Abstract:
:We quantitatively investigated the measurement sensitivity of spatially resolved spectroscopy (SRS) across six tissue models: cerebral tissue, a small animal brain, the forehead of a fetus, an adult brain, forearm muscle, and thigh muscle. The optical path length in the voxel of the model was analyzed using Monte Carlo simulations. It was found that the measurement sensitivity can be represented as the product of the change in the absorption coefficient and the difference in optical path length in two states with different source-detector distances. The results clarified the sensitivity ratio between the surface layer and the deep layer at each source-detector distance for each model and identified changes in the deep measurement area when one of the detectors was close to the light source. A comparison was made with the results from continuous-wave spectroscopy. The study also identified measurement challenges that arise when the surface layer is inhomogeneous. Findings on the measurement sensitivity of SRS at each voxel and in each layer can support the correct interpretation of measured values when near-infrared oximetry or functional near-infrared spectroscopy is used to investigate different tissue structures.
journal_name
J Biomed Optjournal_title
Journal of biomedical opticsauthors
Niwayama Mdoi
10.1117/1.JBO.23.3.030503subject
Has Abstractpub_date
2018-03-01 00:00:00pages
1-4issue
3eissn
1083-3668issn
1560-2281pii
JBO-170729LRjournal_volume
23pub_type
杂志文章abstract::Early detection of tissue hypoxia in the intensive care unit is essential for effective treatment. Reduced nicotinamide adenine dinucleotide (NADH) has been suggested to be the most sensitive indicator of tissue oxygenation at the mitochondrial level. However, no experimental evidence comparing the kinetics of changes...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.19.1.017005
更新日期:2014-01-01 00:00:00
abstract::Lihong V. Wang summarizes his tenure as Editor-in-Chief of the Journal of Biomedical Optics and introduces his successor, Brian Pogue, who will assume the role in January 2018. ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.22.10.100101
更新日期:2017-10-04 00:00:00
abstract::Surgical excision of the whole prostate through a radical prostatectomy procedure is part of the standard of care for prostate cancer. Positive surgical margins (cancer cells having spread into surrounding nonresected tissue) occur in as many as 1 in 5 cases and strongly correlate with disease recurrence and the requi...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.24.2.025001
更新日期:2019-02-01 00:00:00
abstract::The fibrillar collagen network in tumor and normal tissues is different due to remodeling of the extracellular matrix during the malignant process. Collagen type I fibers have the crystalline and noncentrosymmetric properties required for generating the second-harmonic signal. The content and structure of collagen wer...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2983664
更新日期:2008-09-01 00:00:00
abstract::So far, the study of the optical clearing is almost always about healthy tissue. However, the ultimate goal is to detect diseases for clinical application. Optical clearing on diseased skins is explored. The effect is evaluated by applying a combined liquid paraffin and glycerol mixed solution on several kinds of dise...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.17.11.115003
更新日期:2012-11-01 00:00:00
abstract::Stenosis and occlusion of the superficial femoral artery (SFA) are most common in arterial occlusive disease. There are numerous interventional, surgical, and combined approaches to reconstitute maximum blood supply to the lower limb; however, despite intense clinical research, the long-term success rates are still po...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.2.025005
更新日期:2015-02-01 00:00:00
abstract::Doppler optical coherence tomography (DOCT) provides a novel method to measure blood flow velocity in vessels with diameter at micrometer scale. In this study, a developed spectral domain DOCT system is applied to monitor cerebral blood flow velocity changes in a rat. An animal model with a cranial window is used, and...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3560286
更新日期:2011-04-01 00:00:00
abstract::In this work experimental tissue phantoms and numerical models were developed to estimate photon migration through the fetal head in utero. The tissue phantoms incorporate a fetal head within an amniotic fluid sac surrounded by a maternal tissue layer. A continuous wave, dual-wavelength (lambda = 760 and 850 nm) spect...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.429983
更新日期:2000-04-01 00:00:00
abstract::Mueller polarimetry is applied to study the samples of nails: natural (or reference) and irradiated to 2 Gy ionizing radiation dose. We measure the whole Mueller matrices of the samples as a function of the scattering angle at a wavelength of 632.8 nm. We apply depolarization analysis to measured Mueller matrices by c...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.7.071108
更新日期:2016-07-01 00:00:00
abstract::During emergency medical situations, where the patient has an obstructed airway or necessitates respiratory support, endotracheal intubation (ETI) is the medical technique of placing a tube into the trachea in order to facilitate adequate ventilation of the lungs. Complications during ETI, such as repeated attempts, f...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.11.117004
更新日期:2016-11-01 00:00:00
abstract::Environmental metastability of zirconia (ZrO2) ceramic in the human body [represented by a tetragonal-to-monoclinic (t→m) phase transformation] takes place on the surface of the artificial joint and proceeds with time toward its interior. Its quantitative characterization is mandatory for the safety of joint implants ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.12.127002
更新日期:2013-12-01 00:00:00
abstract::We present experiments and analyses of confocal reflectance and two-photon microscopy studies of zebra finch skull samples. The thin and hollow structure of these birds' skulls is quite translucent, which can allow in vivo transcranial two-photon imaging for brain activation monitoring. However, the skull structure is...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3155522
更新日期:2009-05-01 00:00:00
abstract::We explore the use of Monte-Carlo-model-based approaches for the analysis of fluorescence and diffuse reflectance spectra measured ex vivo from breast tissues. These models are used to extract the absorption, scattering, and fluorescence properties of malignant and nonmalignant tissues and to diagnose breast cancer ba...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2931078
更新日期:2008-05-01 00:00:00
abstract::Surgical resection of pancreatic cancer represents the only chance of cure and long-term survival in this common disease. Unfortunately, determination of a cancer-free margin at surgery is based on one or two tiny frozen section biopsies, which is far from ideal. Not surprisingly, cancer is usually left behind and is ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.23.4.046501
更新日期:2018-04-01 00:00:00
abstract::The refractive index of blood is a key biophysical parameter, which can reflect the physiological state. We measured the refractive index of whole blood and other components, such as serum, plasma, and hemoglobin, based on internal reflection by using a homemade apparatus in the spectral range of 400 to 750 nm. In add...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.24.3.035003
更新日期:2019-03-01 00:00:00
abstract::We present a quantitative analysis of dynamic diffuse optical measurements to obtain oxygen saturation of hemoglobin in volume oscillating compartments. We used a phasor representation of oscillatory hemodynamics at the heart rate and respiration frequency to separate the oscillations of tissue concentrations of oxyhe...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.10.101408
更新日期:2016-10-01 00:00:00
abstract::As the most abundant cell type in the central nervous system, astrocyte has been one of main research topics in neuroscience. Although various tools have been developed, at present, there is no tool that allows noninvasive activation of astrocyte in vivo without genetic or pharmacological perturbation. Here we report ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3600774
更新日期:2011-07-01 00:00:00
abstract::In a previous study, we investigated physical methods to reduce whole-body, diet-related autofluorescence interference in several mouse strains through changes in animal diet. Measurements of mice with an in vivo multispectral imaging system over a 21-day period allowed for the quantification of concentration changes ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2799188
更新日期:2007-09-01 00:00:00
abstract::The development of methods that allow microscale studies of complex biomaterials based on their molecular composition is of great interest to a wide range of research fields. We show that stimulated Raman scattering (SRS) microscopy is an excellent analytical tool to study distributions of different biomolecules in mu...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3516591
更新日期:2010-11-01 00:00:00
abstract::We assess the properties of contact pressure applied by manually operated fiber-optic probes as a function of the operator, probe contact area, and sample stiffness. First, the mechanical properties of human skin sites with different skin structures, thicknesses, and underlying tissues were studied by in vivo indentat...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.12.127002
更新日期:2015-01-01 00:00:00
abstract::Coherent anti-Stokes Raman scattering (CARS) microscopy is used to determine the distribution and concentration of selected compounds in intact human hair. By generating images based on ratiometric CARS contrast, quantitative concentration maps of both water and externally applied d-glycine are produced in the cortex ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3184444
更新日期:2009-07-01 00:00:00
abstract::Optical coherence tomography (OCT) provides more parameters than pure morphology does. In a recent paper [A. Knuettel and M. Boehlau-Godau, J. Biomed. Opt. 5(1) 83-92 (2000)] we have shown that the refractive index (RI) can be evaluated in a localized manner in skin tissue under in vivo conditions. Based on a theory, ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1647544
更新日期:2004-03-01 00:00:00
abstract::Fluorescent proteins and dyes are routine tools for biological research to describe the behavior of genes, proteins, and cells, as well as more complex physiological dynamics such as vessel permeability and pharmacokinetics. The use of these probes in whole body in vivo imaging would allow extending the range and scop...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.2.026009
更新日期:2016-02-01 00:00:00
abstract::Modern gynecologic practice requires noninvasive diagnostics techniques capable of detecting morphological and functional alterations in tissues of female reproductive organs. Optical coherence tomography (OCT) is a promising tool for providing imaging of biotissues with high resolution at depths up to 2 mm. Design of...
journal_title:Journal of biomedical optics
pub_type: 杂志文章,评审
doi:10.1117/1.JBO.22.12.121709
更新日期:2017-12-01 00:00:00
abstract::Invasive brain cancer cells cannot be visualized during surgery and so they are often not removed. These residual cancer cells give rise to recurrences. journal_title:Journal of biomedical optics pub_type: 杂志文章 doi:10.1117/1.JBO.21.9.094002 更新日期:2016-09-01 00:00:00
abstract::A microelectromechanical system (MEMS) mirror based endoscopic swept-source optical coherence tomography (SS-OCT) system that can perform three-dimensional (3-D) imaging at high speed is reported. The key component enabling 3-D endoscopic imaging is a two-axis MEMS scanning mirror which has a 0.8×0.8 mm2 mirror plate...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.8.086005
更新日期:2013-08-01 00:00:00
abstract::The optical properties of biological tissues under stretching are investigated using a full-field ellipsometry technique based on a differential Mueller matrix formalism. Traditional photoelastic-based formalism for extracting the linear birefringence (LB) properties of stretched anisotropic optical samples ignores th...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.22.3.035006
更新日期:2017-03-01 00:00:00
abstract::A Fourier transform spectrometer is used to simultaneously measure distance, dispersion and spectrum. It is shown that short coherence interferometry has the potential to measure the three-dimensional distribution of the spatial structure of a sample with a resolution determined by the coherence length of the light so...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.429885
更新日期:1998-01-01 00:00:00
abstract::Robot-assisted laparoscopic surgery is becoming an established technique for prostatectomy and is increasingly being explored for other types of cancer. Linking intraoperative imaging techniques, such as fluorescence guidance, with the three-dimensional insights provided by preoperative imaging remains a challenge. Na...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.8.086008
更新日期:2016-08-01 00:00:00
abstract::As molecular imaging moves towards lower detection limits, the elimination of endogenous background signals becomes imperative. We present a facile background-suppression technique that specifically segregates the signal from surface-enhanced Raman scattering (SERS)-active nanoparticles (NPs) from the tissue autofluor...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.17.7.076017
更新日期:2012-07-01 00:00:00