Correlation of in vivo photosensitizer fluorescence and photodynamic-therapy-induced depth of necrosis in a murine tumor model.

Abstract:

:We compared light-induced fluorescence (LIF) to nominal injected drug dose for predicting the depth of necrosis response to photodynamic therapy (PDT) in a murine tumor model. Mice were implanted with radiation-induced fibrosarcoma (RIF) and were injected with 0, 5, or 10 mg/kg Photofrin. 630-nm light (30 J/cm(2), 75 mW/cm(2)) was delivered to the tumor after 24 hours. Fluorescence emission (lambda(excitation)=545 nm, lambda( emission)=628 nm) from the tumor was measured. The LIF data had less scatter than injected drug dose, and was found to be at least as good as an injected drug dose for predicting the depth of necrosis after PDT. Our observations provide further evidence that fluorescence spectroscopy can be used to quantify tissue photosensitizer uptake and to predict PDT tissue damage.

journal_name

J Biomed Opt

authors

Cheung R,Solonenko M,Busch TM,Del Piero F,Putt ME,Hahn SM,Yodh AG

doi

10.1117/1.1560011

subject

Has Abstract

pub_date

2003-04-01 00:00:00

pages

248-52

issue

2

eissn

1083-3668

issn

1560-2281

journal_volume

8

pub_type

杂志文章
  • Spatially resolved optical and ultrastructural properties of colorectal and pancreatic field carcinogenesis observed by inverse spectroscopic optical coherence tomography.

    abstract::Field carcinogenesis is the initial stage of cancer progression. Understanding field carcinogenesis is valuable for both cancer biology and clinical medicine. Here, we used inverse spectroscopic optical coherence tomography to study colorectal cancer (CRC) and pancreatic cancer (PC) field carcinogenesis. Depth-resolve...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.3.036013

    authors: Yi J,Radosevich AJ,Stypula-Cyrus Y,Mutyal NN,Azarin SM,Horcher E,Goldberg MJ,Bianchi LK,Bajaj S,Roy HK,Backman V

    更新日期:2014-03-01 00:00:00

  • No-core fiber-based highly sensitive optical fiber pH sensor.

    abstract::The present work describes the fabrication and characterization of an optical fiber pH sensor using a sol–gel technique. The sensing head configuration is incorporated using a short section of no-core fiber, coated with tetraethyl orthosilicate and spliced at the end of a single mode fiber with a bulge. Different type...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.5.057001

    authors: Bhardwaj V,Pathak AK,Singh VK

    更新日期:2017-05-01 00:00:00

  • Measurement and imaging of birefringent properties of the human cornea with phase-resolved, polarization-sensitive optical coherence tomography.

    abstract::Optical coherence tomography (OCT) is an emerging technology for high-resolution, noncontact imaging of transparent and scattering media. Polarization-sensitive optical coherence tomography (PS-OCT) is a functional extension of OCT that can image birefringent properties of a biological sample. PS-OCT was used to measu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1629308

    authors: Götzinger E,Pircher M,Sticker M,Fercher AF,Hitzenberger CK

    更新日期:2004-01-01 00:00:00

  • Multiplexed neural recording along a single optical fiber via optical reflectometry.

    abstract::We introduce the design and theoretical analysis of a fiber-optic architecture for neural recording without contrast agents, which transduces neural electrical signals into a multiplexed optical readout. Our sensor design is inspired by electro-optic modulators, which modulate the refractive index of a waveguide by ap...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.5.057003

    authors: Rodriques SG,Marblestone AH,Scholvin J,Dapello J,Sarkar D,Mankin M,Gao R,Wood L,Boyden ES

    更新日期:2016-05-01 00:00:00

  • Enhanced thulium fiber laser lithotripsy using micro-pulse train modulation.

    abstract::The thulium fiber laser (TFL) is currently being studied as an alternative to the conventional holmium:YAG (Ho:YAG) laser for lithotripsy. The diode-pumped TFL may be electronically modulated to operate with variable parameters (e.g., pulse rate, pulse duration, and duty cycle) for studying the influence of pulse trai...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.2.028002

    authors: Blackmon RL,Irby PB,Fried NM

    更新日期:2012-02-01 00:00:00

  • Reproducibility of parameters of postocclusive reactive hyperemia measured by diffuse optical tomography.

    abstract::The application of near-infrared spectroscopy (NIRS) to assess microvascular function has shown promising results. An important limitation when using a single source-detector pair, however, is the lack of depth sensitivity. Diffuse optical tomography (DOT) overcomes this limitation using an array of sources and detect...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.6.066012

    authors: Vidal-Rosas EE,Billings SA,Chico T,Coca D

    更新日期:2016-06-01 00:00:00

  • Near-infrared fluorescence goggle system with complementary metal-oxide-semiconductor imaging sensor and see-through display.

    abstract::We have developed a near-infrared (NIR) fluorescence goggle system based on the complementary metal-oxide-semiconductor active pixel sensor imaging and see-through display technologies. The fluorescence goggle system is a compact wearable intraoperative fluorescence imaging and display system that can guide surgery in...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.10.101303

    authors: Liu Y,Njuguna R,Matthews T,Akers WJ,Sudlow GP,Mondal S,Tang R,Gruev V,Achilefu S

    更新日期:2013-10-01 00:00:00

  • Temperature-controlled in vivo ocular exposure to 1090-nm radiation suggests that near-infrared radiation cataract is thermally induced.

    abstract::The damage mechanism for near-infrared radiation (IRR) induced cataract is unclear. Both a photochemical and a thermal mechanism were suggested. The current paper aims to elucidate a photochemical effect based on investigation of irradiance-exposure time reciprocity. Groups of 20 rats were unilaterally exposed to 96-W...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.1.015003

    authors: Yu Z,Schulmeister K,Talebizadeh N,Kronschläger M,Söderberg P

    更新日期:2015-01-01 00:00:00

  • Comparison of motion correction techniques applied to functional near-infrared spectroscopy data from children (Erratum).

    abstract::The erratum concerns amendment of Section 2.5 of the published article. ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,已发布勘误

    doi:10.1117/1.JBO.25.5.059801

    authors: Hu XS,Arredondo MM,Gomba M,Confer N,DaSilva AF,Johnson TD,Shalinsky M,Kovelman I

    更新日期:2020-05-01 00:00:00

  • Modulation of an optical needle's reflectivity alters the average photon path through scattering media.

    abstract::We introduce the concept of deliberate placement of absorbers to alter the average path of photons through tissue for a biomedical optical device. By changing the reflectivity of a needle that separates a source and detector, the average photon path through a turbid medium can be changed. Totally reflective needles ha...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2168167

    authors: Simonson P,D'Amico E,Gratton E

    更新日期:2006-01-01 00:00:00

  • Inexpensive diffuse reflectance spectroscopy system for measuring changes in tissue optical properties.

    abstract::The measurement of changes in blood volume in tissue is important for monitoring the effects of a wide range of therapeutic interventions, from radiation therapy to skin-flap transplants. Many systems available for purchase are either expensive or difficult to use, limiting their utility in the clinical setting. A low...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.105005

    authors: Glennie DL,Hayward JE,McKee DE,Farrell TJ

    更新日期:2014-01-01 00:00:00

  • Evaluation of the contribution of the renal capsule and cortex to kidney autofluorescence intensity under ultraviolet excitation.

    abstract::The use of reduced nicotinamide adenine dinucleotide (NADH) fluorescence to gain metabolic information on kidneys in response to an alteration in oxygen availability has previously been experimentally demonstrated, but signal quantification has not, to date, been addressed. In this work the relative contribution to ra...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3094948

    authors: Raman RN,Pivetti CD,Rubenchik AM,Matthews DL,Troppmann C,Demos SG

    更新日期:2009-03-01 00:00:00

  • Vessel orientation-dependent sensitivity of optoacoustic imaging using a linear array transducer.

    abstract::For clinical optoacoustic imaging, linear probes are preferably used because they allow versatile imaging of the human body with real-time display and free-hand probe guidance. The two-dimensional (2-D) optoacoustic image obtained with this type of probe is generally interpreted as a 2-D cross-section of the tissue ju...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.2.026011

    authors: Preisser S,Bush NL,Gertsch-Grover AG,Peeters S,Bailey AE,Bamber JC,Frenz M,Jaeger M

    更新日期:2013-02-01 00:00:00

  • Quantification of fiber orientation in the canine atrial pacemaker complex using optical coherence tomography.

    abstract::The atrial pacemaker complex is responsible for the initiation and early propagation of cardiac impulses. Optical coherence tomography (OCT), a nondestructive imaging modality with spatial resolutions of ∼1 to 15 μm, can be used to identify unique fiber orientation patterns in this region of the heart. Functionally ch...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.071309

    authors: Ambrosi CM,Fedorov VV,Schuessler RB,Rollins AM,Efimov IR

    更新日期:2012-07-01 00:00:00

  • Lipid-cell interactions in human monocytes investigated by doubly-resonant coherent anti-Stokes Raman scattering microscopy.

    abstract::We demonstrate that doubly-resonant coherent anti-Stokes Raman scattering can provide enhanced and highly specific contrast for molecules containing unique Raman-active small molecular groups. This combination provides contrast for molecules that can otherwise be difficult to discriminate by Raman spectroscopy. Here, ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3544585

    authors: Weeks T,Schie I,den Hartigh LJ,Rutledge JC,Huser T

    更新日期:2011-02-01 00:00:00

  • Measurement of retinal blood flow in the rat by combining Doppler Fourier-domain optical coherence tomography with fundus imaging.

    abstract::A wide variety of ocular diseases are associated with abnormalities in ocular circulation. As such, there is considerable interest in techniques for quantifying retinal blood flow, among which Doppler optical coherence tomography (OCT) may be the most promising. We present an approach to measure retinal blood flow in ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.106008

    authors: Werkmeister RM,Vietauer M,Knopf C,Fürnsinn C,Leitgeb RA,Reitsamer H,Gröschl M,Garhöfer G,Vilser W,Schmetterer L

    更新日期:2014-01-01 00:00:00

  • Dynamic in vivo imaging of small animal brain using pulsed laser diode-based photoacoustic tomography system.

    abstract::We demonstrate dynamic in vivo imaging using a low-cost portable pulsed laser diode (PLD)-based photoacoustic tomography system. The system takes advantage of an 803-nm PLD having high-repetition rate ∼7000  Hz combined with a fast-scanning single-element ultrasound transducer leading to a 5 s cross-sectional imaging....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.9.090501

    authors: Upputuri PK,Pramanik M

    更新日期:2017-09-01 00:00:00

  • Two-photon imaging using adaptive phase compensated ultrashort laser pulses.

    abstract::An adaptive pulse shaper controlled by multiphoton intrapulse interference phase scanning (MIIPS) was used, together with a prism-pair, to measure and cancel high-order phase distortions introduced by a high-numerical-aperture objective and other dispersive elements of a two-photon laser-scanning microscope. The deliv...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3059629

    authors: Xi P,Andegeko Y,Pestov D,Lovozoy VV,Dantus M

    更新日期:2009-01-01 00:00:00

  • Spatial distribution of vastus lateralis blood flow and oxyhemoglobin saturation measured at the end of isometric quadriceps contraction by multichannel near-infrared spectroscopy.

    abstract::Muscle blood flow (MBF) and muscle oxygen saturation (SmO(2)) were measured at eight locations (four proximal, four distal) over a 4 x 8 cm(2) area of the vastus lateralis at rest and immediately after isometric, maximal quadriceps contraction using multichannel, frequency-domain, near-infrared spectroscopy. A venous ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1646417

    authors: Quaresima V,Ferrari M,Franceschini MA,Hoimes ML,Fantini S

    更新日期:2004-03-01 00:00:00

  • Use of picosecond Kerr-gated Raman spectroscopy to suppress signals from both surface and deep layers in bladder and prostate tissue.

    abstract::Raman spectroscopy is an optical technique able to interrogate biological tissues, giving us an understanding of the changes in molecular structure that are associated with disease development. The Kerr-gated Raman spectroscopy technique uses a picosecond pulsed laser as well as fast temporal gating of collected Raman...

    journal_title:Journal of biomedical optics

    pub_type: 临床试验,杂志文章

    doi:10.1117/1.1991848

    authors: Prieto MC,Matousek P,Towrie M,Parker AW,Wright M,Ritchie AW,Stone N

    更新日期:2005-07-01 00:00:00

  • Quantitative analysis of angle-resolved scattering properties of ovarian tissue using optical coherence tomography.

    abstract::Angle-resolved optical scattering properties of ovarian tissue, on different optical coherence tomography (OCT) imaging planes, were quantitatively measured by fitting the compounded OCT A-lines into a single scattering model. Higher cross correlation value of angle-resolved scattering coefficients between different O...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.17.9.090503

    authors: Yang Y,Wang T,Brewer M,Zhu Q

    更新日期:2012-09-01 00:00:00

  • Magnetic resonance imaging guidance for laser photothermal therapy.

    abstract::Temperature distribution is a crucial factor in determining the outcome of laser phototherapy in cancer treatment. Magnetic resonance imaging (MRI) is an ideal method for 3-D noninvasive temperature measurement. A 7.1-T MRI was used to determine laser-induced high thermal gradient temperature distribution of target ti...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2960020

    authors: Chen Y,Gnyawali SC,Wu F,Liu H,Tesiram YA,Abbott A,Towner RA,Chen WR

    更新日期:2008-07-01 00:00:00

  • Screening for the breast cancer gene (BRCA1) using a biochip system and molecular beacon probes immobilized on solid surfaces.

    abstract::We describe the use of a biochip based on complementary metal oxide semiconductor (CMOS) technology for detection of specific genetic sequences using molecular beacons (MB) immobilized on solid surfaces as probes. The applicability of this miniature detection system for screening for the BRCA1 gene is evaluated using ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1691025

    authors: Culha M,Stokes DL,Griffin GD,Vo-Dinh T

    更新日期:2004-05-01 00:00:00

  • Quantification of in vivo fluorescence decoupled from the effects of tissue optical properties using fiber-optic spectroscopy measurements.

    abstract::We present a method for tissue fluorescence quantification in situ using a handheld fiber optic probe that measures both the fluorescence and diffuse reflectance spectra. A simplified method to decouple the fluorescence spectrum from distorting effects of the tissue optical absorption and scattering is developed, with...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3523616

    authors: Kim A,Khurana M,Moriyama Y,Wilson BC

    更新日期:2010-11-01 00:00:00

  • Stress Relaxation of Porcine Septal Cartilage During Nd:YAG (λ=1.32 μm) Laser Irradiation: Mechanical, Optical, and Thermal Responses.

    abstract::Laser-assisted cartilage reshaping is mediated by thermally induced stress relaxation, and may be used to alter cartilage morphology for reconstructive surgical procedures in the upper airway and face without carving, morselizing, or suturing. Internal stress σ(t), integrated backscattered light intensity I(t) from a ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429896

    authors: Wong BJ,Milner TE,Kim HH,Stuart Nelson J,Sobol EN

    更新日期:1998-10-01 00:00:00

  • Comparison of time-resolved and continuous-wave near-infrared techniques for measuring cerebral blood flow in piglets.

    abstract::A primary focus of neurointensive care is monitoring the injured brain to detect harmful events that can impair cerebral blood flow (CBF), resulting in further injury. Since current noninvasive methods used in the clinic can only assess blood flow indirectly, the goal of this research is to develop an optical techniqu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3488626

    authors: Diop M,Tichauer KM,Elliott JT,Migueis M,Lee TY,St Lawrence K

    更新日期:2010-09-01 00:00:00

  • Control of cardiomyocyte orientation on a microscaffold fabricated by photopolymerization with laser beam interference.

    abstract::We fabricate scaffolds with a fine linear grating (periodicity of 1 to 8 microm and height of 1 microm) on a glass substrate for controlling cardiomyocyte orientation. The fabrication is done by the solidification of a liquid photopolymerizable material using two laser beam interference. As the photopolymerizable mate...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2186042

    authors: Fujita A,Fujita K,Nakamura O,Matsuda T,Kawata S

    更新日期:2006-03-01 00:00:00

  • Parameters affecting ultrafast laser microsurgery of subepithelial voids for scar treatment in vocal folds.

    abstract::Toward developing a new method for restoring tissue viscoelasticity in scarred vocal folds, we previously proposed a method to localize biomaterials within subepithelial voids ablated using ultrafast laser pulses. The clinical implementation of this method necessitates the quantification of the laser parameters for ab...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.11.118001

    authors: Yildirim M,Ferhanoglu O,Kobler J,Zeitels SM,Ben-Yakar A

    更新日期:2013-11-01 00:00:00

  • Understanding three-dimensional spatial relationship between the mouse second polar body and first cleavage plane with full-field optical coherence tomography.

    abstract::The morphogenetic relationship between early patterning and polarity formation is of fundamental interest and remains a controversial issue in preimplantation embryonic development. We use a label-free three-dimensional (3-D) imaging technique of full-field optical coherence tomography (FF-OCT) successfully for the fi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.1.010503

    authors: Zheng JG,Huo T,Chen T,Wang C,Zhang N,Tian N,Zhao F,Lu D,Chen D,Ma W,Sun JL,Xue P

    更新日期:2013-01-01 00:00:00

  • Multispectral in vivo three-dimensional optical coherence tomography of human skin.

    abstract::The capability of optical coherence tomography (OCT) to perform "optical biopsy" of tissues within a depth range of 1 to 2 mm with micron-scale resolution in real time makes it a promising biomedical imaging modality for dermatologic applications. Three high-speed, spectrometer-based frequency-domain OCT systems opera...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3400665

    authors: Alex A,Povazay B,Hofer B,Popov S,Glittenberg C,Binder S,Drexler W

    更新日期:2010-03-01 00:00:00