Comparison of spectroscopically measured tissue alcohol concentration to blood and breath alcohol measurements.

Abstract:

:Alcohol testing is an expanding area of interest due to the impacts of alcohol abuse that extend well beyond drunk driving. However, existing approaches such as blood and urine assays are hampered in some testing environments by biohazard risks. A noninvasive, in vivo spectroscopic technique offers a promising alternative, as no body fluids are required. The purpose of this work is to report the results of a 36-subject clinical study designed to characterize tissue alcohol measured using near-infrared spectroscopy relative to venous blood, capillary blood, and breath alcohol. Comparison of blood and breath alcohol concentrations demonstrated significant differences in alcohol concentration [root mean square of 9.0 to 13.5 mg/dL] that were attributable to both assay accuracy and precision as well as alcohol pharmacokinetics. A first-order kinetic model was used to estimate the contribution of alcohol pharmacokinetics to the differences in concentration observed between the blood, breath, and tissue assays. All pair-wise combinations of alcohol assays were investigated, and the fraction of the alcohol concentration variance explained by pharmacokinetics ranged from 41.0% to 83.5%. Accounting for pharmacokinetic concentration differences, the accuracy and precision of the spectroscopic tissue assay were found to be comparable to those of the blood and breath assays.

journal_name

J Biomed Opt

authors

Ridder TD,Ver Steeg BJ,Laaksonen BD

doi

10.1117/1.3253353

subject

Has Abstract

pub_date

2009-09-01 00:00:00

pages

054039

issue

5

eissn

1083-3668

issn

1560-2281

journal_volume

14

pub_type

杂志文章
  • Development of single-channel optical video stereomicroscopy.

    abstract::This study introduces a single-channel optical video stereomicroscope based on a transparent rotating deflector (TRD) for high-resolution and high-magnification stereomicroscopy. The existing stereomicroscopes have some limitations, such as limited resolution and magnification, fixed optical channel, and the necessity...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.126001

    authors: Radfar E,Park J,Jung B

    更新日期:2016-12-01 00:00:00

  • Real-time intraoperative fluorescence imaging system using light-absorption correction.

    abstract::We present a novel fluorescence imaging system developed for real-time interventional imaging applications. The system implements a correction scheme that improves the accuracy of epi-illumination fluorescence images for light intensity variation in tissues. The implementation is based on the use of three cameras oper...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3259362

    authors: Themelis G,Yoo JS,Soh KS,Schulz R,Ntziachristos V

    更新日期:2009-11-01 00:00:00

  • Quantification of fiber orientation in the canine atrial pacemaker complex using optical coherence tomography.

    abstract::The atrial pacemaker complex is responsible for the initiation and early propagation of cardiac impulses. Optical coherence tomography (OCT), a nondestructive imaging modality with spatial resolutions of ∼1 to 15 μm, can be used to identify unique fiber orientation patterns in this region of the heart. Functionally ch...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.071309

    authors: Ambrosi CM,Fedorov VV,Schuessler RB,Rollins AM,Efimov IR

    更新日期:2012-07-01 00:00:00

  • Monitoring the reduced scattering coefficient of bone tissues on the trajectory of pedicle screw placement using near-infrared spectroscopy.

    abstract::Pedicle screw (PS) fixation has been widely used for spine diseases. Scientists and clinicians employ several approaches to navigate PS during operation. We have demonstrated the feasibility of monitoring the reduced scattering coefficient (μ's) on the trajectory of PS using near-infrared spectroscopy (NIRS). To perfo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.117002

    authors: Liu Y,Wang Y,Qian Z,Zhao J,Cao X,Li W

    更新日期:2014-01-01 00:00:00

  • In vivo video-rate cellular-level full-field optical coherence tomography.

    abstract::Full-field optical coherence tomography (FF-OCT) capable of in vivo cellular-level imaging is demonstrated for nonscanning horizontal cross-sectional imaging. The system is based on a white light interference microscope illuminated by a thermal light source. A dual-channel two-dimensional (2-D) detection technique inc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2822159

    authors: Akiba M,Chan KP

    更新日期:2007-11-01 00:00:00

  • Infrared spectroscopic imaging of renal tumor tissue.

    abstract::Fourier transform infrared (FTIR) spectroscopic imaging has been used to probe the biochemical composition of human renal tumor tissue and adjacent normal tissue. Freshly resected renal tumor tissue from surgery was prepared as a thin cryosection and examined by FTIR spectroscopic imaging. Tissue types could be discri...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3622292

    authors: Sablinskas V,Urboniene V,Ceponkus J,Laurinavicius A,Dasevicius D,Jankevicius F,Hendrixson V,Koch E,Steiner G

    更新日期:2011-09-01 00:00:00

  • Europium-quantum dot nanobioconjugates as luminescent probes for time-gated biosensing.

    abstract::Nanobioconjugates have been synthesized using cadmium selenide quantum dots (QDs), europium complexes (EuCs), and biotin. In those conjugates, long-lived photoluminescence (PL) is provided by the europium complexes, which efficiently transfer energy via Förster resonance energy transfer (FRET) to the QDs in close spat...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.101506

    authors: Cywinski PJ,Hammann T,Hühn D,Parak WJ,Hildebrandt N,Löhmannsröben HG

    更新日期:2014-01-01 00:00:00

  • Using thermographic cameras to investigate eye temperature and clinical severity in depression.

    abstract::Previous studies suggest that altered corneal temperature may be a feature of schizophrenia, but the association between major depressive disorder (MDD) and corneal temperature has yet to be assessed. The aim of this study is to investigate whether eye temperature is different among MDD patients than among healthy ind...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.2.026001

    authors: Maller JJ,George SS,Viswanathan RP,Fitzgerald PB,Junor P

    更新日期:2016-02-01 00:00:00

  • Noninvasive enhanced mid-IR imaging of breast cancer development in vivo.

    abstract::Lumpectomy coupled with radiation therapy and/or chemotherapy is commonly used to treat breast cancer patients. We are developing an enhanced thermal IR imaging technique that has the potential to provide real-time imaging to guide tissue excision during a lumpectomy by delineating tumor margins. This enhanced thermal...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.11.116003

    authors: Case JR,Young MA,Dréau D,Trammell SR

    更新日期:2015-11-01 00:00:00

  • Modulation transfer function measurement of scanning reflectance microscopes.

    abstract::Real-time medical imaging systems such as reflectance confocal microscopes and optical coherence microscopes are being tested in multiple-patient and multiple-center clinical trials. The modulation transfer function (MTF) of these systems at any given time influences the image information content and can affect the in...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2779352

    authors: Wang Z,Glazowski CE,Zavislan JM

    更新日期:2007-09-01 00:00:00

  • Spatiotemporal laser speckle contrast analysis for blood flow imaging with maximized speckle contrast.

    abstract::Laser speckle contrast imaging is a technique used for imaging blood flow without scanning. Though several studies have attempted to combine spatial and temporal statistics of laser speckle images for reducing image noise as well as preserving acceptable spatiotemporal resolution, the statistical accuracy of these spa...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3290804

    authors: Qiu J,Li P,Luo W,Wang J,Zhang H,Luo Q

    更新日期:2010-01-01 00:00:00

  • Photoacoustic properties of anterior ocular tissues.

    abstract::Clinical imaging techniques for the anterior segment of the eye provide excellent anatomical information, but molecular imaging techniques are lacking. Molecular photoacoustic imaging is one option to address this need, but implementation requires use of contrast agents to distinguish molecular targets from background...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.5.056004

    authors: Kubelick KP,Snider EJ,Ethier CR,Emelianov S

    更新日期:2019-05-01 00:00:00

  • Application of biospeckles for assessment of structural and cellular changes in muscle tissue.

    abstract::A modified spatial-temporal speckle correlation technique for operational assessment of structural changes in muscle tissues after slaughtering is considered. Coefficient of biological activity as a quantitative indicator of structural changes of biochemical processes in biological tissues is proposed. The experimenta...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.9.095006

    authors: Maksymenko OP,Muravsky LI,Berezyuk MI

    更新日期:2015-09-01 00:00:00

  • Screening for the breast cancer gene (BRCA1) using a biochip system and molecular beacon probes immobilized on solid surfaces.

    abstract::We describe the use of a biochip based on complementary metal oxide semiconductor (CMOS) technology for detection of specific genetic sequences using molecular beacons (MB) immobilized on solid surfaces as probes. The applicability of this miniature detection system for screening for the BRCA1 gene is evaluated using ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1691025

    authors: Culha M,Stokes DL,Griffin GD,Vo-Dinh T

    更新日期:2004-05-01 00:00:00

  • Monte Carlo modeling of light propagation in the human head for applications in sinus imaging.

    abstract::Sinus blockages are a common reason for physician visits, affecting one out of seven people in the United States, and often require medical treatment. Diagnosis in the primary care setting is challenging because symptom criteria (via detailed clinical history) plus objective imaging [computed tomography (CT) or endosc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.3.035004

    authors: Cerussi AE,Mishra N,You J,Bhandarkar N,Wong B

    更新日期:2015-03-01 00:00:00

  • Toward the clinical application of time-domain fluorescence lifetime imaging.

    abstract::High-speed (video-rate) fluorescence lifetime imaging (FLIM) through a flexible endoscope is reported based on gated optical image intensifier technology. The optimization and potential application of FLIM to tissue autofluorescence for clinical applications are discussed. ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2102807

    authors: Munro I,McGinty J,Galletly N,Requejo-Isidro J,Lanigan PM,Elson DS,Dunsby C,Neil MA,Lever MJ,Stamp GW,French PM

    更新日期:2005-09-01 00:00:00

  • Pulsed photoacoustic flow imaging with a handheld system.

    abstract::Flow imaging is an important technique in a range of disease areas, but estimating low flow speeds, especially near the walls of blood vessels, remains challenging. Pulsed photoacoustic flow imaging can be an alternative since there is little signal contamination from background tissue with photoacoustic imaging. We p...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.2.026004

    authors: van den Berg PJ,Daoudi K,Steenbergen W

    更新日期:2016-02-01 00:00:00

  • Application of functional data analysis in classification and clustering of functional near-infrared spectroscopy signal in response to noxious stimuli.

    abstract::We introduce the application of functional data analysis (fDA) on functional near-infrared spectroscopy (fNIRS) signals for the development of an accurate and clinically practical assessment method of pain perception. We used the cold pressor test to induce different levels of pain in healthy subjects while the fNIRS ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.10.101411

    authors: Pourshoghi A,Zakeri I,Pourrezaei K

    更新日期:2016-10-01 00:00:00

  • Real-time in vivo photoacoustic and ultrasound imaging.

    abstract::A real-time photoacoustic imaging system is designed and built. This system is based on a commercially available ultrasound imaging system. It can achieve a frame rate of 8 frames/sec. Vasculature in the hand of a human volunteer is imaged, and the resulting photoacoustic image is combined with the ultrasound image. T...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3005421

    authors: Kolkman RG,Brands PJ,Steenbergen W,van Leeuwen TG

    更新日期:2008-09-01 00:00:00

  • Performance assessment of time-domain optical brain imagers, part 2: nEUROPt protocol.

    abstract::The nEUROPt protocol is one of two new protocols developed within the European project nEUROPt to characterize the performances of time-domain systems for optical imaging of the brain. It was applied in joint measurement campaigns to compare the various instruments and to assess the impact of technical improvements. T...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.8.086012

    authors: Wabnitz H,Jelzow A,Mazurenka M,Steinkellner O,Macdonald R,Milej D,Żołek N,Kacprzak M,Sawosz P,Maniewski R,Liebert A,Magazov S,Hebden J,Martelli F,Di Ninni P,Zaccanti G,Torricelli A,Contini D,Re R,Zucchelli L,Spine

    更新日期:2014-08-01 00:00:00

  • Graphics processing unit-based dispersion encoded full-range frequency-domain optical coherence tomography.

    abstract::Dispersion encoded full-range (DEFR) frequency-domain optical coherence tomography (FD-OCT) and its enhanced version, fast DEFR, utilize dispersion mismatch between sample and reference arm to eliminate the ambiguity in OCT signals caused by non-complex valued spectral measurement, thereby numerically doubling the usa...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.077007

    authors: Wang L,Hofer B,Guggenheim JA,Povazay B

    更新日期:2012-07-01 00:00:00

  • Study of cadmium-induced cytotoxicity using two-photon excitation endogenous fluorescence microscopy.

    abstract::We demonstrate that using time-resolved two-photon excitation endogenous fluorescence microscopy, the cadmium (Cd)-induced cellular toxic level can be assessed by the free-to protein-bound reduced nicotinamide adenine dinucleotide (free/bound NADH) ratio in a living cell. NADH fluorescence excited at 730 nm is capture...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3250293

    authors: Li D,Yang MS,Lin T,Zheng W,Qu JY

    更新日期:2009-09-01 00:00:00

  • Influence of phase function on modeled optical response of nanoparticle-labeled epithelial tissues.

    abstract::Metal nanoparticles can be functionalized with biomolecules to selectively localize in precancerous tissues and can act as optical contrast enhancers for reflectance-based diagnosis of epithelial precancer. We carry out Monte Carlo (MC) simulations to analyze photon propagation through nanoparticle-labeled tissues and...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3608999

    authors: Cihan C,Arifler D

    更新日期:2011-08-01 00:00:00

  • Classification of skin moles from optical spectropolarimetric images: a pilot study.

    abstract::A new skin-imaging method, which was developed recently, gives an informative image data about skin moles by collecting scattered polarized light reflected from their tissue area at different wavelengths and polarizations. This method is called as optical rotational spectropolarimetric imaging (ORSI), which scans the ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.11.111403

    authors: Graham L,Yitzhaky Y,Abdulhalim I

    更新日期:2013-11-01 00:00:00

  • Robust single-molecule approach for counting autofluorescent proteins.

    abstract::Using single-molecule microscopy, we present a method to quantify the number of single autofluorescent proteins when they cannot be optically resolved. This method relies on the measurement of the total intensity emitted by each aggregate until it photobleaches. This strategy overcomes the inherent problem of blinking...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2940600

    authors: Cognet L,Tardin C,Négrier ML,Breillat C,Coussen F,Choquet D,Lounis B

    更新日期:2008-05-01 00:00:00

  • Measurement of retinal blood flow in the rat by combining Doppler Fourier-domain optical coherence tomography with fundus imaging.

    abstract::A wide variety of ocular diseases are associated with abnormalities in ocular circulation. As such, there is considerable interest in techniques for quantifying retinal blood flow, among which Doppler optical coherence tomography (OCT) may be the most promising. We present an approach to measure retinal blood flow in ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.106008

    authors: Werkmeister RM,Vietauer M,Knopf C,Fürnsinn C,Leitgeb RA,Reitsamer H,Gröschl M,Garhöfer G,Vilser W,Schmetterer L

    更新日期:2014-01-01 00:00:00

  • "Seeing" electroencephalogram through the skull: imaging prefrontal cortex with fast optical signal.

    abstract::Near-infrared spectroscopy is a novel imaging technique potentially sensitive to both brain hemodynamics (slow signal) and neuronal activity (fast optical signal, FOS). The big challenge of measuring FOS noninvasively lies in the presumably low signal-to-noise ratio. Thus, detectability of the FOS has been controversi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3505007

    authors: Medvedev AV,Kainerstorfer JM,Borisov SV,Gandjbakhche AH,Vanmeter J

    更新日期:2010-11-01 00:00:00

  • Dynamic performance of microelectromechanical systems deformable mirrors for use in an active/adaptive two-photon microscope.

    abstract::Active optics such as deformable mirrors can be used to control both focal depth and aberrations during scanning laser microscopy. If the focal depth can be changed dynamically during scanning, then imaging of oblique surfaces becomes possible. If aberrations can be corrected dynamically during scanning, an image can ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.121507

    authors: Archer-Zhang CC,Foster WB,Downey RD,Arrasmith CL,Dickensheets DL

    更新日期:2016-12-01 00:00:00

  • Volumetric full-range magnetomotive optical coherence tomography.

    abstract::Magnetomotive optical coherence tomography (MM-OCT) can be utilized to spatially localize the presence of magnetic particles within tissues or organs. These magnetic particle-containing regions are detected by using the capability of OCT to measure small-scale displacements induced by the activation of an external ele...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.12.126001

    authors: Ahmad A,Kim J,Shemonski ND,Marjanovic M,Boppart SA

    更新日期:2014-12-01 00:00:00

  • Scattering coefficient determination in turbid media with backscattered polarized light.

    abstract::A simple empirical method is presented to determine the scattering coefficient mu' s from backscattered polarized images of turbid media. It uses the ratio, pixel by pixel, of two images that are the second and the first backscattered Stokes parameter images Q and I, respectively. Taking this image ratio, then integra...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1924715

    authors: Jaillon F,Saint-Jalmes H

    更新日期:2005-05-01 00:00:00