRF measurements could be corrected for var...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.5.056009

    authors: Dixon AJ,Hossack JA

    更新日期:2013-05-01 00:00:00

  • Measurement of drug and macromolecule diffusion across atherosclerotic rabbit aorta ex vivo by attenuated total reflection-Fourier transform infrared imaging.

    abstract::Diffusion of two model drugs-benzyl nicotinate and ibuprofen-and the plasma macromolecule albumin across atherosclerotic rabbit aorta was studied ex vivo by attenuated total reflection-Fourier transform infrared (ATR-FTIR) imaging. Solutions of these molecules were applied to the endothelial surface of histological se...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3174395

    authors: Palombo F,Danoux CB,Weinberg PD,Kazarian SG

    更新日期:2009-07-01 00:00:00

  • Stress Relaxation of Porcine Septal Cartilage During Nd:YAG (λ=1.32 μm) Laser Irradiation: Mechanical, Optical, and Thermal Responses.

    abstract::Laser-assisted cartilage reshaping is mediated by thermally induced stress relaxation, and may be used to alter cartilage morphology for reconstructive surgical procedures in the upper airway and face without carving, morselizing, or suturing. Internal stress σ(t), integrated backscattered light intensity I(t) from a ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429896

    authors: Wong BJ,Milner TE,Kim HH,Stuart Nelson J,Sobol EN

    更新日期:1998-10-01 00:00:00

  • Methodology for examining polarized light interactions with tissues and tissuelike media in the exact backscattering direction.

    abstract::The properties of polarized light emerging from turbid media in the exact backscattering direction are studied by modulating the incident light polarization state and isolating the synchronous signal with lock-in amplifier detection. The results are reported for polystyrene microsphere suspensions in distilled water, ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.430004

    authors: Studinski RC,Vitkin IA

    更新日期:2000-07-01 00:00:00

  • Spherical aberration correction in multiphoton fluorescence imaging using objective correction collar.

    abstract::Multiphoton microscopy has evolved into a powerful bioimaging tool in three dimensions. However, the ability to image biological specimens in-depth can be hindered by sample spherical aberration and scattering. These two phenomena can result in the degradation of image resolution and the loss of detected multiphoton s...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1924614

    authors: Lo W,Sun Y,Lin SJ,Jee SH,Dong CY

    更新日期:2005-05-01 00:00:00

  • Quantitative mapping of collagen fiber alignment in thick tissue samples using transmission polarized-light microscopy.

    abstract::Immersion optical clearing makes it possible to use transmission polarized-light microscopy for characterization of thick (200 to 2000  μm) layers of biological tissues. We discuss polarization properties of thick samples in the context of the problem of characterization of collagen fiber alignment in connective tissu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.7.071111

    authors: Yakovlev DD,Shvachkina ME,Sherman MM,Spivak AV,Pravdin AB,Yakovlev DA

    更新日期:2016-07-01 00:00:00

  • Single-cell analysis of dihydroartemisinin-induced apoptosis through reactive oxygen species-mediated caspase-8 activation and mitochondrial pathway in ASTC-a-1 cells using fluorescence imaging techniques.

    abstract::Dihydroartemisinin (DHA), a front-line antimalarial herbal compound, has been shown to possess promising anticancer activity with low toxicity. We have previously reported that DHA induced caspase-3-dependent apoptosis in human lung adenocarcinoma cells. However, the cellular target and molecular mechanism of DHA-indu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3481141

    authors: Lu YY,Chen TS,Wang XP,Li L

    更新日期:2010-07-01 00:00:00

  • Monitoring the reduced scattering coefficient of bone tissues on the trajectory of pedicle screw placement using near-infrared spectroscopy.

    abstract::Pedicle screw (PS) fixation has been widely used for spine diseases. Scientists and clinicians employ several approaches to navigate PS during operation. We have demonstrated the feasibility of monitoring the reduced scattering coefficient (μ's) on the trajectory of PS using near-infrared spectroscopy (NIRS). To perfo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.117002

    authors: Liu Y,Wang Y,Qian Z,Zhao J,Cao X,Li W

    更新日期:2014-01-01 00:00:00

  • Comparison of the sensitivity and image contrast in spontaneous Raman and coherent Stokes Raman scattering microscopy of geometry-controlled samples.

    abstract::We experimentally compare the performance and image contrast of spontaneous Raman and coherent Stokes Raman scattering microscopy. We demonstrate the differences between these techniques on a series of geometry-controlled samples that range in complexity from a point (array of tips) to one-dimensional (line grating) a...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3533310

    authors: Kim H,Michaels CA,Bryant GW,Stranick SJ

    更新日期:2011-02-01 00:00:00

  • Mid-infrared laser measurements of aqueous glucose.

    abstract::Mid-IR semiconductor lasers of two wavelength bands, 5.4 and 9.6 microm, are applied to measure aqueous glucose concentration ranging from 0 to 500 mgdL with Intralipid emulsion (0 to 8%) added as a fat simulator. The absorption coefficient micro(a) is found linear with respect to glucose and Intralipid concentrations...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714283

    authors: Guo B,Wang Y,Wang Y,Le HQ

    更新日期:2007-03-01 00:00:00

  • Cutaneous melanin exhibiting fluorescence emission under near-infrared light excitation.

    abstract::Under ultraviolet and visible light excitation, melanin is essentially a nonfluorescent substance. This work reports our study on near-infrared (NIR) fluorescence properties of melanins, and explores potential applications of NIR fluorescence techniques for evaluating skin disorders involving melanin. The NIR fluoresc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2204007

    authors: Huang Z,Zeng H,Hamzavi I,Alajlan A,Tan E,McLean DI,Lui H

    更新日期:2006-05-01 00:00:00

  • Review of diverse optical fibers used in biomedical research and clinical practice.

    abstract::Optical fiber technology has significantly bolstered the growth of photonics applications in basic life sciences research and in biomedical diagnosis, therapy, monitoring, and surgery. The unique operational characteristics of diverse fibers have been exploited to realize advanced biomedical functions in areas such as...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.19.8.080902

    authors: Keiser G,Xiong F,Cui Y,Shum PP

    更新日期:2014-08-01 00:00:00

  • No-core fiber-based highly sensitive optical fiber pH sensor.

    abstract::The present work describes the fabrication and characterization of an optical fiber pH sensor using a sol–gel technique. The sensing head configuration is incorporated using a short section of no-core fiber, coated with tetraethyl orthosilicate and spliced at the end of a single mode fiber with a bulge. Different type...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.5.057001

    authors: Bhardwaj V,Pathak AK,Singh VK

    更新日期:2017-05-01 00:00:00

  • Application of vibrational spectroscopy to the study of mineralized tissues (review).

    abstract::The infrared and Raman spectroscopy of bone and teeth tissues are reviewed. Characteristic spectra are obtained for both the mineral and protein components of these tissues. Vibrational spectroscopy is used to study the mineralization process, to define the chemical structure changes accompanying bone diseases, and to...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.429994

    authors: Carden A,Morris MD

    更新日期:2000-07-01 00:00:00

  • Real-time oncological guidance using diffuse reflectance spectroscopy in electrosurgery: the effect of coagulation on tissue discrimination.

    abstract::In breast surgery, a lack of knowledge about what is below the tissue surface may lead to positive tumor margins and iatrogenic damage. Diffuse reflectance spectroscopy (DRS) is a spectroscopic technique that can distinguish between healthy and tumor tissue making it a suitable technology for intraoperative guidance. ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.11.115004

    authors: Adank MW,Fleischer JC,Dankelman J,Hendriks BHW

    更新日期:2018-11-01 00:00:00

  • Surface plasmon-based infrared spectroscopy for cell biosensing.

    abstract::Cell morphology is often used as a valuable indicator of the physical condition and general status of living cells. We demonstrate a noninvasive method for morphological characterization of adherent cells. We measure infrared reflectivity spectrum at oblique angle from living cells cultured on thin Au film, and utiliz...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.081409

    authors: Yashunsky V,Lirtsman V,Zilbershtein A,Bein A,Schwartz B,Aroeti B,Golosovsky M,Davidov D

    更新日期:2012-08-01 00:00:00

  • Optical properties of adenocarcinoma and squamous cell carcinoma of the gastroesophageal junction.

    abstract::Photodynamic therapy (PDT) is an alternative to radical surgical resection for T1a or nonresectable carcinomas of the gastroesophageal junction. Besides the concentration of the photosensitizer, the light distribution in tissue is responsible for tumor destruction. For this reason, knowledge about the behavior of ligh...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2564793

    authors: Holmer C,Lehmann KS,Wanken J,Reissfelder C,Roggan A,Mueller G,Buhr HJ,Ritz JP

    更新日期:2007-01-01 00:00:00

  • Use of picosecond Kerr-gated Raman spectroscopy to suppress signals from both surface and deep layers in bladder and prostate tissue.

    abstract::Raman spectroscopy is an optical technique able to interrogate biological tissues, giving us an understanding of the changes in molecular structure that are associated with disease development. The Kerr-gated Raman spectroscopy technique uses a picosecond pulsed laser as well as fast temporal gating of collected Raman...

    journal_title:Journal of biomedical optics

    pub_type: 临床试验,杂志文章

    doi:10.1117/1.1991848

    authors: Prieto MC,Matousek P,Towrie M,Parker AW,Wright M,Ritchie AW,Stone N

    更新日期:2005-07-01 00:00:00

  • Comparison of time-resolved and continuous-wave near-infrared techniques for measuring cerebral blood flow in piglets.

    abstract::A primary focus of neurointensive care is monitoring the injured brain to detect harmful events that can impair cerebral blood flow (CBF), resulting in further injury. Since current noninvasive methods used in the clinic can only assess blood flow indirectly, the goal of this research is to develop an optical techniqu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3488626

    authors: Diop M,Tichauer KM,Elliott JT,Migueis M,Lee TY,St Lawrence K

    更新日期:2010-09-01 00:00:00