Spatial distribution of vastus lateralis blood flow and oxyhemoglobin saturation measured at the end of isometric quadriceps contraction by multichannel near-infrared spectroscopy.

Abstract:

:Muscle blood flow (MBF) and muscle oxygen saturation (SmO(2)) were measured at eight locations (four proximal, four distal) over a 4 x 8 cm(2) area of the vastus lateralis at rest and immediately after isometric, maximal quadriceps contraction using multichannel, frequency-domain, near-infrared spectroscopy. A venous occlusion was applied 20 s before the end of the exercise, so that the venous-occlusion-induced increase in total hemoglobin was recorded without any delay after the end of the exercise. Therefore, we were able to investigate the relationship between the exercise-induced changes in vastus lateralis MBF and SmO(2). After exercise, MBF increased significantly at each measured location. Comparing the MBF values measured at the end of exercise in the proximal and distal regions, we observed that only one proximal region had a significantly higher MBF than the corresponding distal one. The maximum desaturation measured during exercise was positively correlated with the postexercise to pre-exercise MBF ratio in both the proximal (P=0.016) and distal (P=0.0065) regions. These data confirm that frequency-domain tissue oximeters are noninvasive, powerful tools to investigate the spatial and temporal features of muscle blood flow and oxygenation, with potential applications in areas of pathophysiology.

journal_name

J Biomed Opt

authors

Quaresima V,Ferrari M,Franceschini MA,Hoimes ML,Fantini S

doi

10.1117/1.1646417

subject

Has Abstract

pub_date

2004-03-01 00:00:00

pages

413-20

issue

2

eissn

1083-3668

issn

1560-2281

journal_volume

9

pub_type

杂志文章
  • Multispectral in vivo three-dimensional optical coherence tomography of human skin.

    abstract::The capability of optical coherence tomography (OCT) to perform "optical biopsy" of tissues within a depth range of 1 to 2 mm with micron-scale resolution in real time makes it a promising biomedical imaging modality for dermatologic applications. Three high-speed, spectrometer-based frequency-domain OCT systems opera...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3400665

    authors: Alex A,Povazay B,Hofer B,Popov S,Glittenberg C,Binder S,Drexler W

    更新日期:2010-03-01 00:00:00

  • Noninvasive measurement of glucose concentration on human fingertip by optical coherence tomography.

    abstract::A method is proposed for determining the glucose concentration on the human fingertip by extracting two optical parameters, namely the optical rotation angle and the depolarization index, using a Mueller optical coherence tomography technique and a genetic algorithm. The feasibility of the proposed method is demonstra...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.4.047001

    authors: Chen TL,Lo YL,Liao CC,Phan QH

    更新日期:2018-04-01 00:00:00

  • Modulation of an optical needle's reflectivity alters the average photon path through scattering media.

    abstract::We introduce the concept of deliberate placement of absorbers to alter the average path of photons through tissue for a biomedical optical device. By changing the reflectivity of a needle that separates a source and detector, the average photon path through a turbid medium can be changed. Totally reflective needles ha...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2168167

    authors: Simonson P,D'Amico E,Gratton E

    更新日期:2006-01-01 00:00:00

  • Design and validation of an angle-resolved low-coherence interferometry fiber probe for in vivo clinical measurements of depth-resolved nuclear morphology.

    abstract::We present a novel Fourier-domain angle-resolved low-coherence interferometry (a /LCI) fiber probe designed for in vivo clinical application in gastrointestinal endoscopy. The a/LCI technique measures the depth-resolved angular scattering distribution to determine the size distribution and optical density of cell nucl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3520130

    authors: Zhu Y,Terry NG,Woosley JT,Shaheen NJ,Wax A

    更新日期:2011-01-01 00:00:00

  • Measurement of drug and macromolecule diffusion across atherosclerotic rabbit aorta ex vivo by attenuated total reflection-Fourier transform infrared imaging.

    abstract::Diffusion of two model drugs-benzyl nicotinate and ibuprofen-and the plasma macromolecule albumin across atherosclerotic rabbit aorta was studied ex vivo by attenuated total reflection-Fourier transform infrared (ATR-FTIR) imaging. Solutions of these molecules were applied to the endothelial surface of histological se...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3174395

    authors: Palombo F,Danoux CB,Weinberg PD,Kazarian SG

    更新日期:2009-07-01 00:00:00

  • Use of picosecond Kerr-gated Raman spectroscopy to suppress signals from both surface and deep layers in bladder and prostate tissue.

    abstract::Raman spectroscopy is an optical technique able to interrogate biological tissues, giving us an understanding of the changes in molecular structure that are associated with disease development. The Kerr-gated Raman spectroscopy technique uses a picosecond pulsed laser as well as fast temporal gating of collected Raman...

    journal_title:Journal of biomedical optics

    pub_type: 临床试验,杂志文章

    doi:10.1117/1.1991848

    authors: Prieto MC,Matousek P,Towrie M,Parker AW,Wright M,Ritchie AW,Stone N

    更新日期:2005-07-01 00:00:00

  • Anatomical image-guided fluorescence molecular tomography reconstruction using kernel method.

    abstract::Fluorescence molecular tomography (FMT) is an important in vivo imaging modality to visualize physiological and pathological processes in small animals. However, FMT reconstruction is ill-posed and ill-conditioned due to strong optical scattering in deep tissues, which results in poor spatial resolution. It is well kn...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.5.055001

    authors: Baikejiang R,Zhao Y,Fite BZ,Ferrara KW,Li C

    更新日期:2017-05-01 00:00:00

  • Multiphoton adaptation of a commercial low-cost confocal microscope for live tissue imaging.

    abstract::The Nikon C1 confocal laser scanning microscope is a relatively inexpensive and user-friendly instrument. We describe a straightforward method to convert the C1 for multiphoton microscopy utilizing direct coupling of a femtosecond near-infrared laser into the scan head and fiber optic transmission of emission light to...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3139850

    authors: Mancuso JJ,Larson AM,Wensel TG,Saggau P

    更新日期:2009-05-01 00:00:00

  • Fundamental Studies of Fiber-Guided Soft Tissue Cutting by Means of Pulsed Midinfrared Lasers and their Application in Ureterotomy.

    abstract::Fiber-guided ablation of soft tissue with pulsed holmium and thulium lasers was investigated for intraluminal incisions. A bare fiber/tissue-contact application system with a nearly tangential irradiation geometry was first used in vitro on porcine ureter tissue. The efficiency and precision of the method was analyzed...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429865

    authors: Brinkmann R,Knipper A,Dro Ge G,Schro Er F,Gromoll B,Birngruber R

    更新日期:1998-01-01 00:00:00

  • Analysis of human nails by laser-induced breakdown spectroscopy.

    abstract::Laser-induced breakdown spectroscopy (LIBS) is applied to analyze human fingernails using nanosecond laser pulses. Measurements on 45 nail samples are carried out and 14 key species are identified. The elements detected with the present system are: Al, C, Ca, Fe, H, K, Mg, N, Na, O, Si, Sr, Ti as well as CN molecule. ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3574757

    authors: Hosseinimakarem Z,Tavassoli SH

    更新日期:2011-05-01 00:00:00

  • Myocardial tissue oxygenation estimated with calibrated diffuse reflectance spectroscopy during coronary artery bypass grafting.

    abstract::We present a study using a method able to assess tissue oxygenation, taking into account the absorption and the level of scattering in myocardial tissue using a calibrated fiber optic probe. With this method, interindividual comparisons of oxygenation can be made despite varying tissue optical properties during corona...

    journal_title:Journal of biomedical optics

    pub_type: 临床试验,杂志文章

    doi:10.1117/1.2976433

    authors: Häggblad E,Lindbergh T,Karlsson MG,Casimir-Ahn H,Salerud EG,Strömberg T

    更新日期:2008-09-01 00:00:00

  • Visible-wavelength two-photon excitation microscopy with multifocus scanning for volumetric live-cell imaging.

    abstract::Two-photon excitation microscopy is one of the key techniques used to observe three-dimensional (3-D) structures in biological samples. We utilized a visible-wavelength laser beam for two-photon excitation in a multifocus confocal scanning system to improve the spatial resolution and image contrast in 3-D live-cell im...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.1.014502

    authors: Oketani R,Suda H,Uegaki K,Kubo T,Matsuda T,Yamanaka M,Arai Y,Smith N,Nagai T,Fujita K

    更新日期:2019-11-01 00:00:00

  • System analysis of spatial frequency domain imaging for quantitative mapping of surgically resected breast tissues.

    abstract::The feasibility of spatial frequency domain imaging (SFDI) for breast surgical margin assessment was evaluated in tissue-simulating phantoms and in fully intact lumpectomy specimens at the time of surgery. Phantom data was evaluated according to contrast-detail resolution, quantitative accuracy and model-data goodness...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.036012

    authors: Laughney AM,Krishnaswamy V,Rice TB,Cuccia DJ,Barth RJ,Tromberg BJ,Paulsen KD,Pogue BW,Wells WA

    更新日期:2013-03-01 00:00:00

  • Surgical lighting with contrast enhancement based on spectral reflectance comparison and entropy analysis.

    abstract::Surgical light is important for helping the surgeon easily identify specific tissues during an operation. We propose a spectral reflectance comparison model to optimize the light-emitting diode light spectrum in the operating room. An entropy evaluation method, meant specifically for surgical situations, was developed...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.10.105012

    authors: Shen J,Wang H,Wu Y,Li A,Chen C,Zheng Z

    更新日期:2015-10-01 00:00:00

  • Study of cadmium-induced cytotoxicity using two-photon excitation endogenous fluorescence microscopy.

    abstract::We demonstrate that using time-resolved two-photon excitation endogenous fluorescence microscopy, the cadmium (Cd)-induced cellular toxic level can be assessed by the free-to protein-bound reduced nicotinamide adenine dinucleotide (free/bound NADH) ratio in a living cell. NADH fluorescence excited at 730 nm is capture...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3250293

    authors: Li D,Yang MS,Lin T,Zheng W,Qu JY

    更新日期:2009-09-01 00:00:00

  • Comparison of cerebral oxygen saturation in premature infants by near-infrared spatially resolved spectroscopy: observations on probe-dependent bias.

    abstract::Spatially resolved spectroscopy (SRS) allows the estimation of absolute tissue oxygen saturation, the ratio of oxygenated to total hemoglobin concentration, which may facilitate the comparison of results among patients. Eighty-two premature infants were included over two years. The cerebral tissue oxygenation index (c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3013454

    authors: Sorensen LC,Leung TS,Greisen G

    更新日期:2008-11-01 00:00:00

  • Early diagnosis of teeth erosion using polarized laser speckle imaging.

    abstract::Dental erosion starts with a chemical attack on dental tissue causing tooth demineralization, altering the tooth structure and making it more sensitive to mechanical erosion. Medical diagnosis of dental erosion is commonly achieved through a visual inspection by the dentist during dental checkups and is therefore high...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.7.071103

    authors: Abou Nader C,Pellen F,Loutfi H,Mansour R,Le Jeune B,Le Brun G,Abboud M

    更新日期:2016-07-01 00:00:00

  • High-magnification vascular imaging to reject false-positive sites in situ during Hexvix® fluorescence cystoscopy.

    abstract::Fluorescence imaging for detection of non-muscle-invasive bladder cancer is based on the selective production and accumulation of fluorescing porphyrins-mainly, protoporphyrin IX-in cancerous tissues after the instillation of Hexvix®. Although the sensitivity of this procedure is very good, its specificity is somewhat...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3484257

    authors: Lovisa B,Jichlinski P,Weber BC,Aymon D,van den Bergh H,Wagnières G

    更新日期:2010-09-01 00:00:00

  • Effect of noise on modulation amplitude and phase in frequency-domain diffusive imaging.

    abstract::We theoretically investigate the effect of noise on frequency-domain heterodyne and/or homodyne measurements of intensity-modulated beams propagating through diffusive media, such as a photon density wave. We assumed that the attenuated amplitude and delayed phase are estimated by taking the Fourier transform of the n...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.1.016010

    authors: Kang D,Kupinski MA

    更新日期:2012-01-01 00:00:00

  • Macromolecular diffusion in the extracellular matrix measured by fluorescence correlation spectroscopy.

    abstract::Diffusion of therapeutic macromolecules through the extracellular matrix of tumor tissue is a crucial step in drug delivery. We use fluorescence correlation spectroscopy (FCS) to measure diffusion of IgG (150 kDa) and dextrans (155 kDa and 2 MDa) in solution, 5% gelatin hydrogel, and multicellular spheroids. Gel and s...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2982530

    authors: Reitan NK,Juthajan A,Lindmo T,de Lange Davies C

    更新日期:2008-09-01 00:00:00

  • Spatially resolved optical and ultrastructural properties of colorectal and pancreatic field carcinogenesis observed by inverse spectroscopic optical coherence tomography.

    abstract::Field carcinogenesis is the initial stage of cancer progression. Understanding field carcinogenesis is valuable for both cancer biology and clinical medicine. Here, we used inverse spectroscopic optical coherence tomography to study colorectal cancer (CRC) and pancreatic cancer (PC) field carcinogenesis. Depth-resolve...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.3.036013

    authors: Yi J,Radosevich AJ,Stypula-Cyrus Y,Mutyal NN,Azarin SM,Horcher E,Goldberg MJ,Bianchi LK,Bajaj S,Roy HK,Backman V

    更新日期:2014-03-01 00:00:00

  • Spherical aberration correction in multiphoton fluorescence imaging using objective correction collar.

    abstract::Multiphoton microscopy has evolved into a powerful bioimaging tool in three dimensions. However, the ability to image biological specimens in-depth can be hindered by sample spherical aberration and scattering. These two phenomena can result in the degradation of image resolution and the loss of detected multiphoton s...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1924614

    authors: Lo W,Sun Y,Lin SJ,Jee SH,Dong CY

    更新日期:2005-05-01 00:00:00

  • Photoacoustic microscopy of blood pulse wave.

    abstract::Blood pulse wave velocity (PWV) is an important physiological parameter that characterizes vascular stiffness. In this letter, we present electrocardiogram-synchronized, photoacoustic microscopy for noninvasive quantification of the PWV in the peripheral vessels of living mice. Interestingly, blood pulse wave-induced ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.070504

    authors: Yeh C,Hu S,Maslov K,Wang LV

    更新日期:2012-07-01 00:00:00

  • Analyzing reflectance spectra of human skin in legal medicine.

    abstract::Our current research in the framework of an interdisciplinary project focuses on modelling the dynamics of the hemoglobin reoxygenation process in post-mortem human skin by reflectance spectrometry. The observations of reoxygenation of hemoglobin in livores after postmortem exposure to a cold environment relate the re...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.1.017004

    authors: Belenki L,Sterzik V,Schulz K,Bohnert M

    更新日期:2013-01-01 00:00:00

  • Mid-infrared laser measurements of aqueous glucose.

    abstract::Mid-IR semiconductor lasers of two wavelength bands, 5.4 and 9.6 microm, are applied to measure aqueous glucose concentration ranging from 0 to 500 mgdL with Intralipid emulsion (0 to 8%) added as a fat simulator. The absorption coefficient micro(a) is found linear with respect to glucose and Intralipid concentrations...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714283

    authors: Guo B,Wang Y,Wang Y,Le HQ

    更新日期:2007-03-01 00:00:00

  • Performance of a lookup table-based approach for measuring tissue optical properties with diffuse optical spectroscopy.

    abstract::Diffuse optical spectroscopy (DOS) provides a powerful tool for fast and noninvasive disease diagnosis. The ability to leverage DOS to accurately quantify tissue optical parameters hinges on the model used to estimate light-tissue interaction. We describe the accuracy of a lookup table (LUT)-based inverse model for me...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.5.057001

    authors: Nichols BS,Rajaram N,Tunnell JW

    更新日期:2012-05-01 00:00:00

  • Simulating the scanning of a focused beam through scattering media using a numerical solution of Maxwell's equations.

    abstract::A highly efficient method based on Maxwell's theory was developed, which enables the calculation of the scanning of a focused beam through scattering media. Maxwell's equations were numerically solved in two dimensions using finite difference time domain simulations. The modeling of the focused beam was achieved by ap...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.7.071404

    authors: Elmaklizi A,Schäfer J,Kienle A

    更新日期:2014-07-01 00:00:00

  • From quantitative microscopy to automated image understanding.

    abstract::Quantitative microscopy has been extensively used in biomedical research and has provided significant insights into structure and dynamics at the cell and tissue level. The entire procedure of quantitative microscopy is comprised of specimen preparation, light absorption/reflection/emission from the specimen, microsco...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.1779233

    authors: Huang K,Murphy RF

    更新日期:2004-09-01 00:00:00

  • Measuring hemoglobin spectra: searching for carbamino-hemoglobin.

    abstract:SIGNIFICANCE:The arterial carbon dioxide (CO2) partial pressure PaCO2 is a clinically relevant variable. However, its measurement requires arterial blood sampling or bulky and expensive transcutaneous PtcCO2 meters. While the spectrophotometric determination of hemoglobin species-such as oxy-hemoglobin (O2Hb) and deoxy...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.10.105001

    authors: Dervieux E,Bodinier Q,Uhring W,Théron M

    更新日期:2020-10-01 00:00:00

  • Voxel-based measurement sensitivity of spatially resolved near-infrared spectroscopy in layered tissues.

    abstract::We quantitatively investigated the measurement sensitivity of spatially resolved spectroscopy (SRS) across six tissue models: cerebral tissue, a small animal brain, the forehead of a fetus, an adult brain, forearm muscle, and thigh muscle. The optical path length in the voxel of the model was analyzed using Monte Carl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.3.030503

    authors: Niwayama M

    更新日期:2018-03-01 00:00:00