Monitoring of drug and stimulation induced cerebral blood flow velocity changes in rat sensory cortex using spectral domain Doppler optical coherence tomography.

Abstract:

:Doppler optical coherence tomography (DOCT) provides a novel method to measure blood flow velocity in vessels with diameter at micrometer scale. In this study, a developed spectral domain DOCT system is applied to monitor cerebral blood flow velocity changes in a rat. An animal model with a cranial window is used, and by application of a drug, light, and electric stimulations, changes in blood flow velocity of the pial artery in sensory cortex are measured in real time. The results show significant differences in blood flow velocity before and after drug administration or light and electric stimulations, demonstrating the feasibility of DOCT in cerebral microcirculation study. Given its noninvasive nature, high spatial resolution, high velocity sensitivity, and high imaging speed, DOCT shows great promise in brain research by imaging blood flow changes at micrometer scale vessels, which helps to understand the pathogenesis of cerebral diseases and neurodegenerative diseases.

journal_name

J Biomed Opt

authors

Wang C,Yang Y,Ding Z,Meng J,Wang K,Yang W,Xu Y

doi

10.1117/1.3560286

subject

Has Abstract

pub_date

2011-04-01 00:00:00

pages

046001

issue

4

eissn

1083-3668

issn

1560-2281

journal_volume

16

pub_type

杂志文章
  • FLIM data analysis based on Laguerre polynomial decomposition and machine-learning.

    abstract:SIGNIFICANCE:The potential of fluorescence lifetime imaging microscopy (FLIM) is recently being recognized, especially in biological studies. However, FLIM does not directly measure the lifetimes, rather it records the fluorescence decay traces. The lifetimes and/or abundances have to be estimated from these traces dur...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.26.2.022909

    authors: Guo S,Silge A,Bae H,Tolstik T,Meyer T,Matziolis G,Schmitt M,Popp J,Bocklitz T

    更新日期:2021-01-01 00:00:00

  • Discovery of the near-infrared window into the body and the early development of near-infrared spectroscopy.

    abstract::Extension of optical monitoring of intact tissues from the visible and ultraviolet to the near-infrared (NIR) range (700-1300 nm) was first undertaken in 1977 for the purpose of monitoring the redox behavior of Cytochrome c oxidase (cyt c ox) in vivo. Soon it became evident that the much greater NIR translucency of sk...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429952

    authors: Jo Bsis-Vandervliet FF

    更新日期:1999-10-01 00:00:00

  • Toward soft-tissue elastography using digital holography to monitor surface acoustic waves.

    abstract::Measuring the elasticity distribution inside the human body is of great interest because elastic abnormalities can serve as indicators of several diseases. We present a method for mapping elasticity inside soft tissues by imaging surface acoustic waves (SAWs) with digital holographic interferometry. With this method, ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3646211

    authors: Li S,Mohan KD,Sanders WW,Oldenburg AL

    更新日期:2011-11-01 00:00:00

  • Vessel orientation-dependent sensitivity of optoacoustic imaging using a linear array transducer.

    abstract::For clinical optoacoustic imaging, linear probes are preferably used because they allow versatile imaging of the human body with real-time display and free-hand probe guidance. The two-dimensional (2-D) optoacoustic image obtained with this type of probe is generally interpreted as a 2-D cross-section of the tissue ju...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.2.026011

    authors: Preisser S,Bush NL,Gertsch-Grover AG,Peeters S,Bailey AE,Bamber JC,Frenz M,Jaeger M

    更新日期:2013-02-01 00:00:00

  • Dynamic performance of microelectromechanical systems deformable mirrors for use in an active/adaptive two-photon microscope.

    abstract::Active optics such as deformable mirrors can be used to control both focal depth and aberrations during scanning laser microscopy. If the focal depth can be changed dynamically during scanning, then imaging of oblique surfaces becomes possible. If aberrations can be corrected dynamically during scanning, an image can ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.121507

    authors: Archer-Zhang CC,Foster WB,Downey RD,Arrasmith CL,Dickensheets DL

    更新日期:2016-12-01 00:00:00

  • Pancreatic cancer cell detection by targeted lipid microbubbles and multiphoton imaging.

    abstract::Surgical resection of pancreatic cancer represents the only chance of cure and long-term survival in this common disease. Unfortunately, determination of a cancer-free margin at surgery is based on one or two tiny frozen section biopsies, which is far from ideal. Not surprisingly, cancer is usually left behind and is ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.4.046501

    authors: Cromey B,McDaniel A,Matsunaga T,Vagner J,Kieu KQ,Banerjee B

    更新日期:2018-04-01 00:00:00

  • Modulation transfer function measurement of scanning reflectance microscopes.

    abstract::Real-time medical imaging systems such as reflectance confocal microscopes and optical coherence microscopes are being tested in multiple-patient and multiple-center clinical trials. The modulation transfer function (MTF) of these systems at any given time influences the image information content and can affect the in...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2779352

    authors: Wang Z,Glazowski CE,Zavislan JM

    更新日期:2007-09-01 00:00:00

  • Using ultrahigh sensitive optical microangiography to achieve comprehensive depth resolved microvasculature mapping for human retina.

    abstract::This paper presents comprehensive and depth-resolved retinal microvasculature images within human retina achieved by a newly developed ultrahigh sensitive optical microangiography (UHS-OMAG) system. Due to its high flow sensitivity, UHS-OMAG is much more sensitive to tissue motion due to the involuntary movement of th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3642638

    authors: An L,Shen TT,Wang RK

    更新日期:2011-10-01 00:00:00

  • Simultaneous imaging of multiple focal planes for three-dimensional microscopy using ultra-high-speed adaptive optics.

    abstract::Traditional white-light and fluorescent imaging techniques provide powerful methods to extract high-resolution information from two-dimensional (2-D) sections, but to retrieve information from a three-dimensional (3-D) volume they require relatively slow scanning methods that result in increased acquisition time. Usin...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.17.5.050505

    authors: Duocastella M,Sun B,Arnold CB

    更新日期:2012-05-01 00:00:00

  • Bioluminescence of Vibrio fischeri: bacteria respond quickly and sensitively to pulsed microwave electric (but not magnetic) fields.

    abstract::Biological systems with intrinsic luminescent properties serve as powerful and noninvasive bioreporters for real-time and label-free monitoring of cell physiology. This study employs the bioluminescent marine bacterium Vibrio fischeri to investigate the effects of separated microwave electric (E) and magnetic (H) fiel...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.5.051412

    authors: Williams CF,Geroni GM,Lloyd D,Choi H,Clark N,Pirog A,Lees J,Porch A

    更新日期:2019-02-01 00:00:00

  • Coregistered optical coherence tomography and frequency-encoded multispectral imaging for spectrally sparse color imaging.

    abstract::We present a system combining optical coherence tomography (OCT) and multispectral imaging (MSI) for coregistered structural imaging and surface color imaging. We first describe and numerically validate an optimization model to guide the selection of the MSI wavelengths and their relative intensities. We then demonstr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.3.032008

    authors: Attendu X,Bourget MH,de Sivry-Houle MP,Boudoux C

    更新日期:2019-11-01 00:00:00

  • Dialysis-assisted fiber optic spectroscopy for in situ biomedical sensing.

    abstract::A miniature fiber optic spectrometer enclosed within a semipermeable (dialysis) membrane is proposed for in vivo interstitial sensing applications. The semipermeable membrane acts as a molecular filter, allowing only small molecules to pass through to the sampling volume. This filtering, in principle, should enable co...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2166086

    authors: Blazkiewicz P,Blazkiewicz K,Verhaege A,Anissimov YG,Roberts MS,Zvyagin AV

    更新日期:2006-01-01 00:00:00

  • Angiography with a multifunctional line scanning ophthalmoscope.

    abstract::A multifunctional line scanning ophthalmoscope (mLSO) was designed, constructed, and tested on human subjects. The mLSO could sequentially acquire wide-field, confocal, near-infrared reflectance, fluorescein angiography (FA), and indocyanine green angiography (ICGA) retinal images. The system also included a retinal t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.2.026008

    authors: Hammer DX,Ferguson RD,Patel AH,Vazquez V,Husain D

    更新日期:2012-02-01 00:00:00

  • Context encoding enables machine learning-based quantitative photoacoustics.

    abstract::Real-time monitoring of functional tissue parameters, such as local blood oxygenation, based on optical imaging could provide groundbreaking advances in the diagnosis and interventional therapy of various diseases. Although photoacoustic (PA) imaging is a modality with great potential to measure optical absorption dee...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.5.056008

    authors: Kirchner T,Gröhl J,Maier-Hein L

    更新日期:2018-05-01 00:00:00

  • Lamellar keratoplasty using position-guided surgical needle and M-mode optical coherence tomography.

    abstract::Deep anterior lamellar keratoplasty (DALK) is an emerging surgical technique for the restoration of corneal clarity and vision acuity. The big-bubble technique in DALK surgery is the most essential procedure that includes the air injection through a thin syringe needle to separate the dysfunctional region of the corne...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.12.125005

    authors: Shin S,Bae JK,Ahn Y,Kim H,Choi G,Yoo YS,Joo CK,Moon S,Jung W

    更新日期:2017-12-01 00:00:00

  • Near infrared fluorescent optical imaging for nodal staging.

    abstract::Current techniques to assess lymph node metastases in cancer patients include lymphoscintigraphy after administration of a nonspecific radiocolloid in order to locate and resect lymph nodes for pathological examination of harbored cancer cells. Clinical trials involving intradermal or subcutaneous injection of antibod...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.2953498

    authors: Sampath L,Wang W,Sevick-Muraca EM

    更新日期:2008-07-01 00:00:00

  • SpineLab: tool for three-dimensional reconstruction of neuronal cell morphology.

    abstract::SpineLab is a software tool developed for reconstructing neuronal feature skeletons from three-dimensional single- or multi-photon image stacks. These images often suffer from limited resolution and a low signal-to-noise ratio, making the extraction of morphometric information difficult. To overcome this limitation, w...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.076007

    authors: Jungblut D,Vlachos A,Schuldt G,Zahn N,Deller T,Wittum G

    更新日期:2012-07-01 00:00:00

  • Determination of penetration profiles of topically applied substances by means of tape stripping and optical spectroscopy: UV filter substance in sunscreens.

    abstract::Penetration profiles of topically applied drugs and cosmetic products provide important information on their efficacy. The application of tape stripping in combination with UV/VIS spectroscopy is checked to determine the local position of topically applied substances inside the stratum corneum, the penetration profile...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1854683

    authors: Weigmann HJ,Jacobi U,Antoniou C,Tsikrikas GN,Wendel V,Rapp C,Gers-Barlag H,Sterry W,Lademann J

    更新日期:2005-01-01 00:00:00

  • Optical imaging of hard and soft dental tissues using discretely swept optical frequency domain reflectometry optical coherence tomography at wavelengths from 1560 to 1600 nm.

    abstract::We have been developing a Mach-Zehnder type of optical frequency domain reflectometry optical coherence tomography (OFDR-OCT) that uses discretely swept superstructure-grating distributed Bragg- reflector (SSG-DBR) lasers developed for telecommunication fields and has a 12-mm-depth range. We report images obtained wit...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2839042

    authors: Kakuma H,Ohbayashi K,Arakawa Y

    更新日期:2008-01-01 00:00:00

  • Identification of abnormal motor cortex activation patterns in children with cerebral palsy by functional near-infrared spectroscopy.

    abstract::We demonstrate the utility of functional near-infrared spectroscopy (fNIRS) as a tool for physicians to study cortical plasticity in children with cerebral palsy (CP). Motor cortex activation patterns were studied in five healthy children and five children with CP (8.4+/-2.3 years old in both groups) performing a fing...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3432746

    authors: Khan B,Tian F,Behbehani K,Romero MI,Delgado MR,Clegg NJ,Smith L,Reid D,Liu H,Alexandrakis G

    更新日期:2010-05-01 00:00:00

  • Optical power transfer and communication methods for wireless implantable sensing platforms.

    abstract::Ultrasmall scale implants have recently attracted focus as valuable tools for monitoring both acute and chronic diseases. Semiconductor optical technologies are the key to miniaturizing these devices to the long-sought sub-mm scale, which will enable long-term use of these devices for medical applications. This can al...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.9.095012

    authors: Mujeeb-U-Rahman M,Adalian D,Chang CF,Scherer A

    更新日期:2015-09-01 00:00:00

  • Continuous-wave circular polarization terahertz imaging.

    abstract::Biomedical applications of terahertz (THz) radiation are appealing because THz radiation is nonionizing and has the demonstrated ability to detect intrinsic contrasts between cancerous and normal tissue. A linear polarization-sensitive detection technique for tumor margin delineation has already been demonstrated; how...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.7.070502

    authors: Martin JP,Joseph CS,Giles RH

    更新日期:2016-07-01 00:00:00

  • In vivo super-resolution retinal imaging through virtually structured detection.

    abstract::High resolution is important for sensitive detection of subtle distortions of retinal morphology at an early stage of eye diseases. We demonstrate virtually structured detection (VSD) as a feasible method to achieve in vivo super-resolution ophthalmoscopy. A line-scanning strategy was employed to achieve a super-resol...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.120502

    authors: Liu C,Zhi Y,Wang B,Thapa D,Chen Y,Alam M,Lu Y,Yao X

    更新日期:2016-12-01 00:00:00

  • Dependence of image quality on image operator and noise for optical diffusion tomography.

    abstract::By applying linear perturbation theory to the radiation transport equation, the inverse problem of optical diffusion tomography can be reduced to a set of linear equations, Wμ=R, where W is the weight function, μ are the cross-section perturbations to be imaged, and R is the detector readings perturbations. We have st...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429870

    authors: Chang J,Graber HL,Barbour RL

    更新日期:1998-04-01 00:00:00

  • Changes in the redox state and endogenous fluorescence of in vivo human skin due to intrinsic and photo-aging, measured by multiphoton tomography with fluorescence lifetime imaging.

    abstract::Ultraviolet radiation from solar exposure is a key extrinsic factor responsible for premature skin aging (i.e., photo-aging). Recent advances using in vivo multiphoton tomography (MPT) demonstrate the efficacy of this approach to assess intrinsic and extrinsic skin aging as an alternative to existing invasive techniqu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.6.061217

    authors: Sanchez WY,Obispo C,Ryan E,Grice JE,Roberts MS

    更新日期:2013-06-01 00:00:00

  • Fluorescent ZnCdS nanoparticles for glucose sensing.

    abstract::The effect of glucose on fluorescence of synthesized ZnCdS nanoparticles in the presence of glucose oxidase or in a mixture of glucose oxidase and peroxidase has been investigated. Behavior of fluorescence characteristics of ZnCdS nanoparticles with nonstabilized surface and coated with polymer shell is compared. It h...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.1.011020

    authors: Kochubey VI,Volkova EK,Konyukhova JG

    更新日期:2014-01-01 00:00:00

  • Design and validation of an angle-resolved low-coherence interferometry fiber probe for in vivo clinical measurements of depth-resolved nuclear morphology.

    abstract::We present a novel Fourier-domain angle-resolved low-coherence interferometry (a /LCI) fiber probe designed for in vivo clinical application in gastrointestinal endoscopy. The a/LCI technique measures the depth-resolved angular scattering distribution to determine the size distribution and optical density of cell nucl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3520130

    authors: Zhu Y,Terry NG,Woosley JT,Shaheen NJ,Wax A

    更新日期:2011-01-01 00:00:00

  • Spatially confined and temporally resolved refractive index and scattering evaluation in human skin performed with optical coherence tomography.

    abstract::In the present applications of optical coherence tomography (OCT), parameters besides pure morphology are evaluated in skin tissue under in vivo conditions. Spatially mapped refractive indices and scattering coefficients may support tissue characterization for research and diagnostic purposes in cosmetics/pharmacy and...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.429972

    authors: Knüttel A,Boehlau-Godau M

    更新日期:2000-01-01 00:00:00

  • Resolution in the ApoTome and the confocal laser scanning microscope: comparison.

    abstract::The essential feature of the confocal laser scanning microscope (cLSM) is the generation of optical sections by the removal of out-of-focus light. About ten years ago, structured illumination microscopy (SIM) was introduced as an alternative method for obtaining optical sections from biological specimens. Here we comp...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3083439

    authors: Weigel A,Schild D,Zeug A

    更新日期:2009-01-01 00:00:00

  • Augmented microscopy: real-time overlay of bright-field and near-infrared fluorescence images.

    abstract::Intraoperative applications of near-infrared (NIR) fluorescent contrast agents can be aided by instrumentation capable of merging the view of surgical field with that of NIR fluorescence. We demonstrate augmented microscopy, an intraoperative imaging technique in which bright-field (real) and electronically processed ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.10.106002

    authors: Watson JR,Gainer CF,Martirosyan N,Skoch J,Lemole GM Jr,Anton R,Romanowski M

    更新日期:2015-10-01 00:00:00