Detrended fluctuation analysis of membrane flickering in discocyte and spherocyte red blood cells using quantitative phase microscopy.

Abstract:

:Dynamic analyses of vibrational motion in cell membranes provide a lot of information on the complex dynamic motilities of a red blood cell (RBC). Here, we present the correlation properties of membrane fluctuation in discocyte and spherocyte RBCs by using quantitative phase microscopy (QPM). Since QPM can provide nanometer sensitivity in thickness measurement within a millisecond time scale, we were able to observe the membrane flicking of an RBC in nanometer resolution up to the bandwidth of 50 Hz. The correlation properties of the vibrational motion were analyzed with the detrended fluctuation analysis (DFA) method. Fractal scaling exponent α in the DFA method was calculated for the vibrational motion of a cell surface at various surface points for normal discocyte and abnormal spherocyte RBCs. Measured α values for normal RBCs are distributed between 0.7 and 1.0, whereas those for abnormal spherocyte RBCs are within a range from 0.85 to 1.2. We have also verified that the vibrational motion of background fluid outside of a cell has an α value close to 0.5, which is a typical property of an uncorrelated white noise.

journal_name

J Biomed Opt

authors

Lee S,Lee JY,Park CS,Kim DY

doi

10.1117/1.3601460

subject

Has Abstract

pub_date

2011-07-01 00:00:00

pages

076009

issue

7

eissn

1083-3668

issn

1560-2281

journal_volume

16

pub_type

杂志文章
  • Comparative evaluation of differential laser-induced perturbation spectroscopy as a technique to discriminate emerging skin pathology.

    abstract::Fluorescence spectroscopy has been widely investigated as a technique for identifying pathological tissue; however, unrelated subject-to-subject variations in spectra complicate data analysis and interpretation. We describe and evaluate a new biosensing technique, differential laser-induced perturbation spectroscopy (...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.6.067002

    authors: Kozikowski RT,Smith SE,Lee JA,Castleman WL,Sorg BS,Hahn DW

    更新日期:2012-06-01 00:00:00

  • Photodynamic therapy-induced nitric oxide production in neuronal and glial cells.

    abstract::Nitric oxide (NO) has been recently demonstrated to enhance apoptosis of glial cells induced by photodynamic therapy (PDT), but to protect glial cells from PDT-induced necrosis in the crayfish stretch receptor, a simple neuroglial preparation that consists of a single mechanosensory neuron enveloped by satellite glial...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.10.105005

    authors: Kovaleva VD,Uzdensky AB

    更新日期:2016-10-01 00:00:00

  • "Seeing" electroencephalogram through the skull: imaging prefrontal cortex with fast optical signal.

    abstract::Near-infrared spectroscopy is a novel imaging technique potentially sensitive to both brain hemodynamics (slow signal) and neuronal activity (fast optical signal, FOS). The big challenge of measuring FOS noninvasively lies in the presumably low signal-to-noise ratio. Thus, detectability of the FOS has been controversi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3505007

    authors: Medvedev AV,Kainerstorfer JM,Borisov SV,Gandjbakhche AH,Vanmeter J

    更新日期:2010-11-01 00:00:00

  • Quantitative real-time optical imaging of the tissue metabolic rate of oxygen consumption.

    abstract::The tissue metabolic rate of oxygen consumption (tMRO2) is a clinically relevant marker for a number of pathologies including cancer and arterial occlusive disease. We present and validate a noncontact method for quantitatively mapping tMRO2 over a wide, scalable field of view at 16  frames  /  s. We achieve this by d...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.3.036013

    authors: Ghijsen M,Lentsch GR,Gioux S,Brenner M,Durkin AJ,Choi B,Tromberg BJ

    更新日期:2018-03-01 00:00:00

  • Specific absorption spectra of hemoglobin at different PO2 levels: potential noninvasive method to detect PO2 in tissues.

    abstract::Hemoglobin (Hb), as one of main components of blood, has a unique quaternary structure. Its release of oxygen is controlled by oxygen partial pressure (PO2). We investigate the specific spectroscopic changes in Hb under different PO2 levels to optimize clinical methods of measuring tissue PO2. The transmissivity of Hb...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.12.125002

    authors: Liu P,Zhu Z,Zeng C,Nie G

    更新日期:2012-12-01 00:00:00

  • Spectral classifier design with ensemble classifiers and misclassification-rejection: application to elastic-scattering spectroscopy for detection of colonic neoplasia.

    abstract::Optical spectroscopy has shown potential as a real-time, in vivo, diagnostic tool for identifying neoplasia during endoscopy. We present the development of a diagnostic algorithm to classify elastic-scattering spectroscopy (ESS) spectra as either neoplastic or non-neoplastic. The algorithm is based on pattern recognit...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3592488

    authors: Rodriguez-Diaz E,Castanon DA,Singh SK,Bigio IJ

    更新日期:2011-06-01 00:00:00

  • Dynamic in vivo imaging of small animal brain using pulsed laser diode-based photoacoustic tomography system.

    abstract::We demonstrate dynamic in vivo imaging using a low-cost portable pulsed laser diode (PLD)-based photoacoustic tomography system. The system takes advantage of an 803-nm PLD having high-repetition rate ∼7000  Hz combined with a fast-scanning single-element ultrasound transducer leading to a 5 s cross-sectional imaging....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.9.090501

    authors: Upputuri PK,Pramanik M

    更新日期:2017-09-01 00:00:00

  • Investigation of the cerebral hemodynamic response function in single blood vessels by functional photoacoustic microscopy.

    abstract::The specificity of the hemodynamic response function (HRF) is determined spatially by the vascular architecture and temporally by the evolution of hemodynamic changes. Here, we used functional photoacoustic microscopy (fPAM) to investigate single cerebral blood vessels of rats after left forepaw stimulation. In this s...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.6.061210

    authors: Liao LD,Lin CT,Shih YY,Lai HY,Zhao WT,Duong TQ,Chang JY,Chen YY,Li ML

    更新日期:2012-06-01 00:00:00

  • Optical coherence tomography in gynecology: a narrative review.

    abstract::Modern gynecologic practice requires noninvasive diagnostics techniques capable of detecting morphological and functional alterations in tissues of female reproductive organs. Optical coherence tomography (OCT) is a promising tool for providing imaging of biotissues with high resolution at depths up to 2 mm. Design of...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.22.12.121709

    authors: Kirillin M,Motovilova T,Shakhova N

    更新日期:2017-12-01 00:00:00

  • Refractive index correction in optical coherence tomography images of multilayer tissues.

    abstract::We propose an algorithm to compensate for the refractive index error in the optical coherence tomography (OCT) images of multilayer tissues, such as skin. The performance of the proposed method has been evaluated on one- and two-layer solid phantoms, as well as the skin of rat paw. ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.7.070501

    authors: Turani Z,Fatemizadeh E,Xu Q,Daveluy S,Mehregan D,Nasiri Avanaki MR

    更新日期:2018-07-01 00:00:00

  • Voxel-based measurement sensitivity of spatially resolved near-infrared spectroscopy in layered tissues.

    abstract::We quantitatively investigated the measurement sensitivity of spatially resolved spectroscopy (SRS) across six tissue models: cerebral tissue, a small animal brain, the forehead of a fetus, an adult brain, forearm muscle, and thigh muscle. The optical path length in the voxel of the model was analyzed using Monte Carl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.3.030503

    authors: Niwayama M

    更新日期:2018-03-01 00:00:00

  • Early diagnosis of teeth erosion using polarized laser speckle imaging.

    abstract::Dental erosion starts with a chemical attack on dental tissue causing tooth demineralization, altering the tooth structure and making it more sensitive to mechanical erosion. Medical diagnosis of dental erosion is commonly achieved through a visual inspection by the dentist during dental checkups and is therefore high...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.7.071103

    authors: Abou Nader C,Pellen F,Loutfi H,Mansour R,Le Jeune B,Le Brun G,Abboud M

    更新日期:2016-07-01 00:00:00

  • Impact of treatment response metrics on photodynamic therapy planning and outcomes in a three-dimensional model of ovarian cancer.

    abstract::Common methods to characterize treatment efficacy based on morphological imaging may misrepresent outcomes and exclude effective therapies. Using a three-dimensional model of ovarian cancer, two functional treatment response metrics are used to evaluate photodynamic therapy (PDT) efficacy: total volume, calculated fro...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.9.098004

    authors: Anbil S,Rizvi I,Celli JP,Alagic N,Pogue BW,Hasan T

    更新日期:2013-09-01 00:00:00

  • Chemical reactivation of fluorescein isothiocyanate immunofluorescence-labeled resin-embedded samples.

    abstract::Resin embedding is widely used and facilitates microscopic imaging of biological tissues. In contrast, quenching of fluorescence during embedding process hinders the application of resin embedding for imaging of fluorescence-labeled samples. For samples expressing fluorescent proteins, it has been demonstrated that th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.2.020501

    authors: Li L,Rao G,Lv X,Chen R,Cheng X,Wang X,Zeng S,Liu X

    更新日期:2018-02-01 00:00:00

  • Oblique incidence reflectometry: optical models and measurements using a side-viewing gradient index lens-based endoscopic imaging system.

    abstract::A side-viewing, 2.3-mm diameter oblique incidence reflectometry endoscope has been designed to obtain optical property measurements of turbid samples. Light from a single-mode fiber is relayed obliquely onto the tissue with a gradient index lens-based distal optics assembly and the resulting diffuse reflectance profil...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.6.067002

    authors: Wall RA,Barton JK

    更新日期:2014-06-01 00:00:00

  • Caries detection and quantification around stained pits and fissures in occlusal tooth surfaces with fluorescence.

    abstract::Occlusal discoloration due to staining frequently occurs on the pits and fissures of teeth. Noncariogenic discoloration (non-CD) refers to the attachment of staining chromogens to sound surfaces, whereas cariogenic discoloration (CD) represents the discoloration of porous structures due to bacterial metabolites and mi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.9.091402

    authors: Lee HS,Kim SK,Park SW,de Josselin de Jong E,Kwon HK,Jeong SH,Kim BI

    更新日期:2018-03-01 00:00:00

  • Design and characterization of a handheld multimodal imaging device for the assessment of oral epithelial lesions.

    abstract::A compact handpiece combining high resolution fluorescence (HRF) imaging with optical coherence tomography (OCT) was developed to provide real-time assessment of oral lesions. This multimodal imaging device simultaneously captures coregistered en face images with subcellular detail alongside cross-sectional images of ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.8.086004

    authors: Higgins LM,Pierce MC

    更新日期:2014-08-01 00:00:00

  • Offset-sparsity decomposition for automated enhancement of color microscopic image of stained specimen in histopathology.

    abstract::We propose an offset-sparsity decomposition method for the enhancement of a color microscopic image of a stained specimen. The method decomposes vectorized spectral images into offset terms and sparse terms. A sparse term represents an enhanced image, and an offset term represents a "shadow." The related optimization ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.7.076012

    authors: Kopriva I,Hadžija MP,Hadžija M,Aralica G

    更新日期:2015-07-01 00:00:00

  • Determination of optical properties of human blood in the spectral range 250 to 1100 nm using Monte Carlo simulations with hematocrit-dependent effective scattering phase functions.

    abstract::The absorption coefficient mu(a), scattering coefficient mu(s), and anisotropy factor g of diluted and undiluted human blood (hematocrit 0.84 and 42.1%) are determined under flow conditions in the wavelength range 250 to 1100 nm, covering the absorption bands of hemoglobin. These values are obtained by high precision ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2203659

    authors: Friebel M,Roggan A,Müller G,Meinke M

    更新日期:2006-05-01 00:00:00

  • Evaluation of BCECF fluorescence ratio imaging to properly measure gastric intramucosal pH variations in vivo.

    abstract::Our purpose is to evaluate intramucosal gastric pH video imaging by 2('),7(')-bis(carboxyethyl)-5,6-carboxyfluorescein (BCECF) fluorescence ratio techniques. We use a video endoscopic imaging system and BCECF as the pH fluorescent probe. Systemic in vivo pH variations are studied in 10 pigs: five in the control group ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2821698

    authors: Rochon P,Jourdain M,Mangalaboyi J,Fourrier F,Soulié-Bégu S,Buys B,Dehlin G,Lesage JC,Chambrin MC,Mordon S

    更新日期:2007-11-01 00:00:00

  • Spatially confined and temporally resolved refractive index and scattering evaluation in human skin performed with optical coherence tomography.

    abstract::In the present applications of optical coherence tomography (OCT), parameters besides pure morphology are evaluated in skin tissue under in vivo conditions. Spatially mapped refractive indices and scattering coefficients may support tissue characterization for research and diagnostic purposes in cosmetics/pharmacy and...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.429972

    authors: Knüttel A,Boehlau-Godau M

    更新日期:2000-01-01 00:00:00

  • Detecting glucose-induced changes in in vitro and in vivo experiments with optical coherence tomography.

    abstract::Optical clearing is a well-known phenomenon. It is based on the matching of refractive indices of a bulk material and scattering particles. The same principle is also used in scattering-based optical measurements of different constituents, such as glucose. By registering changes in scattering, it is possible to evalua...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2904957

    authors: Kinnunen M,Myllylä R,Vainio S

    更新日期:2008-03-01 00:00:00

  • Detection of intramyocardial scroll waves using absorptive transillumination imaging.

    abstract::Optical imaging using voltage-sensitive dyes has become an important tool for studying vortex-like electrical waves in the heart. Such waves, known as spiral or scroll waves, can spontaneously form in pathological ventricular myocardium, causing ventricular fibrillation and sudden death. Until recently, observations o...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2709661

    authors: Bernus O,Mukund KS,Pertsov AM

    更新日期:2007-01-01 00:00:00

  • Design and validation of an angle-resolved low-coherence interferometry fiber probe for in vivo clinical measurements of depth-resolved nuclear morphology.

    abstract::We present a novel Fourier-domain angle-resolved low-coherence interferometry (a /LCI) fiber probe designed for in vivo clinical application in gastrointestinal endoscopy. The a/LCI technique measures the depth-resolved angular scattering distribution to determine the size distribution and optical density of cell nucl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3520130

    authors: Zhu Y,Terry NG,Woosley JT,Shaheen NJ,Wax A

    更新日期:2011-01-01 00:00:00

  • In vivo wide-field multispectral scanning laser ophthalmoscopy-optical coherence tomography mouse retinal imager: longitudinal imaging of ganglion cells, microglia, and Müller glia, and mapping of the mouse retinal and choroidal vasculature.

    abstract::Scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT) provide complementary views of the retina, with the former collecting fluorescence data with good lateral but relatively low-axial resolution, and the latter collecting label-free backscattering data with comparable lateral but much higher axia...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.12.126005

    authors: Zhang P,Zam A,Jian Y,Wang X,Li Y,Lam KS,Burns ME,Sarunic MV,Pugh EN Jr,Zawadzki RJ

    更新日期:2015-01-01 00:00:00

  • Holographic analysis on deformation and restoration of malaria-infected red blood cells by antimalarial drug.

    abstract::Malaria parasites induce morphological, biochemical, and mechanical changes in red blood cells (RBCs). Mechanical variations are closely related to the deformability of individual RBCs. The deformation of various RBCs, including healthy and malaria-infected RBCs (iRBCs), can be directly observed through quantitative p...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.11.115003

    authors: Byeon H,Ha YR,Lee SJ

    更新日期:2015-11-01 00:00:00

  • Closure of skin incisions by laser-welding with a combination of two near-infrared diode lasers: preliminary study for determination of optimal parameters.

    abstract::Laser welding has the potential to become an effective method for wound closure and healing without sutures. Closure of skin incisions by laser welding with a combination of two near-infrared lasers (980 and 1064 nm), was performed for the first time in this study. One centimeter long, full-thickness incisions were ma...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3552648

    authors: Hu L,Lu Z,Wang B,Cao J,Ma X,Tian Z,Gao Z,Qin L,Wu X,Liu Y,Wang L

    更新日期:2011-03-01 00:00:00

  • High-magnification vascular imaging to reject false-positive sites in situ during Hexvix® fluorescence cystoscopy.

    abstract::Fluorescence imaging for detection of non-muscle-invasive bladder cancer is based on the selective production and accumulation of fluorescing porphyrins-mainly, protoporphyrin IX-in cancerous tissues after the instillation of Hexvix®. Although the sensitivity of this procedure is very good, its specificity is somewhat...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3484257

    authors: Lovisa B,Jichlinski P,Weber BC,Aymon D,van den Bergh H,Wagnières G

    更新日期:2010-09-01 00:00:00

  • Potential of optical microangiography to monitor cerebral blood perfusion and vascular plasticity following traumatic brain injury in mice in vivo.

    abstract::Optical microanglography (OMAG) is a recently developed imaging modality capable of volumetric imaging of dynamic blood perfusion, down to capillary level resolution, with an imaging depth up to 2.00 mm beneath the tissue surface. We report the use of OMAG to monitor the cerebral blood flow (CBF) over the cortex of mo...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3207121

    authors: Jia Y,Alkayed N,Wang RK

    更新日期:2009-07-01 00:00:00

  • Quantitative fluorescence tomography using a trimodality system: in vivo validation.

    abstract::A fully integrated trimodality fluorescence, diffuse optical, and x-ray computed tomography (FT/DOT/XCT) system for small animal imaging is reported in this work. The main purpose of this system is to obtain quantitatively accurate fluorescence concentration images using a multimodality approach. XCT offers anatomical...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3467495

    authors: Lin Y,Barber WC,Iwanczyk JS,Roeck WW,Nalcioglu O,Gulsen G

    更新日期:2010-07-01 00:00:00