Imaging of skin birefringence for human scar assessment using polarization-sensitive optical coherence tomography aided by vascular masking.

Abstract:

:We demonstrate the in vivo assessment of human scars by parametric imaging of birefringence using polarization-sensitive optical coherence tomography (PS-OCT). Such in vivo assessment is subject to artifacts in the detected birefringence caused by scattering from blood vessels. To reduce these artifacts, we preprocessed the PS-OCT data using a vascular masking technique. The birefringence of the remaining tissue regions was then automatically quantified. Results from the scars and contralateral or adjacent normal skin of 13 patients show a correspondence of birefringence with scar type: the ratio of birefringence of hypertrophic scars to corresponding normal skin is 2.2 ± 0.2 (mean ± standard deviation ), while the ratio of birefringence of normotrophic scars to normal skin is 1.1 ± 0.4 . This method represents a new clinically applicable means for objective, quantitative human scar assessment.

journal_name

J Biomed Opt

authors

Gong P,Chin L,Es'haghian S,Liew YM,Wood FM,Sampson DD,McLaughlin RA

doi

10.1117/1.JBO.19.12.126014

subject

Has Abstract

pub_date

2014-12-01 00:00:00

pages

126014

issue

12

eissn

1083-3668

issn

1560-2281

pii

2088614

journal_volume

19

pub_type

杂志文章
  • Filter-based method for background removal in high-sensitivity wide-field-surface-enhanced Raman scattering imaging in vivo.

    abstract::As molecular imaging moves towards lower detection limits, the elimination of endogenous background signals becomes imperative. We present a facile background-suppression technique that specifically segregates the signal from surface-enhanced Raman scattering (SERS)-active nanoparticles (NPs) from the tissue autofluor...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.076017

    authors: Mallia RJ,McVeigh PZ,Veilleux I,Wilson BC

    更新日期:2012-07-01 00:00:00

  • Combined ultrasound and photoacoustic imaging to detect and stage deep vein thrombosis: phantom and ex vivo studies.

    abstract::Treatment of deep venous thrombosis (DVT)--a primary cause of potentially fatal pulmonary embolism (PE)--depends on the age of the thrombus. The existing clinical imaging methods are capable of visualizing a thrombus but cannot determine the age of the blood clot. Therefore, there is a need for an imaging technique to...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2992175

    authors: Karpiouk AB,Aglyamov SR,Mallidi S,Shah J,Scott WG,Rubin JM,Emelianov SY

    更新日期:2008-09-01 00:00:00

  • Determination of optical properties of human blood in the spectral range 250 to 1100 nm using Monte Carlo simulations with hematocrit-dependent effective scattering phase functions.

    abstract::The absorption coefficient mu(a), scattering coefficient mu(s), and anisotropy factor g of diluted and undiluted human blood (hematocrit 0.84 and 42.1%) are determined under flow conditions in the wavelength range 250 to 1100 nm, covering the absorption bands of hemoglobin. These values are obtained by high precision ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2203659

    authors: Friebel M,Roggan A,Müller G,Meinke M

    更新日期:2006-05-01 00:00:00

  • Subcellular imaging of epithelium with time-lapse optical coherence tomography.

    abstract::We present the first experimental result of direct delineation of the nuclei of living rat bladder epithelium with ultrahigh-resolution optical coherence tomography (uOCT). We demonstrate that the cellular details embedded in the speckle noise in a uOCT image can be uncovered by time-lapse frame averaging that takes a...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.2800007

    authors: Pan YT,Wu ZL,Yuan ZJ,Wang ZG,Du CW

    更新日期:2007-09-01 00:00:00

  • Optimal probe design for breast imaging using near-infrared diffused light.

    abstract::Shallow lesions less than 1.5-cm deep are frequently seen in breast patients when they are scanned in reflection geometry. Two boundary conditions are compared for imaging shallow lesions, and a new probe design is introduced. A partial reflection boundary condition is suitable for imaging shallow lesions less than 1....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2966703

    authors: Xu C,Yuan B,Zhu Q

    更新日期:2008-07-01 00:00:00

  • Hyperspectral imaging based method for fast characterization of kidney stone types.

    abstract::The formation of kidney stones is a common and highly studied disease, which causes intense pain and presents a high recidivism. In order to find the causes of this problem, the characterization of the main compounds is of great importance. In this sense, the analysis of the composition and structure of the stone can ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.076027

    authors: Blanco F,López-Mesas M,Serranti S,Bonifazi G,Havel J,Valiente M

    更新日期:2012-07-01 00:00:00

  • Multimodal optical microscope for detecting viability of mouse embryos in vitro.

    abstract::We present a multimodal optical microscope that incorporates six imaging modalities on one common platform. The imaging modalities include three staring modes, optical quadrature microscopy (OQM), differential interference contrast (DIC) microscopy, and epi-fluorescence microscopy, and three scanning modes, confocal r...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2753744

    authors: Warger WC 2nd,Laevsky GS,Townsend DJ,Rajadhyaksha M,DiMarzio CA

    更新日期:2007-07-01 00:00:00

  • Simultaneous measurement of dispersion, spectrum, and distance with a fourier transform spectrometer.

    abstract::A Fourier transform spectrometer is used to simultaneously measure distance, dispersion and spectrum. It is shown that short coherence interferometry has the potential to measure the three-dimensional distribution of the spatial structure of a sample with a resolution determined by the coherence length of the light so...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429885

    authors: Hellmuth T,Welle M

    更新日期:1998-01-01 00:00:00

  • Real-time intraoperative fluorescence imaging system using light-absorption correction.

    abstract::We present a novel fluorescence imaging system developed for real-time interventional imaging applications. The system implements a correction scheme that improves the accuracy of epi-illumination fluorescence images for light intensity variation in tissues. The implementation is based on the use of three cameras oper...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3259362

    authors: Themelis G,Yoo JS,Soh KS,Schulz R,Ntziachristos V

    更新日期:2009-11-01 00:00:00

  • Self-mixing in a diode laser as a method for cardiovascular diagnostics.

    abstract::Our aim is the development of a simple optical method for pulse wave profile, pulse wave delay time, and blood flow measurement. The method is based on recording the Doppler frequency shift related to a moving target--blood vessel walls or small particles. The Doppler signal is detected using the self-mixing that occu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1528949

    authors: Meigas K,Hinrikus H,Kattai R,Lass J

    更新日期:2003-01-01 00:00:00

  • Optically sectioned in vivo imaging with speckle illumination HiLo microscopy.

    abstract::We present a simple wide-field imaging technique, called HiLo microscopy, that is capable of producing optically sectioned images in real time, comparable in quality to confocal laser scanning microscopy. The technique is based on the fusion of two raw images, one acquired with speckle illumination and another with st...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3528656

    authors: Lim D,Ford TN,Chu KK,Mertz J

    更新日期:2011-01-01 00:00:00

  • Clinical study of noninvasive in vivo melanoma and nonmelanoma skin cancers using multimodal spectral diagnosis.

    abstract::The goal of this study was to determine the diagnostic capability of a multimodal spectral diagnosis (SD) for in vivo noninvasive disease diagnosis of melanoma and nonmelanoma skin cancers. We acquired reflectance, fluorescence, and Raman spectra from 137 lesions in 76 patients using custom-built optical fiber-based c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.117003

    authors: Lim L,Nichols B,Migden MR,Rajaram N,Reichenberg JS,Markey MK,Ross MI,Tunnell JW

    更新日期:2014-01-01 00:00:00

  • Attenuated total reflection Fourier transform infrared and polarization spectroscopy of in vivo human skin ablated, layer by layer, by erbium:YAG laser.

    abstract::The results of an experimental study of the possibilities of monitoring erbium yttrium aluminum garnet laser-mediated ablation of human epidermis with the use of Fourier transform infrared (FTIR) spectroscopy and spectral polarization techniques are presented. The attenuated total reflection (ATR) method was used for ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1755719

    authors: Sviridov AP,Zimnyakov DA,Sinichkin YP,Butvina LN,Omelchenko AJ,Shakh GS,Bagratashvili VN

    更新日期:2004-07-01 00:00:00

  • Appearance of breast cysts in planar geometry photoacoustic mammography using 1064-nm excitation.

    abstract::In the search for improved imaging modalities for detection and diagnosis of breast cancer, a high negative prediction value is also important. Photoacoustic (optoacoustic) imaging is a relatively new technique that has high potential for visualizing breast malignancies, but little is known about the photoacoustic app...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.12.126009

    authors: Heijblom M,Piras D,Maartens E,Huisman EJ,van den Engh FM,Klaase JM,Steenbergen W,Manohar S

    更新日期:2013-12-01 00:00:00

  • Optical properties of adenocarcinoma and squamous cell carcinoma of the gastroesophageal junction.

    abstract::Photodynamic therapy (PDT) is an alternative to radical surgical resection for T1a or nonresectable carcinomas of the gastroesophageal junction. Besides the concentration of the photosensitizer, the light distribution in tissue is responsible for tumor destruction. For this reason, knowledge about the behavior of ligh...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2564793

    authors: Holmer C,Lehmann KS,Wanken J,Reissfelder C,Roggan A,Mueller G,Buhr HJ,Ritz JP

    更新日期:2007-01-01 00:00:00

  • Average-power mediated ultrafast laser osteotomy using a mode-locked Nd:YVO4 laser oscillator.

    abstract::By using a novel temporal characterization technique, we determined that a threshold average laser power of 160 mW is required to drill through a 0.75-mm-thick cortical bone for a Nd:YVO(4) mode-locked laser oscillator with a peak intensity of 1.3 GWcm(2). The ablation mechanism is identified as average-power induced ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2821149

    authors: Lee YM,Tu RY,Chiang AC,Huang YC

    更新日期:2007-11-01 00:00:00

  • Intraoperative hyperspectral determination of human tissue properties.

    abstract::We address the automatic differentiation of human tissue using multispectral imaging with promising potential for automatic visualization during surgery. Currently, tissue types have to be continuously differentiated based on the surgeon's knowledge only. Further, automatic methods based on optical in vivo properties ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.9.091409

    authors: Wisotzky EL,Uecker FC,Arens P,Dommerich S,Hilsmann A,Eisert P

    更新日期:2018-05-01 00:00:00

  • Calibration of diffuse correlation spectroscopy blood flow index with venous-occlusion diffuse optical spectroscopy in skeletal muscle.

    abstract::We investigate and assess the utility of a simple scheme for continuous absolute blood flow monitoring based on diffuse correlation spectroscopy (DCS). The scheme calibrates DCS using venous-occlusion diffuse optical spectroscopy (VO-DOS) measurements of arm muscle tissue at a single time-point. A calibration coeffici...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.12.125005

    authors: Li Z,Baker WB,Parthasarathy AB,Ko TS,Wang D,Schenkel S,Durduran T,Li G,Yodh AG

    更新日期:2015-01-01 00:00:00

  • Ambulatory diffuse optical tomography and multimodality physiological monitoring system for muscle and exercise applications.

    abstract::Ambulatory diffuse optical tomography (aDOT) is based on near-infrared spectroscopy (NIRS) and enables three-dimensional imaging of regional hemodynamics and oxygen consumption during a person’s normal activities. Although NIRS has been previously used for muscle assessment, it has been notably limited in terms of the...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.9.091314

    authors: Hu G,Zhang Q,Ivkovic V,Strangman GE

    更新日期:2016-09-01 00:00:00

  • No-core fiber-based highly sensitive optical fiber pH sensor.

    abstract::The present work describes the fabrication and characterization of an optical fiber pH sensor using a sol–gel technique. The sensing head configuration is incorporated using a short section of no-core fiber, coated with tetraethyl orthosilicate and spliced at the end of a single mode fiber with a bulge. Different type...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.5.057001

    authors: Bhardwaj V,Pathak AK,Singh VK

    更新日期:2017-05-01 00:00:00

  • Detection of Plasmodium falciparum-infected red blood cells by optical stretching.

    abstract::We present the application of a microfluidic optical cell stretcher to measure the elasticity of malaria-infected red blood cells. The measurements confirm an increase in host cell rigidity during the maturation of the parasite Plasmodium falciparum. The device combines the selectivity and sensitivity of single-cell e...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3458919

    authors: Mauritz JM,Tiffert T,Seear R,Lautenschläger F,Esposito A,Lew VL,Guck J,Kaminski CF

    更新日期:2010-05-01 00:00:00

  • Photoacoustic needle: minimally invasive guidance to biopsy.

    abstract::We introduce a needle probe based on photoacoustics (PA) to extend the scope of optical needle methods in guiding biopsies. Pulsed light is coupled to an optical fiber in a needle to be inserted in tissue, and PA signals are detected using an ultrasound imager used for needle guidance. This PA needle samples large vol...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.7.070502

    authors: Piras D,Grijsen C,Schütte P,Steenbergen W,Manohar S

    更新日期:2013-07-01 00:00:00

  • Virtual organelle self-coding for fluorescence imaging via adversarial learning.

    abstract:SIGNIFICANCE:Our study introduces an application of deep learning to virtually generate fluorescence images to reduce the burdens of cost and time from considerable effort in sample preparation related to chemical fixation and staining. AIM:The objective of our work was to determine how successfully deep learning meth...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.9.096009

    authors: Nguyen T,Bui V,Thai A,Lam V,Raub C,Chang LC,Nehmetallah G

    更新日期:2020-09-01 00:00:00

  • Analysis of the efficiency of hair removal by different optical methods: comparison of Trichoscan, reflectance confocal microscopy, and optical coherence tomography.

    abstract::Noninvasive diagnostic tools, such as Trichoscan®, reflectance confocal microscopy (RCM), and optical coherence tomography (OCT), are efficient methods of hair shaft and growth evaluation. The aim of this study was to carry out a comparative assessment of these three medical procedures by measuring the hair shaft and ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,随机对照试验

    doi:10.1117/1.JBO.17.10.101504

    authors: Kuck M,Schanzer S,Ulrich M,Garcia Bartels N,Meinke MC,Fluhr J,Krah M,Blume-Peytavi U,Stockfleth E,Lademann J

    更新日期:2012-10-01 00:00:00

  • Hardware implementation algorithm and error analysis of high-speed fluorescence lifetime sensing systems using center-of-mass method.

    abstract::A new, simple, high-speed, and hardware-only integration-based fluorescence-lifetime-sensing algorithm using a center-of-mass method (CMM) is proposed to implement lifetime calculations, and its signal-to-noise-ratio based on statistics theory is also deduced. Compared to the commonly used iterative least-squares meth...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3309737

    authors: Li DU,Rae B,Andrews R,Arlt J,Henderson R

    更新日期:2010-01-01 00:00:00

  • Biochemical analysis of human breast tissues using Fourier-transform Raman spectroscopy.

    abstract::We employ Fourier-transform Raman spectroscopy to study normal and tumoral human breast tissues, including several subtypes of cancers. We analyzed 194 Raman spectra from breast tissues that were separated into 9 groups according to their corresponding histopathological diagnosis. The assignment of the relevant Raman ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2363362

    authors: Bitar RA,Martinho Hda S,Tierra-Criollo CJ,Zambelli Ramalho LN,Netto MM,Martin AA

    更新日期:2006-09-01 00:00:00

  • Integration of a Raman spectroscopy system to a robotic-assisted surgical system for real-time tissue characterization during radical prostatectomy procedures.

    abstract::Surgical excision of the whole prostate through a radical prostatectomy procedure is part of the standard of care for prostate cancer. Positive surgical margins (cancer cells having spread into surrounding nonresected tissue) occur in as many as 1 in 5 cases and strongly correlate with disease recurrence and the requi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.2.025001

    authors: Pinto M,Zorn KC,Tremblay JP,Desroches J,Dallaire F,Aubertin K,Marple E,Kent C,Leblond F,Trudel D,Lesage F

    更新日期:2019-02-01 00:00:00

  • Theory and practical recommendations for autocorrelation-based image correlation spectroscopy.

    abstract::Image correlation spectroscopy (ICS) is a powerful technique for detecting arrangement of fluorophores in images. This tutorial gives background into the mathematical underpinnings of ICS, specifically image autocorrelation. The effects of various artifacts and image processing steps, including background subtraction,...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.080801

    authors: Robertson C,George SC

    更新日期:2012-08-01 00:00:00

  • Site-specific gene transfer into the rat spinal cord by photomechanical waves.

    abstract::Nonviral, site-specific gene delivery to deep tissue is required for gene therapy of a spinal cord injury. However, an efficient method satisfying these requirements has not been established. This study demonstrates efficient and targeted gene transfer into the spinal cord by using photomechanical waves (PMWs), which ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3642014

    authors: Ando T,Sato S,Toyooka T,Uozumi Y,Nawashiro H,Ashida H,Obara M

    更新日期:2011-10-01 00:00:00

  • Spatiotemporal laser speckle contrast analysis for blood flow imaging with maximized speckle contrast.

    abstract::Laser speckle contrast imaging is a technique used for imaging blood flow without scanning. Though several studies have attempted to combine spatial and temporal statistics of laser speckle images for reducing image noise as well as preserving acceptable spatiotemporal resolution, the statistical accuracy of these spa...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3290804

    authors: Qiu J,Li P,Luo W,Wang J,Zhang H,Luo Q