Quantitative photoacoustic imaging: correcting for heterogeneous light fluence distributions using diffuse optical tomography.

Abstract:

:The specificity of molecular and functional photoacoustic (PA) images depends on the accuracy of the photoacoustic absorption spectroscopy. The PA signal is proportional to the product of the optical absorption coefficient and local light fluence; quantitative PA measurements of the optical absorption coefficient therefore require an accurate estimation of optical fluence. Light-modeling aided by diffuse optical tomography (DOT) can be used to map the required fluence and to reduce errors in traditional PA spectroscopic analysis. As a proof-of-concept, we designed a tissue-mimicking phantom to demonstrate how fluence-related artifacts in PA images can lead to misrepresentations of tissue properties. To correct for these inaccuracies, the internal fluence in the tissue phantom was estimated by using DOT to reconstruct spatial distributions of the absorption and reduced scattering coefficients of multiple targets within the phantom. The derived fluence map, which only consisted of low spatial frequency components, was used to correct PA images of the phantom. Once calibrated to a known absorber, this method reduced errors in estimated absorption coefficients from 33% to 6%. These results experimentally demonstrate that combining DOT with PA imaging can significantly reduce fluence-related errors in PA images, while producing quantitatively accurate, high-resolution images of the optical absorption coefficient.

journal_name

J Biomed Opt

authors

Bauer AQ,Nothdurft RE,Erpelding TN,Wang LV,Culver JP

doi

10.1117/1.3626212

subject

Has Abstract

pub_date

2011-09-01 00:00:00

pages

096016

issue

9

eissn

1083-3668

issn

1560-2281

journal_volume

16

pub_type

杂志文章
  • Raman mapping of oral buccal mucosa: a spectral histopathology approach.

    abstract::Oral cancer is one of the most common cancers worldwide. One-fifth of the world's oral cancer subjects are from India and other South Asian countries. The present Raman mapping study was carried out to understand biochemical variations in normal and malignant oral buccal mucosa. Data were acquired using WITec alpha 30...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.12.126005

    authors: Behl I,Kukreja L,Deshmukh A,Singh SP,Mamgain H,Hole AR,Krishna CM

    更新日期:2014-12-01 00:00:00

  • Imaging and tracking HIV viruses in human cervical mucus.

    abstract::We describe a systematic approach to image, track, and quantify the movements of HIV viruses embedded in human cervical mucus. The underlying motivation for this study is that, in HIV-infected adults, women account for more than half of all new cases and most of these women acquire the infection through heterosexual c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.9.096001

    authors: Boukari F,Makrogiannis S,Nossal R,Boukari H

    更新日期:2016-09-01 00:00:00

  • Correlation of functional and resting state connectivity of cerebral oxy-, deoxy-, and total hemoglobin concentration changes measured by near-infrared spectrophotometry.

    abstract::The aim is to study cerebral vascular functional connectivity during motor tasks and resting state using multichannel frequency-domain near-infrared spectrophotometry. Maps of 5.7 × 10.8 cm size displaying changes in cerebral oxyhemoglobin (O(2)Hb), deoxyhemoglobin (HHb), and total hemoglobin (tHb) concentrations were...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3615249

    authors: Wolf U,Toronov V,Choi JH,Gupta R,Michalos A,Gratton E,Wolf M

    更新日期:2011-08-01 00:00:00

  • Infrared spectroscopic imaging of renal tumor tissue.

    abstract::Fourier transform infrared (FTIR) spectroscopic imaging has been used to probe the biochemical composition of human renal tumor tissue and adjacent normal tissue. Freshly resected renal tumor tissue from surgery was prepared as a thin cryosection and examined by FTIR spectroscopic imaging. Tissue types could be discri...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3622292

    authors: Sablinskas V,Urboniene V,Ceponkus J,Laurinavicius A,Dasevicius D,Jankevicius F,Hendrixson V,Koch E,Steiner G

    更新日期:2011-09-01 00:00:00

  • Fundamental Studies of Fiber-Guided Soft Tissue Cutting by Means of Pulsed Midinfrared Lasers and their Application in Ureterotomy.

    abstract::Fiber-guided ablation of soft tissue with pulsed holmium and thulium lasers was investigated for intraluminal incisions. A bare fiber/tissue-contact application system with a nearly tangential irradiation geometry was first used in vitro on porcine ureter tissue. The efficiency and precision of the method was analyzed...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429865

    authors: Brinkmann R,Knipper A,Dro Ge G,Schro Er F,Gromoll B,Birngruber R

    更新日期:1998-01-01 00:00:00

  • Imaging tumor hypoxia by near-infrared fluorescence tomography.

    abstract::We have developed a novel nitroimidazole indocyanine dye conjugate for tumor-targeted hypoxia fluorescence tomography. The hypoxia probe has been evaluated in vitro using tumor cell lines and in vivo with tumor targeting in mice. The in vitro cell studies were performed to assess fluorescence labeling differences betw...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3589348

    authors: Biswal NC,Pavlik C,Smith MB,Aguirre A,Xu Y,Zanganeh S,Kuhn LT,Claffey KP,Zhu Q

    更新日期:2011-06-01 00:00:00

  • Optical oximetry of volume-oscillating vascular compartments: contributions from oscillatory blood flow.

    abstract::We present a quantitative analysis of dynamic diffuse optical measurements to obtain oxygen saturation of hemoglobin in volume oscillating compartments. We used a phasor representation of oscillatory hemodynamics at the heart rate and respiration frequency to separate the oscillations of tissue concentrations of oxyhe...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.10.101408

    authors: Kainerstorfer JM,Sassaroli A,Fantini S

    更新日期:2016-10-01 00:00:00

  • Extending Förster resonance energy transfer measurements beyond 100 Å using common organic fluorophores: enhanced transfer in the presence of multiple acceptors.

    abstract::Using commercially available organic fluorophores, the current applications of Förster (fluorescence) resonance energy transfer (FRET) are limited to about 80 Å. However, many essential activities in cells are spatially and/or temporally dependent on the assembly/disassembly of transient complexes consisting of large-...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.1.011006

    authors: Maliwal BP,Raut S,Fudala R,D'Auria S,Marzullo VM,Luini A,Gryczynski I,Gryczynski Z

    更新日期:2012-01-01 00:00:00

  • Waveguide evanescent field fluorescence microscopy: high contrast imaging of a domain forming mixed lipid Langmuir-Blodgett monolayer mimicking lung surfactant.

    abstract::Waveguide evanescent field fluorescence (WEFF) microscopy is a new development that allows the imaging of contact regions between biological cells and their substratum, as well as imaging of ultrathin films such as monomolecular Langmuir-Blodgett (LB) films. Mixed-lipid monolayer systems mimicking lung surfactant were...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3569095

    authors: Hassanzadeh A,Mittler S

    更新日期:2011-04-01 00:00:00

  • Light scattering of human red blood cells during metabolic remodeling of the membrane.

    abstract::We present the light scattering properties of individual human red blood cells (RBCs). We show that both the RBC static and dynamic scattering signals are altered by adenosine 5'-triphosphate (ATP)-driven membrane metabolic remodeling. To measure the light scattering signal from individual RBCs, we use diffraction pha...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3524509

    authors: Park Y,Best-Popescu CA,Dasari RR,Popescu G

    更新日期:2011-01-01 00:00:00

  • Pediatric Vision Screener 2: pilot study in adults.

    abstract::Amblyopia is a form of visual impairment caused by ocular misalignment (strabismus) or defocus in an otherwise healthy eye. If detected early, the condition can be fully treated, yet over half of all children with amblyopia under age 5 escape detection. We developed a Pediatric Vision Screener (PVS) to detect amblyopi...

    journal_title:Journal of biomedical optics

    pub_type: 临床试验,杂志文章

    doi:10.1117/1.1805561

    authors: Nassif DS,Piskun NV,Gramatikov BI,Guyton DL,Hunter DG

    更新日期:2004-11-01 00:00:00

  • Myocardial tissue oxygenation estimated with calibrated diffuse reflectance spectroscopy during coronary artery bypass grafting.

    abstract::We present a study using a method able to assess tissue oxygenation, taking into account the absorption and the level of scattering in myocardial tissue using a calibrated fiber optic probe. With this method, interindividual comparisons of oxygenation can be made despite varying tissue optical properties during corona...

    journal_title:Journal of biomedical optics

    pub_type: 临床试验,杂志文章

    doi:10.1117/1.2976433

    authors: Häggblad E,Lindbergh T,Karlsson MG,Casimir-Ahn H,Salerud EG,Strömberg T

    更新日期:2008-09-01 00:00:00

  • Three-dimensional surface reconstruction within noncontact diffuse optical tomography using structured light.

    abstract::A main field in biomedical optics research is diffuse optical tomography, where intensity variations of the transmitted light traversing through tissue are detected. Mathematical models and reconstruction algorithms based on finite element methods and Monte Carlo simulations describe the light transport inside the tis...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.12.126009

    authors: Baum K,Hartmann R,Bischoff T,Oelerich JO,Finkensieper S,Heverhagen JT

    更新日期:2012-12-01 00:00:00

  • Nonlinear multispectral imaging for tumor delineation.

    abstract:SIGNIFICANCE:In breast-preserving tumor surgery, the inspection of the excised tissue boundaries for tumor residue is too slow to provide feedback during the surgery. The discovery of positive margins requires a new surgery which is difficult and associated with low success. If the re-excision could be done immediately...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.9.096001

    authors: Beletkaia E,Dashtbozorg B,Jansen RG,Ruers TJM,Offerhaus HL

    更新日期:2020-09-01 00:00:00

  • New aspects in assessment of changes in width of subarachnoid space with near-infrared transillumination-backscattering sounding, part 2: clinical verification in the patient.

    abstract::The study presents comparison of near-infrared light propagation and near-infrared backscattered radiation power, as simulated with numerical modeling and measured live in a patient in clinical conditions with the use of the near-infrared transillumination-backscattering sounding (NIR-TBSS) technique. A unique chance ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2753756

    authors: Frydrychowski AF,Pluciński J

    更新日期:2007-07-01 00:00:00

  • Review of clinical approaches in fluorescence lifetime imaging ophthalmoscopy.

    abstract::Autofluorescence-based imaging techniques have become very important in the ophthalmological field. Being noninvasive and very sensitive, they are broadly used in clinical routines. Conventional autofluorescence intensity imaging is largely influenced by the strong fluorescence of lipofuscin, a fluorophore that can be...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.23.9.091415

    authors: Sauer L,Andersen KM,Dysli C,Zinkernagel MS,Bernstein PS,Hammer M

    更新日期:2018-09-01 00:00:00

  • SpineLab: tool for three-dimensional reconstruction of neuronal cell morphology.

    abstract::SpineLab is a software tool developed for reconstructing neuronal feature skeletons from three-dimensional single- or multi-photon image stacks. These images often suffer from limited resolution and a low signal-to-noise ratio, making the extraction of morphometric information difficult. To overcome this limitation, w...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.076007

    authors: Jungblut D,Vlachos A,Schuldt G,Zahn N,Deller T,Wittum G

    更新日期:2012-07-01 00:00:00

  • In vivo simultaneous multispectral fluorescence imaging with spectral multiplexed volume holographic imaging system.

    abstract::A simultaneous multispectral fluorescence imaging system incorporating multiplexed volume holographic grating (VHG) is developed to acquire multispectral images of an object in one shot. With the multiplexed VHG, the imaging system can provide the distribution and spectral characteristics of multiple fluorophores in t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.6.060502

    authors: Lv Y,Zhang J,Zhang D,Cai W,Chen N,Luo J

    更新日期:2016-06-01 00:00:00

  • Noninvasive enhanced mid-IR imaging of breast cancer development in vivo.

    abstract::Lumpectomy coupled with radiation therapy and/or chemotherapy is commonly used to treat breast cancer patients. We are developing an enhanced thermal IR imaging technique that has the potential to provide real-time imaging to guide tissue excision during a lumpectomy by delineating tumor margins. This enhanced thermal...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.11.116003

    authors: Case JR,Young MA,Dréau D,Trammell SR

    更新日期:2015-11-01 00:00:00

  • Fluorescence-based surface magnifying chromoendoscopy and optical coherence tomography endoscope.

    abstract::A side-viewing, 2.3-mm diameter, surface magnifying chromoendoscopy-optical coherence tomography (SMC-OCT) endoscope has been designed for simultaneous, nondestructive surface fluorescence visualization and cross-sectional imaging. We apply this endoscope to in vivo examination of the mouse colon. A 30,000 element fib...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.086003

    authors: Wall RA,Barton JK

    更新日期:2012-08-01 00:00:00

  • Comparison of motion correction techniques applied to functional near-infrared spectroscopy data from children (Erratum).

    abstract::The erratum concerns amendment of Section 2.5 of the published article. ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,已发布勘误

    doi:10.1117/1.JBO.25.5.059801

    authors: Hu XS,Arredondo MM,Gomba M,Confer N,DaSilva AF,Johnson TD,Shalinsky M,Kovelman I

    更新日期:2020-05-01 00:00:00

  • Innovative Troxler-free measurement of macular pigment and lens density with correction of the former for the aging lens.

    abstract::Simplified measurement of macular pigment optical density (MPOD) is important because of the ocular health benefits that are attributed to these retinal carotenoids. Here, we describe a novel instrument designed for this purpose, based on heterochromatic flicker photometry (HFP), which removes a number of difficulties...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.10.107003

    authors: Bone RA,Mukherjee A

    更新日期:2013-10-01 00:00:00

  • Diffuse reflectance spectroscopy as a tool for real-time tissue assessment during colorectal cancer surgery.

    abstract::Colorectal surgery is the standard treatment for patients with colorectal cancer. To overcome two of the main challenges, the circumferential resection margin and postoperative complications, real-time tissue assessment could be of great benefit during surgery. In this ex vivo study, diffuse reflectance spectroscopy (...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.10.106014

    authors: Baltussen EJM,Snaebjornsson P,de Koning SGB,Sterenborg HJCM,Aalbers AGJ,Kok N,Beets GL,Hendriks BHW,Kuhlmann KFD,Ruers TJM

    更新日期:2017-10-01 00:00:00

  • Modeling optical behavior of birefringent biological tissues for evaluation of quantitative polarized light microscopy.

    abstract::Quantitative polarized light microscopy (qPLM) is a popular tool for the investigation of birefringent architectures in biological tissues. Collagen, the most abundant protein in mammals, is such a birefringent material. Interpretation of results of qPLM in terms of collagen network architecture and anisotropy is chal...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3241986

    authors: van Turnhout MC,Kranenbarg S,van Leeuwen JL

    更新日期:2009-09-01 00:00:00

  • Human graft cornea and laser incisions imaging with micrometer scale resolution full-field optical coherence tomography.

    abstract::Micrometer scale resolution full-field optical coherence tomography (FF-OCT) is developed for imaging human graft corneas. Three-dimensional (3-D) images with ultrahigh resolution (respectively, 1 and 1.5 μm in the axial and transverse directions), comparable to traditional histological sections, are obtained allowing...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3486544

    authors: Latour G,Georges G,Lamoine LS,Deumié C,Conrath J,Hoffart L

    更新日期:2010-09-01 00:00:00

  • Depth-correction algorithm that improves optical quantification of large breast lesions imaged by diffuse optical tomography.

    abstract::Optical quantification of large lesions imaged with diffuse optical tomography in reflection geometry is depth dependence due to the exponential decay of photon density waves. We introduce a depth-correction method that incorporates the target depth information provided by coregistered ultrasound. It is based on balan...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3573814

    authors: Tavakoli B,Zhu Q

    更新日期:2011-05-01 00:00:00

  • In vitro model for endogenous optical signatures of collagen.

    abstract::Type I collagen is a major component of the extracellular matrix as well as many tissue engineered models. To understand changes in collagen related models over time, it is important to evaluate collagen dynamics with noninvasive techniques. Fluorescence spectroscopy provides a method to noninvasively measure endogeno...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2360516

    authors: Kirkpatrick ND,Hoying JB,Botting SK,Weiss JA,Utzinger U

    更新日期:2006-09-01 00:00:00

  • Two-photon microscopy of cortical NADH fluorescence intensity changes: correcting contamination from the hemodynamic response.

    abstract::Quantification of nicotinamide adenine dinucleotide (NADH) changes during functional brain activation and pathological conditions provides critical insight into brain metabolism. Of the different imaging modalities, two-photon laser scanning microscopy (TPLSM) is becoming an important tool for cellular-resolution meas...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3633339

    authors: Baraghis E,Devor A,Fang Q,Srinivasan VJ,Wu W,Lesage F,Ayata C,Kasischke KA,Boas DA,Sakadzić S

    更新日期:2011-10-01 00:00:00

  • Tool for simulating the focusing of arbitrary vector beams in free-space and stratified media.

    abstract::Vectorial models of focused beams are important to a variety of fields including microscopy, lithography, optical physics, and biomedical imaging. This has led to many models being developed, which calculate how beams of various profiles are focused both in free space and in the presence of stratified media. The major...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.9.090801

    authors: Munro PRT

    更新日期:2018-09-01 00:00:00

  • Accurate single-shot quantitative phase imaging of biological specimens with telecentric digital holographic microscopy.

    abstract::The advantages of using a telecentric imaging system in digital holographic microscopy (DHM) to study biological specimens are highlighted. To this end, the performances of nontelecentric DHM and telecentric DHM are evaluated from the quantitative phase imaging (QPI) point of view. The evaluated stability of the micro...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.4.046022

    authors: Doblas A,Sánchez-Ortiga E,Martínez-Corral M,Saavedra G,Garcia-Sucerquia J

    更新日期:2014-04-01 00:00:00