Dynamic performance of microelectromechanical systems deformable mirrors for use in an active/adaptive two-photon microscope.

Abstract:

:Active optics such as deformable mirrors can be used to control both focal depth and aberrations during scanning laser microscopy. If the focal depth can be changed dynamically during scanning, then imaging of oblique surfaces becomes possible. If aberrations can be corrected dynamically during scanning, an image can be optimized throughout the field of view. Here, we characterize the speed and dynamic precision of a Boston Micromachines Corporation Multi-DM 140 element aberration correction mirror and a Revibro Optics 4-zone focus control mirror to assess suitability for use in an active and adaptive two-photon microscope. Tests for the multi-DM include both step response and sinusoidal frequency sweeps of specific Zernike modes (defocus, spherical aberration, coma, astigmatism, and trefoil). We find wavefront error settling times for mode amplitude steps as large as 400 nm to be less than 52???s, with 3 dB frequencies ranging from 6.5 to 10 kHz. The Revibro Optics mirror was tested for step response only, with wavefront error settling time less than 80???s for defocus steps up to 3000 nm, and less than 45???s for spherical aberration steps up to 600 nm. These response speeds are sufficient for intrascan correction at scan rates typical of two-photon microscopy.

journal_name

J Biomed Opt

authors

Archer-Zhang CC,Foster WB,Downey RD,Arrasmith CL,Dickensheets DL

doi

10.1117/1.JBO.21.12.121507

subject

Has Abstract

pub_date

2016-12-01 00:00:00

pages

121507

issue

12

eissn

1083-3668

issn

1560-2281

pii

2569558

journal_volume

21

pub_type

杂志文章
  • Photoacoustic microscopy of blood pulse wave.

    abstract::Blood pulse wave velocity (PWV) is an important physiological parameter that characterizes vascular stiffness. In this letter, we present electrocardiogram-synchronized, photoacoustic microscopy for noninvasive quantification of the PWV in the peripheral vessels of living mice. Interestingly, blood pulse wave-induced ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.070504

    authors: Yeh C,Hu S,Maslov K,Wang LV

    更新日期:2012-07-01 00:00:00

  • Super-resolution photoacoustic microscopy using photonic nanojets: a simulation study.

    abstract::Optical resolution photoacoustic microscopy (ORPAM) is important for various biomedical applications, such as the study of cellular structures, microcirculation systems, and tumor angiogenesis. However, the lateral resolution of a conventional ORPAM is limited by optical diffraction. In this work, we report a simulati...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.116003

    authors: Upputuri PK,Wen ZB,Wu Z,Pramanik M

    更新日期:2014-01-01 00:00:00

  • Near-infrared transmittance pulse oximetry with laser diodes.

    abstract::Pulse oximeters are widely used for noninvasive monitoring of oxygen saturation in arterial blood hemoglobin. We present a transmittance pulse oximetry system based on near-infrared (NIR) laser diodes (750 and 850 nm) for monitoring oxygen saturation of arterial blood hemoglobin. The pulse oximetry system is made up o...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1578495

    authors: Lopez Silva SM,Dotor Castilla ML,Silveira Martin JP

    更新日期:2003-07-01 00:00:00

  • Parallel two-channel near- and far-field fluorescence microscopy.

    abstract::We report a new two-channel fluorescence microscopy technique for surface-generated fluorescence. The realized fluorescence microscope allows high resolution imaging of aqueous samples. The core element of the instrument is a parabolic mirror objective that is used to collect the fluorescence at large surface angles a...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2747627

    authors: Verdes D,Ruckstuhl T,Seeger S

    更新日期:2007-05-01 00:00:00

  • Combined anatomical optical coherence tomography and intraluminal pressure reveal viscoelasticity of the in vivo airway.

    abstract::It is hypothesized that the local, viscoelastic (time-dependent) properties of the airway are important to accurately model and ultimately predict dynamic airway collapse in airway obstruction. Toward this end, we present a portable, endoscopic, swept-source anatomical optical coherence tomography (aOCT) system combin...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.23.10.100501

    authors: Balakrishnan S,Bu R,Iftimia N,Price H,Zdanski C,Oldenburg AL

    更新日期:2018-10-01 00:00:00

  • Characterization of novel microsphere chain fiber optic tips for potential use in ophthalmic laser surgery.

    abstract::Ophthalmic surgery may benefit from use of more precise fiber delivery systems during laser surgery. Some current ophthalmic surgical techniques rely on tedious mechanical dissection of tissue layers. In this study, chains of sapphire microspheres integrated into a hollow waveguide distal tip are used for erbium:YAG l...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.6.068004

    authors: Hutchens TC,Darafsheh A,Fardad A,Antoszyk AN,Ying HS,Astratov VN,Fried NM

    更新日期:2012-06-01 00:00:00

  • Coregistered photoacoustic and ultrasound imaging and classification of ovarian cancer: ex vivo and in vivo studies.

    abstract::Most ovarian cancers are diagnosed at advanced stages due to the lack of efficacious screening techniques. Photoacoustic tomography (PAT) has a potential to image tumor angiogenesis and detect early neovascular changes of the ovary. We have developed a coregistered PAT and ultrasound (US) prototype system for real-tim...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.4.046006

    authors: Salehi HS,Li H,Merkulov A,Kumavor PD,Vavadi H,Sanders M,Kueck A,Brewer MA,Zhu Q

    更新日期:2016-04-30 00:00:00

  • Amending of fluorescence sensor signal localization in human skin by matching of the refractive index.

    abstract::Fluorescence diagnostic techniques are notable amongst many other optical methods because they offer high sensitivity and noninvasive measurement of tissue properties. However, a combination of multiple scattering and physical heterogeneity of biological tissues hampers interpretation of the fluorescence measurements....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1645796

    authors: Churmakov DY,Meglinski IV,Greenhalgh DA

    更新日期:2004-03-01 00:00:00

  • Graphics processing unit-based dispersion encoded full-range frequency-domain optical coherence tomography.

    abstract::Dispersion encoded full-range (DEFR) frequency-domain optical coherence tomography (FD-OCT) and its enhanced version, fast DEFR, utilize dispersion mismatch between sample and reference arm to eliminate the ambiguity in OCT signals caused by non-complex valued spectral measurement, thereby numerically doubling the usa...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.077007

    authors: Wang L,Hofer B,Guggenheim JA,Povazay B

    更新日期:2012-07-01 00:00:00

  • Intravascular near-infrared fluorescence catheter with ultrasound guidance and blood attenuation correction.

    abstract::Intravascular near-infrared fluorescence (NIRF) imaging offers a new approach for characterizing atherosclerotic plaque, but random catheter positioning within the vessel lumen results in variable light attenuation and can yield inaccurate measurements. We hypothesized that NIRF measurements could be corrected for var...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.5.056009

    authors: Dixon AJ,Hossack JA

    更新日期:2013-05-01 00:00:00

  • Doppler optical microangiography improves the quantification of local fluid flow and shear stress within 3-D porous constructs.

    abstract::Traditional phase-resolved Doppler optical coherence tomography (DOCT) has been reported to have potential for characterizing local fluid flow within a microporous scaffold. In this work, we apply Doppler optical microangiography (DOMAG), a new imaging technique developed by combining optical microangiography (OMAG) w...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3233590

    authors: Jia Y,An L,Wang RK

    更新日期:2009-09-01 00:00:00

  • Shear wave elastography using amplitude-modulated acoustic radiation force and phase-sensitive optical coherence tomography.

    abstract::Investigating the elasticity of ocular tissue (cornea and intraocular lens) could help the understanding and management of pathologies related to biomechanical deficiency. In previous studies, we introduced a setup based on optical coherence tomography for shear wave elastography (SWE) with high resolution and high se...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.1.016001

    authors: Nguyen TM,Arnal B,Song S,Huang Z,Wang RK,O'Donnell M

    更新日期:2015-01-01 00:00:00

  • Protein conformation and molecular order probed by second-harmonic-generation microscopy.

    abstract::Second-harmonic-generation (SHG) microscopy has emerged as a powerful tool to image unstained living tissues and probe their molecular and supramolecular organization. In this article, we review the physical basis of SHG, highlighting how coherent summation of second-harmonic response leads to the sensitivity of polar...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.17.6.060901

    authors: Vanzi F,Sacconi L,Cicchi R,Pavone FS

    更新日期:2012-06-01 00:00:00

  • Cortical spreading depression produces long-term disruption of activity-related changes in cerebral blood volume and neurovascular coupling.

    abstract::Cortical spreading depression (CSD) is a pronounced depolarization of neurons and glia that spreads slowly across the cortex followed by a period of depressed electrophysiological activity. The vascular changes associated with CSD are a large transient increase in blood flow followed by a prolonged decrease lasting gr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1852556

    authors: Guiou M,Sheth S,Nemoto M,Walker M,Pouratian N,Ba A,Toga AW

    更新日期:2005-01-01 00:00:00

  • Effect of probe pressure on cervical fluorescence spectroscopy measurements.

    abstract::Fluorescence spectroscopy is a promising technology for detection of epithelial precancers and cancers. While age and menopausal status influence measurements in the cervix, other variables do not significantly affect the diagnosis. In this study we examine probe pressure as a variable. A fiber optic probe to measure ...

    journal_title:Journal of biomedical optics

    pub_type: 临床试验,杂志文章

    doi:10.1117/1.1695562

    authors: Nath A,Rivoire K,Chang S,Cox D,Atkinson EN,Follen M,Richards-Kortum R

    更新日期:2004-05-01 00:00:00

  • Toward optical guidance during endoscopic ultrasound-guided fine needle aspirations of pancreatic masses using single fiber reflectance spectroscopy: a feasibility study.

    abstract::Endoscopic ultrasound-guided fine needle aspirations (EUS-FNA) of pancreatic masses suffer from sample errors and low-negative predictive values. Fiber-optic spectroscopy in the visible to near-infrared wavelength spectrum can noninvasively extract physiological parameters from tissue and has the potential to guide th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.2.024001

    authors: Stegehuis PL,Boogerd LS,Inderson A,Veenendaal RA,van Gerven P,Bonsing BA,Sven Mieog J,Amelink A,Veselic M,Morreau H,van de Velde CJ,Lelieveldt BP,Dijkstra J,Robinson DJ,Vahrmeijer AL

    更新日期:2017-02-01 00:00:00

  • Pulse-modulated second harmonic imaging microscope quantitatively demonstrates marked increase of collagen in tumor after chemotherapy.

    abstract::Pulse-modulated second harmonic imaging microscopes (PM-SHIMs) exhibit improved signal-to-noise ratio (SNR) over conventional SHIMs on sensitive imaging and quantification of weak collagen signals inside tissues. We quantify the spatial distribution of sparse collagen inside a xenograft model of human acute myeloid le...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3497565

    authors: Raja AM,Xu S,Sun W,Zhou J,Tai DC,Chen CS,Rajapakse JC,So PT,Yu H

    更新日期:2010-09-01 00:00:00

  • Quantitative real-time optical imaging of the tissue metabolic rate of oxygen consumption.

    abstract::The tissue metabolic rate of oxygen consumption (tMRO2) is a clinically relevant marker for a number of pathologies including cancer and arterial occlusive disease. We present and validate a noncontact method for quantitatively mapping tMRO2 over a wide, scalable field of view at 16  frames  /  s. We achieve this by d...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.3.036013

    authors: Ghijsen M,Lentsch GR,Gioux S,Brenner M,Durkin AJ,Choi B,Tromberg BJ

    更新日期:2018-03-01 00:00:00

  • Extraction of optical properties and prediction of light distribution in rat brain tissue.

    abstract::Predicting the distribution of light inside any turbid media, such as biological tissue, requires detailed information about the optical properties of the medium, including the absorption and scattering coefficients and the anisotropy factor. Particularly, in biophotonic applications where photons directly interact wi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.7.075001

    authors: Azimipour M,Baumgartner R,Liu Y,Jacques SL,Eliceiri K,Pashaie R

    更新日期:2014-01-01 00:00:00

  • Imaging caries lesions and lesion progression with polarization sensitive optical coherence tomography.

    abstract::New diagnostic tools are needed for the characterization of dental caries in the early stages of development. If carious lesions are detected early enough, they can be arrested without the need for surgical intervention. The objective of this study was to demonstrate that polarization sensitive optical coherence tomog...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1509752

    authors: Fried D,Xie J,Shafi S,Featherstone JD,Breunig TM,Le C

    更新日期:2002-10-01 00:00:00

  • Fluidic lens laparoscopic zoom camera for minimally invasive surgery.

    abstract::This work reports a miniaturized laparoscopic zoom camera that can significantly improve vision for minimally invasive surgery (MIS), also known as laparoscopic surgery. The laparoscopic zoom camera contains bioinspired fluidic lenses that can change curvature and focal length in a manner similar to the crystalline le...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3420192

    authors: Tsai FS,Johnson D,Francis CS,Cho SH,Qiao W,Arianpour A,Mintz Y,Horgan S,Talamini M,Lo YH

    更新日期:2010-05-01 00:00:00

  • Detrended fluctuation analysis of membrane flickering in discocyte and spherocyte red blood cells using quantitative phase microscopy.

    abstract::Dynamic analyses of vibrational motion in cell membranes provide a lot of information on the complex dynamic motilities of a red blood cell (RBC). Here, we present the correlation properties of membrane fluctuation in discocyte and spherocyte RBCs by using quantitative phase microscopy (QPM). Since QPM can provide nan...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3601460

    authors: Lee S,Lee JY,Park CS,Kim DY

    更新日期:2011-07-01 00:00:00

  • Real-time brightfield, darkfield, and phase contrast imaging in a light-emitting diode array microscope.

    abstract::We demonstrate a single-camera imaging system that can simultaneously acquire brightfield, darkfield, and phase contrast images in real time. Our method uses computational illumination via a programmable light-emitting diode (LED) array at the source plane, providing flexible patterning of illumination angles. Brightf...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.106002

    authors: Liu Z,Tian L,Liu S,Waller L

    更新日期:2014-01-01 00:00:00

  • Optical delivery of liposome encapsulated chemical stimuli to neuronal cells.

    abstract::Spatially confined and precise time delivery of neuroactive molecules is an important issue in neurophysiology. In this work we developed a technique for delivering chemical stimuli to cultured neurons consisting in encapsulating the molecules of interest in liposomes. These vectors were then loaded in reservoirs cons...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3616133

    authors: Pinato G,Raffaelli T,D'Este E,Tavano F,Cojoc D

    更新日期:2011-09-01 00:00:00

  • Bipolar cellular morphology of malignant melanoma in unstained human melanoma skin tissue.

    abstract::Microstructures of unstained human melanoma skin tissues have been examined by multimodal nonlinear optical microscopy. The polarized shape of the individual melanoma cell can be readily recognized-a phenotype that has been identified in laboratory cultures as characteristic of proliferating melanocytes but has not be...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3120491

    authors: Zhang K,Zhang W,Yang CY,Yang H

    更新日期:2009-03-01 00:00:00

  • Coregistered optical coherence tomography and frequency-encoded multispectral imaging for spectrally sparse color imaging.

    abstract::We present a system combining optical coherence tomography (OCT) and multispectral imaging (MSI) for coregistered structural imaging and surface color imaging. We first describe and numerically validate an optimization model to guide the selection of the MSI wavelengths and their relative intensities. We then demonstr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.3.032008

    authors: Attendu X,Bourget MH,de Sivry-Houle MP,Boudoux C

    更新日期:2019-11-01 00:00:00

  • Using thermographic cameras to investigate eye temperature and clinical severity in depression.

    abstract::Previous studies suggest that altered corneal temperature may be a feature of schizophrenia, but the association between major depressive disorder (MDD) and corneal temperature has yet to be assessed. The aim of this study is to investigate whether eye temperature is different among MDD patients than among healthy ind...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.2.026001

    authors: Maller JJ,George SS,Viswanathan RP,Fitzgerald PB,Junor P

    更新日期:2016-02-01 00:00:00

  • Real-time intraoperative fluorescence imaging system using light-absorption correction.

    abstract::We present a novel fluorescence imaging system developed for real-time interventional imaging applications. The system implements a correction scheme that improves the accuracy of epi-illumination fluorescence images for light intensity variation in tissues. The implementation is based on the use of three cameras oper...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3259362

    authors: Themelis G,Yoo JS,Soh KS,Schulz R,Ntziachristos V

    更新日期:2009-11-01 00:00:00

  • Characterization of natural and irradiated nails by means of the depolarization metrics.

    abstract::Mueller polarimetry is applied to study the samples of nails: natural (or reference) and irradiated to 2 Gy ionizing radiation dose. We measure the whole Mueller matrices of the samples as a function of the scattering angle at a wavelength of 632.8 nm. We apply depolarization analysis to measured Mueller matrices by c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.7.071108

    authors: Savenkov S,Priezzhev A,Oberemok Y,Sholom S,Kolomiets I,Chunikhina K

    更新日期:2016-07-01 00:00:00

  • Time-resolved imaging of optical coefficients through murine chest cavities.

    abstract::As small animal optical imaging and tomography are gaining popularity for interrogating functional and molecular events in vivo, it becomes increasingly necessary to gain knowledge of the optical properties of the species investigated to better understand and describe photon propagation through their tissues. To achie...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2400702

    authors: Niedre MJ,Turner GM,Ntziachristos V

    更新日期:2006-11-01 00:00:00