Fast and automatic imaging of immunoenzyme-stained neuronal circuits in the whole brain of Drosophila.

Abstract:

:Knowledge of neuronal wiring and morphogenesis in Drosophila is essential to understand brain function and dysfunction. The immunoenzyme method based on horseradish peroxidase/diaminobenzidine (HRP/DAB) provides high-contrast images to resolve details underlying neuronal architecture. However, the poor staining penetration and a lack of corresponding three-dimensional imaging methodology limit its application. Herein, we modified the HRP/DAB method to stain neuronal circuits in the whole brain of Drosophila. Furthermore, we found that imaging with the micro-optical sectioning tomography system provided a fast and automatic method that could dissect cell-specific neuroanatomical architecture at a submicron voxel resolution.

journal_name

J Biomed Opt

authors

Tian Q,Yuan J,Li Y,Jiang T,Gong H,Zhou W

doi

10.1117/1.JBO.19.9.090506

subject

Has Abstract

pub_date

2014-09-01 00:00:00

pages

90506

issue

9

eissn

1083-3668

issn

1560-2281

pii

1910795

journal_volume

19

pub_type

信件
  • Analysis of the dispersion compensation of acousto-optic deflectors used for multiphoton imaging.

    abstract::The acousto-optic deflector (AOD) is highly preferred in laser scanning microscopy for its fast scanning ability and random-addressing capability. However, its application in two-photon microscopy is frustrated by the dispersion of the AOD, which results in beam distortion and pulse lengthening. We report the analysis...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714061

    authors: Zeng S,Lv X,Bi K,Zhan C,Li D,Chen WR,Xiong W,Jacques SL,Luo Q

    更新日期:2007-03-01 00:00:00

  • Design of synchrotron light source and its beamline dedicated to dual-energy x-ray computed tomography.

    abstract::A synchrotron light source dedicated to medical applications has been designed at National Institute of Radiological Sciences. The storage ring, with circumference of 80 m, is designed for acceleration of 2.3 GeV and a stored current of 420 mA. It is equipped with two multipole wigglers to produce sufficient photon fl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1383062

    authors: Torikoshi M,Tsunoo T,Endo M,Noda K,Kumada M,Yamada S,Soga F,Hyodo K

    更新日期:2001-07-01 00:00:00

  • Intravascular near-infrared fluorescence catheter with ultrasound guidance and blood attenuation correction.

    abstract::Intravascular near-infrared fluorescence (NIRF) imaging offers a new approach for characterizing atherosclerotic plaque, but random catheter positioning within the vessel lumen results in variable light attenuation and can yield inaccurate measurements. We hypothesized that NIRF measurements could be corrected for var...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.5.056009

    authors: Dixon AJ,Hossack JA

    更新日期:2013-05-01 00:00:00

  • Vector extrapolation methods for accelerating iterative reconstruction methods in limited-data photoacoustic tomography.

    abstract::As limited data photoacoustic tomographic image reconstruction problem is known to be ill-posed, the iterative reconstruction methods were proven to be effective in terms of providing good quality initial pressure distribution. Often, these iterative methods require a large number of iterations to converge to a soluti...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.7.071204

    authors: Awasthi N,Kalva SK,Pramanik M,Yalavarthy PK

    更新日期:2018-02-01 00:00:00

  • Computational segmentation of collagen fibers from second-harmonic generation images of breast cancer.

    abstract::Second-harmonic generation (SHG) imaging can help reveal interactions between collagen fibers and cancer cells. Quantitative analysis of SHG images of collagen fibers is challenged by the heterogeneity of collagen structures and low signal-to-noise ratio often found while imaging collagen in tissue. The role of collag...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.1.016007

    authors: Bredfeldt JS,Liu Y,Pehlke CA,Conklin MW,Szulczewski JM,Inman DR,Keely PJ,Nowak RD,Mackie TR,Eliceiri KW

    更新日期:2014-01-01 00:00:00

  • Real-time measurement of the vaginal pressure profile using an optical-fiber-based instrumented speculum.

    abstract::Pelvic organ prolapse (POP) occurs when changes to the pelvic organ support structures cause descent or herniation of the pelvic organs into the vagina. Clinical evaluation of POP is a series of manual measurements known as the pelvic organ prolapse quantification (POP-Q) score. However, it fails to identify the mecha...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.127008

    authors: Parkinson LA,Gargett CE,Young N,Rosamilia A,Vashi AV,Werkmeister JA,Papageorgiou AW,Arkwright JW

    更新日期:2016-12-01 00:00:00

  • Multiphoton fluorescence lifetime imaging of chemotherapy distribution in solid tumors.

    abstract::Doxorubicin is a commonly used chemotherapeutic employed to treat multiple human cancers, including numerous sarcomas and carcinomas. Furthermore, doxorubicin possesses strong fluorescent properties that make it an ideal reagent for modeling drug delivery by examining its distribution in cells and tissues. However, wh...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.11.116010

    authors: Carlson M,Watson AL,Anderson L,Largaespada DA,Provenzano PP

    更新日期:2017-11-01 00:00:00

  • In vivo photoacoustic imaging of major blood vessels in the pancreas and liver during surgery.

    abstract::Abdominal surgeries carry considerable risk of gastrointestinal and intra-abdominal hemorrhage, which could possibly cause patient death. Photoacoustic imaging is one solution to overcome this challenge by providing visualization of major blood vessels during surgery. We investigate the feasibility of in vivo blood ve...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.12.121905

    authors: Kempski KM,Wiacek A,Graham M,González E,Goodson B,Allman D,Palmer J,Hou H,Beck S,He J,Bell MAL

    更新日期:2019-08-01 00:00:00

  • Analysis of the metabolic deterioration of ex vivo skin from ischemic necrosis through the imaging of intracellular NAD(P)H by multiphoton tomography and fluorescence lifetime imaging microscopy.

    abstract::Ex vivo human skin has been used extensively for cosmeceutical and drug delivery studies, transplantable skin allografts, or skin flaps. However, it has a half-life of a few days due to ischemic necrosis. Traditional methods of assessing viability can be time-consuming and provide limited metabolic information. Using ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3466580

    authors: Sanchez WY,Prow TW,Sanchez WH,Grice JE,Roberts MS

    更新日期:2010-07-01 00:00:00

  • Applications of compressive sensing in spatial frequency domain imaging.

    abstract:SIGNIFICANCE:Spatial frequency domain imaging (SFDI) is an imaging modality that projects spatially modulated light patterns to determine optical property maps for absorption and reduced scattering of biological tissue via a pixel-by-pixel data acquisition and analysis procedure. Compressive sensing (CS) is a signal pr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.11.112904

    authors: Mellors BOL,Bentley A,Spear AM,Howle CR,Dehghani H

    更新日期:2020-11-01 00:00:00

  • Motion-compensated noncontact imaging photoplethysmography to monitor cardiorespiratory status during exercise.

    abstract::With the advance of computer and photonics technology, imaging photoplethysmography [(PPG), iPPG] can provide comfortable and comprehensive assessment over a wide range of anatomical locations. However, motion artifact is a major drawback in current iPPG systems, particularly in the context of clinical assessment. To ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3602852

    authors: Sun Y,Hu S,Azorin-Peris V,Greenwald S,Chambers J,Zhu Y

    更新日期:2011-07-01 00:00:00

  • Optical coherence tomography in gynecology: a narrative review.

    abstract::Modern gynecologic practice requires noninvasive diagnostics techniques capable of detecting morphological and functional alterations in tissues of female reproductive organs. Optical coherence tomography (OCT) is a promising tool for providing imaging of biotissues with high resolution at depths up to 2 mm. Design of...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.22.12.121709

    authors: Kirillin M,Motovilova T,Shakhova N

    更新日期:2017-12-01 00:00:00

  • Polarization-correlation mapping of biological tissue coherent images.

    abstract::We investigate the statistical polarization parameters of biological tissue histological section images with different morphological structure. First we outline the results of polarization coordinate mapping and analysis of the statistics of the first to fourth orders of biological tissue image polarization azimuth an...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2148251

    authors: Angelsky OV,Ushenko AG,Ushenko YA,Ushenko YG,Tomka YY,Pishak VP

    更新日期:2005-11-01 00:00:00

  • Study of cadmium-induced cytotoxicity using two-photon excitation endogenous fluorescence microscopy.

    abstract::We demonstrate that using time-resolved two-photon excitation endogenous fluorescence microscopy, the cadmium (Cd)-induced cellular toxic level can be assessed by the free-to protein-bound reduced nicotinamide adenine dinucleotide (free/bound NADH) ratio in a living cell. NADH fluorescence excited at 730 nm is capture...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3250293

    authors: Li D,Yang MS,Lin T,Zheng W,Qu JY

    更新日期:2009-09-01 00:00:00

  • Polarization birefringence measurements for characterizing the myocardium, including healthy, infarcted, and stem-cell-regenerated tissues.

    abstract::Myocardial infarction leads to structural remodeling of the myocardium, in particular to the loss of cardiomyocytes due to necrosis and an increase in collagen with scar formation. Stem cell regenerative treatments have been shown to alter this remodeling process, resulting in improved cardiac function. As healthy myo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3469844

    authors: Wood MF,Ghosh N,Wallenburg MA,Li SH,Weisel RD,Wilson BC,Li RK,Vitkin IA

    更新日期:2010-07-01 00:00:00

  • Detection of Plasmodium falciparum-infected red blood cells by optical stretching.

    abstract::We present the application of a microfluidic optical cell stretcher to measure the elasticity of malaria-infected red blood cells. The measurements confirm an increase in host cell rigidity during the maturation of the parasite Plasmodium falciparum. The device combines the selectivity and sensitivity of single-cell e...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3458919

    authors: Mauritz JM,Tiffert T,Seear R,Lautenschläger F,Esposito A,Lew VL,Guck J,Kaminski CF

    更新日期:2010-05-01 00:00:00

  • Quantitative real-time optical imaging of the tissue metabolic rate of oxygen consumption.

    abstract::The tissue metabolic rate of oxygen consumption (tMRO2) is a clinically relevant marker for a number of pathologies including cancer and arterial occlusive disease. We present and validate a noncontact method for quantitatively mapping tMRO2 over a wide, scalable field of view at 16  frames  /  s. We achieve this by d...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.3.036013

    authors: Ghijsen M,Lentsch GR,Gioux S,Brenner M,Durkin AJ,Choi B,Tromberg BJ

    更新日期:2018-03-01 00:00:00

  • Rapid confocal imaging of large areas of excised tissue with strip mosaicing.

    abstract::Imaging large areas of tissue rapidly and with high resolution may enable rapid pathology at the bedside. The limited field of view of high-resolution microscopes requires the merging of multiple images that are taken sequentially to cover a large area. This merging or mosaicing of images requires long acquisition and...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3582335

    authors: Abeytunge S,Li Y,Larson B,Toledo-Crow R,Rajadhyaksha M

    更新日期:2011-05-01 00:00:00

  • Use of laser tweezers to analyze sperm motility and mitochondrial membrane potential.

    abstract::We combine laser tweezers with custom computer tracking software and robotics to analyze the motility [swimming speed, VCL (curvilinear velocity), and swimming force in terms of escape laser power (Pesc)] and energetics [mitochondrial membrane potential (MP)] of individual sperm. Domestic dog sperm are labeled with a ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2839051

    authors: Nascimento JM,Shi LZ,Chandsawangbhuwana C,Tam J,Durrant B,Botvinick EL,Berns MW

    更新日期:2008-01-01 00:00:00

  • Monitoring of drug and stimulation induced cerebral blood flow velocity changes in rat sensory cortex using spectral domain Doppler optical coherence tomography.

    abstract::Doppler optical coherence tomography (DOCT) provides a novel method to measure blood flow velocity in vessels with diameter at micrometer scale. In this study, a developed spectral domain DOCT system is applied to monitor cerebral blood flow velocity changes in a rat. An animal model with a cranial window is used, and...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3560286

    authors: Wang C,Yang Y,Ding Z,Meng J,Wang K,Yang W,Xu Y

    更新日期:2011-04-01 00:00:00

  • Robot-assisted three-dimensional registration for cochlear implant surgery using a common-path swept-source optical coherence tomography probe.

    abstract::Cochlear implantation offers the potential to restore sensitive hearing in patients with severe to profound deafness. However, surgical placement of the electrode array within the cochlea can produce trauma to sensorineural components, particularly if the initial turn of the cochlea is not successfully navigated as th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.5.057004

    authors: Gurbani SS,Wilkening P,Zhao M,Gonenc B,Cheon GW,Iordachita II,Chien W,Taylor RH,Niparko JK,Kang JU

    更新日期:2014-05-01 00:00:00

  • Anomalous photobleaching in fluorescence recovery after photobleaching measurements due to excitation saturation--a case study for fluorescein.

    abstract::In this study we examine the implications of excitation saturation on fluorescence recovery after photobleaching (FRAP) experiments. In particular we present both experimental and theoretical evidence that fluorescein, one of the most frequently used fluorophores in FRAP, does not always comply with the basic assumpti...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2337531

    authors: Braeckmans K,Stubbe BG,Remaut K,Demeester J,De Smedt SC

    更新日期:2006-07-01 00:00:00

  • Photochemical decontamination of red cell concentrates with the silicon phthalocyanine pc 4 and red light.

    abstract::Virus inactivation in red blood cell concentrates (RBCC) is being studied in order to increase the safety of the blood supply. For this purpose we have been studying the silicon phthalocyanine (Pc 4), a photosensitizer activated with red light. Two approaches were used to achieve enhanced selectivity of Pc 4 for virus...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429931

    authors: Ben-Hur E,Zuk MM,Oetjen J,Chan WS,Lenny L,Horowitz B

    更新日期:1999-07-01 00:00:00

  • Spatiotemporal characteristics of cerebral blood volume changes in rat somatosensory cortex evoked by sciatic nerve stimulation and obtained by optical imaging.

    abstract::The spatiotemporal characteristics of changes in cerebral blood volume associated with neuronal activity were investigated in the hindlimb somatosensory cortex of alpha-chloralose-urethane anesthetized rats (n=10) with optical imaging at 570 nm through a thinned skull. Activation of the cortex was carried out by elect...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1609199

    authors: Li P,Luo Q,Luo W,Chen S,Cheng H,Zeng S

    更新日期:2003-10-01 00:00:00

  • Optimal probe design for breast imaging using near-infrared diffused light.

    abstract::Shallow lesions less than 1.5-cm deep are frequently seen in breast patients when they are scanned in reflection geometry. Two boundary conditions are compared for imaging shallow lesions, and a new probe design is introduced. A partial reflection boundary condition is suitable for imaging shallow lesions less than 1....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2966703

    authors: Xu C,Yuan B,Zhu Q

    更新日期:2008-07-01 00:00:00

  • Cell membrane and gold nanoparticles effects on optical immersion experiments with noncancerous and cancerous cells: finite-difference time-domain modeling.

    abstract::Pilot results on the application of the finite-difference time-domain (FDTD) approach for studying the implementation of the optical immersion technique for the visualization of single and multiple gold nanoparticles in biological cells are presented. We focus on two different scenarios considering single biological c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2400239

    authors: Tanev S,Tuchin VV,Paddon P

    更新日期:2006-11-01 00:00:00

  • Noncontact photoacoustic tomography of in vivo chicken chorioallantoic membrane based on all-fiber heterodyne interferometry.

    abstract::We present three-dimensional (3-D) in vivo photoacoustic (PA) images of the blood vasculature of a chicken chorioallantoic membrane (CAM) obtained by using a fiber-based noncontact PA tomography system. With a fiber-optic heterodyne interferometer, the system measures the surface displacement of a sample, induced by t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.10.106007

    authors: Eom J,Park SJ,Lee BH

    更新日期:2015-10-01 00:00:00

  • Optical oximetry of volume-oscillating vascular compartments: contributions from oscillatory blood flow.

    abstract::We present a quantitative analysis of dynamic diffuse optical measurements to obtain oxygen saturation of hemoglobin in volume oscillating compartments. We used a phasor representation of oscillatory hemodynamics at the heart rate and respiration frequency to separate the oscillations of tissue concentrations of oxyhe...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.10.101408

    authors: Kainerstorfer JM,Sassaroli A,Fantini S

    更新日期:2016-10-01 00:00:00

  • simEye: Computer-based simulation of visual perception under various eye defects using Zernike polynomials.

    abstract::We describe a computer eye model that allows for aspheric surfaces and a three-dimensional computer-based ray-tracing technique to simulate optical properties of the human eye and visual perception under various eye defects. Eye surfaces, such as the cornea, eye lens, and retina, are modeled or approximated by a set o...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2357734

    authors: Fink W,Micol D

    更新日期:2006-09-01 00:00:00

  • Imaging of skin birefringence for human scar assessment using polarization-sensitive optical coherence tomography aided by vascular masking.

    abstract::We demonstrate the in vivo assessment of human scars by parametric imaging of birefringence using polarization-sensitive optical coherence tomography (PS-OCT). Such in vivo assessment is subject to artifacts in the detected birefringence caused by scattering from blood vessels. To reduce these artifacts, we preprocess...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.12.126014

    authors: Gong P,Chin L,Es'haghian S,Liew YM,Wood FM,Sampson DD,McLaughlin RA

    更新日期:2014-12-01 00:00:00