High-speed 1310 nm-band spectral domain optical coherence tomography at 184,000 lines per second.

Abstract:

:We propose a useful method to boost the imaging speed for spectral domain optical coherence tomography (SDOCT) by multiplying a number of high-speed spectrometers used in the system with selective precise control of data-recording and data-reading phases for spectral cameras employed in each spectrometer. To demonstrate the proposed method, we use two spectrometers built in a 1310 nm-band SDOCT system, each equipped with a high-speed InGaAs line-scan camera capable of 92-kHz line-scan rate, to achieve an unprecedented imaging speed at 184,000 lines/s. We validate the multiplied imaging speed by measuring Doppler-induced phase shift in the spectrograms using a flow phantom.

journal_name

J Biomed Opt

authors

An L,Guan G,Wang RK

doi

10.1117/1.3592492

subject

Has Abstract

pub_date

2011-06-01 00:00:00

pages

060506

issue

6

eissn

1083-3668

issn

1560-2281

journal_volume

16

pub_type

信件
  • Three-dimensional optical coherence tomography at 1050 nm versus 800 nm in retinal pathologies: enhanced performance and choroidal penetration in cataract patients.

    abstract::Frequency domain optical coherence tomography (FD-OCT), based on an all-reflective high-speed InGaAs spectrometer, operating in the 1050 nm wavelength region for retinal diagnostics, enables high-speed, volumetric imaging of retinal pathologies with greater penetration into choroidal tissue is compared to conventional...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2773728

    authors: Povazay B,Hermann B,Unterhuber A,Hofer B,Sattmann H,Zeiler F,Morgan JE,Falkner-Radler C,Glittenberg C,Blinder S,Drexler W

    更新日期:2007-07-01 00:00:00

  • Quantitative imaging of protein-protein interactions by multiphoton fluorescence lifetime imaging microscopy using a streak camera.

    abstract::Fluorescence lifetime imaging microscopy (FLIM) using multiphoton excitation techniques is now finding an important place in quantitative imaging of protein-protein interactions and intracellular physiology. Recent developments in multiphoton FLIM methods are reviewed and a novel multiphoton FLIM system using a streak...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1577574

    authors: Krishnan RV,Masuda A,Centonze VE,Herman B

    更新日期:2003-07-01 00:00:00

  • Chemical reactivation of fluorescein isothiocyanate immunofluorescence-labeled resin-embedded samples.

    abstract::Resin embedding is widely used and facilitates microscopic imaging of biological tissues. In contrast, quenching of fluorescence during embedding process hinders the application of resin embedding for imaging of fluorescence-labeled samples. For samples expressing fluorescent proteins, it has been demonstrated that th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.2.020501

    authors: Li L,Rao G,Lv X,Chen R,Cheng X,Wang X,Zeng S,Liu X

    更新日期:2018-02-01 00:00:00

  • Waveguide evanescent field fluorescence microscopy: high contrast imaging of a domain forming mixed lipid Langmuir-Blodgett monolayer mimicking lung surfactant.

    abstract::Waveguide evanescent field fluorescence (WEFF) microscopy is a new development that allows the imaging of contact regions between biological cells and their substratum, as well as imaging of ultrathin films such as monomolecular Langmuir-Blodgett (LB) films. Mixed-lipid monolayer systems mimicking lung surfactant were...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3569095

    authors: Hassanzadeh A,Mittler S

    更新日期:2011-04-01 00:00:00

  • Calibration of diffuse correlation spectroscopy blood flow index with venous-occlusion diffuse optical spectroscopy in skeletal muscle.

    abstract::We investigate and assess the utility of a simple scheme for continuous absolute blood flow monitoring based on diffuse correlation spectroscopy (DCS). The scheme calibrates DCS using venous-occlusion diffuse optical spectroscopy (VO-DOS) measurements of arm muscle tissue at a single time-point. A calibration coeffici...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.12.125005

    authors: Li Z,Baker WB,Parthasarathy AB,Ko TS,Wang D,Schenkel S,Durduran T,Li G,Yodh AG

    更新日期:2015-01-01 00:00:00

  • In vitro detection and quantification of enamel and root caries using infrared photothermal radiometry and modulated luminescence.

    abstract::Artificially created demineralized and remineralized carious lesions on the root and enamel of human teeth were examined by photothermal radiometry (PTR) and modulated luminescence (LUM). Fourteen extracted human teeth were used and a lesion was created on a 1 mmx4 mm rectangular window, spanning root to enamel, using...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2942374

    authors: Jeon RJ,Hellen A,Matvienko A,Mandelis A,Abrams SH,Amaechi BT

    更新日期:2008-05-01 00:00:00

  • Myocardial tissue oxygenation estimated with calibrated diffuse reflectance spectroscopy during coronary artery bypass grafting.

    abstract::We present a study using a method able to assess tissue oxygenation, taking into account the absorption and the level of scattering in myocardial tissue using a calibrated fiber optic probe. With this method, interindividual comparisons of oxygenation can be made despite varying tissue optical properties during corona...

    journal_title:Journal of biomedical optics

    pub_type: 临床试验,杂志文章

    doi:10.1117/1.2976433

    authors: Häggblad E,Lindbergh T,Karlsson MG,Casimir-Ahn H,Salerud EG,Strömberg T

    更新日期:2008-09-01 00:00:00

  • Transmissive liquid-crystal device for correcting primary coma aberration and astigmatism in biospecimen in two-photon excitation laser scanning microscopy.

    abstract::All aberrations produced inside a biospecimen can degrade the quality of a three-dimensional image in two-photon excitation laser scanning microscopy. Previously, we developed a transmissive liquid-crystal device to correct spherical aberrations that improved the image quality of a fixed-mouse-brain slice treated with...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.121503

    authors: Tanabe A,Hibi T,Ipponjima S,Matsumoto K,Yokoyama M,Kurihara M,Hashimoto N,Nemoto T

    更新日期:2016-12-01 00:00:00

  • Investigation of nuclear nano-morphology marker as a biomarker for cancer risk assessment using a mouse model.

    abstract::The development of accurate and clinically applicable tools to assess cancer risk is essential to define candidates to undergo screening for early-stage cancers at a curable stage or provide a novel method to monitor chemoprevention treatments. With the use of our recently developed optical technology--spatial-domain ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.6.066014

    authors: Bista RK,Uttam S,Hartman DJ,Qiu W,Yu J,Zhang L,Brand RE,Liu Y

    更新日期:2012-06-01 00:00:00

  • Early detection of colorectal cancer relapse by infrared spectroscopy in "normal" anastomosis tissue.

    abstract::Colorectal cancer is one of the most aggressive cancers usually occurring in people above the age of 50 years. In the United States, colorectal cancer is the third most diagnosed cancer. The American Cancer Society has estimated 96,830 new cases of colon cancer and 40,000 new cases of rectal cancer in 2014 in the Unit...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.7.075007

    authors: Salman A,Sebbag G,Argov S,Mordechai S,Sahu RK

    更新日期:2015-07-01 00:00:00

  • Scattering coefficient determination in turbid media with backscattered polarized light.

    abstract::A simple empirical method is presented to determine the scattering coefficient mu' s from backscattered polarized images of turbid media. It uses the ratio, pixel by pixel, of two images that are the second and the first backscattered Stokes parameter images Q and I, respectively. Taking this image ratio, then integra...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1924715

    authors: Jaillon F,Saint-Jalmes H

    更新日期:2005-05-01 00:00:00

  • Cutaneous melanin exhibiting fluorescence emission under near-infrared light excitation.

    abstract::Under ultraviolet and visible light excitation, melanin is essentially a nonfluorescent substance. This work reports our study on near-infrared (NIR) fluorescence properties of melanins, and explores potential applications of NIR fluorescence techniques for evaluating skin disorders involving melanin. The NIR fluoresc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2204007

    authors: Huang Z,Zeng H,Hamzavi I,Alajlan A,Tan E,McLean DI,Lui H

    更新日期:2006-05-01 00:00:00

  • Optical coherence elastography for evaluating customized riboflavin/UV-A corneal collagen crosslinking.

    abstract::UV-induced collagen cross-linking is a promising treatment for keratoconus that stiffens corneal tissue and prevents further degeneration. Since keratoconus is generally localized, the efficacy of collagen cross-linking (CXL) treatments could be improved by stiffening only the weakened parts of the cornea. Here, we de...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.9.091504

    authors: Singh M,Li J,Vantipalli S,Han Z,Larin KV,Twa MD

    更新日期:2017-09-01 00:00:00

  • Rise of Raman spectroscopy in neurosurgery: a review.

    abstract:SIGNIFICANCE:Although the clinical potential for Raman spectroscopy (RS) has been anticipated for decades, it has only recently been used in neurosurgery. Still, few devices have succeeded in making their way into the operating room. With recent technological advancements, however, vibrational sensing is poised to be a...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.5.050901

    authors: DePaoli D,Lemoine É,Ember K,Parent M,Prud'homme M,Cantin L,Petrecca K,Leblond F,Côté DC

    更新日期:2020-05-01 00:00:00

  • Enhancement factor in low-coherence enhanced backscattering and its applications for characterizing experimental skin carcinogenesis.

    abstract::We experimentally study potential mechanisms by which the enhancement factor in low-coherence enhanced backscattering (LEBS) can probe subtle variations in radial intensity distribution in weakly scattering media. We use enhanced backscattering of light by implementing either (1) low spatial coherence illumination or ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3443795

    authors: Liu J,Xu Z,Song Q,Konger RL,Kim YL

    更新日期:2010-05-01 00:00:00

  • Resolution in the ApoTome and the confocal laser scanning microscope: comparison.

    abstract::The essential feature of the confocal laser scanning microscope (cLSM) is the generation of optical sections by the removal of out-of-focus light. About ten years ago, structured illumination microscopy (SIM) was introduced as an alternative method for obtaining optical sections from biological specimens. Here we comp...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3083439

    authors: Weigel A,Schild D,Zeug A

    更新日期:2009-01-01 00:00:00

  • Spatial distribution of vastus lateralis blood flow and oxyhemoglobin saturation measured at the end of isometric quadriceps contraction by multichannel near-infrared spectroscopy.

    abstract::Muscle blood flow (MBF) and muscle oxygen saturation (SmO(2)) were measured at eight locations (four proximal, four distal) over a 4 x 8 cm(2) area of the vastus lateralis at rest and immediately after isometric, maximal quadriceps contraction using multichannel, frequency-domain, near-infrared spectroscopy. A venous ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1646417

    authors: Quaresima V,Ferrari M,Franceschini MA,Hoimes ML,Fantini S

    更新日期:2004-03-01 00:00:00

  • High-magnification vascular imaging to reject false-positive sites in situ during Hexvix® fluorescence cystoscopy.

    abstract::Fluorescence imaging for detection of non-muscle-invasive bladder cancer is based on the selective production and accumulation of fluorescing porphyrins-mainly, protoporphyrin IX-in cancerous tissues after the instillation of Hexvix®. Although the sensitivity of this procedure is very good, its specificity is somewhat...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3484257

    authors: Lovisa B,Jichlinski P,Weber BC,Aymon D,van den Bergh H,Wagnières G

    更新日期:2010-09-01 00:00:00

  • Quantitative tool for rapid disease mapping using optical coherence tomography images of azoxymethane-treated mouse colon.

    abstract::Optical coherence tomography (OCT) can provide new insight into disease progression and therapy by enabling nondestructive, serial imaging of in vivo cancer models. In previous studies, we have shown the utility of endoscopic OCT for identifying adenomas in the azoxymethane-treated mouse model of colorectal cancer and...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3446674

    authors: Winkler AM,Rice PF,Drezek RA,Barton JK

    更新日期:2010-07-01 00:00:00

  • Laser scoop desobliteration: a method for minimally invasive remote recanalization of chronically occluded superficial femoral arteries.

    abstract::Stenosis and occlusion of the superficial femoral artery (SFA) are most common in arterial occlusive disease. There are numerous interventional, surgical, and combined approaches to reconstitute maximum blood supply to the lower limb; however, despite intense clinical research, the long-term success rates are still po...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.2.025005

    authors: Heneweer C,Siggelkow M,Helle M,Petzina R,Wulff A,Schaefer JP,Berndt R,Rusch R,Wedel T,Klaws G,Müller-Gerbl M,Röcken C,Jansen O,Lutter G,Cremer J,Groß J

    更新日期:2015-02-01 00:00:00

  • Multiplexed fluorescence mediated tomography with temporal and spectral data.

    abstract::We recently developed an algorithm for multiplexed fluorescence tomographic imaging of at least four fluorophores concurrently in the red and near-infrared wavelength region by jointly using spectral and temporal data. We report the design of a fluorescence tomography instrument that acquires spectral and temporal dat...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.10.105001

    authors: Mu Y,Pera V,Niedre M

    更新日期:2016-10-01 00:00:00

  • Change of tumor vascular reactivity during tumor growth and postchemotherapy observed by near-infrared spectroscopy.

    abstract::Breast cancer is one of the most common cancers in females. To monitor chemotherapeutic efficacy for breast cancer, medical imaging systems such as x-ray mammography, computed tomography, magnetic resonance imaging, and ultrasound imaging have been used. Currently, it can take up to 3 to 6 weeks to see the tumor respo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.12.121603

    authors: Lee S,Jeong H,Seong M,Kim JG

    更新日期:2017-12-01 00:00:00

  • Photodynamic therapy-induced nitric oxide production in neuronal and glial cells.

    abstract::Nitric oxide (NO) has been recently demonstrated to enhance apoptosis of glial cells induced by photodynamic therapy (PDT), but to protect glial cells from PDT-induced necrosis in the crayfish stretch receptor, a simple neuroglial preparation that consists of a single mechanosensory neuron enveloped by satellite glial...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.10.105005

    authors: Kovaleva VD,Uzdensky AB

    更新日期:2016-10-01 00:00:00

  • Optimal probe design for breast imaging using near-infrared diffused light.

    abstract::Shallow lesions less than 1.5-cm deep are frequently seen in breast patients when they are scanned in reflection geometry. Two boundary conditions are compared for imaging shallow lesions, and a new probe design is introduced. A partial reflection boundary condition is suitable for imaging shallow lesions less than 1....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2966703

    authors: Xu C,Yuan B,Zhu Q

    更新日期:2008-07-01 00:00:00

  • Determination of optical scattering properties in turbid media using Mueller matrix imaging.

    abstract::A need exists for the continued development of diagnostic tools and methods capable of distinguishing and characterizing slight differences in the optical properties of tissues. We present a method to estimate the scattering coefficient contribution as a function of particle size in complex mixtures of polystyrene sph...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2363347

    authors: Cameron BD,Li Y,Nezhuvingal A

    更新日期:2006-09-01 00:00:00

  • Modeling of the temporal effects of heating during infrared neural stimulation.

    abstract::A model of infrared neural stimulation (INS) has been developed to allow the temporal characteristics of different stimulation parameters and geometries to be better understood. The model uses a finite element approach to solve the heat equation and allow detailed analysis of heat during INS with both microsecond and ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.035004

    authors: Thompson AC,Wade SA,Cadusch PJ,Brown WG,Stoddart PR

    更新日期:2013-03-01 00:00:00

  • Unsupervised analysis of small animal dynamic Cerenkov luminescence imaging.

    abstract::Clustering analysis (CA) and principal component analysis (PCA) were applied to dynamic Cerenkov luminescence images (dCLI). In order to investigate the performances of the proposed approaches, two distinct dynamic data sets obtained by injecting mice with (32)P-ATP and (18)F-FDG were acquired using the IVIS 200 optic...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3663442

    authors: Spinelli AE,Boschi F

    更新日期:2011-12-01 00:00:00

  • In vivo photoacoustic imaging of blood vessels using a homodyne interferometer with zero-crossing triggering.

    abstract::We demonstrate a quasinoncontact photoacoustic imaging method using a homodyne interferometer with a long coherence length laser. The generated photoacoustic signal is detected by a system that is locked at its maximum sensitivity through the use of balanced detection and zero-crossing triggering. The balanced detecto...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.3.036002

    authors: Lu J,Gao Y,Ma Z,Zhou H,Wang RK,Wang Y

    更新日期:2017-03-01 00:00:00

  • Simulating the scanning of a focused beam through scattering media using a numerical solution of Maxwell's equations.

    abstract::A highly efficient method based on Maxwell's theory was developed, which enables the calculation of the scanning of a focused beam through scattering media. Maxwell's equations were numerically solved in two dimensions using finite difference time domain simulations. The modeling of the focused beam was achieved by ap...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.7.071404

    authors: Elmaklizi A,Schäfer J,Kienle A

    更新日期:2014-07-01 00:00:00

  • Interstitial Doppler optical coherence tomography monitors microvascular changes during photodynamic therapy in a Dunning prostate model under varying treatment conditions.

    abstract::We measure the tumor vascular response to varying irradiance rates during photodynamic therapy (PDT) in a Dunning rat prostate model with interstitial Doppler optical coherence tomography (IS-DOCT). Rats are given a photosensitizer drug, Photofrin, and the tumors are exposed to light (635 nm) with irradiance rates ran...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2744068

    authors: Standish BA,Jin X,Smolen J,Mariampillai A,Munce NR,Wilson BC,Vitkin IA,Yang VX

    更新日期:2007-05-01 00:00:00