Abstract:
:Abdominal surgeries carry considerable risk of gastrointestinal and intra-abdominal hemorrhage, which could possibly cause patient death. Photoacoustic imaging is one solution to overcome this challenge by providing visualization of major blood vessels during surgery. We investigate the feasibility of in vivo blood vessel visualization for photoacoustic-guided liver and pancreas surgeries. In vivo photoacoustic imaging of major blood vessels in these two abdominal organs was successfully achieved after a laparotomy was performed on two swine. Three-dimensional photoacoustic imaging with a robot-controlled ultrasound (US) probe and color Doppler imaging were used to confirm vessel locations. Blood vessels in the in vivo liver were visualized with energies of 20 to 40 mJ, resulting in 10 to 15 dB vessel contrast. Similarly, an energy of 36 mJ was sufficient to visualize vessels in the pancreas with up to 17.3 dB contrast. We observed that photoacoustic signals were more focused when the light source encountered a major vessel in the liver. This observation can be used to distinguish major blood vessels in the image plane from the more diffuse signals associated with smaller blood vessels in the surrounding tissue. A postsurgery histopathological analysis was performed on resected pancreatic and liver tissues to explore possible laser-related damage. Results are generally promising for photoacoustic-guided abdominal surgery when the US probe is fixed and the light source is used to interrogate the surgical workspace. These findings are additionally applicable to other procedures that may benefit from photoacoustic-guided interventional imaging of the liver and pancreas (e.g., biopsy and guidance of radiofrequency ablation lesions in the liver).
journal_name
J Biomed Optjournal_title
Journal of biomedical opticsauthors
Kempski KM,Wiacek A,Graham M,González E,Goodson B,Allman D,Palmer J,Hou H,Beck S,He J,Bell MALdoi
10.1117/1.JBO.24.12.121905subject
Has Abstractpub_date
2019-08-01 00:00:00pages
1-12issue
12eissn
1083-3668issn
1560-2281pii
JBO-190094SSRjournal_volume
24pub_type
杂志文章abstract::Model-based light scattering spectroscopy (LSS) seemed a promising technique for in-vivo diagnosis of dysplasia in multiple organs. In the studies, the residual spectrum, the difference between the observed and modeled diffuse reflectance spectra, was attributed to single elastic light scattering from epithelial nucle...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3116708
更新日期:2009-03-01 00:00:00
abstract::Optical coherence microscopy (OCM) combines confocal microscopy and optical coherence tomography (OCT) to improve imaging depth and contrast, enabling cellular imaging in human tissues. We aim to investigate OCM for ex vivo imaging of upper and lower gastrointestinal tract tissues, to establish correlations between OC...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3322704
更新日期:2010-01-01 00:00:00
abstract::The attenuation of near-infrared (NIR) light intensity as it propagates in a turbid medium like biological tissue is described by modified the Beer–Lambert law (MBLL). The MBLL is generally used to quantify the changes in tissue chromophore concentrations for NIR spectroscopic data analysis. Even though MBLL is effect...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.7.076012
更新日期:2016-07-01 00:00:00
abstract::Penetration profiles of topically applied drugs and cosmetic products provide important information on their efficacy. The application of tape stripping in combination with UV/VIS spectroscopy is checked to determine the local position of topically applied substances inside the stratum corneum, the penetration profile...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1854683
更新日期:2005-01-01 00:00:00
abstract::Photoacoustic imaging has become an emerging tool for theranostic applications. Not only does it help in journal_title:Journal of biomedical optics pub_type: 杂志文章 doi:10.1117/1.JBO.22.4.041007 更新日期:2017-04-01 00:00:00
abstract::In this study we examine the implications of excitation saturation on fluorescence recovery after photobleaching (FRAP) experiments. In particular we present both experimental and theoretical evidence that fluorescein, one of the most frequently used fluorophores in FRAP, does not always comply with the basic assumpti...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2337531
更新日期:2006-07-01 00:00:00
abstract::Selective photothermal interaction using dye enhancement has proven to be effective in minimizing surrounding tissue damage and delivering energy to target tissue. During laser irradiation, the process of photon absorption and thermal energy diffusion in the target tissue and its surrounding tissue are crucial. Such i...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2204615
更新日期:2006-05-01 00:00:00
abstract::We present functional imaging of the concentration of a photodynamic therapy (PDT)-related dye in scattering tissue phantoms based on spatially resolved measurements of optical properties through spectroscopic optical coherence tomography (OCT). Expressions for the OCT signal are developed, enabling estimation of dept...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1898242
更新日期:2005-03-01 00:00:00
abstract::We propose an algorithm to compensate for the refractive index error in the optical coherence tomography (OCT) images of multilayer tissues, such as skin. The performance of the proposed method has been evaluated on one- and two-layer solid phantoms, as well as the skin of rat paw. ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.23.7.070501
更新日期:2018-07-01 00:00:00
abstract::As the most abundant cell type in the central nervous system, astrocyte has been one of main research topics in neuroscience. Although various tools have been developed, at present, there is no tool that allows noninvasive activation of astrocyte in vivo without genetic or pharmacological perturbation. Here we report ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3600774
更新日期:2011-07-01 00:00:00
abstract::Infrared microscopic imaging has been utilized to analyze for the first time the spatial distribution of lipid structure in an ex vivo human organ culture skin wound healing model. Infrared images were collected at zero, two, four, and six days following wounding. Analysis of lipid infrared spectral properties reveale...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.17.9.096009
更新日期:2012-09-01 00:00:00
abstract::Autofluorescence of the cornea within specific wavelength region and dynamic light scattering measurements of ocular tissue have both been used for early-stage detection of the presence of diabetic retinopathy. In the present study, autofluorescence of the cornea and dynamic light scattering in the cornea and vitreous...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.429882
更新日期:1998-07-01 00:00:00
abstract::Oblique incidence reflectometry (OIR) is an established technique for the estimation of tissue optical properties. However, a sensing footprint of a few transport mean-free paths is often needed when diffusion-regime-based algorithms are used. Smaller-footprint probes require improved light-propagation models and inve...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.6.067005
更新日期:2013-06-01 00:00:00
abstract::The expensive fabrication of current opto-microfluidic sensors is a barrier to the successful adoption of these devices in point-of-care testing. This work reports a simple inexpensive opto-microfluidic device incorporating a poly(dimethylsiloxane)-glass hybrid microfluidic chip modified with gold nanoparticles and a ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.19.3.030504
更新日期:2014-03-01 00:00:00
abstract::A reflectance volume holographic imaging (VHI) endoscope has been designed for simultaneous in vivo imaging of surface and subsurface tissue structures. Prior utilization of VHI systems has been limited to ex vivo tissue imaging. The VHI system presented in this work is designed for laparoscopic use. It consists of a ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.22.5.056010
更新日期:2017-05-01 00:00:00
abstract::We have presented an innovative laser-assisted reduction surgery (LARS) based on plasma-induced ablation and photodisruption effects. In addition, we developed a laser operation system. Fetuses of mice from the Institute for Cancer Research that were immersed in physiological saline were irradiated by convergent-pulse...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.11.118002
更新日期:2013-11-01 00:00:00
abstract:SIGNIFICANCE:In multiphoton microscopy, two-photon excited fluorescence (TPEF) spectra carry valuable information on morphological and functional biological features. For measuring these biomarkers, separation of different parts of the fluorescence spectrum into channels is typically achieved by the use of optical band...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.25.7.071206
更新日期:2020-07-01 00:00:00
abstract::Functional near-infrared spectroscopy (fNIRS), acquired simultaneously with electroencephalography (EEG), allows the investigation of hemodynamic brain responses to epileptic activity. Because the presumed epileptogenic focus is patient-specific, an appropriate source/detector (SD) montage has to be reconfigured for e...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.19.2.026010
更新日期:2014-02-01 00:00:00
abstract::Pulse oximeters are widely used for noninvasive monitoring of oxygen saturation in arterial blood hemoglobin. We present a transmittance pulse oximetry system based on near-infrared (NIR) laser diodes (750 and 850 nm) for monitoring oxygen saturation of arterial blood hemoglobin. The pulse oximetry system is made up o...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1578495
更新日期:2003-07-01 00:00:00
abstract::Frequency domain optical coherence tomography (FD-OCT), based on an all-reflective high-speed InGaAs spectrometer, operating in the 1050 nm wavelength region for retinal diagnostics, enables high-speed, volumetric imaging of retinal pathologies with greater penetration into choroidal tissue is compared to conventional...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2773728
更新日期:2007-07-01 00:00:00
abstract::Animal models are widely used to investigate the pathological mechanisms of spinal cord injury (SCI), most commonly in rats. It is well known that compromised blood flow caused by mechanical disruption of the vasculature can produce irreversible damage and cell death in hypoperfused tissue regions and spinal cord tiss...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.3.037005
更新日期:2013-03-01 00:00:00
abstract::We present the design and experimental results of a new MEMS-based endoscopic optical coherence tomography (OCT) probe. The uniqueness of this miniature OCT imaging probe is a two-axis MEMS mirror with through-silicon vias (TSVs) for interconnecting. The TSV interconnection enables ultracompact probe design, successfu...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3533323
更新日期:2011-02-01 00:00:00
abstract::Previous works investigated a spectroscopic technique that offered a promising alternative to blood and breath assays for determining in vivo alcohol concentration. Although these prior works measured the dorsal forearm, we report the results of a 26-subject clinical study designed to evaluate the spectroscopic techni...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3535594
更新日期:2011-02-01 00:00:00
abstract::With the advance of computer and photonics technology, imaging photoplethysmography [(PPG), iPPG] can provide comfortable and comprehensive assessment over a wide range of anatomical locations. However, motion artifact is a major drawback in current iPPG systems, particularly in the context of clinical assessment. To ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3602852
更新日期:2011-07-01 00:00:00
abstract::Traditional phase-resolved Doppler optical coherence tomography (DOCT) has been reported to have potential for characterizing local fluid flow within a microporous scaffold. In this work, we apply Doppler optical microangiography (DOMAG), a new imaging technique developed by combining optical microangiography (OMAG) w...
journal_title:Journal of biomedical optics
pub_type: 信件
doi:10.1117/1.3233590
更新日期:2009-09-01 00:00:00
abstract::A Monte Carlo algorithm is applied to simulate the measurements of a sample with glass slides sandwiched between the double integrating sphere (DIS) setup. The effects caused by various parameters, such as the sample port of integrating sphere, thicknesses, and optical properties of the sample, on light losses and opt...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2815691
更新日期:2007-11-01 00:00:00
abstract::We present a quantitative analysis of dynamic diffuse optical measurements to obtain oxygen saturation of hemoglobin in volume oscillating compartments. We used a phasor representation of oscillatory hemodynamics at the heart rate and respiration frequency to separate the oscillations of tissue concentrations of oxyhe...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.10.101408
更新日期:2016-10-01 00:00:00
abstract::We present a novel confocal microscope that has dual-axis architecture and biaxial postobjective scanning for the collection of fluorescence images from biological specimens. This design uses two low-numerical-aperture lenses to achieve high axial resolution and long working distance, and the scanning mirror located d...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1760760
更新日期:2004-07-01 00:00:00
abstract::The cyclic peptide, cyclopentapeptide cyclo(lys-Arg-Gly-Asp-phe) (c(KRGDf)), which is known to target alpha(v)beta3 integrin, is dual-labeled with a radiotracer, (111)indium, for gamma scintigraphy as well as with a near-infrared dye, IRDye800, for continuous-wave (cw) imaging of alpha(v)beta3 positive human M21 melan...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2114748
更新日期:2005-09-01 00:00:00
abstract::Metal nanoparticles can be functionalized with biomolecules to selectively localize in precancerous tissues and can act as optical contrast enhancers for reflectance-based diagnosis of epithelial precancer. We carry out Monte Carlo (MC) simulations to analyze photon propagation through nanoparticle-labeled tissues and...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3608999
更新日期:2011-08-01 00:00:00