Abstract:
:Fluorescence spectroscopy has been widely investigated as a technique for identifying pathological tissue; however, unrelated subject-to-subject variations in spectra complicate data analysis and interpretation. We describe and evaluate a new biosensing technique, differential laser-induced perturbation spectroscopy (DLIPS), based on deep ultraviolet (UV) photochemical perturbation in combination with difference spectroscopy. This technique combines sequential fluorescence probing (pre- and post-perturbation) with sub-ablative UV perturbation and difference spectroscopy to provide a new spectral dimension, facilitating two improvements over fluorescence spectroscopy. First, the differential technique eliminates significant variations in absolute fluorescence response within subject populations. Second, UV perturbations alter the extracellular matrix (ECM), directly coupling the DLIPS response to the biological structure. Improved biosensing with DLIPS is demonstrated in vivo in a murine model of chemically induced skin lesion development. Component loading analysis of the data indicates that the DLIPS technique couples to structural proteins in the ECM. Analysis of variance shows that DLIPS has a significant response to emerging pathology as opposed to other population differences. An optimal likelihood ratio classifier for the DLIPS dataset shows that this technique holds promise for improved diagnosis of epithelial pathology. Results further indicate that DLIPS may improve diagnosis of tissue by augmenting fluorescence spectra (i.e. orthogonal sensing).
journal_name
J Biomed Optjournal_title
Journal of biomedical opticsauthors
Kozikowski RT,Smith SE,Lee JA,Castleman WL,Sorg BS,Hahn DWdoi
10.1117/1.JBO.17.6.067002subject
Has Abstractpub_date
2012-06-01 00:00:00pages
067002issue
6eissn
1083-3668issn
1560-2281journal_volume
17pub_type
杂志文章abstract::Doxorubicin is a commonly used chemotherapeutic employed to treat multiple human cancers, including numerous sarcomas and carcinomas. Furthermore, doxorubicin possesses strong fluorescent properties that make it an ideal reagent for modeling drug delivery by examining its distribution in cells and tissues. However, wh...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.22.11.116010
更新日期:2017-11-01 00:00:00
abstract::Current diagnostic capabilities and limitations of fluorescence endomicroscopy in the cervix are assessed by qualitative and quantitative image analysis. Four cervical tissue types are investigated: normal columnar epithelium, normal and precancerous squamous epithelium, and stromal tissue. This study focuses on the p...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.12.126011
更新日期:2016-12-01 00:00:00
abstract::Invasive brain cancer cells cannot be visualized during surgery and so they are often not removed. These residual cancer cells give rise to recurrences. journal_title:Journal of biomedical optics pub_type: 杂志文章 doi:10.1117/1.JBO.21.9.094002 更新日期:2016-09-01 00:00:00
abstract::We demonstrate the ex vivo imaging of an oral cancerous sample with a swept-source optical coherence tomography (SS-OCT) system. With the axial resolution of 8 microm in free space and system sensitivity of 108 dB, we can well distinguish the normal and abnormal tissue portions in a sample. In particular, we analyze t...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2960632
更新日期:2008-07-01 00:00:00
abstract::We propose a useful method to boost the imaging speed for spectral domain optical coherence tomography (SDOCT) by multiplying a number of high-speed spectrometers used in the system with selective precise control of data-recording and data-reading phases for spectral cameras employed in each spectrometer. To demonstra...
journal_title:Journal of biomedical optics
pub_type: 信件
doi:10.1117/1.3592492
更新日期:2011-06-01 00:00:00
abstract::In order to monitor dynamic physiological events in near-real time, a variety of photoacoustic computed tomography (PACT) systems have been developed that can rapidly acquire data. Previously reported studies of dynamic PACT have employed conventional static methods to reconstruct a temporally ordered sequence of imag...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.19.5.056007
更新日期:2014-05-01 00:00:00
abstract::Angle-resolved signals of polarized light scattered by biological cells provide rich information on cell morphology. Quantitative study of these signals can lead to new methods to develop and improve high-throughput instrumentation for cell probing such as scattering-based flow cytometry. We employ a goniometer system...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2749730
更新日期:2007-05-01 00:00:00
abstract::We present a novel confocal microscope that has dual-axis architecture and biaxial postobjective scanning for the collection of fluorescence images from biological specimens. This design uses two low-numerical-aperture lenses to achieve high axial resolution and long working distance, and the scanning mirror located d...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1760760
更新日期:2004-07-01 00:00:00
abstract::We demonstrate dynamic in vivo imaging using a low-cost portable pulsed laser diode (PLD)-based photoacoustic tomography system. The system takes advantage of an 803-nm PLD having high-repetition rate ∼7000 Hz combined with a fast-scanning single-element ultrasound transducer leading to a 5 s cross-sectional imaging....
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.22.9.090501
更新日期:2017-09-01 00:00:00
abstract::The specificity of molecular and functional photoacoustic (PA) images depends on the accuracy of the photoacoustic absorption spectroscopy. The PA signal is proportional to the product of the optical absorption coefficient and local light fluence; quantitative PA measurements of the optical absorption coefficient ther...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3626212
更新日期:2011-09-01 00:00:00
abstract::We measure the tumor vascular response to varying irradiance rates during photodynamic therapy (PDT) in a Dunning rat prostate model with interstitial Doppler optical coherence tomography (IS-DOCT). Rats are given a photosensitizer drug, Photofrin, and the tumors are exposed to light (635 nm) with irradiance rates ran...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2744068
更新日期:2007-05-01 00:00:00
abstract::A need exists for the continued development of diagnostic tools and methods capable of distinguishing and characterizing slight differences in the optical properties of tissues. We present a method to estimate the scattering coefficient contribution as a function of particle size in complex mixtures of polystyrene sph...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2363347
更新日期:2006-09-01 00:00:00
abstract::Frequency domain optical coherence tomography (FD-OCT), based on an all-reflective high-speed InGaAs spectrometer, operating in the 1050 nm wavelength region for retinal diagnostics, enables high-speed, volumetric imaging of retinal pathologies with greater penetration into choroidal tissue is compared to conventional...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2773728
更新日期:2007-07-01 00:00:00
abstract::We report a new two-channel fluorescence microscopy technique for surface-generated fluorescence. The realized fluorescence microscope allows high resolution imaging of aqueous samples. The core element of the instrument is a parabolic mirror objective that is used to collect the fluorescence at large surface angles a...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2747627
更新日期:2007-05-01 00:00:00
abstract::We investigate the feasibility of using diode laser gas spectroscopy for sinusitis diagnostics. We simulate light propagation using the Monte Carlo concept, as implemented by the Advanced Systems Analysis Program (ASAP) software. Simulations and experimental data are compared for a model based on two scattering bodies...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2777179
更新日期:2007-09-01 00:00:00
abstract::We present three-dimensional (3-D) high-resolution spectral-domain optical coherence microscopy (SD-OCM) by using a supercontinuum (SC) fiber laser source with 300-nm spectral bandwidth (full-width at half-maximum) in the 1700-nm spectral band. By using low-coherence interferometry with SC light and a confocal detecti...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.24.7.070502
更新日期:2019-07-01 00:00:00
abstract::We demonstrate the in vivo assessment of human scars by parametric imaging of birefringence using polarization-sensitive optical coherence tomography (PS-OCT). Such in vivo assessment is subject to artifacts in the detected birefringence caused by scattering from blood vessels. To reduce these artifacts, we preprocess...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.19.12.126014
更新日期:2014-12-01 00:00:00
abstract::With the advance of computer and photonics technology, imaging photoplethysmography [(PPG), iPPG] can provide comfortable and comprehensive assessment over a wide range of anatomical locations. However, motion artifact is a major drawback in current iPPG systems, particularly in the context of clinical assessment. To ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3602852
更新日期:2011-07-01 00:00:00
abstract::Fluorescence cystoscopy (FC) efficiently enhances the detection and improves the therapeutic management of early bladder cancer. During an FC, about 150 ml of water is needed to inflate the bladder. The water is quickly diluted by urine which can be fluorescent. If this bladder washout fluid (BWF) becomes fluorescent,...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.6.066011
更新日期:2015-06-01 00:00:00
abstract::We report on wide-field imaging of pulsatile motion induced by blood flow using heterodyne holographic interferometry on the thumb of a healthy volunteer, in real time. Optical Doppler images were measured with green laser light by a frequency-shifted Mach-Zehnder interferometer in off-axis configuration. The recorded...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.6.066006
更新日期:2015-06-01 00:00:00
abstract::We present a multimodal optical microscope that incorporates six imaging modalities on one common platform. The imaging modalities include three staring modes, optical quadrature microscopy (OQM), differential interference contrast (DIC) microscopy, and epi-fluorescence microscopy, and three scanning modes, confocal r...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2753744
更新日期:2007-07-01 00:00:00
abstract::We have developed a near-infrared (NIR) fluorescence goggle system based on the complementary metal-oxide-semiconductor active pixel sensor imaging and see-through display technologies. The fluorescence goggle system is a compact wearable intraoperative fluorescence imaging and display system that can guide surgery in...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.10.101303
更新日期:2013-10-01 00:00:00
abstract::An adaptive pulse shaper controlled by multiphoton intrapulse interference phase scanning (MIIPS) was used, together with a prism-pair, to measure and cancel high-order phase distortions introduced by a high-numerical-aperture objective and other dispersive elements of a two-photon laser-scanning microscope. The deliv...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3059629
更新日期:2009-01-01 00:00:00
abstract::Three major analytical tools in imaging science are summarized and demonstrated relative to optical imaging in vivo. Standard resolution testing is optimal when infinite contrast is used and hardware evaluation is the goal. However, deep tissue imaging of absorption or fluorescent contrast agents in vivo often present...
journal_title:Journal of biomedical optics
pub_type: 杂志文章,评审
doi:10.1117/1.2209908
更新日期:2006-05-01 00:00:00
abstract::Optical measurements of metabolism are ideally acquired in vivo; however, intravital measurements are often impractical. Accurate ex vivo assessments would greatly broaden the applicability of optical measurements of metabolism. We investigate the use of live tissue culture experiments to serve as a surrogate for in v...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.17.11.116015
更新日期:2012-11-01 00:00:00
abstract::The absorption of filter substances in sunscreens, reducing the incident ultraviolet (UV) radiation, is the basis for the protecting ability of such formulations. The erythema-correlated sun protection factor (SPF), depending mainly on the intensity of the UVB radiation, is the common value to quantify the efficacy of...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3497047
更新日期:2010-09-01 00:00:00
abstract::The optical activity of glucose molecules is important for diagnosing and monitoring blood glucose of diabetes. In order to accurately detect the diabetes at an early stage, there is an urgent need to develop innovative detection methods. By use of Mueller matrix decomposition (MMD), we have studied the optical activi...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.19.4.046015
更新日期:2014-04-01 00:00:00
abstract::Environmental metastability of zirconia (ZrO2) ceramic in the human body [represented by a tetragonal-to-monoclinic (t→m) phase transformation] takes place on the surface of the artificial joint and proceeds with time toward its interior. Its quantitative characterization is mandatory for the safety of joint implants ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.12.127002
更新日期:2013-12-01 00:00:00
abstract::Diffuse reflectance spectroscopy, which has been demonstrated as a noninvasive diagnostic technique, relies on quantitative models for extracting optical property values from turbid media, such as biological tissues. We review and compare reflectance models that have been published, and we test similar models over a m...
journal_title:Journal of biomedical optics
pub_type: 杂志文章,评审
doi:10.1117/1.JBO.19.7.075005
更新日期:2014-01-01 00:00:00
abstract::The objective is to characterize the impact of different ablation parameters on the thermal load during corneal refractive surgery by means of excimer laser ablation on porcine eyes. One hundred eleven ablations were performed in 105 porcine eyes. Each ablation was recorded using infrared thermography and analyzed mai...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.7.078001
更新日期:2015-07-01 00:00:00