Abstract:
:Metal nanoparticles can be functionalized with biomolecules to selectively localize in precancerous tissues and can act as optical contrast enhancers for reflectance-based diagnosis of epithelial precancer. We carry out Monte Carlo (MC) simulations to analyze photon propagation through nanoparticle-labeled tissues and to reveal the importance of using a proper form of phase function for modeling purposes. We first employ modified phase functions generated with a weighting scheme that accounts for the relative scattering strengths of unlabeled tissue and nanoparticles. To present a comparative analysis, we repeat our MC simulations with simplified functions that only approximate the angular scattering properties of labeled tissues. The results obtained for common optical sensor geometries and biologically relevant labeling schemes indicate that the exact form of the phase function used as model input plays an important role in determining the reflectance response and approximating functions often prove inadequate in predicting the extent of contrast enhancement due to labeling. Detected reflectance intensities computed with different phase functions can differ up to ∼60% and such a significant deviation may even alter the perceived contrast profile. These results need to be taken into account when developing photon propagation models to assess the diagnostic potential of nanoparticle-enhanced optical measurements.
journal_name
J Biomed Optjournal_title
Journal of biomedical opticsauthors
Cihan C,Arifler Ddoi
10.1117/1.3608999subject
Has Abstractpub_date
2011-08-01 00:00:00pages
085002issue
8eissn
1083-3668issn
1560-2281journal_volume
16pub_type
杂志文章abstract::Color Doppler optical coherence tomography (CDOCT) is a functional extension of optical coherence tomography (OCT) that can image flow in turbid media. We have developed a CDOCT system capable of imaging flow in real time. Doppler processing of the analog signal is accomplished in hardware in the time domain using a n...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1428291
更新日期:2002-01-01 00:00:00
abstract::Image correlation spectroscopy (ICS) is a powerful technique for detecting arrangement of fluorophores in images. This tutorial gives background into the mathematical underpinnings of ICS, specifically image autocorrelation. The effects of various artifacts and image processing steps, including background subtraction,...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.17.8.080801
更新日期:2012-08-01 00:00:00
abstract::Near-infrared diffuse optical tomography (DOT), one of the most sophisticated optical imaging techniques for observations through biological tissue, allows 3-D quantitative imaging of optical properties, which include functional and anatomical information. With DOT, it is expected to be possible to overcome the limita...
journal_title:Journal of biomedical optics
pub_type: 杂志文章,评审
doi:10.1117/1.JBO.21.9.091312
更新日期:2016-09-01 00:00:00
abstract::Hyperspectral reflectance imaging technique has been used for in vivo detection of cervical intraepithelial neoplasia. However, the clinical outcome of this technique is suboptimal owing to multiple limitations such as nonuniform illumination, high-cost and bulky setup, and time-consuming data acquisition and processi...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.12.121303
更新日期:2015-12-01 00:00:00
abstract::Resin embedding is widely used and facilitates microscopic imaging of biological tissues. In contrast, quenching of fluorescence during embedding process hinders the application of resin embedding for imaging of fluorescence-labeled samples. For samples expressing fluorescent proteins, it has been demonstrated that th...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.23.2.020501
更新日期:2018-02-01 00:00:00
abstract:SIGNIFICANCE:A noninvasive method based on surface-enhanced Raman spectroscopy (SERS) of tears was proposed as a support for diagnosing neurodegenerative pathologies, including different forms of dementia and Alzheimer's disease (AD). In this field, timely and reliable discrimination and diagnosis are critical aspects ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.25.8.087002
更新日期:2020-08-01 00:00:00
abstract::Current diagnostic capabilities and limitations of fluorescence endomicroscopy in the cervix are assessed by qualitative and quantitative image analysis. Four cervical tissue types are investigated: normal columnar epithelium, normal and precancerous squamous epithelium, and stromal tissue. This study focuses on the p...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.12.126011
更新日期:2016-12-01 00:00:00
abstract::We describe a wide-field optical tomography technique, which allows the measurement-guided optimization of illumination patterns for enhanced reconstruction performances. The iterative optimization of the excitation pattern aims at reducing the dynamic range in photons transmitted through biological tissue. It increas...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.3.036006
更新日期:2013-03-01 00:00:00
abstract::Fluorescence Talbot microscope is a scalable field-of-view (FOV) imaging platform, which takes advantage of the phase sensitivity of the self-image of a periodic structure. Such a system can maintain the microscopic resolution and extend the FOV for the whole slide (15 mm×15 mm) scanning. Previously reported Talbot ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.8.086003
更新日期:2016-08-01 00:00:00
abstract::Environmental metastability of zirconia (ZrO2) ceramic in the human body [represented by a tetragonal-to-monoclinic (t→m) phase transformation] takes place on the surface of the artificial joint and proceeds with time toward its interior. Its quantitative characterization is mandatory for the safety of joint implants ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.12.127002
更新日期:2013-12-01 00:00:00
abstract::Blood pulse wave velocity (PWV) is an important physiological parameter that characterizes vascular stiffness. In this letter, we present electrocardiogram-synchronized, photoacoustic microscopy for noninvasive quantification of the PWV in the peripheral vessels of living mice. Interestingly, blood pulse wave-induced ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.17.7.070504
更新日期:2012-07-01 00:00:00
abstract::In a previous study, we investigated physical methods to reduce whole-body, diet-related autofluorescence interference in several mouse strains through changes in animal diet. Measurements of mice with an in vivo multispectral imaging system over a 21-day period allowed for the quantification of concentration changes ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2799188
更新日期:2007-09-01 00:00:00
abstract::Previous research correcting for variable speed of sound in photoacoustic tomography (PAT) based on a generalized radon transform (GRT) model assumes first-order geometrical acoustics (GA) approximation. In the GRT model, the pressure is related to the optical absorption, in an acoustically inhomogeneous medium, throu...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3333550
更新日期:2010-03-01 00:00:00
abstract::Reduction of optical scattering in turbid biological tissues using nonreactive chemical agents has potential applications for light-based diagnostics and therapeutics. Optical clearing effects by exogenous chemical agents, in particular sugars and sugar alcohols, have been found to be temporary with tissue rehydration...
journal_title:Journal of biomedical optics
pub_type: 杂志文章,评审
doi:10.1117/1.2166381
更新日期:2006-01-01 00:00:00
abstract::A new, simple, high-speed, and hardware-only integration-based fluorescence-lifetime-sensing algorithm using a center-of-mass method (CMM) is proposed to implement lifetime calculations, and its signal-to-noise-ratio based on statistics theory is also deduced. Compared to the commonly used iterative least-squares meth...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3309737
更新日期:2010-01-01 00:00:00
abstract::A reflectance volume holographic imaging (VHI) endoscope has been designed for simultaneous in vivo imaging of surface and subsurface tissue structures. Prior utilization of VHI systems has been limited to ex vivo tissue imaging. The VHI system presented in this work is designed for laparoscopic use. It consists of a ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.22.5.056010
更新日期:2017-05-01 00:00:00
abstract::We demonstrate the ex vivo imaging of an oral cancerous sample with a swept-source optical coherence tomography (SS-OCT) system. With the axial resolution of 8 microm in free space and system sensitivity of 108 dB, we can well distinguish the normal and abnormal tissue portions in a sample. In particular, we analyze t...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2960632
更新日期:2008-07-01 00:00:00
abstract::The refractive index of blood is a key biophysical parameter, which can reflect the physiological state. We measured the refractive index of whole blood and other components, such as serum, plasma, and hemoglobin, based on internal reflection by using a homemade apparatus in the spectral range of 400 to 750 nm. In add...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.24.3.035003
更新日期:2019-03-01 00:00:00
abstract::Previous studies suggest that altered corneal temperature may be a feature of schizophrenia, but the association between major depressive disorder (MDD) and corneal temperature has yet to be assessed. The aim of this study is to investigate whether eye temperature is different among MDD patients than among healthy ind...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.2.026001
更新日期:2016-02-01 00:00:00
abstract::We report a photonic approach for selective inactivation of viruses with a near-infrared subpicosecond laser. We demonstrate that this method can selectively inactivate viral particles ranging from nonpathogenic viruses such as the M13 bacteriophage and the tobacco mosaic virus to pathogenic viruses such as the human ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3275477
更新日期:2009-11-01 00:00:00
abstract::Ultrasmall scale implants have recently attracted focus as valuable tools for monitoring both acute and chronic diseases. Semiconductor optical technologies are the key to miniaturizing these devices to the long-sought sub-mm scale, which will enable long-term use of these devices for medical applications. This can al...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.9.095012
更新日期:2015-09-01 00:00:00
abstract::Optical coherence tomography (OCT) provides more parameters than pure morphology does. In a recent paper [A. Knuettel and M. Boehlau-Godau, J. Biomed. Opt. 5(1) 83-92 (2000)] we have shown that the refractive index (RI) can be evaluated in a localized manner in skin tissue under in vivo conditions. Based on a theory, ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1647544
更新日期:2004-03-01 00:00:00
abstract::Real-time medical imaging systems such as reflectance confocal microscopes and optical coherence microscopes are being tested in multiple-patient and multiple-center clinical trials. The modulation transfer function (MTF) of these systems at any given time influences the image information content and can affect the in...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2779352
更新日期:2007-09-01 00:00:00
abstract::Radiotherapy is one of the main methods to treat cancer. However, due to the propagation pattern of high-energy photons in tissue and their inability to discriminate between healthy and malignant tissues, healthy tissues may also be damaged, causing undesired side effects. A possible method for internal electron thera...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.5.051041
更新日期:2015-05-01 00:00:00
abstract::We develop a label-free optical technique to image and discriminate undifferentiated human embryonic stem cells (hESCs) from their differentiating progenies in vitro. Using intrinsic cellular fluorophores, we perform fluorescence lifetime microscopy (FLIM) and phasor analysis to obtain hESC metabolic signatures. We id...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.17.4.046012
更新日期:2012-04-01 00:00:00
abstract::A side-viewing, 2.3-mm diameter, surface magnifying chromoendoscopy-optical coherence tomography (SMC-OCT) endoscope has been designed for simultaneous, nondestructive surface fluorescence visualization and cross-sectional imaging. We apply this endoscope to in vivo examination of the mouse colon. A 30,000 element fib...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.17.8.086003
更新日期:2012-08-01 00:00:00
abstract::The fibrillar collagen network in tumor and normal tissues is different due to remodeling of the extracellular matrix during the malignant process. Collagen type I fibers have the crystalline and noncentrosymmetric properties required for generating the second-harmonic signal. The content and structure of collagen wer...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2983664
更新日期:2008-09-01 00:00:00
abstract::Noninvasive cardiovascular imaging could lead to the early detection and timely treatment of complex atherosclerotic lesions responsible for major cardiovascular events. Recent investigations have suggested that optical coherence tomography (OCT) is an ideal diagnostic tool due to the high resolution this technology a...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2870153
更新日期:2008-01-01 00:00:00
abstract::In this study we examine the implications of excitation saturation on fluorescence recovery after photobleaching (FRAP) experiments. In particular we present both experimental and theoretical evidence that fluorescein, one of the most frequently used fluorophores in FRAP, does not always comply with the basic assumpti...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2337531
更新日期:2006-07-01 00:00:00
abstract::Complete and continuous imaging of microvascular networks is crucial for a wide variety of biomedical applications. Photoacoustic tomography can provide high resolution microvascular imaging using hemoglobin within red blood cells (RBCs) as an endogenic contrast agent. However, intermittent RBC flow in capillaries res...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3251044
更新日期:2009-09-01 00:00:00