Quantitative imaging of protein-protein interactions by multiphoton fluorescence lifetime imaging microscopy using a streak camera.

Abstract:

:Fluorescence lifetime imaging microscopy (FLIM) using multiphoton excitation techniques is now finding an important place in quantitative imaging of protein-protein interactions and intracellular physiology. Recent developments in multiphoton FLIM methods are reviewed and a novel multiphoton FLIM system using a streak camera is described. An example of a typical application of the system is provided in which the fluorescence resonance energy transfer between a donor-acceptor pair of fluorescent proteins within a cellular specimen is measured.

journal_name

J Biomed Opt

authors

Krishnan RV,Masuda A,Centonze VE,Herman B

doi

10.1117/1.1577574

subject

Has Abstract

pub_date

2003-07-01 00:00:00

pages

362-7

issue

3

eissn

1083-3668

issn

1560-2281

journal_volume

8

pub_type

杂志文章
  • In vivo photoacoustic imaging of blood vessels using a homodyne interferometer with zero-crossing triggering.

    abstract::We demonstrate a quasinoncontact photoacoustic imaging method using a homodyne interferometer with a long coherence length laser. The generated photoacoustic signal is detected by a system that is locked at its maximum sensitivity through the use of balanced detection and zero-crossing triggering. The balanced detecto...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.3.036002

    authors: Lu J,Gao Y,Ma Z,Zhou H,Wang RK,Wang Y

    更新日期:2017-03-01 00:00:00

  • Comparison of spectroscopically measured tissue alcohol concentration to blood and breath alcohol measurements.

    abstract::Alcohol testing is an expanding area of interest due to the impacts of alcohol abuse that extend well beyond drunk driving. However, existing approaches such as blood and urine assays are hampered in some testing environments by biohazard risks. A noninvasive, in vivo spectroscopic technique offers a promising alterna...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3253353

    authors: Ridder TD,Ver Steeg BJ,Laaksonen BD

    更新日期:2009-09-01 00:00:00

  • Stress analysis in oral obturator prostheses, part II: photoelastic imaging.

    abstract::In part I of the study, two attachment systems [O-ring; bar-clip (BC)] were used, and the system with three individualized O-rings provided the lowest stress on the implants and the support tissues. Therefore, the aim of this study was to assess the stress distribution, through the photoelastic method, on implant-reta...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.6.066012

    authors: Pesqueira AA,Goiato MC,da Silva EV,Haddad MF,Moreno A,Zahoui A,dos Santos DM

    更新日期:2014-06-01 00:00:00

  • Raman spectroscopy of in vivo cutaneous melanin.

    abstract::We successfully acquire the in vivo Raman spectrum of melanin from human skin using a rapid near-infrared (NIR) Raman spectrometer. The Raman signals of in vivo cutaneous melanin are similar to those observed from natural and synthetic eumelanins. The melanin Raman spectrum is dominated by two intense and broad peaks ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1805553

    authors: Huang Z,Lui H,Chen XK,Alajlan A,McLean DI,Zeng H

    更新日期:2004-11-01 00:00:00

  • Novel fluorescent oxygen indicator for intracellular oxygen measurements.

    abstract::Intracellular oxygen concentration is of primary importance in determining numerous physiological and pathological processes in biological systems. In this paper, we describe the application of the oxygen sensing indicator, ruthenium dibipyridine 4-(1"-pyrenyl)-2,2'-bipyridine chloride [Ru(bpy-pyr)(bpy)(2)], for molec...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1483082

    authors: Ji J,Rosenzweig N,Jones I,Rosenzweig Z

    更新日期:2002-07-01 00:00:00

  • Imaging tumor hypoxia by near-infrared fluorescence tomography.

    abstract::We have developed a novel nitroimidazole indocyanine dye conjugate for tumor-targeted hypoxia fluorescence tomography. The hypoxia probe has been evaluated in vitro using tumor cell lines and in vivo with tumor targeting in mice. The in vitro cell studies were performed to assess fluorescence labeling differences betw...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3589348

    authors: Biswal NC,Pavlik C,Smith MB,Aguirre A,Xu Y,Zanganeh S,Kuhn LT,Claffey KP,Zhu Q

    更新日期:2011-06-01 00:00:00

  • Heterodyne swept-source optical coherence tomography for complete complex conjugate ambiguity removal.

    abstract::Fourier domain (FD) techniques have increasingly gained attention in optical coherence tomography (OCT). This is primarily due to their demonstrated sensitivity of two to three orders of magnitude over conventional time-domain techniques. FDOCT images are subject to two primary sources of artifacts. First, a complex c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2136147

    authors: Davis AM,Choma MA,Izatt JA

    更新日期:2005-11-01 00:00:00

  • Tool for simulating the focusing of arbitrary vector beams in free-space and stratified media.

    abstract::Vectorial models of focused beams are important to a variety of fields including microscopy, lithography, optical physics, and biomedical imaging. This has led to many models being developed, which calculate how beams of various profiles are focused both in free space and in the presence of stratified media. The major...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.9.090801

    authors: Munro PRT

    更新日期:2018-09-01 00:00:00

  • Dynamics of retinal photocoagulation and rupture.

    abstract::In laser retinal photocoagulation, short (<20 ms) pulses have been found to reduce thermal damage to the inner retina, decrease treatment time, and minimize pain. However, the safe therapeutic window (defined as the ratio of power for producing a rupture to that of mild coagulation) decreases with shorter exposures. T...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3130282

    authors: Sramek C,Paulus Y,Nomoto H,Huie P,Brown J,Palanker D

    更新日期:2009-05-01 00:00:00

  • In vivo assessment and evaluation of lung tissue morphologic and physiological changes from non-contact endoscopic reflectance spectroscopy for improving lung cancer detection.

    abstract::We present a method for lung cancer detection exploiting reflectance spectra measured in vivo during endoscopic imaging of the lung. The measured reflectance spectra were analyzed using a specially developed light-transport model to obtain quantitative information about cancer-related, physiological, and morphologic c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2337529

    authors: Fawzy YS,Petek M,Tercelj M,Zeng H

    更新日期:2006-07-01 00:00:00

  • Differential optical spectropolarimetric imaging system assisted by liquid crystal devices for skin imaging.

    abstract::Skin cancer diagnosis depends not only on histopathological examination but also on visual inspection before and after the excision of suspected lesion. Neoplasm is accompanied with changes in birefringence of collagen, pleomorphicity, and hyperchromatic state of epithelial nuclei. These phenomena can be measured by s...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3609003

    authors: Aharon O,Abdulhalim I,Arnon O,Rosenberg L,Dyomin V,Silberstein E

    更新日期:2011-08-01 00:00:00

  • Statistical strategies to reveal potential vibrational markers for in vivo analysis by confocal Raman spectroscopy.

    abstract::The analysis of biological systems by spectroscopic techniques involves the evaluation of hundreds to thousands of variables. Hence, different statistical approaches are used to elucidate regions that discriminate classes of samples and to propose new vibrational markers for explaining various phenomena like disease m...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.7.075010

    authors: Oliveira Mendes Td,Pinto LP,Santos LD,Tippavajhala VK,Téllez Soto CA,Martin AA

    更新日期:2016-07-01 00:00:00

  • Correlation of in vivo photosensitizer fluorescence and photodynamic-therapy-induced depth of necrosis in a murine tumor model.

    abstract::We compared light-induced fluorescence (LIF) to nominal injected drug dose for predicting the depth of necrosis response to photodynamic therapy (PDT) in a murine tumor model. Mice were implanted with radiation-induced fibrosarcoma (RIF) and were injected with 0, 5, or 10 mg/kg Photofrin. 630-nm light (30 J/cm(2), 75 ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1560011

    authors: Cheung R,Solonenko M,Busch TM,Del Piero F,Putt ME,Hahn SM,Yodh AG

    更新日期:2003-04-01 00:00:00

  • Optical delivery of liposome encapsulated chemical stimuli to neuronal cells.

    abstract::Spatially confined and precise time delivery of neuroactive molecules is an important issue in neurophysiology. In this work we developed a technique for delivering chemical stimuli to cultured neurons consisting in encapsulating the molecules of interest in liposomes. These vectors were then loaded in reservoirs cons...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3616133

    authors: Pinato G,Raffaelli T,D'Este E,Tavano F,Cojoc D

    更新日期:2011-09-01 00:00:00

  • Spectral imaging technique for retinal perfusion detection using confocal scanning laser ophthalmoscopy.

    abstract::To evaluate retinal perfusion in the human eye, a dual-wavelength confocal scanning laser ophthalmoscope (cSLO) was developed that provides spectral imaging of the fundus using a combination of red (670 nm) and near-infrared (810 nm) wavelengths. The image of the ocular fundus was analyzed to find out if quantitative ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.11.116005

    authors: Rasta SH,Manivannan A,Sharp PF

    更新日期:2012-11-01 00:00:00

  • Surgical lighting with contrast enhancement based on spectral reflectance comparison and entropy analysis.

    abstract::Surgical light is important for helping the surgeon easily identify specific tissues during an operation. We propose a spectral reflectance comparison model to optimize the light-emitting diode light spectrum in the operating room. An entropy evaluation method, meant specifically for surgical situations, was developed...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.10.105012

    authors: Shen J,Wang H,Wu Y,Li A,Chen C,Zheng Z

    更新日期:2015-10-01 00:00:00

  • Measurement of the refractive index of whole blood and its components for a continuous spectral region.

    abstract::The refractive index of blood is a key biophysical parameter, which can reflect the physiological state. We measured the refractive index of whole blood and other components, such as serum, plasma, and hemoglobin, based on internal reflection by using a homemade apparatus in the spectral range of 400 to 750 nm. In add...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.3.035003

    authors: Liu S,Deng Z,Li J,Wang J,Huang N,Cui R,Zhang Q,Mei J,Zhou W,Zhang C,Ye Q,Tian J

    更新日期:2019-03-01 00:00:00

  • Depth profiling of photothermal compound concentrations using phase sensitive optical coherence tomography.

    abstract::A model that describes the concentration of photothermal (light-to-heat converters) compounds as a function of depth in a turbid medium is developed. The system consists of a pump laser (808 nm modulated at 400 Hz), which heats a photothermal compound, and a phase sensitive spectral domain optical coherence tomography...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3659211

    authors: Guan G,Reif R,Huang Z,Wang RK

    更新日期:2011-12-01 00:00:00

  • Moving-source elastic wave reconstruction for high-resolution optical coherence elastography.

    abstract::Optical coherence tomography (OCT)-based elasticity imaging can map soft tissue elasticity based on speckle-tracking of elastic wave propagation using highly sensitive phase measurements of OCT signals. Using a fixed elastic wave source and moving detection, current imaging sequences have difficulty in reconstructing ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.11.116006

    authors: Hsieh BY,Song S,Nguyen TM,Yoon SJ,Shen TT,Wang RK,O'Donnell M

    更新日期:2016-11-01 00:00:00

  • SpineLab: tool for three-dimensional reconstruction of neuronal cell morphology.

    abstract::SpineLab is a software tool developed for reconstructing neuronal feature skeletons from three-dimensional single- or multi-photon image stacks. These images often suffer from limited resolution and a low signal-to-noise ratio, making the extraction of morphometric information difficult. To overcome this limitation, w...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.076007

    authors: Jungblut D,Vlachos A,Schuldt G,Zahn N,Deller T,Wittum G

    更新日期:2012-07-01 00:00:00

  • "Seeing" electroencephalogram through the skull: imaging prefrontal cortex with fast optical signal.

    abstract::Near-infrared spectroscopy is a novel imaging technique potentially sensitive to both brain hemodynamics (slow signal) and neuronal activity (fast optical signal, FOS). The big challenge of measuring FOS noninvasively lies in the presumably low signal-to-noise ratio. Thus, detectability of the FOS has been controversi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3505007

    authors: Medvedev AV,Kainerstorfer JM,Borisov SV,Gandjbakhche AH,Vanmeter J

    更新日期:2010-11-01 00:00:00

  • Three-beam spectral-domain optical coherence tomography for retinal imaging.

    abstract::A three-beam spectral domain optical coherence tomography system (OCT) whose center wavelength is 840 nm was developed. The three beams focus on fundus 3.1 mm apart from each other and are detected by a single line sensor. The distance between the beams is fixed and the beams scan a total area of 10×10  mm² while keep...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.10.106001

    authors: Suehira N,Ooto S,Hangai M,Matsumoto K,Tomatsu N,Yuasa T,Yamada K,Yoshimura N

    更新日期:2012-10-01 00:00:00

  • Real-time microscopic visualization of tissue response to laser thermal therapy.

    abstract::We present methods for visualizing the dynamic response of biological samples to laser-induced heating. Our approach utilizes optical frequency-domain imaging to detect, spatially localize, and monitor unique dynamic signatures that arise within zones of active tissue denaturation. Since this information is precisely ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714027

    authors: Vakoc BJ,Tearney GJ,Bouma BE

    更新日期:2007-03-01 00:00:00

  • Low-frequency wide-field fluorescence lifetime imaging using a high-power near-infrared light-emitting diode light source.

    abstract::Fluorescence lifetime imaging (FLi) could potentially improve exogenous near-infrared (NIR) fluorescence imaging, because it offers the capability of discriminating a signal of interest from background, provides real-time monitoring of a chemical environment, and permits the use of several different fluorescent dyes h...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3368997

    authors: Gioux S,Lomnes SJ,Choi HS,Frangioni JV

    更新日期:2010-03-01 00:00:00

  • Label-free imaging of biomolecules in food products using stimulated Raman microscopy.

    abstract::The development of methods that allow microscale studies of complex biomaterials based on their molecular composition is of great interest to a wide range of research fields. We show that stimulated Raman scattering (SRS) microscopy is an excellent analytical tool to study distributions of different biomolecules in mu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3516591

    authors: Roeffaers MB,Zhang X,Freudiger CW,Saar BG,van Ruijven M,van Dalen G,Xiao C,Xie XS

    更新日期:2010-11-01 00:00:00

  • Video-rate optical flow corrected intraoperative functional fluorescence imaging.

    abstract::Intraoperative fluorescence molecular imaging based on targeted fluorescence agents is an emerging approach to improve surgical and endoscopic imaging and guidance. Short exposure times per frame and implementation at video rates are necessary to provide continuous feedback to the physician and avoid motion artifacts....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.4.046012

    authors: Koch M,Glatz J,Ermolayev V,de Vries EG,van Dam GM,Englmeier KH,Ntziachristos V

    更新日期:2014-04-01 00:00:00

  • Anomalous photobleaching in fluorescence recovery after photobleaching measurements due to excitation saturation--a case study for fluorescein.

    abstract::In this study we examine the implications of excitation saturation on fluorescence recovery after photobleaching (FRAP) experiments. In particular we present both experimental and theoretical evidence that fluorescein, one of the most frequently used fluorophores in FRAP, does not always comply with the basic assumpti...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2337531

    authors: Braeckmans K,Stubbe BG,Remaut K,Demeester J,De Smedt SC

    更新日期:2006-07-01 00:00:00

  • Processing algorithms for tracking speckle shifts in optical elastography of biological tissues.

    abstract::Parametric and nonparametric data processing schemes for analyzing translating laser speckle data used to investigate the mechanical behavior of biological tissues are examined. Cross-correlation, minimum mean square estimator, maximum likelihood, and maximum entropy approaches are discussed and compared on speckle da...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1412224

    authors: Duncan DD,Kirkpatrick SJ

    更新日期:2001-10-01 00:00:00

  • Machine learning approach for rapid and accurate estimation of optical properties using spatial frequency domain imaging.

    abstract::Fast estimation of optical properties from reflectance measurements at two spatial frequencies could pave way for real-time, wide-field and quantitative mapping of vital signs of tissues. We present a machine learning-based approach for estimating optical properties in the spatial frequency domain, where a random fore...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.7.071606

    authors: Panigrahi S,Gioux S

    更新日期:2018-12-01 00:00:00

  • Evaluating the use of optical coherence tomography for the detection of epithelial cancers in vitro.

    abstract::Optical coherence tomography (OCT) is a noninvasive imaging methodology that is able to image tissue to depths of over 1 mm. Many epithelial conditions, such as melanoma and oral cancers, require an invasive biopsy for diagnosis. A noninvasive, real-time, point of care method of imaging depth-resolved epithelial struc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3652708

    authors: Smith LE,Hearnden V,Lu Z,Smallwood R,Hunter KD,Matcher SJ,Thornhill MH,Murdoch C,MacNeil S

    更新日期:2011-11-01 00:00:00