Optical power transfer and communication methods for wireless implantable sensing platforms.

Abstract:

:Ultrasmall scale implants have recently attracted focus as valuable tools for monitoring both acute and chronic diseases. Semiconductor optical technologies are the key to miniaturizing these devices to the long-sought sub-mm scale, which will enable long-term use of these devices for medical applications. This can also enable the use of multiple implantable devices concurrently to form a true body area network of sensors. We demonstrate optical power transfer techniques and methods to effectively harness this power for implantable devices. Furthermore, we also present methods for optical data transfer from such implants. Simultaneous use of these technologies can result in miniaturized sensing platforms that can allow for large-scale use of such systems in real world applications.

journal_name

J Biomed Opt

authors

Mujeeb-U-Rahman M,Adalian D,Chang CF,Scherer A

doi

10.1117/1.JBO.20.9.095012

subject

Has Abstract

pub_date

2015-09-01 00:00:00

pages

095012

issue

9

eissn

1083-3668

issn

1560-2281

pii

2448188

journal_volume

20

pub_type

杂志文章
  • In vivo photoacoustic imaging of major blood vessels in the pancreas and liver during surgery.

    abstract::Abdominal surgeries carry considerable risk of gastrointestinal and intra-abdominal hemorrhage, which could possibly cause patient death. Photoacoustic imaging is one solution to overcome this challenge by providing visualization of major blood vessels during surgery. We investigate the feasibility of in vivo blood ve...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.12.121905

    authors: Kempski KM,Wiacek A,Graham M,González E,Goodson B,Allman D,Palmer J,Hou H,Beck S,He J,Bell MAL

    更新日期:2019-08-01 00:00:00

  • Robust single-molecule approach for counting autofluorescent proteins.

    abstract::Using single-molecule microscopy, we present a method to quantify the number of single autofluorescent proteins when they cannot be optically resolved. This method relies on the measurement of the total intensity emitted by each aggregate until it photobleaches. This strategy overcomes the inherent problem of blinking...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2940600

    authors: Cognet L,Tardin C,Négrier ML,Breillat C,Coussen F,Choquet D,Lounis B

    更新日期:2008-05-01 00:00:00

  • In vitro detection and quantification of enamel and root caries using infrared photothermal radiometry and modulated luminescence.

    abstract::Artificially created demineralized and remineralized carious lesions on the root and enamel of human teeth were examined by photothermal radiometry (PTR) and modulated luminescence (LUM). Fourteen extracted human teeth were used and a lesion was created on a 1 mmx4 mm rectangular window, spanning root to enamel, using...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2942374

    authors: Jeon RJ,Hellen A,Matvienko A,Mandelis A,Abrams SH,Amaechi BT

    更新日期:2008-05-01 00:00:00

  • Robot-assisted three-dimensional registration for cochlear implant surgery using a common-path swept-source optical coherence tomography probe.

    abstract::Cochlear implantation offers the potential to restore sensitive hearing in patients with severe to profound deafness. However, surgical placement of the electrode array within the cochlea can produce trauma to sensorineural components, particularly if the initial turn of the cochlea is not successfully navigated as th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.5.057004

    authors: Gurbani SS,Wilkening P,Zhao M,Gonenc B,Cheon GW,Iordachita II,Chien W,Taylor RH,Niparko JK,Kang JU

    更新日期:2014-05-01 00:00:00

  • Understanding three-dimensional spatial relationship between the mouse second polar body and first cleavage plane with full-field optical coherence tomography.

    abstract::The morphogenetic relationship between early patterning and polarity formation is of fundamental interest and remains a controversial issue in preimplantation embryonic development. We use a label-free three-dimensional (3-D) imaging technique of full-field optical coherence tomography (FF-OCT) successfully for the fi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.1.010503

    authors: Zheng JG,Huo T,Chen T,Wang C,Zhang N,Tian N,Zhao F,Lu D,Chen D,Ma W,Sun JL,Xue P

    更新日期:2013-01-01 00:00:00

  • Retinal response of Macaca mulatta to picosecond laser pulses of varying energy and spot size.

    abstract::We investigate the relationship between the laser beam at the retina (spot size) and the extent of retinal injury from single ultrashort laser pulses. From previous studies it is believed that the retinal effect of single 3-ps laser pulses should vary in extent and location, depending on the occurrence of laser-induce...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1805554

    authors: Roach WP,Cain CP,Narayan DG,Noojin GD,Boppart SA,Birngruber R,Fujimoto JG,Toth CA

    更新日期:2004-11-01 00:00:00

  • Confocal reflectance and two-photon microscopy studies of a songbird skull for preparation of transcranial imaging.

    abstract::We present experiments and analyses of confocal reflectance and two-photon microscopy studies of zebra finch skull samples. The thin and hollow structure of these birds' skulls is quite translucent, which can allow in vivo transcranial two-photon imaging for brain activation monitoring. However, the skull structure is...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3155522

    authors: Abi-Haidar D,Olivier T

    更新日期:2009-05-01 00:00:00

  • Correlation of functional and resting state connectivity of cerebral oxy-, deoxy-, and total hemoglobin concentration changes measured by near-infrared spectrophotometry.

    abstract::The aim is to study cerebral vascular functional connectivity during motor tasks and resting state using multichannel frequency-domain near-infrared spectrophotometry. Maps of 5.7 × 10.8 cm size displaying changes in cerebral oxyhemoglobin (O(2)Hb), deoxyhemoglobin (HHb), and total hemoglobin (tHb) concentrations were...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3615249

    authors: Wolf U,Toronov V,Choi JH,Gupta R,Michalos A,Gratton E,Wolf M

    更新日期:2011-08-01 00:00:00

  • Chemical reactivation of fluorescein isothiocyanate immunofluorescence-labeled resin-embedded samples.

    abstract::Resin embedding is widely used and facilitates microscopic imaging of biological tissues. In contrast, quenching of fluorescence during embedding process hinders the application of resin embedding for imaging of fluorescence-labeled samples. For samples expressing fluorescent proteins, it has been demonstrated that th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.2.020501

    authors: Li L,Rao G,Lv X,Chen R,Cheng X,Wang X,Zeng S,Liu X

    更新日期:2018-02-01 00:00:00

  • Photonic approach to the selective inactivation of viruses with a near-infrared subpicosecond fiber laser.

    abstract::We report a photonic approach for selective inactivation of viruses with a near-infrared subpicosecond laser. We demonstrate that this method can selectively inactivate viral particles ranging from nonpathogenic viruses such as the M13 bacteriophage and the tobacco mosaic virus to pathogenic viruses such as the human ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3275477

    authors: Tsen KT,Tsen SW,Fu Q,Lindsay SM,Kibler K,Jacobs B,Wu TC,Karanam B,Jagu S,Roden RB,Hung CF,Sankey OF,Ramakrishna B,Kiang JG

    更新日期:2009-11-01 00:00:00

  • Near-infrared light-responsive liposomal contrast agent for photoacoustic imaging and drug release applications.

    abstract::Photoacoustic imaging has become an emerging tool for theranostic applications. Not only does it help in

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.4.041007

    authors: Sivasubramanian K,Mathiyazhakan M,Wiraja C,Upputuri PK,Xu C,Pramanik M

    更新日期:2017-04-01 00:00:00

  • Time-resolved imaging of optical coefficients through murine chest cavities.

    abstract::As small animal optical imaging and tomography are gaining popularity for interrogating functional and molecular events in vivo, it becomes increasingly necessary to gain knowledge of the optical properties of the species investigated to better understand and describe photon propagation through their tissues. To achie...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2400702

    authors: Niedre MJ,Turner GM,Ntziachristos V

    更新日期:2006-11-01 00:00:00

  • Analysis of the dispersion compensation of acousto-optic deflectors used for multiphoton imaging.

    abstract::The acousto-optic deflector (AOD) is highly preferred in laser scanning microscopy for its fast scanning ability and random-addressing capability. However, its application in two-photon microscopy is frustrated by the dispersion of the AOD, which results in beam distortion and pulse lengthening. We report the analysis...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714061

    authors: Zeng S,Lv X,Bi K,Zhan C,Li D,Chen WR,Xiong W,Jacques SL,Luo Q

    更新日期:2007-03-01 00:00:00

  • Minimizing Thermal Damage in Corneal Ablation with Short Pulse Mid-infrared Lasers.

    abstract::Photospallation is proposed as the primary mechanism behind our recent animal studies involving corneal ablation by nanosecond-pulse mid-IR laser beams. Following a brief summary of earlier work directed to refractive procedures in the mid-IR, a preliminary analysis is presented, based on simple one-dimensional models...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429958

    authors: Hoffman HJ,Telfair WB

    更新日期:1999-10-01 00:00:00

  • Dynamic performance of microelectromechanical systems deformable mirrors for use in an active/adaptive two-photon microscope.

    abstract::Active optics such as deformable mirrors can be used to control both focal depth and aberrations during scanning laser microscopy. If the focal depth can be changed dynamically during scanning, then imaging of oblique surfaces becomes possible. If aberrations can be corrected dynamically during scanning, an image can ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.121507

    authors: Archer-Zhang CC,Foster WB,Downey RD,Arrasmith CL,Dickensheets DL

    更新日期:2016-12-01 00:00:00

  • Diagnostic performance of receptor-specific surgical specimen staining correlates with receptor expression level.

    abstract::Intraoperative margin assessment is imperative to cancer cure but is a continued challenge to successful surgery. Breast conserving surgery is a relevant example, where a cosmetically improved outcome is gained over mastectomy, but re-excision is required in >25  %   of cases due to positive or closely involved margin...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.2.026002

    authors: Schaefer JM,Barth CW,Davis SC,Gibbs SL

    更新日期:2019-02-01 00:00:00

  • Oblique incidence reflectometry: optical models and measurements using a side-viewing gradient index lens-based endoscopic imaging system.

    abstract::A side-viewing, 2.3-mm diameter oblique incidence reflectometry endoscope has been designed to obtain optical property measurements of turbid samples. Light from a single-mode fiber is relayed obliquely onto the tissue with a gradient index lens-based distal optics assembly and the resulting diffuse reflectance profil...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.6.067002

    authors: Wall RA,Barton JK

    更新日期:2014-06-01 00:00:00

  • Adaptive wide-field optical tomography.

    abstract::We describe a wide-field optical tomography technique, which allows the measurement-guided optimization of illumination patterns for enhanced reconstruction performances. The iterative optimization of the excitation pattern aims at reducing the dynamic range in photons transmitted through biological tissue. It increas...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.036006

    authors: Venugopal V,Intes X

    更新日期:2013-03-01 00:00:00

  • Filter-based method for background removal in high-sensitivity wide-field-surface-enhanced Raman scattering imaging in vivo.

    abstract::As molecular imaging moves towards lower detection limits, the elimination of endogenous background signals becomes imperative. We present a facile background-suppression technique that specifically segregates the signal from surface-enhanced Raman scattering (SERS)-active nanoparticles (NPs) from the tissue autofluor...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.076017

    authors: Mallia RJ,McVeigh PZ,Veilleux I,Wilson BC

    更新日期:2012-07-01 00:00:00

  • In vivo wide-field multispectral scanning laser ophthalmoscopy-optical coherence tomography mouse retinal imager: longitudinal imaging of ganglion cells, microglia, and Müller glia, and mapping of the mouse retinal and choroidal vasculature.

    abstract::Scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT) provide complementary views of the retina, with the former collecting fluorescence data with good lateral but relatively low-axial resolution, and the latter collecting label-free backscattering data with comparable lateral but much higher axia...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.12.126005

    authors: Zhang P,Zam A,Jian Y,Wang X,Li Y,Lam KS,Burns ME,Sarunic MV,Pugh EN Jr,Zawadzki RJ

    更新日期:2015-01-01 00:00:00

  • Laser trap ionization for identification of human erythrocytes with variable hemoglobin quantitation.

    abstract::An approach to an established technique that is potentially applicable for a more comprehensive understanding of the electrical properties of red blood cells (RBCs) is presented. Using a high-intensity gradient laser trap, RBCs can be singly trapped and consequentially ionized. The subsequent dynamics of the ionized c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.5.055005

    authors: Kelley M,Cooper J,Devito D,Mushi R,Aguinaga MDP,Erenso DB

    更新日期:2018-05-01 00:00:00

  • Sensitivity map of laser tweezers Raman spectroscopy for single-cell analysis of colorectal cancer.

    abstract::Raman spectroscopy on single, living epithelial cells captured in a laser trap is shown to have diagnostic power over colorectal cancer. This new single-cell technology comprises three major components: primary culture processing of human tissue samples to produce single-cell suspensions, Raman detection on singly tra...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2748060

    authors: Zheng F,Qin Y,Chen K

    更新日期:2007-05-01 00:00:00

  • Design of synchrotron light source and its beamline dedicated to dual-energy x-ray computed tomography.

    abstract::A synchrotron light source dedicated to medical applications has been designed at National Institute of Radiological Sciences. The storage ring, with circumference of 80 m, is designed for acceleration of 2.3 GeV and a stored current of 420 mA. It is equipped with two multipole wigglers to produce sufficient photon fl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1383062

    authors: Torikoshi M,Tsunoo T,Endo M,Noda K,Kumada M,Yamada S,Soga F,Hyodo K

    更新日期:2001-07-01 00:00:00

  • Time-reversed ultrasonically encoded optical focusing using two ultrasonic transducers for improved ultrasonic axial resolution.

    abstract::Focusing light inside highly scattering media is a challenging task in biomedical optical imaging, manipulation, and therapy. A recent invention has overcome this challenge by time reversing ultrasonically encoded diffuse light to an ultrasound-modulated volume inside a turbid medium. In this technique, a photorefract...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.11.110502

    authors: Yang Q,Xu X,Lai P,Xu D,Wang LV

    更新日期:2013-11-01 00:00:00

  • Temperature-controlled in vivo ocular exposure to 1090-nm radiation suggests that near-infrared radiation cataract is thermally induced.

    abstract::The damage mechanism for near-infrared radiation (IRR) induced cataract is unclear. Both a photochemical and a thermal mechanism were suggested. The current paper aims to elucidate a photochemical effect based on investigation of irradiance-exposure time reciprocity. Groups of 20 rats were unilaterally exposed to 96-W...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.1.015003

    authors: Yu Z,Schulmeister K,Talebizadeh N,Kronschläger M,Söderberg P

    更新日期:2015-01-01 00:00:00

  • Investigation of the cerebral hemodynamic response function in single blood vessels by functional photoacoustic microscopy.

    abstract::The specificity of the hemodynamic response function (HRF) is determined spatially by the vascular architecture and temporally by the evolution of hemodynamic changes. Here, we used functional photoacoustic microscopy (fPAM) to investigate single cerebral blood vessels of rats after left forepaw stimulation. In this s...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.6.061210

    authors: Liao LD,Lin CT,Shih YY,Lai HY,Zhao WT,Duong TQ,Chang JY,Chen YY,Li ML

    更新日期:2012-06-01 00:00:00

  • In-vivo Fourier domain optical coherence tomography as a new tool for investigation of vasodynamics in the mouse model.

    abstract::In-vivo imaging of the vascular system can provide novel insight into the dynamics of vasoconstriction and vasodilation. Fourier domain optical coherence tomography (FD-OCT) is an optical, noncontact imaging technique based on interferometry of short-coherent near-infrared light with axial resolution of less than 10 m...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3149865

    authors: Meissner S,Müller G,Walther J,Morawietz H,Koch E

    更新日期:2009-05-01 00:00:00

  • Functional imaging of dye concentration in tissue phantoms by spectroscopic optical coherence tomography.

    abstract::We present functional imaging of the concentration of a photodynamic therapy (PDT)-related dye in scattering tissue phantoms based on spatially resolved measurements of optical properties through spectroscopic optical coherence tomography (OCT). Expressions for the OCT signal are developed, enabling estimation of dept...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1898242

    authors: Støren T,Røyset A,Svaasand LO,Lindmo T

    更新日期:2005-03-01 00:00:00

  • Contact, high-resolution spatial diffuse reflectance imaging system for skin condition diagnosis.

    abstract::Spatially resolved diffuse reflectance spectroscopy (srDRS) is a well-established technique for noninvasive, in vivo characterization of tissue optical properties toward diagnostic applications. srDRS has a potential for depth-resolved analysis of tissue, which is desired in various clinical situations. However, curre...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.11.115003

    authors: Petitdidier N,Koenig A,Gerbelot R,Grateau H,Gioux S,Jallon P

    更新日期:2018-11-01 00:00:00

  • Innovative Troxler-free measurement of macular pigment and lens density with correction of the former for the aging lens.

    abstract::Simplified measurement of macular pigment optical density (MPOD) is important because of the ocular health benefits that are attributed to these retinal carotenoids. Here, we describe a novel instrument designed for this purpose, based on heterochromatic flicker photometry (HFP), which removes a number of difficulties...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.10.107003

    authors: Bone RA,Mukherjee A

    更新日期:2013-10-01 00:00:00