Temperature-controlled in vivo ocular exposure to 1090-nm radiation suggests that near-infrared radiation cataract is thermally induced.

Abstract:

:The damage mechanism for near-infrared radiation (IRR) induced cataract is unclear. Both a photochemical and a thermal mechanism were suggested. The current paper aims to elucidate a photochemical effect based on investigation of irradiance-exposure time reciprocity. Groups of 20 rats were unilaterally exposed to 96-W/cm(2) IRR at 1090 nm within the dilated pupil accumulating 57, 103, 198, and 344 kJ/cm(2), respectively. Temperature was recorded at the limbus of the exposed eye. Seven days after exposure, the lenses were macroscopically imaged and light scattering was quantitatively measured. The average maximum temperature increases for exposure times of 10, 18, 33, and 60 min were expressed as 7.0 ± 1.1, 6.8 ± 1.1, 7.6 ± 1.3, and 7.4 ± 1.1 °C [CI (0.95)] at the limbus of the exposed eye. The difference of light scattering in the lenses between exposed and contralateral not-exposed eyes was 0.00 ± 0.02, 0.01 ± 0.03, -0.01 ± 0.02, and -0.01 ± 0.03 transformed equivalent diazepam concentration (tEDC), respectively, and no apparent morphological changes in the lens were observed. An exposure to 96-W/cm(2) 1090-nm IRR projected on the cornea within the dilated pupil accumulating radiant exposures up to 344 kJ/cm(2) does not induce cataract if the temperature rise at the limbus is <8 °C. This is consistent with a thermal damage mechanism for IRR-induced cataract.

journal_name

J Biomed Opt

authors

Yu Z,Schulmeister K,Talebizadeh N,Kronschläger M,Söderberg P

doi

10.1117/1.JBO.20.1.015003

subject

Has Abstract

pub_date

2015-01-01 00:00:00

pages

015003

issue

1

eissn

1083-3668

issn

1560-2281

pii

2092207

journal_volume

20

pub_type

杂志文章
  • Shining Future of Biomedical Optics

    abstract::Lihong V. Wang summarizes his tenure as Editor-in-Chief of the Journal of Biomedical Optics and introduces his successor, Brian Pogue, who will assume the role in January 2018. ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.10.100101

    authors: Wang V

    更新日期:2017-10-04 00:00:00

  • Biochemical analysis of human breast tissues using Fourier-transform Raman spectroscopy.

    abstract::We employ Fourier-transform Raman spectroscopy to study normal and tumoral human breast tissues, including several subtypes of cancers. We analyzed 194 Raman spectra from breast tissues that were separated into 9 groups according to their corresponding histopathological diagnosis. The assignment of the relevant Raman ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2363362

    authors: Bitar RA,Martinho Hda S,Tierra-Criollo CJ,Zambelli Ramalho LN,Netto MM,Martin AA

    更新日期:2006-09-01 00:00:00

  • Near infrared fluorescent optical imaging for nodal staging.

    abstract::Current techniques to assess lymph node metastases in cancer patients include lymphoscintigraphy after administration of a nonspecific radiocolloid in order to locate and resect lymph nodes for pathological examination of harbored cancer cells. Clinical trials involving intradermal or subcutaneous injection of antibod...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.2953498

    authors: Sampath L,Wang W,Sevick-Muraca EM

    更新日期:2008-07-01 00:00:00

  • Adaptive wide-field optical tomography.

    abstract::We describe a wide-field optical tomography technique, which allows the measurement-guided optimization of illumination patterns for enhanced reconstruction performances. The iterative optimization of the excitation pattern aims at reducing the dynamic range in photons transmitted through biological tissue. It increas...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.036006

    authors: Venugopal V,Intes X

    更新日期:2013-03-01 00:00:00

  • Blood screening using diffraction phase cytometry.

    abstract::Blood smear analysis has remained a crucial diagnostic tool for pathologists despite the advent of automatic analyzers such as flow cytometers and impedance counters. Though these current methods have proven to be indispensible tools for physicians and researchers alike, they provide limited information on the detaile...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3369965

    authors: Mir M,Ding H,Wang Z,Reedy J,Tangella K,Popescu G

    更新日期:2010-03-01 00:00:00

  • Acousto-optic-tunable-filter-based spectropolarimetric imagers for medical diagnostic applications--instrument design point of view.

    abstract::Compact optical imagers that can detect both spectral and polarization signatures are required in many biomedical applications. An acousto-optic-tunable-filter (AOTF)-based imager is ideally suited to provide both agile spectral and polarization signatures. Such an imager can be readily used for real-time in vivo medi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2102507

    authors: Gupta N

    更新日期:2005-09-01 00:00:00

  • Light scattering of human red blood cells during metabolic remodeling of the membrane.

    abstract::We present the light scattering properties of individual human red blood cells (RBCs). We show that both the RBC static and dynamic scattering signals are altered by adenosine 5'-triphosphate (ATP)-driven membrane metabolic remodeling. To measure the light scattering signal from individual RBCs, we use diffraction pha...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3524509

    authors: Park Y,Best-Popescu CA,Dasari RR,Popescu G

    更新日期:2011-01-01 00:00:00

  • Change of tumor vascular reactivity during tumor growth and postchemotherapy observed by near-infrared spectroscopy.

    abstract::Breast cancer is one of the most common cancers in females. To monitor chemotherapeutic efficacy for breast cancer, medical imaging systems such as x-ray mammography, computed tomography, magnetic resonance imaging, and ultrasound imaging have been used. Currently, it can take up to 3 to 6 weeks to see the tumor respo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.12.121603

    authors: Lee S,Jeong H,Seong M,Kim JG

    更新日期:2017-12-01 00:00:00

  • Photoacoustic needle: minimally invasive guidance to biopsy.

    abstract::We introduce a needle probe based on photoacoustics (PA) to extend the scope of optical needle methods in guiding biopsies. Pulsed light is coupled to an optical fiber in a needle to be inserted in tissue, and PA signals are detected using an ultrasound imager used for needle guidance. This PA needle samples large vol...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.7.070502

    authors: Piras D,Grijsen C,Schütte P,Steenbergen W,Manohar S

    更新日期:2013-07-01 00:00:00

  • Fast and automatic imaging of immunoenzyme-stained neuronal circuits in the whole brain of Drosophila.

    abstract::Knowledge of neuronal wiring and morphogenesis in Drosophila is essential to understand brain function and dysfunction. The immunoenzyme method based on horseradish peroxidase/diaminobenzidine (HRP/DAB) provides high-contrast images to resolve details underlying neuronal architecture. However, the poor staining penetr...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.19.9.090506

    authors: Tian Q,Yuan J,Li Y,Jiang T,Gong H,Zhou W

    更新日期:2014-09-01 00:00:00

  • In vivo assessment and evaluation of lung tissue morphologic and physiological changes from non-contact endoscopic reflectance spectroscopy for improving lung cancer detection.

    abstract::We present a method for lung cancer detection exploiting reflectance spectra measured in vivo during endoscopic imaging of the lung. The measured reflectance spectra were analyzed using a specially developed light-transport model to obtain quantitative information about cancer-related, physiological, and morphologic c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2337529

    authors: Fawzy YS,Petek M,Tercelj M,Zeng H

    更新日期:2006-07-01 00:00:00

  • Quantum cascade laser-based hyperspectral imaging of biological tissue.

    abstract::The spectroscopy of analyte-specific molecular vibrations in tissue thin sections has opened up a path toward histopathology without the need for tissue staining. However, biomedical vibrational imaging has not yet advanced from academic research to routine histopathology due to long acquisition times for the microsco...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.111607

    authors: Kröger N,Egl A,Engel M,Gretz N,Haase K,Herpich I,Kränzlin B,Neudecker S,Pucci A,Schönhals A,Vogt J,Petrich W

    更新日期:2014-01-01 00:00:00

  • Bioluminescence measurements in mice using a skin window.

    abstract::Studies of bioluminescence in living animals, such as cell-based biosensor applications, require measurement of light at different wavelengths, but accurate light measurement is impeded by absorption by tissues at wavelengths<600 nm. We present a novel approach to this problem--the use of a plastic window in the skin/...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2795567

    authors: Huang Q,Acha V,Yow R,Schneider E,Sardar DK,Hornsby PJ

    更新日期:2007-09-01 00:00:00

  • Measuring contraction propagation and localizing pacemaker cells using high speed video microscopy.

    abstract::Previous studies have shown the ability of many lymphatic vessels to contract phasically to pump lymph. Every lymphangion can act like a heart with pacemaker sites that initiate the phasic contractions. The contractile wave propagates along the vessel to synchronize the contraction. However, determining the location o...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3544512

    authors: Akl TJ,Nepiyushchikh ZV,Gashev AA,Zawieja DC,Cot GL

    更新日期:2011-02-01 00:00:00

  • Image analysis methods for diffuse optical tomography.

    abstract::Three major analytical tools in imaging science are summarized and demonstrated relative to optical imaging in vivo. Standard resolution testing is optimal when infinite contrast is used and hardware evaluation is the goal. However, deep tissue imaging of absorption or fluorescent contrast agents in vivo often present...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.2209908

    authors: Pogue BW,Davis SC,Song X,Brooksby BA,Dehghani H,Paulsen KD

    更新日期:2006-05-01 00:00:00

  • Real-time in vivo photoacoustic and ultrasound imaging.

    abstract::A real-time photoacoustic imaging system is designed and built. This system is based on a commercially available ultrasound imaging system. It can achieve a frame rate of 8 frames/sec. Vasculature in the hand of a human volunteer is imaged, and the resulting photoacoustic image is combined with the ultrasound image. T...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3005421

    authors: Kolkman RG,Brands PJ,Steenbergen W,van Leeuwen TG

    更新日期:2008-09-01 00:00:00

  • Quantitative fluorescence tomography using a trimodality system: in vivo validation.

    abstract::A fully integrated trimodality fluorescence, diffuse optical, and x-ray computed tomography (FT/DOT/XCT) system for small animal imaging is reported in this work. The main purpose of this system is to obtain quantitatively accurate fluorescence concentration images using a multimodality approach. XCT offers anatomical...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3467495

    authors: Lin Y,Barber WC,Iwanczyk JS,Roeck WW,Nalcioglu O,Gulsen G

    更新日期:2010-07-01 00:00:00

  • Evaluating the use of optical coherence tomography for the detection of epithelial cancers in vitro.

    abstract::Optical coherence tomography (OCT) is a noninvasive imaging methodology that is able to image tissue to depths of over 1 mm. Many epithelial conditions, such as melanoma and oral cancers, require an invasive biopsy for diagnosis. A noninvasive, real-time, point of care method of imaging depth-resolved epithelial struc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3652708

    authors: Smith LE,Hearnden V,Lu Z,Smallwood R,Hunter KD,Matcher SJ,Thornhill MH,Murdoch C,MacNeil S

    更新日期:2011-11-01 00:00:00

  • In vivo photoacoustic imaging of blood vessels using a homodyne interferometer with zero-crossing triggering.

    abstract::We demonstrate a quasinoncontact photoacoustic imaging method using a homodyne interferometer with a long coherence length laser. The generated photoacoustic signal is detected by a system that is locked at its maximum sensitivity through the use of balanced detection and zero-crossing triggering. The balanced detecto...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.3.036002

    authors: Lu J,Gao Y,Ma Z,Zhou H,Wang RK,Wang Y

    更新日期:2017-03-01 00:00:00

  • Quantitative imaging of protein-protein interactions by multiphoton fluorescence lifetime imaging microscopy using a streak camera.

    abstract::Fluorescence lifetime imaging microscopy (FLIM) using multiphoton excitation techniques is now finding an important place in quantitative imaging of protein-protein interactions and intracellular physiology. Recent developments in multiphoton FLIM methods are reviewed and a novel multiphoton FLIM system using a streak...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1577574

    authors: Krishnan RV,Masuda A,Centonze VE,Herman B

    更新日期:2003-07-01 00:00:00

  • Pulsed photoacoustic flow imaging with a handheld system.

    abstract::Flow imaging is an important technique in a range of disease areas, but estimating low flow speeds, especially near the walls of blood vessels, remains challenging. Pulsed photoacoustic flow imaging can be an alternative since there is little signal contamination from background tissue with photoacoustic imaging. We p...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.2.026004

    authors: van den Berg PJ,Daoudi K,Steenbergen W

    更新日期:2016-02-01 00:00:00

  • Early detection of colorectal cancer relapse by infrared spectroscopy in "normal" anastomosis tissue.

    abstract::Colorectal cancer is one of the most aggressive cancers usually occurring in people above the age of 50 years. In the United States, colorectal cancer is the third most diagnosed cancer. The American Cancer Society has estimated 96,830 new cases of colon cancer and 40,000 new cases of rectal cancer in 2014 in the Unit...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.7.075007

    authors: Salman A,Sebbag G,Argov S,Mordechai S,Sahu RK

    更新日期:2015-07-01 00:00:00

  • Rapid confocal imaging of large areas of excised tissue with strip mosaicing.

    abstract::Imaging large areas of tissue rapidly and with high resolution may enable rapid pathology at the bedside. The limited field of view of high-resolution microscopes requires the merging of multiple images that are taken sequentially to cover a large area. This merging or mosaicing of images requires long acquisition and...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3582335

    authors: Abeytunge S,Li Y,Larson B,Toledo-Crow R,Rajadhyaksha M

    更新日期:2011-05-01 00:00:00

  • Voxel-based measurement sensitivity of spatially resolved near-infrared spectroscopy in layered tissues.

    abstract::We quantitatively investigated the measurement sensitivity of spatially resolved spectroscopy (SRS) across six tissue models: cerebral tissue, a small animal brain, the forehead of a fetus, an adult brain, forearm muscle, and thigh muscle. The optical path length in the voxel of the model was analyzed using Monte Carl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.3.030503

    authors: Niwayama M

    更新日期:2018-03-01 00:00:00

  • Logarithmic intensity compression in fluorescence guided surgery applications.

    abstract::The use of fluorescence video imaging to guide surgery is rapidly expanding, and improvements in camera readout dynamic range have not matched display capabilities. Logarithmic intensity compression is a fast, single-step mapping technique that can map the useable dynamic range of high-bit fluorescence images onto the...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.8.080504

    authors: DSouza AV,Lin H,Gunn J,Pogue BW

    更新日期:2015-08-01 00:00:00

  • Extending Förster resonance energy transfer measurements beyond 100 Å using common organic fluorophores: enhanced transfer in the presence of multiple acceptors.

    abstract::Using commercially available organic fluorophores, the current applications of Förster (fluorescence) resonance energy transfer (FRET) are limited to about 80 Å. However, many essential activities in cells are spatially and/or temporally dependent on the assembly/disassembly of transient complexes consisting of large-...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.1.011006

    authors: Maliwal BP,Raut S,Fudala R,D'Auria S,Marzullo VM,Luini A,Gryczynski I,Gryczynski Z

    更新日期:2012-01-01 00:00:00

  • Evaluation of the contribution of the renal capsule and cortex to kidney autofluorescence intensity under ultraviolet excitation.

    abstract::The use of reduced nicotinamide adenine dinucleotide (NADH) fluorescence to gain metabolic information on kidneys in response to an alteration in oxygen availability has previously been experimentally demonstrated, but signal quantification has not, to date, been addressed. In this work the relative contribution to ra...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3094948

    authors: Raman RN,Pivetti CD,Rubenchik AM,Matthews DL,Troppmann C,Demos SG

    更新日期:2009-03-01 00:00:00

  • Performance of a lookup table-based approach for measuring tissue optical properties with diffuse optical spectroscopy.

    abstract::Diffuse optical spectroscopy (DOS) provides a powerful tool for fast and noninvasive disease diagnosis. The ability to leverage DOS to accurately quantify tissue optical parameters hinges on the model used to estimate light-tissue interaction. We describe the accuracy of a lookup table (LUT)-based inverse model for me...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.5.057001

    authors: Nichols BS,Rajaram N,Tunnell JW

    更新日期:2012-05-01 00:00:00

  • Real-time intraoperative fluorescence imaging system using light-absorption correction.

    abstract::We present a novel fluorescence imaging system developed for real-time interventional imaging applications. The system implements a correction scheme that improves the accuracy of epi-illumination fluorescence images for light intensity variation in tissues. The implementation is based on the use of three cameras oper...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3259362

    authors: Themelis G,Yoo JS,Soh KS,Schulz R,Ntziachristos V

    更新日期:2009-11-01 00:00:00

  • Study of cadmium-induced cytotoxicity using two-photon excitation endogenous fluorescence microscopy.

    abstract::We demonstrate that using time-resolved two-photon excitation endogenous fluorescence microscopy, the cadmium (Cd)-induced cellular toxic level can be assessed by the free-to protein-bound reduced nicotinamide adenine dinucleotide (free/bound NADH) ratio in a living cell. NADH fluorescence excited at 730 nm is capture...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3250293

    authors: Li D,Yang MS,Lin T,Zheng W,Qu JY

    更新日期:2009-09-01 00:00:00