Spherical aberration correction in multiphoton fluorescence imaging using objective correction collar.

Abstract:

:Multiphoton microscopy has evolved into a powerful bioimaging tool in three dimensions. However, the ability to image biological specimens in-depth can be hindered by sample spherical aberration and scattering. These two phenomena can result in the degradation of image resolution and the loss of detected multiphoton signal. In this work, we use the correction collar (for cover glass thickness) associated with a water immersion objective in an attempt to improve multiphoton imaging. In the two samples we examined (human skin and rat tail tendon), we found that while the improvement in image resolution was not visible qualitatively, the measured axial fluorescence or second harmonic generation signal profiles indicate that the use of the correction collar can help to improve the detected multiphoton signals. The maximum increases are 36% and 57% for the skin (sulforhodamine B fluorescence) and tendon (second harmonic generation) specimens, respectively. Our result shows that for in-depth multiphoton imaging, the correction collar may be used to correct for spherical aberration. However, each tissue type needs to be examined to determine the optimal correction collar setting to be used.

journal_name

J Biomed Opt

authors

Lo W,Sun Y,Lin SJ,Jee SH,Dong CY

doi

10.1117/1.1924614

subject

Has Abstract

pub_date

2005-05-01 00:00:00

pages

034006

issue

3

eissn

1083-3668

issn

1560-2281

journal_volume

10

pub_type

杂志文章
  • Photoacoustic needle: minimally invasive guidance to biopsy.

    abstract::We introduce a needle probe based on photoacoustics (PA) to extend the scope of optical needle methods in guiding biopsies. Pulsed light is coupled to an optical fiber in a needle to be inserted in tissue, and PA signals are detected using an ultrasound imager used for needle guidance. This PA needle samples large vol...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.7.070502

    authors: Piras D,Grijsen C,Schütte P,Steenbergen W,Manohar S

    更新日期:2013-07-01 00:00:00

  • Comparison of the sensitivity and image contrast in spontaneous Raman and coherent Stokes Raman scattering microscopy of geometry-controlled samples.

    abstract::We experimentally compare the performance and image contrast of spontaneous Raman and coherent Stokes Raman scattering microscopy. We demonstrate the differences between these techniques on a series of geometry-controlled samples that range in complexity from a point (array of tips) to one-dimensional (line grating) a...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3533310

    authors: Kim H,Michaels CA,Bryant GW,Stranick SJ

    更新日期:2011-02-01 00:00:00

  • Analyzing near-infrared scattering from human skin to monitor changes in hematocrit.

    abstract::Probing tissue with near-infrared radiation (NIR) simultaneously produces remitted fluorescence and Raman scattering (IE) plus Rayleigh∕Mie light scattering (EE) that noninvasively give chemical and physical information about the materials and objects within. We model tissue as a three-phase system: plasma and red blo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3625283

    authors: Chaiken J,Deng B,Goodisman J,Shaheen G,Bussjager RJ

    更新日期:2011-09-01 00:00:00

  • Quantitative measurement of reactive oxygen species in vivo by utilizing a novel method: chemiluminescence with an internal fluorescence as reference.

    abstract::Reactive oxygen species (ROS) produced by photodynamic therapy (PDT) is recorded in vivo using a chemiluminescence (CL)-based gated optical system. A novel approach is developed to utilize the fluorescence (FL) of the CL probe as an internal fluorescence to calibrate the observed CL on pharmacokinetics of the probe in...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3368688

    authors: Wei Y,Xing D,Luo S,Yang L,Chen Q

    更新日期:2010-03-01 00:00:00

  • Near-infrared fluorescence goggle system with complementary metal-oxide-semiconductor imaging sensor and see-through display.

    abstract::We have developed a near-infrared (NIR) fluorescence goggle system based on the complementary metal-oxide-semiconductor active pixel sensor imaging and see-through display technologies. The fluorescence goggle system is a compact wearable intraoperative fluorescence imaging and display system that can guide surgery in...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.10.101303

    authors: Liu Y,Njuguna R,Matthews T,Akers WJ,Sudlow GP,Mondal S,Tang R,Gruev V,Achilefu S

    更新日期:2013-10-01 00:00:00

  • Imaging performance of a miniature integrated microendoscope.

    abstract::An integrated miniature multi-modal microscope (4M device) for microendoscopy was built and tested. Imaging performance is evaluated and imaging results are presented for both fluorescence and reflectance samples. Images of biological samples show successful imaging of both thin layers of fixed cells prepared on a sli...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2978060

    authors: Rogers JD,Landau S,Tkaczyk TS,Descour MR,Rahman MS,Richards-Kortum R,Kärkäinen AH,Christenson T

    更新日期:2008-09-01 00:00:00

  • High temperature heat source generation with quasi-continuous wave semiconductor lasers at power levels of 6 W for medical use.

    abstract::We investigate a technology to create a high temperature heat source on the tip surface of the glass fiber proposed for medical surgery applications. Using 4 to 6 W power level semiconductor lasers at a wavelength of 980 nm, a laser coupled fiber tip was preprocessed to contain a certain amount of titanium oxide powde...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.101502

    authors: Fujimoto T,Imai Y,Tei K,Ito S,Kanazawa H,Yamaguchi S

    更新日期:2014-01-01 00:00:00

  • Mechanically switchable polymer fibers for sensing in biological conditions.

    abstract::The area of in vivo sensing using optical fibers commonly uses materials such as silica and polymethyl methacrylate, both of which possess much higher modulus than human tissue. The mechanical mismatch between materials and living tissue has been seen to cause higher levels of glial encapsulation, scarring, and inflam...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.2.027001

    authors: McMillan S,Rader C,Jorfi M,Pickrell G,Foster EJ

    更新日期:2017-02-01 00:00:00

  • Mueller matrix decomposition for determination of optical rotation of glucose molecules in turbid media.

    abstract::The optical activity of glucose molecules is important for diagnosing and monitoring blood glucose of diabetes. In order to accurately detect the diabetes at an early stage, there is an urgent need to develop innovative detection methods. By use of Mueller matrix decomposition (MMD), we have studied the optical activi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.4.046015

    authors: Sun P,Ma Y,Liu W,Yang Q,Jia Q

    更新日期:2014-04-01 00:00:00

  • Quantitative microscopy and nanoscopy of sickle red blood cells performed by wide field digital interferometry.

    abstract::We have applied wide-field digital interferometry (WFDI) to examine the morphology and dynamics of live red blood cells (RBCs) from individuals who suffer from sickle cell anemia (SCA), a genetic disorder that affects the structure and mechanical properties of RBCs. WFDI is a noncontact, label-free optical microscopy ...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3556717

    authors: Shaked NT,Satterwhite LL,Telen MJ,Truskey GA,Wax A

    更新日期:2011-03-01 00:00:00

  • Analysis of the dispersion compensation of acousto-optic deflectors used for multiphoton imaging.

    abstract::The acousto-optic deflector (AOD) is highly preferred in laser scanning microscopy for its fast scanning ability and random-addressing capability. However, its application in two-photon microscopy is frustrated by the dispersion of the AOD, which results in beam distortion and pulse lengthening. We report the analysis...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714061

    authors: Zeng S,Lv X,Bi K,Zhan C,Li D,Chen WR,Xiong W,Jacques SL,Luo Q

    更新日期:2007-03-01 00:00:00

  • Autofluorescence of epithelial tissue: single-photon versus two-photon excitation.

    abstract::We instrumented a combined fluorescence spectroscopy and imaging system to characterize the single- and two-photon excited autofluorescence in epithelial tissue. Single-photon fluorescence (SPF) are compared with two-photon fluorescence (TPF) measured at the same location in epithelial tissue. It was found that the SP...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2975866

    authors: Zheng W,Wu Y,Li D,Qu JY

    更新日期:2008-09-01 00:00:00

  • Three-dimensional optical coherence tomography at 1050 nm versus 800 nm in retinal pathologies: enhanced performance and choroidal penetration in cataract patients.

    abstract::Frequency domain optical coherence tomography (FD-OCT), based on an all-reflective high-speed InGaAs spectrometer, operating in the 1050 nm wavelength region for retinal diagnostics, enables high-speed, volumetric imaging of retinal pathologies with greater penetration into choroidal tissue is compared to conventional...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2773728

    authors: Povazay B,Hermann B,Unterhuber A,Hofer B,Sattmann H,Zeiler F,Morgan JE,Falkner-Radler C,Glittenberg C,Blinder S,Drexler W

    更新日期:2007-07-01 00:00:00

  • In vivo assessment and evaluation of lung tissue morphologic and physiological changes from non-contact endoscopic reflectance spectroscopy for improving lung cancer detection.

    abstract::We present a method for lung cancer detection exploiting reflectance spectra measured in vivo during endoscopic imaging of the lung. The measured reflectance spectra were analyzed using a specially developed light-transport model to obtain quantitative information about cancer-related, physiological, and morphologic c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2337529

    authors: Fawzy YS,Petek M,Tercelj M,Zeng H

    更新日期:2006-07-01 00:00:00

  • Spectrally resolved fluorescence lifetime imaging to investigate cell metabolism in malignant and nonmalignant oral mucosa cells.

    abstract::Fluorescence-guided diagnosis of tumor tissue is in many cases insufficient, because false positive results interfere with the outcome. Improvement through observation of cell metabolism might offer the solution, but needs a detailed understanding of the origin of autofluorescence. With respect to this, spectrally res...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.9.096005

    authors: Rück A,Hauser C,Mosch S,Kalinina S

    更新日期:2014-09-01 00:00:00

  • Calibration of diffuse correlation spectroscopy blood flow index with venous-occlusion diffuse optical spectroscopy in skeletal muscle.

    abstract::We investigate and assess the utility of a simple scheme for continuous absolute blood flow monitoring based on diffuse correlation spectroscopy (DCS). The scheme calibrates DCS using venous-occlusion diffuse optical spectroscopy (VO-DOS) measurements of arm muscle tissue at a single time-point. A calibration coeffici...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.12.125005

    authors: Li Z,Baker WB,Parthasarathy AB,Ko TS,Wang D,Schenkel S,Durduran T,Li G,Yodh AG

    更新日期:2015-01-01 00:00:00

  • Continuous-wave circular polarization terahertz imaging.

    abstract::Biomedical applications of terahertz (THz) radiation are appealing because THz radiation is nonionizing and has the demonstrated ability to detect intrinsic contrasts between cancerous and normal tissue. A linear polarization-sensitive detection technique for tumor margin delineation has already been demonstrated; how...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.7.070502

    authors: Martin JP,Joseph CS,Giles RH

    更新日期:2016-07-01 00:00:00

  • Rise of Raman spectroscopy in neurosurgery: a review.

    abstract:SIGNIFICANCE:Although the clinical potential for Raman spectroscopy (RS) has been anticipated for decades, it has only recently been used in neurosurgery. Still, few devices have succeeded in making their way into the operating room. With recent technological advancements, however, vibrational sensing is poised to be a...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.5.050901

    authors: DePaoli D,Lemoine É,Ember K,Parent M,Prud'homme M,Cantin L,Petrecca K,Leblond F,Côté DC

    更新日期:2020-05-01 00:00:00

  • Biocompatible semiconductor optoelectronics.

    abstract::We investigate optoelectronic properties of integrated structures comprising semiconductor light-emitting materials for optical probes of microscopic biological systems. Compound semiconductors are nearly ideal light emitters for probing cells and other microorganisms because of their spectral match to the transparenc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1506931

    authors: Gourley PL,Copeland RG,Cox JD,Hendricks JK,McDonald AE,Peterson SL,Sasaki DY

    更新日期:2002-10-01 00:00:00

  • Design and validation of an angle-resolved low-coherence interferometry fiber probe for in vivo clinical measurements of depth-resolved nuclear morphology.

    abstract::We present a novel Fourier-domain angle-resolved low-coherence interferometry (a /LCI) fiber probe designed for in vivo clinical application in gastrointestinal endoscopy. The a/LCI technique measures the depth-resolved angular scattering distribution to determine the size distribution and optical density of cell nucl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3520130

    authors: Zhu Y,Terry NG,Woosley JT,Shaheen NJ,Wax A

    更新日期:2011-01-01 00:00:00

  • Bleaching of plasmon-resonance absorption of gold nanorods decreases efficiency of cell destruction.

    abstract::When irradiated with nanosecond laser pulses, gold nanoparticles allow for manipulation or destruction of cells and proteins with high spatial and temporal precision. Gold nanorods are especially attractive, because they have an up-to-20-fold stronger absorption than a sphere of equal volume, which is shifted to the o...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.5.058003

    authors: Rudnitzki F,Bever M,Rahmanzadeh R,Brieger K,Endl E,Groll J,Hüttmann G

    更新日期:2012-05-01 00:00:00

  • Real-time in vivo photoacoustic and ultrasound imaging.

    abstract::A real-time photoacoustic imaging system is designed and built. This system is based on a commercially available ultrasound imaging system. It can achieve a frame rate of 8 frames/sec. Vasculature in the hand of a human volunteer is imaged, and the resulting photoacoustic image is combined with the ultrasound image. T...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3005421

    authors: Kolkman RG,Brands PJ,Steenbergen W,van Leeuwen TG

    更新日期:2008-09-01 00:00:00

  • Noncontact spirometry with a webcam.

    abstract::We present an imaging-based method for noncontact spirometry. The method tracks the subtle respiratory-induced shoulder movement of a subject, builds a calibration curve, and determines the flow-volume spirometry curve and vital respiratory parameters, including forced expiratory volume in the first second, forced vit...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.5.057002

    authors: Liu C,Yang Y,Tsow F,Shao D,Tao N

    更新日期:2017-05-01 00:00:00

  • Integration of a Raman spectroscopy system to a robotic-assisted surgical system for real-time tissue characterization during radical prostatectomy procedures.

    abstract::Surgical excision of the whole prostate through a radical prostatectomy procedure is part of the standard of care for prostate cancer. Positive surgical margins (cancer cells having spread into surrounding nonresected tissue) occur in as many as 1 in 5 cases and strongly correlate with disease recurrence and the requi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.2.025001

    authors: Pinto M,Zorn KC,Tremblay JP,Desroches J,Dallaire F,Aubertin K,Marple E,Kent C,Leblond F,Trudel D,Lesage F

    更新日期:2019-02-01 00:00:00

  • Using ultrahigh sensitive optical microangiography to achieve comprehensive depth resolved microvasculature mapping for human retina.

    abstract::This paper presents comprehensive and depth-resolved retinal microvasculature images within human retina achieved by a newly developed ultrahigh sensitive optical microangiography (UHS-OMAG) system. Due to its high flow sensitivity, UHS-OMAG is much more sensitive to tissue motion due to the involuntary movement of th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3642638

    authors: An L,Shen TT,Wang RK

    更新日期:2011-10-01 00:00:00

  • Molecular imaging of epidermal growth factor receptor in live cells with refractive index sensitivity using dark-field microspectroscopy and immunotargeted nanoparticles.

    abstract::We present a study using plasmonic nanoparticles (NPs) to image epidermal growth factor receptor (EGFR) in live cells. Through detailed analysis of the NP scattering spectra, we determine the intracellular refractive index (RI) within attoliter volumes inside of the living cells. Molecular imaging is demonstrated usin...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2837450

    authors: Curry AC,Crow M,Wax A

    更新日期:2008-01-01 00:00:00

  • Monitoring of tumor response to cisplatin by subsurface fluorescence molecular tomography.

    abstract::Subsurface fluorescence molecular tomography (FMT) has promising potential for noninvasive characterization of molecular and cellular activities in small animals by tomographic means in reflectance geometry. In this work, subsurface FMT is employed to monitor the therapeutic response of cisplatin in tumor-bearing mice...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.17.4.040504

    authors: Liu F,Cao X,He W,Song J,Dai Z,Zhang B,Luo J,Li Y,Bai J

    更新日期:2012-04-01 00:00:00

  • Antibody-based magnetic nanoparticle immunoassay for quantification of Alzheimer's disease pathogenic factor.

    abstract::Alzheimer's disease (AD) is a neurodegenerative disorder that leads to a decline in cognitive and intellectual abilities and an irreversible mental deterioration. Based on multidisciplinary AD research, the most universally accepted hypotheses on AD pathogenesis are the intracerebral aggregate formation of beta-amyloi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.5.051205

    authors: Kim CB,Choi YY,Song WK,Song KB

    更新日期:2014-05-01 00:00:00

  • Raman biophysical markers in skin cancer diagnosis.

    abstract::Raman spectroscopy (RS) has demonstrated great potential for in vivo cancer screening; however, the biophysical changes that occur for specific diagnoses remain unclear. We recently developed an inverse biophysical skin cancer model to address this issue. Here, we presented the first demonstration of in vivo melanoma ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.5.057002

    authors: Feng X,Moy AJ,Nguyen HTM,Zhang Y,Zhang J,Fox MC,Sebastian KR,Reichenberg JS,Markey MK,Tunnell JW

    更新日期:2018-05-01 00:00:00

  • Evans blue dye-enhanced capillary-resolution photoacoustic microscopy in vivo.

    abstract::Complete and continuous imaging of microvascular networks is crucial for a wide variety of biomedical applications. Photoacoustic tomography can provide high resolution microvascular imaging using hemoglobin within red blood cells (RBCs) as an endogenic contrast agent. However, intermittent RBC flow in capillaries res...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3251044

    authors: Yao J,Maslov K,Hu S,Wang LV

    更新日期:2009-09-01 00:00:00