Waveguide evanescent field fluorescence microscopy: high contrast imaging of a domain forming mixed lipid Langmuir-Blodgett monolayer mimicking lung surfactant.

Abstract:

:Waveguide evanescent field fluorescence (WEFF) microscopy is a new development that allows the imaging of contact regions between biological cells and their substratum, as well as imaging of ultrathin films such as monomolecular Langmuir-Blodgett (LB) films. Mixed-lipid monolayer systems mimicking lung surfactant were fabricated on waveguides using the LB technique and imaged by both WEFF and standard wide field epi-fluorescence microscopy. These two technologies were compared with respect to contrast, photobleaching, and sensitivity. It was found that WEFF microscopy produced images with a much higher contrast, lower photobleaching, and higher sensitivity. In addition, fine structures in the lipidic domains were observed for the first time.

journal_name

J Biomed Opt

authors

Hassanzadeh A,Mittler S

doi

10.1117/1.3569095

subject

Has Abstract

pub_date

2011-04-01 00:00:00

pages

046022

issue

4

eissn

1083-3668

issn

1560-2281

journal_volume

16

pub_type

杂志文章
  • Tracer-cocktail injections for combined pre- and intraoperative multimodal imaging of lymph nodes in a spontaneous mouse prostate tumor model.

    abstract::To improve surgical guidance toward prostate draining lymph nodes, we investigate the potential of intraoperative fluorescence imaging and combined pre- and intraoperative multimodality imaging approaches. Transgenic adenocarcinoma mouse prostate mice with spontaneous prostate tumors are injected intratumorally with: ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3528027

    authors: van Leeuwen AC,Buckle T,Bendle G,Vermeeren L,Valdés Olmos R,van de Poel HG,van Leeuwen FW

    更新日期:2011-01-01 00:00:00

  • Resolution in the ApoTome and the confocal laser scanning microscope: comparison.

    abstract::The essential feature of the confocal laser scanning microscope (cLSM) is the generation of optical sections by the removal of out-of-focus light. About ten years ago, structured illumination microscopy (SIM) was introduced as an alternative method for obtaining optical sections from biological specimens. Here we comp...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3083439

    authors: Weigel A,Schild D,Zeug A

    更新日期:2009-01-01 00:00:00

  • Transmissive liquid-crystal device for correcting primary coma aberration and astigmatism in biospecimen in two-photon excitation laser scanning microscopy.

    abstract::All aberrations produced inside a biospecimen can degrade the quality of a three-dimensional image in two-photon excitation laser scanning microscopy. Previously, we developed a transmissive liquid-crystal device to correct spherical aberrations that improved the image quality of a fixed-mouse-brain slice treated with...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.121503

    authors: Tanabe A,Hibi T,Ipponjima S,Matsumoto K,Yokoyama M,Kurihara M,Hashimoto N,Nemoto T

    更新日期:2016-12-01 00:00:00

  • Comparative evaluation of differential laser-induced perturbation spectroscopy as a technique to discriminate emerging skin pathology.

    abstract::Fluorescence spectroscopy has been widely investigated as a technique for identifying pathological tissue; however, unrelated subject-to-subject variations in spectra complicate data analysis and interpretation. We describe and evaluate a new biosensing technique, differential laser-induced perturbation spectroscopy (...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.6.067002

    authors: Kozikowski RT,Smith SE,Lee JA,Castleman WL,Sorg BS,Hahn DW

    更新日期:2012-06-01 00:00:00

  • Blood screening using diffraction phase cytometry.

    abstract::Blood smear analysis has remained a crucial diagnostic tool for pathologists despite the advent of automatic analyzers such as flow cytometers and impedance counters. Though these current methods have proven to be indispensible tools for physicians and researchers alike, they provide limited information on the detaile...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3369965

    authors: Mir M,Ding H,Wang Z,Reedy J,Tangella K,Popescu G

    更新日期:2010-03-01 00:00:00

  • Measurement of drug and macromolecule diffusion across atherosclerotic rabbit aorta ex vivo by attenuated total reflection-Fourier transform infrared imaging.

    abstract::Diffusion of two model drugs-benzyl nicotinate and ibuprofen-and the plasma macromolecule albumin across atherosclerotic rabbit aorta was studied ex vivo by attenuated total reflection-Fourier transform infrared (ATR-FTIR) imaging. Solutions of these molecules were applied to the endothelial surface of histological se...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3174395

    authors: Palombo F,Danoux CB,Weinberg PD,Kazarian SG

    更新日期:2009-07-01 00:00:00

  • Pulse-modulated second harmonic imaging microscope quantitatively demonstrates marked increase of collagen in tumor after chemotherapy.

    abstract::Pulse-modulated second harmonic imaging microscopes (PM-SHIMs) exhibit improved signal-to-noise ratio (SNR) over conventional SHIMs on sensitive imaging and quantification of weak collagen signals inside tissues. We quantify the spatial distribution of sparse collagen inside a xenograft model of human acute myeloid le...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3497565

    authors: Raja AM,Xu S,Sun W,Zhou J,Tai DC,Chen CS,Rajapakse JC,So PT,Yu H

    更新日期:2010-09-01 00:00:00

  • Spectrally resolved fluorescence lifetime imaging to investigate cell metabolism in malignant and nonmalignant oral mucosa cells.

    abstract::Fluorescence-guided diagnosis of tumor tissue is in many cases insufficient, because false positive results interfere with the outcome. Improvement through observation of cell metabolism might offer the solution, but needs a detailed understanding of the origin of autofluorescence. With respect to this, spectrally res...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.9.096005

    authors: Rück A,Hauser C,Mosch S,Kalinina S

    更新日期:2014-09-01 00:00:00

  • Volume holographic imaging endoscopic design and construction techniques.

    abstract::A reflectance volume holographic imaging (VHI) endoscope has been designed for simultaneous in vivo imaging of surface and subsurface tissue structures. Prior utilization of VHI systems has been limited to ex vivo tissue imaging. The VHI system presented in this work is designed for laparoscopic use. It consists of a ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.5.056010

    authors: Howlett ID,Han W,Gordon M,Rice P,Barton JK,Kostuk RK

    更新日期:2017-05-01 00:00:00

  • Contact, high-resolution spatial diffuse reflectance imaging system for skin condition diagnosis.

    abstract::Spatially resolved diffuse reflectance spectroscopy (srDRS) is a well-established technique for noninvasive, in vivo characterization of tissue optical properties toward diagnostic applications. srDRS has a potential for depth-resolved analysis of tissue, which is desired in various clinical situations. However, curre...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.11.115003

    authors: Petitdidier N,Koenig A,Gerbelot R,Grateau H,Gioux S,Jallon P

    更新日期:2018-11-01 00:00:00

  • Confocal multispot microscope for fast and deep imaging in semicleared tissues.

    abstract::Although perfectly transparent specimens are imaged faster with light-sheet microscopy, less transparent samples are often imaged with two-photon microscopy leveraging its robustness to scattering; however, at the price of increased acquisition times. Clearing methods that are capable of rendering strongly scattering ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.2.020503

    authors: Adam MP,Müllenbroich MC,Di Giovanna AP,Alfieri D,Silvestri L,Sacconi L,Pavone FS

    更新日期:2018-02-01 00:00:00

  • Unsupervised analysis of small animal dynamic Cerenkov luminescence imaging.

    abstract::Clustering analysis (CA) and principal component analysis (PCA) were applied to dynamic Cerenkov luminescence images (dCLI). In order to investigate the performances of the proposed approaches, two distinct dynamic data sets obtained by injecting mice with (32)P-ATP and (18)F-FDG were acquired using the IVIS 200 optic...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3663442

    authors: Spinelli AE,Boschi F

    更新日期:2011-12-01 00:00:00

  • Propagation of coherent polarized light in turbid highly scattering medium.

    abstract::Within the framework of further development of unified Monte Carlo code for the needs of biomedical optics and biophotonics, we present an approach for modeling of coherent polarized light propagation in highly scattering turbid media, such as biological tissues. The temporal coherence of light, linear and circular po...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.2.025005

    authors: Doronin A,Macdonald C,Meglinski I

    更新日期:2014-02-01 00:00:00

  • Multispectral in vivo three-dimensional optical coherence tomography of human skin.

    abstract::The capability of optical coherence tomography (OCT) to perform "optical biopsy" of tissues within a depth range of 1 to 2 mm with micron-scale resolution in real time makes it a promising biomedical imaging modality for dermatologic applications. Three high-speed, spectrometer-based frequency-domain OCT systems opera...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3400665

    authors: Alex A,Povazay B,Hofer B,Popov S,Glittenberg C,Binder S,Drexler W

    更新日期:2010-03-01 00:00:00

  • Laser trap ionization for identification of human erythrocytes with variable hemoglobin quantitation.

    abstract::An approach to an established technique that is potentially applicable for a more comprehensive understanding of the electrical properties of red blood cells (RBCs) is presented. Using a high-intensity gradient laser trap, RBCs can be singly trapped and consequentially ionized. The subsequent dynamics of the ionized c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.5.055005

    authors: Kelley M,Cooper J,Devito D,Mushi R,Aguinaga MDP,Erenso DB

    更新日期:2018-05-01 00:00:00

  • Real-time in vivo photoacoustic and ultrasound imaging.

    abstract::A real-time photoacoustic imaging system is designed and built. This system is based on a commercially available ultrasound imaging system. It can achieve a frame rate of 8 frames/sec. Vasculature in the hand of a human volunteer is imaged, and the resulting photoacoustic image is combined with the ultrasound image. T...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3005421

    authors: Kolkman RG,Brands PJ,Steenbergen W,van Leeuwen TG

    更新日期:2008-09-01 00:00:00

  • Optical waveguides formed by silver ion exchange in Schott SG11 glass for waveguide evanescent field fluorescence microscopy: evanescent images of HEK293 cells.

    abstract::Planar glass waveguides with a specific number of modes were fabricated by Ag(+)-Na(+) exchange in Schott SG11 glass. The effective refractive indices were determined using m-line spectroscopy in both s- and p-polarization. By using the reversed Wentzel-Kramers-Brillouin approximation, the index profiles were describe...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3443796

    authors: Hassanzadeh A,Nitsche M,Armstrong S,Nabavi N,Harrison R,Dixon SJ,Langbein U,Mittler S

    更新日期:2010-05-01 00:00:00

  • In-vivo imaging of murine tumors using complete-angle projection fluorescence molecular tomography.

    abstract::We interrogate the ability of free-space fluorescence tomography to image small animals in vivo using charge-coupled device (CCD) camera measurements over 360-deg noncontact projections. We demonstrate the performance of normalized dual-wavelength measurements that are essential for in-vivo use, as they account for th...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3149854

    authors: Deliolanis NC,Dunham J,Wurdinger T,Figueiredo JL,Tannous BA,Ntziachristos V

    更新日期:2009-05-01 00:00:00

  • Quantitative fluorescence tomography using a trimodality system: in vivo validation.

    abstract::A fully integrated trimodality fluorescence, diffuse optical, and x-ray computed tomography (FT/DOT/XCT) system for small animal imaging is reported in this work. The main purpose of this system is to obtain quantitatively accurate fluorescence concentration images using a multimodality approach. XCT offers anatomical...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3467495

    authors: Lin Y,Barber WC,Iwanczyk JS,Roeck WW,Nalcioglu O,Gulsen G

    更新日期:2010-07-01 00:00:00

  • High-resolution whole organ imaging using two-photon tissue cytometry.

    abstract::Three-dimensional (3-D) tissue imaging offers substantial benefits to a wide range of biomedical investigations from cardiovascular biology, diabetes, Alzheimer's disease to cancer. Two-photon tissue cytometry is a novel technique based on high-speed multiphoton microscopy coupled with automated histological sectionin...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2435626

    authors: Ragan T,Sylvan JD,Kim KH,Huang H,Bahlmann K,Lee RT,So PT

    更新日期:2007-01-01 00:00:00

  • Mapping local optical axis in birefringent samples using polarization-sensitive optical coherence tomography.

    abstract::An algorithm was developed to obtain depth-resolved local optical axis in birefringent samples by using conventional polarization-sensitive optical coherence tomography (PSOCT) that uses a single circularly polarized incident light. The round-trip sample Jones matrices were first constructed from the cumulative PSOCT ...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.17.11.110501

    authors: Fan C,Yao G

    更新日期:2012-11-01 00:00:00

  • Computational segmentation of collagen fibers from second-harmonic generation images of breast cancer.

    abstract::Second-harmonic generation (SHG) imaging can help reveal interactions between collagen fibers and cancer cells. Quantitative analysis of SHG images of collagen fibers is challenged by the heterogeneity of collagen structures and low signal-to-noise ratio often found while imaging collagen in tissue. The role of collag...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.1.016007

    authors: Bredfeldt JS,Liu Y,Pehlke CA,Conklin MW,Szulczewski JM,Inman DR,Keely PJ,Nowak RD,Mackie TR,Eliceiri KW

    更新日期:2014-01-01 00:00:00

  • Optical power transfer and communication methods for wireless implantable sensing platforms.

    abstract::Ultrasmall scale implants have recently attracted focus as valuable tools for monitoring both acute and chronic diseases. Semiconductor optical technologies are the key to miniaturizing these devices to the long-sought sub-mm scale, which will enable long-term use of these devices for medical applications. This can al...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.9.095012

    authors: Mujeeb-U-Rahman M,Adalian D,Chang CF,Scherer A

    更新日期:2015-09-01 00:00:00

  • Light scattering of human red blood cells during metabolic remodeling of the membrane.

    abstract::We present the light scattering properties of individual human red blood cells (RBCs). We show that both the RBC static and dynamic scattering signals are altered by adenosine 5'-triphosphate (ATP)-driven membrane metabolic remodeling. To measure the light scattering signal from individual RBCs, we use diffraction pha...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3524509

    authors: Park Y,Best-Popescu CA,Dasari RR,Popescu G

    更新日期:2011-01-01 00:00:00

  • Photon migration through fetal head in utero using continuous wave, near-infrared spectroscopy: development and evaluation of experimental and numerical models.

    abstract::In this work experimental tissue phantoms and numerical models were developed to estimate photon migration through the fetal head in utero. The tissue phantoms incorporate a fetal head within an amniotic fluid sac surrounded by a maternal tissue layer. A continuous wave, dual-wavelength (lambda = 760 and 850 nm) spect...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429983

    authors: Vishnoi G,Hielscher AH,Ramanujam N,Chance B

    更新日期:2000-04-01 00:00:00

  • Infrared spectroscopic analysis of human and bovine articular cartilage proteoglycans using carbohydrate peak or its second derivative.

    abstract::Fourier transform infrared (FTIR) microspectroscopy has been used to estimate the spatial proteoglycan (PG) and collagen contents in articular cartilage (AC). However, it is not clear whether the results of FTIR analyses are consistent between different species. Our aim was to clarify how three different FTIR PG param...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.9.097006

    authors: Rieppo L,Närhi T,Helminen HJ,Jurvelin JS,Saarakkala S,Rieppo J

    更新日期:2013-09-01 00:00:00

  • Acousto-optic-tunable-filter-based spectropolarimetric imagers for medical diagnostic applications--instrument design point of view.

    abstract::Compact optical imagers that can detect both spectral and polarization signatures are required in many biomedical applications. An acousto-optic-tunable-filter (AOTF)-based imager is ideally suited to provide both agile spectral and polarization signatures. Such an imager can be readily used for real-time in vivo medi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2102507

    authors: Gupta N

    更新日期:2005-09-01 00:00:00

  • Reflectance confocal microscopy for characterization of mammary ductal structures and development of neoplasia in genetically engineered mouse models of breast cancer.

    abstract::The earliest steps of breast cancer begin with aberrations in mammary ductal structure. Techniques that enable an investigator to image in situ and then analyze the same tissue using biochemical tools facilitates identification of genetic networks and signaling pathways active in the imaged structure. Cellular confoca...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2065827

    authors: Parrish A,Halama E,Tilli MT,Freedman M,Furth PA

    更新日期:2005-09-01 00:00:00

  • Motion-compensated noncontact imaging photoplethysmography to monitor cardiorespiratory status during exercise.

    abstract::With the advance of computer and photonics technology, imaging photoplethysmography [(PPG), iPPG] can provide comfortable and comprehensive assessment over a wide range of anatomical locations. However, motion artifact is a major drawback in current iPPG systems, particularly in the context of clinical assessment. To ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3602852

    authors: Sun Y,Hu S,Azorin-Peris V,Greenwald S,Chambers J,Zhu Y

    更新日期:2011-07-01 00:00:00

  • High-speed upper-airway imaging using full-range optical coherence tomography.

    abstract::Obstruction in the upper airway can often cause reductions in breathing or gas exchange efficiency and lead to rest disorders such as sleep apnea. Imaging diagnosis of the obstruction region has been accomplished using computed tomography (CT) and magnetic resonance imaging (MRI). However CT requires the use of ionizi...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.jbo.17.11.110507

    authors: Jing J,Zhang J,Loy AC,Wong BJ,Chen Z

    更新日期:2012-11-01 00:00:00