Imaging tumor hypoxia by near-infrared fluorescence tomography.

Abstract:

:We have developed a novel nitroimidazole indocyanine dye conjugate for tumor-targeted hypoxia fluorescence tomography. The hypoxia probe has been evaluated in vitro using tumor cell lines and in vivo with tumor targeting in mice. The in vitro cell studies were performed to assess fluorescence labeling differences between hypoxia and normoxia conditions. When treated with the hypoxia probe, a fluorescence emission ratio of 2.5-fold was found between the cells incubated under hypoxia compared to the cells in normoxia condition. Hypoxia specificity was also confirmed by comparing the cells treated with indocyanine dye alone. In vivo tumor targeting in mice showed that the fluorescence signals measured at the tumor site were twice those at the normal site after 150 min post-injection of the hypoxia probe. On the other hand, the fluorescence signals measured after injection of indocyanine dye were the same at tumor and normal sites. In vivo fluorescence tomography images of mice injected with the hypoxia probe showed that the probe remained for more than 5 to 7 h in the tumors, however, the images of mice injected with indocyanine only dye confirmed that the unbound dye washed out in less than 3 h. These findings are supported with fluorescence images of histological sections of tumor samples using a Li-COR scanner and immunohistochemistry technique for tumor hypoxia.

journal_name

J Biomed Opt

authors

Biswal NC,Pavlik C,Smith MB,Aguirre A,Xu Y,Zanganeh S,Kuhn LT,Claffey KP,Zhu Q

doi

10.1117/1.3589348

subject

Has Abstract

pub_date

2011-06-01 00:00:00

pages

066009

issue

6

eissn

1083-3668

issn

1560-2281

journal_volume

16

pub_type

杂志文章
  • Hardware implementation algorithm and error analysis of high-speed fluorescence lifetime sensing systems using center-of-mass method.

    abstract::A new, simple, high-speed, and hardware-only integration-based fluorescence-lifetime-sensing algorithm using a center-of-mass method (CMM) is proposed to implement lifetime calculations, and its signal-to-noise-ratio based on statistics theory is also deduced. Compared to the commonly used iterative least-squares meth...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3309737

    authors: Li DU,Rae B,Andrews R,Arlt J,Henderson R

    更新日期:2010-01-01 00:00:00

  • Study of the inhibition effect of thiazone on muscle optical clearing.

    abstract::We investigated the effect of thiazone, a widely used penetration enhancer, on in vitro porcine skin and muscle tissue by single-integrating sphere technique during optical clearing (OC) treatment. The results showed that thiazone induced an increase on the total transmittance of skin which led to a reduction in that ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.10.105004

    authors: Jin X,Deng Z,Wang J,Ye Q,Mei J,Zhou W,Zhang C,Tian J

    更新日期:2016-10-01 00:00:00

  • Optical fiber Bragg grating-instrumented silicone liner for interface pressure measurement within prosthetic sockets of lower-limb amputees.

    abstract::This paper presents a fiber Bragg grating (FBG)-instrumented prosthetic silicone liner that provides cushioning for the residual limb and can successfully measure interface pressures inside prosthetic sockets of lower-limb amputees in a simple and practical means of sensing. The liner is made of two silicone layers be...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.8.087001

    authors: Al-Fakih E,Arifin N,Pirouzi G,Mahamd Adikan FR,Shasmin HN,Abu Osman NA

    更新日期:2017-08-01 00:00:00

  • In vivo label-free quantification of liver microcirculation using dual-modality microscopy.

    abstract::Microcirculation lesion is a common symptom of chronic liver diseases in the form of vasculature deformation and circulation alteration. In acute to chronic liver diseases such as biliary atresia, microcirculation lesion can have an early onset. Detection of microcirculation lesion is meaningful for studying the progr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.116006

    authors: Yan J,Kang Y,Xu S,Ong LL,Zhuo S,Bunte RM,Chen N,Asada HH,So PT,Wanless IR,Yu H

    更新日期:2014-01-01 00:00:00

  • Differentiation of benign and malignant breast tumors by in-vivo three-dimensional parallel-plate diffuse optical tomography.

    abstract::We have developed a novel parallel-plate diffuse optical tomography (DOT) system for three-dimensional in vivo imaging of human breast tumor based on large optical data sets. Images of oxy-, deoxy-, and total hemoglobin concentration as well as blood oxygen saturation and tissue scattering were reconstructed. Tumor ma...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3103325

    authors: Choe R,Konecky SD,Corlu A,Lee K,Durduran T,Busch DR,Pathak S,Czerniecki BJ,Tchou J,Fraker DL,Demichele A,Chance B,Arridge SR,Schweiger M,Culver JP,Schnall MD,Putt ME,Rosen MA,Yodh AG

    更新日期:2009-03-01 00:00:00

  • Infrared laser thermal fusion of blood vessels: preliminary ex vivo tissue studies.

    abstract::Suture ligation of blood vessels during surgery can be time-consuming and skill-intensive. Energy-based, electrosurgical, and ultrasonic devices have recently replaced the use of sutures and mechanical clips (which leave foreign objects in the body) for many surgical procedures, providing rapid hemostasis during surge...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.5.058001

    authors: Cilip CM,Rosenbury SB,Giglio N,Hutchens TC,Schweinsberger GR,Kerr D,Latimer C,Nau WH,Fried NM

    更新日期:2013-05-01 00:00:00

  • Fluorescence microscopy imaging of electroperturbation in mammalian cells.

    abstract::We report the design, integration, and validation of a fluorescence microscopy system for imaging of electroperturbation--the effects of nanosecond, megavolt-per-meter pulsed electric fields on biological cells and tissues. Such effects have potential applications in cancer therapy, gene regulation, and biophysical re...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2187970

    authors: Sun Y,Vernier PT,Behrend M,Wang J,Thu MM,Gundersen M,Marcu L

    更新日期:2006-03-01 00:00:00

  • Differentiation of cancer cells in two-dimensional and three-dimensional breast cancer models by Raman spectroscopy.

    abstract::We demonstrate the first application of Raman spectroscopy in diagnosing nonmalignant, premalignant, malignant, and metastatic stages of breast cancer in a three-dimensional (3-D) cell culture model that closely mimics an in vivo environment. Comprehensive study comparing classification in two-dimensional (2-D) and 3-...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.11.117008

    authors: Damayanti NP,Fang Y,Parikh MR,Craig AP,Kirshner J,Irudayaraj J

    更新日期:2013-11-01 00:00:00

  • Retinal blood flow measurement by circumpapillary Fourier domain Doppler optical coherence tomography.

    abstract::We present in vivo human total retinal blood flow measurements using Doppler Fourier domain optical coherence tomography (OCT). The scan pattern consisted of two concentric circles around the optic nerve head, transecting all retinal branch arteries and veins. The relative positions of each blood vessel in the two OCT...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2998480

    authors: Wang Y,Bower BA,Izatt JA,Tan O,Huang D

    更新日期:2008-11-01 00:00:00

  • Holographic laser Doppler imaging of pulsatile blood flow.

    abstract::We report on wide-field imaging of pulsatile motion induced by blood flow using heterodyne holographic interferometry on the thumb of a healthy volunteer, in real time. Optical Doppler images were measured with green laser light by a frequency-shifted Mach-Zehnder interferometer in off-axis configuration. The recorded...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.6.066006

    authors: Bencteux J,Pagnoux P,Kostas T,Bayat S,Atlan M

    更新日期:2015-06-01 00:00:00

  • Optically sectioned in vivo imaging with speckle illumination HiLo microscopy.

    abstract::We present a simple wide-field imaging technique, called HiLo microscopy, that is capable of producing optically sectioned images in real time, comparable in quality to confocal laser scanning microscopy. The technique is based on the fusion of two raw images, one acquired with speckle illumination and another with st...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3528656

    authors: Lim D,Ford TN,Chu KK,Mertz J

    更新日期:2011-01-01 00:00:00

  • Change of tumor vascular reactivity during tumor growth and postchemotherapy observed by near-infrared spectroscopy.

    abstract::Breast cancer is one of the most common cancers in females. To monitor chemotherapeutic efficacy for breast cancer, medical imaging systems such as x-ray mammography, computed tomography, magnetic resonance imaging, and ultrasound imaging have been used. Currently, it can take up to 3 to 6 weeks to see the tumor respo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.12.121603

    authors: Lee S,Jeong H,Seong M,Kim JG

    更新日期:2017-12-01 00:00:00

  • Monitoring of tumor response to cisplatin by subsurface fluorescence molecular tomography.

    abstract::Subsurface fluorescence molecular tomography (FMT) has promising potential for noninvasive characterization of molecular and cellular activities in small animals by tomographic means in reflectance geometry. In this work, subsurface FMT is employed to monitor the therapeutic response of cisplatin in tumor-bearing mice...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.17.4.040504

    authors: Liu F,Cao X,He W,Song J,Dai Z,Zhang B,Luo J,Li Y,Bai J

    更新日期:2012-04-01 00:00:00

  • Endoscopic swept-source optical coherence tomography based on a two-axis microelectromechanical system mirror.

    abstract::A microelectromechanical system (MEMS) mirror based endoscopic swept-source optical coherence tomography (SS-OCT) system that can perform three-dimensional (3-D) imaging at high speed is reported. The key component enabling 3-D endoscopic imaging is a two-axis MEMS scanning mirror which has a 0.8×0.8  mm2 mirror plate...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.8.086005

    authors: Wang D,Fu L,Wang X,Gong Z,Samuelson S,Duan C,Jia H,Ma JS,Xie H

    更新日期:2013-08-01 00:00:00

  • Europium-quantum dot nanobioconjugates as luminescent probes for time-gated biosensing.

    abstract::Nanobioconjugates have been synthesized using cadmium selenide quantum dots (QDs), europium complexes (EuCs), and biotin. In those conjugates, long-lived photoluminescence (PL) is provided by the europium complexes, which efficiently transfer energy via Förster resonance energy transfer (FRET) to the QDs in close spat...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.101506

    authors: Cywinski PJ,Hammann T,Hühn D,Parak WJ,Hildebrandt N,Löhmannsröben HG

    更新日期:2014-01-01 00:00:00

  • Monte Carlo simulation of multiphoton fluorescence microscopic imaging through inhomogeneous tissuelike turbid media.

    abstract::Image resolution and signal level in fluorescence microscopy through inhomogeneous turbid media consisting of scatterers of multiple sizes under single- (1p), two- (2p), and three-photon (3p) excitation have been investigated based on a modified Monte Carlo model. The effects of the size distribution and the concentra...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1577116

    authors: Deng X,Gan X,Gu M

    更新日期:2003-07-01 00:00:00

  • Spectrally resolved fluorescence lifetime imaging to investigate cell metabolism in malignant and nonmalignant oral mucosa cells.

    abstract::Fluorescence-guided diagnosis of tumor tissue is in many cases insufficient, because false positive results interfere with the outcome. Improvement through observation of cell metabolism might offer the solution, but needs a detailed understanding of the origin of autofluorescence. With respect to this, spectrally res...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.9.096005

    authors: Rück A,Hauser C,Mosch S,Kalinina S

    更新日期:2014-09-01 00:00:00

  • Performance assessment of time-domain optical brain imagers, part 2: nEUROPt protocol.

    abstract::The nEUROPt protocol is one of two new protocols developed within the European project nEUROPt to characterize the performances of time-domain systems for optical imaging of the brain. It was applied in joint measurement campaigns to compare the various instruments and to assess the impact of technical improvements. T...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.8.086012

    authors: Wabnitz H,Jelzow A,Mazurenka M,Steinkellner O,Macdonald R,Milej D,Żołek N,Kacprzak M,Sawosz P,Maniewski R,Liebert A,Magazov S,Hebden J,Martelli F,Di Ninni P,Zaccanti G,Torricelli A,Contini D,Re R,Zucchelli L,Spine

    更新日期:2014-08-01 00:00:00

  • Mueller matrix decomposition for determination of optical rotation of glucose molecules in turbid media.

    abstract::The optical activity of glucose molecules is important for diagnosing and monitoring blood glucose of diabetes. In order to accurately detect the diabetes at an early stage, there is an urgent need to develop innovative detection methods. By use of Mueller matrix decomposition (MMD), we have studied the optical activi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.4.046015

    authors: Sun P,Ma Y,Liu W,Yang Q,Jia Q

    更新日期:2014-04-01 00:00:00

  • Differential optical spectropolarimetric imaging system assisted by liquid crystal devices for skin imaging.

    abstract::Skin cancer diagnosis depends not only on histopathological examination but also on visual inspection before and after the excision of suspected lesion. Neoplasm is accompanied with changes in birefringence of collagen, pleomorphicity, and hyperchromatic state of epithelial nuclei. These phenomena can be measured by s...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3609003

    authors: Aharon O,Abdulhalim I,Arnon O,Rosenberg L,Dyomin V,Silberstein E

    更新日期:2011-08-01 00:00:00

  • Real-time intraoperative fluorescence imaging system using light-absorption correction.

    abstract::We present a novel fluorescence imaging system developed for real-time interventional imaging applications. The system implements a correction scheme that improves the accuracy of epi-illumination fluorescence images for light intensity variation in tissues. The implementation is based on the use of three cameras oper...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3259362

    authors: Themelis G,Yoo JS,Soh KS,Schulz R,Ntziachristos V

    更新日期:2009-11-01 00:00:00

  • In vivo microvascular network imaging of the human retina combined with an automatic three-dimensional segmentation method.

    abstract::Microvascular network of the retina plays an important role in diagnosis and monitoring of various retinal diseases. We propose a three-dimensional (3-D) segmentation method with intensity-based Doppler variance (IBDV) based on swept-source optical coherence tomography. The automatic 3-D segmentation method is used to...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.7.076003

    authors: Huang S,Piao Z,Zhu J,Lu F,Chen Z

    更新日期:2015-07-01 00:00:00

  • Comparison of motion correction techniques applied to functional near-infrared spectroscopy data from children.

    abstract::Motion artifacts are the most significant sources of noise in the context of pediatric brain imaging designs and data analyses, especially in applications of functional near-infrared spectroscopy (fNIRS), in which it can completely affect the quality of the data acquired. Different methods have been developed to corre...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.12.126003

    authors: Hu XS,Arredondo MM,Gomba M,Confer N,DaSilva AF,Johnson TD,Shalinsky M,Kovelman I

    更新日期:2015-01-01 00:00:00

  • Generalized Beer-Lambert model for near-infrared light propagation in thick biological tissues.

    abstract::The attenuation of near-infrared (NIR) light intensity as it propagates in a turbid medium like biological tissue is described by modified the Beer–Lambert law (MBLL). The MBLL is generally used to quantify the changes in tissue chromophore concentrations for NIR spectroscopic data analysis. Even though MBLL is effect...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.7.076012

    authors: Bhatt M,Ayyalasomayajula KR,Yalavarthy PK

    更新日期:2016-07-01 00:00:00

  • Study on application of optical clearing technique in skin diseases.

    abstract::So far, the study of the optical clearing is almost always about healthy tissue. However, the ultimate goal is to detect diseases for clinical application. Optical clearing on diseased skins is explored. The effect is evaluated by applying a combined liquid paraffin and glycerol mixed solution on several kinds of dise...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.11.115003

    authors: Shan H,Liang Y,Wang J,Li Y

    更新日期:2012-11-01 00:00:00

  • Human graft cornea and laser incisions imaging with micrometer scale resolution full-field optical coherence tomography.

    abstract::Micrometer scale resolution full-field optical coherence tomography (FF-OCT) is developed for imaging human graft corneas. Three-dimensional (3-D) images with ultrahigh resolution (respectively, 1 and 1.5 μm in the axial and transverse directions), comparable to traditional histological sections, are obtained allowing...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3486544

    authors: Latour G,Georges G,Lamoine LS,Deumié C,Conrath J,Hoffart L

    更新日期:2010-09-01 00:00:00

  • Detection of canine skin and subcutaneous tumors by visible and near-infrared diffuse reflectance spectroscopy.

    abstract::Cancer is the main cause of canine morbidity and mortality. The existing evaluation of tumors requires an experienced veterinarian and usually includes invasive procedures (e.g., fine-needle aspiration) that can be unpleasant for the dog and the owner. We investigate visible and near-infrared diffuse reflectance spect...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.3.037003

    authors: Cugmas B,Plavec T,Bregar M,Naglič P,Pernuš F,Likar B,Bürmen M

    更新日期:2015-03-01 00:00:00

  • Combined ultrasound and photoacoustic imaging to detect and stage deep vein thrombosis: phantom and ex vivo studies.

    abstract::Treatment of deep venous thrombosis (DVT)--a primary cause of potentially fatal pulmonary embolism (PE)--depends on the age of the thrombus. The existing clinical imaging methods are capable of visualizing a thrombus but cannot determine the age of the blood clot. Therefore, there is a need for an imaging technique to...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2992175

    authors: Karpiouk AB,Aglyamov SR,Mallidi S,Shah J,Scott WG,Rubin JM,Emelianov SY

    更新日期:2008-09-01 00:00:00

  • Characterization and three-dimensional localization of cancerous prostate tissue using backscattering scanning polarization imaging and independent component analysis.

    abstract::Characterization and three-dimensional (3-D) localization of human cancerous prostate tissue embedded in normal prostate tissue were demonstrated using backscattering scanning polarization imaging and an inverse imaging reconstruction algorithm, optical tomography using independent component analysis (OPTICA). Two-dim...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.081419

    authors: Pu Y,Wang W,Xu M,Eastham JA,Tang G,Alfano RR

    更新日期:2012-08-01 00:00:00

  • Determination of optical scattering properties in turbid media using Mueller matrix imaging.

    abstract::A need exists for the continued development of diagnostic tools and methods capable of distinguishing and characterizing slight differences in the optical properties of tissues. We present a method to estimate the scattering coefficient contribution as a function of particle size in complex mixtures of polystyrene sph...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2363347

    authors: Cameron BD,Li Y,Nezhuvingal A

    更新日期:2006-09-01 00:00:00