Optical oximetry of volume-oscillating vascular compartments: contributions from oscillatory blood flow.

Abstract:

:We present a quantitative analysis of dynamic diffuse optical measurements to obtain oxygen saturation of hemoglobin in volume oscillating compartments. We used a phasor representation of oscillatory hemodynamics at the heart rate and respiration frequency to separate the oscillations of tissue concentrations of oxyhemoglobin (O) and deoxyhemoglobin (D) into components due to blood volume (subscript V V ) and blood flow (subscript F F ): O=O V +O F O=OV+OF , D=D V +D F D=DV+DF . This is achieved by setting the phase angle Arg(O F )−Arg(O) Arg(OF)−Arg(O) , which can be estimated by a hemodynamic model that we recently developed. We found this angle to be −72  deg −72  deg for the cardiac pulsation at 1 Hz, and −7  deg −7  deg for paced breathing at 0.1 Hz. Setting this angle, we can obtain the oxygen saturation of hemoglobin of the volume-oscillating vascular compartment, S V =|O V |/(|O V |+|D V |) SV=|OV|/(|OV|+|DV|) . We demonstrate this approach with cerebral near-infrared spectroscopy measurements on healthy volunteers at rest (n=4 n=4 ) and during 0.1 Hz paced breathing (n=3 n=3 ) with a 24-channel system. Rest data at the cardiac frequency were used to calculate the arterial saturation, S (a) S(a) ; over all subjects and channels, we found ⟨S V ⟩=⟨S (a) ⟩=0.96±0.02 ⟨SV⟩=⟨S(a)⟩=0.96±0.02 . In the case of paced breathing, we found ⟨S V ⟩=0.66±0.14 ⟨SV⟩=0.66±0.14 , which reflects venous-dominated hemodynamics at the respiratory frequency.

journal_name

J Biomed Opt

authors

Kainerstorfer JM,Sassaroli A,Fantini S

doi

10.1117/1.JBO.21.10.101408

subject

Has Abstract

pub_date

2016-10-01 00:00:00

pages

101408

issue

10

eissn

1083-3668

issn

1560-2281

pii

2499417

journal_volume

21

pub_type

杂志文章
  • Characterization of natural and irradiated nails by means of the depolarization metrics.

    abstract::Mueller polarimetry is applied to study the samples of nails: natural (or reference) and irradiated to 2 Gy ionizing radiation dose. We measure the whole Mueller matrices of the samples as a function of the scattering angle at a wavelength of 632.8 nm. We apply depolarization analysis to measured Mueller matrices by c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.7.071108

    authors: Savenkov S,Priezzhev A,Oberemok Y,Sholom S,Kolomiets I,Chunikhina K

    更新日期:2016-07-01 00:00:00

  • Effect of motion artifacts and their correction on near-infrared spectroscopy oscillation data: a study in healthy subjects and stroke patients.

    abstract::Functional near-infrared spectroscopy is prone to contamination by motion artifacts (MAs). Motion correction algorithms have previously been proposed and their respective performance compared for evoked rain activation studies. We study instead the effect of MAs on "oscillation" data which is at the basis of functiona...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.5.056011

    authors: Selb J,Yücel MA,Phillip D,Schytz HW,Iversen HK,Vangel M,Ashina M,Boas DA

    更新日期:2015-05-01 00:00:00

  • Mid-infrared laser measurements of aqueous glucose.

    abstract::Mid-IR semiconductor lasers of two wavelength bands, 5.4 and 9.6 microm, are applied to measure aqueous glucose concentration ranging from 0 to 500 mgdL with Intralipid emulsion (0 to 8%) added as a fat simulator. The absorption coefficient micro(a) is found linear with respect to glucose and Intralipid concentrations...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714283

    authors: Guo B,Wang Y,Wang Y,Le HQ

    更新日期:2007-03-01 00:00:00

  • In vivo label-free quantification of liver microcirculation using dual-modality microscopy.

    abstract::Microcirculation lesion is a common symptom of chronic liver diseases in the form of vasculature deformation and circulation alteration. In acute to chronic liver diseases such as biliary atresia, microcirculation lesion can have an early onset. Detection of microcirculation lesion is meaningful for studying the progr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.116006

    authors: Yan J,Kang Y,Xu S,Ong LL,Zhuo S,Bunte RM,Chen N,Asada HH,So PT,Wanless IR,Yu H

    更新日期:2014-01-01 00:00:00

  • Blind deconvolution estimation of fluorescence measurements through quadratic programming.

    abstract::Time-deconvolution of the instrument response from fluorescence lifetime imaging microscopy (FLIM) data is usually necessary for accurate fluorescence lifetime estimation. In many applications, however, the instrument response is not available. In such cases, a blind deconvolution approach is required. An iterative me...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.7.075010

    authors: Campos-Delgado DU,Gutierrez-Navarro O,Arce-Santana ER,Skala MC,Walsh AJ,Jo JA

    更新日期:2015-07-01 00:00:00

  • Changes in the redox state and endogenous fluorescence of in vivo human skin due to intrinsic and photo-aging, measured by multiphoton tomography with fluorescence lifetime imaging.

    abstract::Ultraviolet radiation from solar exposure is a key extrinsic factor responsible for premature skin aging (i.e., photo-aging). Recent advances using in vivo multiphoton tomography (MPT) demonstrate the efficacy of this approach to assess intrinsic and extrinsic skin aging as an alternative to existing invasive techniqu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.6.061217

    authors: Sanchez WY,Obispo C,Ryan E,Grice JE,Roberts MS

    更新日期:2013-06-01 00:00:00

  • Holographic laser Doppler imaging of pulsatile blood flow.

    abstract::We report on wide-field imaging of pulsatile motion induced by blood flow using heterodyne holographic interferometry on the thumb of a healthy volunteer, in real time. Optical Doppler images were measured with green laser light by a frequency-shifted Mach-Zehnder interferometer in off-axis configuration. The recorded...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.6.066006

    authors: Bencteux J,Pagnoux P,Kostas T,Bayat S,Atlan M

    更新日期:2015-06-01 00:00:00

  • Raman spectroscopy of in vivo cutaneous melanin.

    abstract::We successfully acquire the in vivo Raman spectrum of melanin from human skin using a rapid near-infrared (NIR) Raman spectrometer. The Raman signals of in vivo cutaneous melanin are similar to those observed from natural and synthetic eumelanins. The melanin Raman spectrum is dominated by two intense and broad peaks ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1805553

    authors: Huang Z,Lui H,Chen XK,Alajlan A,McLean DI,Zeng H

    更新日期:2004-11-01 00:00:00

  • Preliminary evaluation of optical glucose sensing in red cell concentrations using near-infrared diffuse-reflectance spectroscopy.

    abstract::Bacterial contamination of blood products is one of the most frequent infectious complications of transfusion. Since glucose levels in blood supplies decrease as bacteria proliferate, it should be possible to detect the presence of bacterial contamination by measuring the glucose concentrations in the blood components...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.1.017004

    authors: Suzuki Y,Maruo K,Zhang AW,Shimogaki K,Ogawa H,Hirayama F

    更新日期:2012-01-01 00:00:00

  • Analysis of the dispersion compensation of acousto-optic deflectors used for multiphoton imaging.

    abstract::The acousto-optic deflector (AOD) is highly preferred in laser scanning microscopy for its fast scanning ability and random-addressing capability. However, its application in two-photon microscopy is frustrated by the dispersion of the AOD, which results in beam distortion and pulse lengthening. We report the analysis...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714061

    authors: Zeng S,Lv X,Bi K,Zhan C,Li D,Chen WR,Xiong W,Jacques SL,Luo Q

    更新日期:2007-03-01 00:00:00

  • Optical coherence tomography today: speed, contrast, and multimodality.

    abstract::In the last 25 years, optical coherence tomography (OCT) has advanced to be one of the most innovative and most successful translational optical imaging techniques, achieving substantial economic impact as well as clinical acceptance. This is largely owing to the resolution improvements by a factor of 10 to the submic...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.19.7.071412

    authors: Drexler W,Liu M,Kumar A,Kamali T,Unterhuber A,Leitgeb RA

    更新日期:2014-01-01 00:00:00

  • Phase-subtraction cell-counting method for live mouse embryos beyond the eight-cell stage.

    abstract::Since 1978 in vitro fertilization (IVF) procedures have resulted in the birth of over 3 million babies. Yet in 2005, IVF procedures had a live birth rate of only 34%, with 32% of these births resulting in multiple pregnancies. These multiple pregnancies were directly attributed to the transfer of multiple embryos to i...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2937468

    authors: Warger WC 2nd,Newmark JA,Warner CM,DiMarzio CA

    更新日期:2008-05-01 00:00:00

  • Detection of Plasmodium falciparum-infected red blood cells by optical stretching.

    abstract::We present the application of a microfluidic optical cell stretcher to measure the elasticity of malaria-infected red blood cells. The measurements confirm an increase in host cell rigidity during the maturation of the parasite Plasmodium falciparum. The device combines the selectivity and sensitivity of single-cell e...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3458919

    authors: Mauritz JM,Tiffert T,Seear R,Lautenschläger F,Esposito A,Lew VL,Guck J,Kaminski CF

    更新日期:2010-05-01 00:00:00

  • Myocardial tissue oxygenation estimated with calibrated diffuse reflectance spectroscopy during coronary artery bypass grafting.

    abstract::We present a study using a method able to assess tissue oxygenation, taking into account the absorption and the level of scattering in myocardial tissue using a calibrated fiber optic probe. With this method, interindividual comparisons of oxygenation can be made despite varying tissue optical properties during corona...

    journal_title:Journal of biomedical optics

    pub_type: 临床试验,杂志文章

    doi:10.1117/1.2976433

    authors: Häggblad E,Lindbergh T,Karlsson MG,Casimir-Ahn H,Salerud EG,Strömberg T

    更新日期:2008-09-01 00:00:00

  • Study of molecule variations in renal tumor based on confocal micro-Raman spectroscopy.

    abstract::Confocal micro-Raman spectroscopy--a valuable analytical tool in biological and medical field of research-allows probing molecular vibrations of samples without external labels or extensive preparation. We employ confocal micro-Raman spectroscopy to characterize renal tumors and normal tissue. Results show that Raman ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.031103

    authors: Zhuang Z,Li N,Guo Z,Zhu M,Xiong K,Chen S

    更新日期:2013-03-01 00:00:00

  • Permeability of hyperosmotic agent in normal and atherosclerotic vascular tissues.

    abstract::Noninvasive cardiovascular imaging could lead to the early detection and timely treatment of complex atherosclerotic lesions responsible for major cardiovascular events. Recent investigations have suggested that optical coherence tomography (OCT) is an ideal diagnostic tool due to the high resolution this technology a...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2870153

    authors: Ghosn MG,Carbajal EF,Befrui NA,Tellez A,Granada JF,Larin KV

    更新日期:2008-01-01 00:00:00

  • Applications of compressive sensing in spatial frequency domain imaging.

    abstract:SIGNIFICANCE:Spatial frequency domain imaging (SFDI) is an imaging modality that projects spatially modulated light patterns to determine optical property maps for absorption and reduced scattering of biological tissue via a pixel-by-pixel data acquisition and analysis procedure. Compressive sensing (CS) is a signal pr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.11.112904

    authors: Mellors BOL,Bentley A,Spear AM,Howle CR,Dehghani H

    更新日期:2020-11-01 00:00:00

  • Optoacoustic diagnostic modality: from idea to clinical studies with highly compact laser diode-based systems.

    abstract::Optoacoustic (photoacoustic) diagnostic modality is a technique that combines high optical contrast and ultrasound spatial resolution. We proposed using the optoacoustic technique for a number of applications, including cancer detection, monitoring of thermotherapy (hyperthermia, coagulation, and freezing), monitoring...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.9.091512

    authors: Esenaliev RO

    更新日期:2017-09-01 00:00:00

  • Shining Future of Biomedical Optics

    abstract::Lihong V. Wang summarizes his tenure as Editor-in-Chief of the Journal of Biomedical Optics and introduces his successor, Brian Pogue, who will assume the role in January 2018. ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.10.100101

    authors: Wang V

    更新日期:2017-10-04 00:00:00

  • Properties of erythrocyte light refraction in diabetic patients.

    abstract::Since hyperglycaemia changes the erythrocyte cell membrane fluidity and impairs cell deformity, our goal was to characterize hemoglobin and red blood cell (RBC) light refractive property changes in diabetic patients. Microscopic investigation was carried out on intact and fixed RBCs. To determine the refractive index ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1463043

    authors: Mazarevica G,Freivalds T,Jurka A

    更新日期:2002-04-01 00:00:00

  • Fast and automatic imaging of immunoenzyme-stained neuronal circuits in the whole brain of Drosophila.

    abstract::Knowledge of neuronal wiring and morphogenesis in Drosophila is essential to understand brain function and dysfunction. The immunoenzyme method based on horseradish peroxidase/diaminobenzidine (HRP/DAB) provides high-contrast images to resolve details underlying neuronal architecture. However, the poor staining penetr...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.19.9.090506

    authors: Tian Q,Yuan J,Li Y,Jiang T,Gong H,Zhou W

    更新日期:2014-09-01 00:00:00

  • Study on application of optical clearing technique in skin diseases.

    abstract::So far, the study of the optical clearing is almost always about healthy tissue. However, the ultimate goal is to detect diseases for clinical application. Optical clearing on diseased skins is explored. The effect is evaluated by applying a combined liquid paraffin and glycerol mixed solution on several kinds of dise...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.11.115003

    authors: Shan H,Liang Y,Wang J,Li Y

    更新日期:2012-11-01 00:00:00

  • Early development of optical low-coherence reflectometry and some recent biomedical applications.

    abstract::This paper explains the term low-coherence interferometry, reviews the early development of optical low-coherence reflectometry, and shows some of the paths that led to the field of biomedical optics. This paper demonstrates that early technical developments in the telecommunications industry resulted in a myriad of t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429914

    authors: Masters BR

    更新日期:1999-04-01 00:00:00

  • Quantitative fluorescence imaging of protoporphyrin IX through determination of tissue optical properties in the spatial frequency domain.

    abstract::The ability to quantitatively determine tissue fluorescence is of interest for the purpose of better understanding the details of photodynamic therapy of skin cancer. In particular, we are interested in quantifying protoporphyrin IX (PpIX) in vivo. We present a method of correcting fluorescence for effects of native t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3665440

    authors: Saager RB,Cuccia DJ,Saggese S,Kelly KM,Durkin AJ

    更新日期:2011-12-01 00:00:00

  • Monitoring the reduced scattering coefficient of bone tissues on the trajectory of pedicle screw placement using near-infrared spectroscopy.

    abstract::Pedicle screw (PS) fixation has been widely used for spine diseases. Scientists and clinicians employ several approaches to navigate PS during operation. We have demonstrated the feasibility of monitoring the reduced scattering coefficient (μ's) on the trajectory of PS using near-infrared spectroscopy (NIRS). To perfo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.117002

    authors: Liu Y,Wang Y,Qian Z,Zhao J,Cao X,Li W

    更新日期:2014-01-01 00:00:00

  • Fiber optic biosensor for the detection of C-reactive protein and the study of protein binding kinetics.

    abstract::Application of a fiber optic biosensor (FOB) to the real-time investigation of the interaction kinetics between FITC-conjugated monoclonal sheep anti-human C-reactive protein (CRP) antibody and CRP isoforms on the surface of optical fiber is described. Recently, both the native pentameric CRP (pCRP), an acute phase pr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714029

    authors: Chou C,Hsu HY,Wu HT,Tseng KY,Chiou A,Yu CJ,Lee ZY,Chan TS

    更新日期:2007-03-01 00:00:00

  • Reflectance confocal microscopy for characterization of mammary ductal structures and development of neoplasia in genetically engineered mouse models of breast cancer.

    abstract::The earliest steps of breast cancer begin with aberrations in mammary ductal structure. Techniques that enable an investigator to image in situ and then analyze the same tissue using biochemical tools facilitates identification of genetic networks and signaling pathways active in the imaged structure. Cellular confoca...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2065827

    authors: Parrish A,Halama E,Tilli MT,Freedman M,Furth PA

    更新日期:2005-09-01 00:00:00

  • Innovative Troxler-free measurement of macular pigment and lens density with correction of the former for the aging lens.

    abstract::Simplified measurement of macular pigment optical density (MPOD) is important because of the ocular health benefits that are attributed to these retinal carotenoids. Here, we describe a novel instrument designed for this purpose, based on heterochromatic flicker photometry (HFP), which removes a number of difficulties...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.10.107003

    authors: Bone RA,Mukherjee A

    更新日期:2013-10-01 00:00:00

  • High-speed 1310 nm-band spectral domain optical coherence tomography at 184,000 lines per second.

    abstract::We propose a useful method to boost the imaging speed for spectral domain optical coherence tomography (SDOCT) by multiplying a number of high-speed spectrometers used in the system with selective precise control of data-recording and data-reading phases for spectral cameras employed in each spectrometer. To demonstra...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3592492

    authors: An L,Guan G,Wang RK

    更新日期:2011-06-01 00:00:00

  • Discovery of the near-infrared window into the body and the early development of near-infrared spectroscopy.

    abstract::Extension of optical monitoring of intact tissues from the visible and ultraviolet to the near-infrared (NIR) range (700-1300 nm) was first undertaken in 1977 for the purpose of monitoring the redox behavior of Cytochrome c oxidase (cyt c ox) in vivo. Soon it became evident that the much greater NIR translucency of sk...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429952

    authors: Jo Bsis-Vandervliet FF

    更新日期:1999-10-01 00:00:00