In vivo assessment and evaluation of lung tissue morphologic and physiological changes from non-contact endoscopic reflectance spectroscopy for improving lung cancer detection.

Abstract:

:We present a method for lung cancer detection exploiting reflectance spectra measured in vivo during endoscopic imaging of the lung. The measured reflectance spectra were analyzed using a specially developed light-transport model to obtain quantitative information about cancer-related, physiological, and morphologic changes in the superficial bronchial mucosa layers. The light-transport model allowed us to obtain the absorption coefficient (mua) and further to derive the micro-vascular blood volume fraction in tissue and the tissue blood oxygen saturation. The model also allowed us to obtain the scattering coefficient (mus) and the anisotropy coefficient (g) and further to derive the tissue scattering micro-particle volume fraction and size distribution. The specular component of the reflectance signal and the instrument response were accounted for during the analysis. The method was validated using 100 reflectance spectra measured in vivo in a noncontact fashion from 22 lung patients (50 normal tissue/benign lesion sites and 50 malignant lesion sites). The classification between normal tissue/benign lesions and malignant lesions was further investigated using the derived quantitative parameters and discriminant function analysis. The results demonstrated significant differences between the normal tissue/benign lesions and the malignant lesions in terms of tissue blood volume fraction, blood oxygen saturation, tissue scatterer volume fractions, and size distribution. The results also showed that the malignant lung lesions can be differentiated from normal tissue/benign lesions with both diagnostic sensitivity and specificity of better than 80%.

journal_name

J Biomed Opt

authors

Fawzy YS,Petek M,Tercelj M,Zeng H

doi

10.1117/1.2337529

subject

Has Abstract

pub_date

2006-07-01 00:00:00

pages

044003

issue

4

eissn

1083-3668

issn

1560-2281

journal_volume

11

pub_type

杂志文章
  • Imaging and tracking HIV viruses in human cervical mucus.

    abstract::We describe a systematic approach to image, track, and quantify the movements of HIV viruses embedded in human cervical mucus. The underlying motivation for this study is that, in HIV-infected adults, women account for more than half of all new cases and most of these women acquire the infection through heterosexual c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.9.096001

    authors: Boukari F,Makrogiannis S,Nossal R,Boukari H

    更新日期:2016-09-01 00:00:00

  • Tutorial on diffuse light transport.

    abstract::A tutorial introduction to diffuse light transport is presented. The basic analytic equations of time-resolved, steady-state and modulated light transport are introduced. The perturbation method for handling slight heterogeneities in optical properties is outlined. The treatment of boundary conditions such as an air/t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2967535

    authors: Jacques SL,Pogue BW

    更新日期:2008-07-01 00:00:00

  • Waveguide evanescent field fluorescence microscopy: high contrast imaging of a domain forming mixed lipid Langmuir-Blodgett monolayer mimicking lung surfactant.

    abstract::Waveguide evanescent field fluorescence (WEFF) microscopy is a new development that allows the imaging of contact regions between biological cells and their substratum, as well as imaging of ultrathin films such as monomolecular Langmuir-Blodgett (LB) films. Mixed-lipid monolayer systems mimicking lung surfactant were...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3569095

    authors: Hassanzadeh A,Mittler S

    更新日期:2011-04-01 00:00:00

  • Comparative evaluation of differential laser-induced perturbation spectroscopy as a technique to discriminate emerging skin pathology.

    abstract::Fluorescence spectroscopy has been widely investigated as a technique for identifying pathological tissue; however, unrelated subject-to-subject variations in spectra complicate data analysis and interpretation. We describe and evaluate a new biosensing technique, differential laser-induced perturbation spectroscopy (...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.6.067002

    authors: Kozikowski RT,Smith SE,Lee JA,Castleman WL,Sorg BS,Hahn DW

    更新日期:2012-06-01 00:00:00

  • Properties of contact pressure induced by manually operated fiber-optic probes.

    abstract::We assess the properties of contact pressure applied by manually operated fiber-optic probes as a function of the operator, probe contact area, and sample stiffness. First, the mechanical properties of human skin sites with different skin structures, thicknesses, and underlying tissues were studied by in vivo indentat...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.12.127002

    authors: Bregar M,Cugmas B,Naglic P,Hartmann D,Pernuš F,Likar B,Bürmen M

    更新日期:2015-01-01 00:00:00

  • Retinal response of Macaca mulatta to picosecond laser pulses of varying energy and spot size.

    abstract::We investigate the relationship between the laser beam at the retina (spot size) and the extent of retinal injury from single ultrashort laser pulses. From previous studies it is believed that the retinal effect of single 3-ps laser pulses should vary in extent and location, depending on the occurrence of laser-induce...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1805554

    authors: Roach WP,Cain CP,Narayan DG,Noojin GD,Boppart SA,Birngruber R,Fujimoto JG,Toth CA

    更新日期:2004-11-01 00:00:00

  • Change of tumor vascular reactivity during tumor growth and postchemotherapy observed by near-infrared spectroscopy.

    abstract::Breast cancer is one of the most common cancers in females. To monitor chemotherapeutic efficacy for breast cancer, medical imaging systems such as x-ray mammography, computed tomography, magnetic resonance imaging, and ultrasound imaging have been used. Currently, it can take up to 3 to 6 weeks to see the tumor respo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.12.121603

    authors: Lee S,Jeong H,Seong M,Kim JG

    更新日期:2017-12-01 00:00:00

  • Simultaneous imaging of multiple focal planes for three-dimensional microscopy using ultra-high-speed adaptive optics.

    abstract::Traditional white-light and fluorescent imaging techniques provide powerful methods to extract high-resolution information from two-dimensional (2-D) sections, but to retrieve information from a three-dimensional (3-D) volume they require relatively slow scanning methods that result in increased acquisition time. Usin...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.17.5.050505

    authors: Duocastella M,Sun B,Arnold CB

    更新日期:2012-05-01 00:00:00

  • Performance assessment of time-domain optical brain imagers, part 2: nEUROPt protocol.

    abstract::The nEUROPt protocol is one of two new protocols developed within the European project nEUROPt to characterize the performances of time-domain systems for optical imaging of the brain. It was applied in joint measurement campaigns to compare the various instruments and to assess the impact of technical improvements. T...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.8.086012

    authors: Wabnitz H,Jelzow A,Mazurenka M,Steinkellner O,Macdonald R,Milej D,Żołek N,Kacprzak M,Sawosz P,Maniewski R,Liebert A,Magazov S,Hebden J,Martelli F,Di Ninni P,Zaccanti G,Torricelli A,Contini D,Re R,Zucchelli L,Spine

    更新日期:2014-08-01 00:00:00

  • Anatomical image-guided fluorescence molecular tomography reconstruction using kernel method.

    abstract::Fluorescence molecular tomography (FMT) is an important in vivo imaging modality to visualize physiological and pathological processes in small animals. However, FMT reconstruction is ill-posed and ill-conditioned due to strong optical scattering in deep tissues, which results in poor spatial resolution. It is well kn...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.5.055001

    authors: Baikejiang R,Zhao Y,Fite BZ,Ferrara KW,Li C

    更新日期:2017-05-01 00:00:00

  • Evaluating the use of optical coherence tomography for the detection of epithelial cancers in vitro.

    abstract::Optical coherence tomography (OCT) is a noninvasive imaging methodology that is able to image tissue to depths of over 1 mm. Many epithelial conditions, such as melanoma and oral cancers, require an invasive biopsy for diagnosis. A noninvasive, real-time, point of care method of imaging depth-resolved epithelial struc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3652708

    authors: Smith LE,Hearnden V,Lu Z,Smallwood R,Hunter KD,Matcher SJ,Thornhill MH,Murdoch C,MacNeil S

    更新日期:2011-11-01 00:00:00

  • Reflection spectroscopy of atherosclerotic plaque.

    abstract::Heart disease is the primary cause of death in the western world. Many of these deaths are caused by the rupture of vulnerable plaque. Vulnerable plaques are characterized by a large lipid core covered by a thin fibrous cap. One method for detecting these plaques is reflection spectroscopy. Several studies have invest...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2186332

    authors: Lilledahl MB,Haugen OA,Barkost M,Svaasand LO

    更新日期:2006-03-01 00:00:00

  • Comparison of the sensitivity and image contrast in spontaneous Raman and coherent Stokes Raman scattering microscopy of geometry-controlled samples.

    abstract::We experimentally compare the performance and image contrast of spontaneous Raman and coherent Stokes Raman scattering microscopy. We demonstrate the differences between these techniques on a series of geometry-controlled samples that range in complexity from a point (array of tips) to one-dimensional (line grating) a...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3533310

    authors: Kim H,Michaels CA,Bryant GW,Stranick SJ

    更新日期:2011-02-01 00:00:00

  • Multiwavelength time-resolved detection of fluorescence during the inflow of indocyanine green into the adult's brain.

    abstract::Optical technique based on diffuse reflectance measurement combined with indocyanine green (ICG) bolus tracking is extensively tested as a method for clinical assessment of brain perfusion in adults at the bedside. Methodology of multiwavelength and time-resolved detection of fluorescence light excited in the ICG is p...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.087001

    authors: Gerega A,Milej D,Weigl W,Botwicz M,Zolek N,Kacprzak M,Wierzejski W,Toczylowska B,Mayzner-Zawadzka E,Maniewski R,Liebert A

    更新日期:2012-08-01 00:00:00

  • Optical fiber Bragg grating-instrumented silicone liner for interface pressure measurement within prosthetic sockets of lower-limb amputees.

    abstract::This paper presents a fiber Bragg grating (FBG)-instrumented prosthetic silicone liner that provides cushioning for the residual limb and can successfully measure interface pressures inside prosthetic sockets of lower-limb amputees in a simple and practical means of sensing. The liner is made of two silicone layers be...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.8.087001

    authors: Al-Fakih E,Arifin N,Pirouzi G,Mahamd Adikan FR,Shasmin HN,Abu Osman NA

    更新日期:2017-08-01 00:00:00

  • Unsupervised analysis of small animal dynamic Cerenkov luminescence imaging.

    abstract::Clustering analysis (CA) and principal component analysis (PCA) were applied to dynamic Cerenkov luminescence images (dCLI). In order to investigate the performances of the proposed approaches, two distinct dynamic data sets obtained by injecting mice with (32)P-ATP and (18)F-FDG were acquired using the IVIS 200 optic...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3663442

    authors: Spinelli AE,Boschi F

    更新日期:2011-12-01 00:00:00

  • Characterization of the Cerenkov scatter function: a convolution kernel for Cerenkov light dosimetry.

    abstract::Cerenkov light is created in clinical applications involving high-energy radiation such as in radiation therapy. There is considerable interest in using Cerenkov light as a means to perform in vivo dosimetry during radiation therapy; however, a better understanding of the light-to-dose relationship is needed. One such...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.10.105007

    authors: Brost E,Watanabe Y

    更新日期:2018-10-01 00:00:00

  • Mapping local optical axis in birefringent samples using polarization-sensitive optical coherence tomography.

    abstract::An algorithm was developed to obtain depth-resolved local optical axis in birefringent samples by using conventional polarization-sensitive optical coherence tomography (PSOCT) that uses a single circularly polarized incident light. The round-trip sample Jones matrices were first constructed from the cumulative PSOCT ...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.17.11.110501

    authors: Fan C,Yao G

    更新日期:2012-11-01 00:00:00

  • Monte Carlo modeling of light propagation in the human head for applications in sinus imaging.

    abstract::Sinus blockages are a common reason for physician visits, affecting one out of seven people in the United States, and often require medical treatment. Diagnosis in the primary care setting is challenging because symptom criteria (via detailed clinical history) plus objective imaging [computed tomography (CT) or endosc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.3.035004

    authors: Cerussi AE,Mishra N,You J,Bhandarkar N,Wong B

    更新日期:2015-03-01 00:00:00

  • Self-mixing in a diode laser as a method for cardiovascular diagnostics.

    abstract::Our aim is the development of a simple optical method for pulse wave profile, pulse wave delay time, and blood flow measurement. The method is based on recording the Doppler frequency shift related to a moving target--blood vessel walls or small particles. The Doppler signal is detected using the self-mixing that occu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1528949

    authors: Meigas K,Hinrikus H,Kattai R,Lass J

    更新日期:2003-01-01 00:00:00

  • Transmission versus reflectance spectroscopy for quantitation.

    abstract::The objective of this work was to compare the accuracy of analyte concentration estimation when using transmission versus diffuse reflectance spectroscopy of a scattering medium. Monte Carlo ray tracing of light through the medium was used in conjunction with pure component absorption spectra and Beer-Lambert absorpti...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.1.018001

    authors: Gardner CM

    更新日期:2018-01-01 00:00:00

  • High temperature heat source generation with quasi-continuous wave semiconductor lasers at power levels of 6 W for medical use.

    abstract::We investigate a technology to create a high temperature heat source on the tip surface of the glass fiber proposed for medical surgery applications. Using 4 to 6 W power level semiconductor lasers at a wavelength of 980 nm, a laser coupled fiber tip was preprocessed to contain a certain amount of titanium oxide powde...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.101502

    authors: Fujimoto T,Imai Y,Tei K,Ito S,Kanazawa H,Yamaguchi S

    更新日期:2014-01-01 00:00:00

  • Molecular interactions of exogenous chemical agents with collagen--implications for tissue optical clearing.

    abstract::Reduction of optical scattering in turbid biological tissues using nonreactive chemical agents has potential applications for light-based diagnostics and therapeutics. Optical clearing effects by exogenous chemical agents, in particular sugars and sugar alcohols, have been found to be temporary with tissue rehydration...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.2166381

    authors: Yeh AT,Hirshburg J

    更新日期:2006-01-01 00:00:00

  • Clinical study of noninvasive in vivo melanoma and nonmelanoma skin cancers using multimodal spectral diagnosis.

    abstract::The goal of this study was to determine the diagnostic capability of a multimodal spectral diagnosis (SD) for in vivo noninvasive disease diagnosis of melanoma and nonmelanoma skin cancers. We acquired reflectance, fluorescence, and Raman spectra from 137 lesions in 76 patients using custom-built optical fiber-based c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.117003

    authors: Lim L,Nichols B,Migden MR,Rajaram N,Reichenberg JS,Markey MK,Ross MI,Tunnell JW

    更新日期:2014-01-01 00:00:00

  • Investigation of nuclear nano-morphology marker as a biomarker for cancer risk assessment using a mouse model.

    abstract::The development of accurate and clinically applicable tools to assess cancer risk is essential to define candidates to undergo screening for early-stage cancers at a curable stage or provide a novel method to monitor chemoprevention treatments. With the use of our recently developed optical technology--spatial-domain ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.6.066014

    authors: Bista RK,Uttam S,Hartman DJ,Qiu W,Yu J,Zhang L,Brand RE,Liu Y

    更新日期:2012-06-01 00:00:00

  • Design of synchrotron light source and its beamline dedicated to dual-energy x-ray computed tomography.

    abstract::A synchrotron light source dedicated to medical applications has been designed at National Institute of Radiological Sciences. The storage ring, with circumference of 80 m, is designed for acceleration of 2.3 GeV and a stored current of 420 mA. It is equipped with two multipole wigglers to produce sufficient photon fl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1383062

    authors: Torikoshi M,Tsunoo T,Endo M,Noda K,Kumada M,Yamada S,Soga F,Hyodo K

    更新日期:2001-07-01 00:00:00

  • Using thermographic cameras to investigate eye temperature and clinical severity in depression.

    abstract::Previous studies suggest that altered corneal temperature may be a feature of schizophrenia, but the association between major depressive disorder (MDD) and corneal temperature has yet to be assessed. The aim of this study is to investigate whether eye temperature is different among MDD patients than among healthy ind...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.2.026001

    authors: Maller JJ,George SS,Viswanathan RP,Fitzgerald PB,Junor P

    更新日期:2016-02-01 00:00:00

  • Comparison of time-resolved and continuous-wave near-infrared techniques for measuring cerebral blood flow in piglets.

    abstract::A primary focus of neurointensive care is monitoring the injured brain to detect harmful events that can impair cerebral blood flow (CBF), resulting in further injury. Since current noninvasive methods used in the clinic can only assess blood flow indirectly, the goal of this research is to develop an optical techniqu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3488626

    authors: Diop M,Tichauer KM,Elliott JT,Migueis M,Lee TY,St Lawrence K

    更新日期:2010-09-01 00:00:00

  • Quantitative polarized Raman spectroscopy in highly turbid bone tissue.

    abstract::Polarized Raman spectroscopy allows measurement of molecular orientation and composition and is widely used in the study of polymer systems. Here, we extend the technique to the extraction of quantitative orientation information from bone tissue, which is optically thick and highly turbid. We discuss multiple scatteri...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3426310

    authors: Raghavan M,Sahar ND,Wilson RH,Mycek MA,Pleshko N,Kohn DH,Morris MD

    更新日期:2010-05-01 00:00:00

  • In vitro detection and quantification of enamel and root caries using infrared photothermal radiometry and modulated luminescence.

    abstract::Artificially created demineralized and remineralized carious lesions on the root and enamel of human teeth were examined by photothermal radiometry (PTR) and modulated luminescence (LUM). Fourteen extracted human teeth were used and a lesion was created on a 1 mmx4 mm rectangular window, spanning root to enamel, using...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2942374

    authors: Jeon RJ,Hellen A,Matvienko A,Mandelis A,Abrams SH,Amaechi BT

    更新日期:2008-05-01 00:00:00