In vivo simultaneous multispectral fluorescence imaging with spectral multiplexed volume holographic imaging system.

Abstract:

:A simultaneous multispectral fluorescence imaging system incorporating multiplexed volume holographic grating (VHG) is developed to acquire multispectral images of an object in one shot. With the multiplexed VHG, the imaging system can provide the distribution and spectral characteristics of multiple fluorophores in the scene. The implementation and performance of the simultaneous multispectral imaging system are presented. Further, the system’s capability in simultaneously obtaining multispectral fluorescence measurements is demonstrated with in vivo experiments on a mouse. The demonstrated imaging system has the potential to obtain multispectral images fluorescence simultaneously.

journal_name

J Biomed Opt

authors

Lv Y,Zhang J,Zhang D,Cai W,Chen N,Luo J

doi

10.1117/1.JBO.21.6.060502

subject

Has Abstract

pub_date

2016-06-01 00:00:00

pages

60502

issue

6

eissn

1083-3668

issn

1560-2281

pii

2527605

journal_volume

21

pub_type

杂志文章
  • Monitoring of tumor response to cisplatin by subsurface fluorescence molecular tomography.

    abstract::Subsurface fluorescence molecular tomography (FMT) has promising potential for noninvasive characterization of molecular and cellular activities in small animals by tomographic means in reflectance geometry. In this work, subsurface FMT is employed to monitor the therapeutic response of cisplatin in tumor-bearing mice...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.17.4.040504

    authors: Liu F,Cao X,He W,Song J,Dai Z,Zhang B,Luo J,Li Y,Bai J

    更新日期:2012-04-01 00:00:00

  • Laser trap ionization for identification of human erythrocytes with variable hemoglobin quantitation.

    abstract::An approach to an established technique that is potentially applicable for a more comprehensive understanding of the electrical properties of red blood cells (RBCs) is presented. Using a high-intensity gradient laser trap, RBCs can be singly trapped and consequentially ionized. The subsequent dynamics of the ionized c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.5.055005

    authors: Kelley M,Cooper J,Devito D,Mushi R,Aguinaga MDP,Erenso DB

    更新日期:2018-05-01 00:00:00

  • Lesion strength control by automatic temperature guided retinal photocoagulation.

    abstract::Laser photocoagulation is an established treatment for a variety of retinal diseases. However, when using the same irradiation parameter, the size and strength of the lesions are unpredictable due to unknown inter- and intraindividual optical properties of the fundus layers. The aim of this work is to investigate a fe...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.9.098001

    authors: Schlott K,Koinzer S,Baade A,Birngruber R,Roider J,Brinkmann R

    更新日期:2016-09-01 00:00:00

  • Evaluation of hypericin-mediated photodynamic therapy in combination with angiogenesis inhibitor bevacizumab using in vivo fluorescence confocal endomicroscopy.

    abstract::Photodynamic therapy (PDT) is an alternative cancer treatment modality that offers localized treatment using a photosensitizer and light. However, tumor angiogenesis is a major concern following PDT-induced hypoxia as it promotes recurrence. Bevacizumab is a monoclonal antibody that targets vascular endothelial growth...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3281671

    authors: Bhuvaneswari R,Thong PS,Gan YY,Soo KC,Olivo M

    更新日期:2010-01-01 00:00:00

  • Angle-resolved Mueller matrix study of light scattering by B-cells at three wavelengths of 442, 633, and 850 nm.

    abstract::Angle-resolved signals of polarized light scattered by biological cells provide rich information on cell morphology. Quantitative study of these signals can lead to new methods to develop and improve high-throughput instrumentation for cell probing such as scattering-based flow cytometry. We employ a goniometer system...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2749730

    authors: Ding H,Lu JQ,Brock RS,McConnell TJ,Ojeda JF,Jacobs KM,Hu XH

    更新日期:2007-05-01 00:00:00

  • Statistical strategies to reveal potential vibrational markers for in vivo analysis by confocal Raman spectroscopy.

    abstract::The analysis of biological systems by spectroscopic techniques involves the evaluation of hundreds to thousands of variables. Hence, different statistical approaches are used to elucidate regions that discriminate classes of samples and to propose new vibrational markers for explaining various phenomena like disease m...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.7.075010

    authors: Oliveira Mendes Td,Pinto LP,Santos LD,Tippavajhala VK,Téllez Soto CA,Martin AA

    更新日期:2016-07-01 00:00:00

  • Minimizing Thermal Damage in Corneal Ablation with Short Pulse Mid-infrared Lasers.

    abstract::Photospallation is proposed as the primary mechanism behind our recent animal studies involving corneal ablation by nanosecond-pulse mid-IR laser beams. Following a brief summary of earlier work directed to refractive procedures in the mid-IR, a preliminary analysis is presented, based on simple one-dimensional models...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429958

    authors: Hoffman HJ,Telfair WB

    更新日期:1999-10-01 00:00:00

  • Influence of the phase function in generalized diffuse reflectance models: review of current formalisms and novel observations.

    abstract::Diffuse reflectance spectroscopy, which has been demonstrated as a noninvasive diagnostic technique, relies on quantitative models for extracting optical property values from turbid media, such as biological tissues. We review and compare reflectance models that have been published, and we test similar models over a m...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.19.7.075005

    authors: Calabro KW,Bigio IJ

    更新日期:2014-01-01 00:00:00

  • Depth profiling of photothermal compound concentrations using phase sensitive optical coherence tomography.

    abstract::A model that describes the concentration of photothermal (light-to-heat converters) compounds as a function of depth in a turbid medium is developed. The system consists of a pump laser (808 nm modulated at 400 Hz), which heats a photothermal compound, and a phase sensitive spectral domain optical coherence tomography...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3659211

    authors: Guan G,Reif R,Huang Z,Wang RK

    更新日期:2011-12-01 00:00:00

  • Diagnosis of oral submucous fibrosis with optical coherence tomography.

    abstract::The epithelium (EP) thickness and the standard deviation (SD) of A-mode scan intensity in the laminar propria (LP) layer are used as effective indicators for the diagnosis of oral submucous fibrosis (OSF) based on the noninvasive clinical scanning of a swept-source optical coherence tomography (OCT) system of approxim...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3233653

    authors: Lee CK,Tsai MT,Lee HC,Chen HM,Chiang CP,Wang YM,Yang CC

    更新日期:2009-09-01 00:00:00

  • Photoacoustic needle: minimally invasive guidance to biopsy.

    abstract::We introduce a needle probe based on photoacoustics (PA) to extend the scope of optical needle methods in guiding biopsies. Pulsed light is coupled to an optical fiber in a needle to be inserted in tissue, and PA signals are detected using an ultrasound imager used for needle guidance. This PA needle samples large vol...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.7.070502

    authors: Piras D,Grijsen C,Schütte P,Steenbergen W,Manohar S

    更新日期:2013-07-01 00:00:00

  • Real-time in vivo photoacoustic and ultrasound imaging.

    abstract::A real-time photoacoustic imaging system is designed and built. This system is based on a commercially available ultrasound imaging system. It can achieve a frame rate of 8 frames/sec. Vasculature in the hand of a human volunteer is imaged, and the resulting photoacoustic image is combined with the ultrasound image. T...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3005421

    authors: Kolkman RG,Brands PJ,Steenbergen W,van Leeuwen TG

    更新日期:2008-09-01 00:00:00

  • Quantitative real-time optical imaging of the tissue metabolic rate of oxygen consumption.

    abstract::The tissue metabolic rate of oxygen consumption (tMRO2) is a clinically relevant marker for a number of pathologies including cancer and arterial occlusive disease. We present and validate a noncontact method for quantitatively mapping tMRO2 over a wide, scalable field of view at 16  frames  /  s. We achieve this by d...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.3.036013

    authors: Ghijsen M,Lentsch GR,Gioux S,Brenner M,Durkin AJ,Choi B,Tromberg BJ

    更新日期:2018-03-01 00:00:00

  • In-vivo Fourier domain optical coherence tomography as a new tool for investigation of vasodynamics in the mouse model.

    abstract::In-vivo imaging of the vascular system can provide novel insight into the dynamics of vasoconstriction and vasodilation. Fourier domain optical coherence tomography (FD-OCT) is an optical, noncontact imaging technique based on interferometry of short-coherent near-infrared light with axial resolution of less than 10 m...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3149865

    authors: Meissner S,Müller G,Walther J,Morawietz H,Koch E

    更新日期:2009-05-01 00:00:00

  • Comparison of cerebral oxygen saturation in premature infants by near-infrared spatially resolved spectroscopy: observations on probe-dependent bias.

    abstract::Spatially resolved spectroscopy (SRS) allows the estimation of absolute tissue oxygen saturation, the ratio of oxygenated to total hemoglobin concentration, which may facilitate the comparison of results among patients. Eighty-two premature infants were included over two years. The cerebral tissue oxygenation index (c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3013454

    authors: Sorensen LC,Leung TS,Greisen G

    更新日期:2008-11-01 00:00:00

  • Coregistered optical coherence tomography and frequency-encoded multispectral imaging for spectrally sparse color imaging.

    abstract::We present a system combining optical coherence tomography (OCT) and multispectral imaging (MSI) for coregistered structural imaging and surface color imaging. We first describe and numerically validate an optimization model to guide the selection of the MSI wavelengths and their relative intensities. We then demonstr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.3.032008

    authors: Attendu X,Bourget MH,de Sivry-Houle MP,Boudoux C

    更新日期:2019-11-01 00:00:00

  • Optimal probe design for breast imaging using near-infrared diffused light.

    abstract::Shallow lesions less than 1.5-cm deep are frequently seen in breast patients when they are scanned in reflection geometry. Two boundary conditions are compared for imaging shallow lesions, and a new probe design is introduced. A partial reflection boundary condition is suitable for imaging shallow lesions less than 1....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2966703

    authors: Xu C,Yuan B,Zhu Q

    更新日期:2008-07-01 00:00:00

  • Combining casein phosphopeptide-amorphous calcium phosphate with fluoride: synergistic remineralization potential of artificially demineralized enamel or not?

    abstract::Recaldent is a product of casein phosphopeptide-amorphous calcium phosphate (CPP-ACP). The remineralizing potential of CPP-ACP per se, or when combined with 0.22% Fl gel on artificially demineralized enamel using laser florescence, is investigated. Mesial surfaces of 15 sound human molars are tested using a He-Cd lase...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3210780

    authors: Elsayad I,Sakr A,Badr Y

    更新日期:2009-07-01 00:00:00

  • Oblique incidence reflectometry: optical models and measurements using a side-viewing gradient index lens-based endoscopic imaging system.

    abstract::A side-viewing, 2.3-mm diameter oblique incidence reflectometry endoscope has been designed to obtain optical property measurements of turbid samples. Light from a single-mode fiber is relayed obliquely onto the tissue with a gradient index lens-based distal optics assembly and the resulting diffuse reflectance profil...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.6.067002

    authors: Wall RA,Barton JK

    更新日期:2014-06-01 00:00:00

  • Characterizing depth-dependent refractive index of articular cartilage subjected to mechanical wear or enzymic degeneration.

    abstract::Utilizing a laser scanning confocal microscope system, the refractive indices of articular cartilage (AC) with mechanical or biochemical degenerations were characterized to investigate whether potential correlations exist between refractive index (RI) and cartilage degeneration. The cartilage samples collected from th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.9.095002

    authors: Wang K,Wu J,Day R,Kirk TB,Hu X

    更新日期:2016-09-01 00:00:00

  • Three-beam spectral-domain optical coherence tomography for retinal imaging.

    abstract::A three-beam spectral domain optical coherence tomography system (OCT) whose center wavelength is 840 nm was developed. The three beams focus on fundus 3.1 mm apart from each other and are detected by a single line sensor. The distance between the beams is fixed and the beams scan a total area of 10×10  mm² while keep...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.10.106001

    authors: Suehira N,Ooto S,Hangai M,Matsumoto K,Tomatsu N,Yuasa T,Yamada K,Yoshimura N

    更新日期:2012-10-01 00:00:00

  • Adaptive optics for fluorescence wide-field microscopy using spectrally independent guide star and markers.

    abstract::We describe the implementation and use of an adaptive optics loop in the imaging path of a commercial wide field microscope. We show that it is possible to maintain the optical performances of the original microscope when imaging through aberrant biological samples. The sources used for illuminating the adaptive optic...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3603847

    authors: Vermeulen P,Muro E,Pons T,Loriette V,Fragola A

    更新日期:2011-07-01 00:00:00

  • Machine learning approach for rapid and accurate estimation of optical properties using spatial frequency domain imaging.

    abstract::Fast estimation of optical properties from reflectance measurements at two spatial frequencies could pave way for real-time, wide-field and quantitative mapping of vital signs of tissues. We present a machine learning-based approach for estimating optical properties in the spatial frequency domain, where a random fore...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.7.071606

    authors: Panigrahi S,Gioux S

    更新日期:2018-12-01 00:00:00

  • Time-resolved diffuse optical tomography and its application to in vitro and in vivo imaging.

    abstract::This work reviews our research during the past several years on time-resolved (TR) near-infrared diffuse optical tomography (DOT). Following an introduction of the measuring modes, two proposed schemes of image reconstruction in TR-DOT are described: one utilizes the full TR data, and the other, referred to as the mod...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.2815724

    authors: Zhao H,Gao F,Tanikawa Y,Yamada Y

    更新日期:2007-11-01 00:00:00

  • Determination of optical properties of human blood in the spectral range 250 to 1100 nm using Monte Carlo simulations with hematocrit-dependent effective scattering phase functions.

    abstract::The absorption coefficient mu(a), scattering coefficient mu(s), and anisotropy factor g of diluted and undiluted human blood (hematocrit 0.84 and 42.1%) are determined under flow conditions in the wavelength range 250 to 1100 nm, covering the absorption bands of hemoglobin. These values are obtained by high precision ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2203659

    authors: Friebel M,Roggan A,Müller G,Meinke M

    更新日期:2006-05-01 00:00:00

  • Measuring the dynamics of cyclic adenosine monophosphate level in living cells induced by low-level laser irradiation using bioluminescence resonance energy transfer.

    abstract::Several studies demonstrated that the cyclic adenosine monophosphate (cAMP), an important second messenger, is involved in the mechanism of low-level laser irradiation (LLLI) treatment. However, most of these studies obtained the cAMP level in cell culture extracts or supernatant. In this study, the cAMP level in livi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.5.051029

    authors: Huang Y,Zheng L,Yang H,Chen J,Wang Y,Li H,Xie S,Zeng H

    更新日期:2015-05-01 00:00:00

  • Holographic laser Doppler imaging of pulsatile blood flow.

    abstract::We report on wide-field imaging of pulsatile motion induced by blood flow using heterodyne holographic interferometry on the thumb of a healthy volunteer, in real time. Optical Doppler images were measured with green laser light by a frequency-shifted Mach-Zehnder interferometer in off-axis configuration. The recorded...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.6.066006

    authors: Bencteux J,Pagnoux P,Kostas T,Bayat S,Atlan M

    更新日期:2015-06-01 00:00:00

  • Closure of skin incisions by laser-welding with a combination of two near-infrared diode lasers: preliminary study for determination of optimal parameters.

    abstract::Laser welding has the potential to become an effective method for wound closure and healing without sutures. Closure of skin incisions by laser welding with a combination of two near-infrared lasers (980 and 1064 nm), was performed for the first time in this study. One centimeter long, full-thickness incisions were ma...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3552648

    authors: Hu L,Lu Z,Wang B,Cao J,Ma X,Tian Z,Gao Z,Qin L,Wu X,Liu Y,Wang L

    更新日期:2011-03-01 00:00:00

  • Assessment of inflow and washout of indocyanine green in the adult human brain by monitoring of diffuse reflectance at large source-detector separation.

    abstract::Recently, it was shown in measurements carried out on humans that time-resolved near-infrared reflectometry and fluorescence spectroscopy may allow for discrimination of information originating directly from the brain avoiding influence of contaminating signals related to the perfusion of extracerebral tissues. We rep...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3574018

    authors: Liebert A,Sawosz P,Milej D,Kacprzak M,Weigl W,Botwicz M,Maczewska J,Fronczewska K,Mayzner-Zawadzka E,Królicki L,Maniewski R

    更新日期:2011-04-01 00:00:00

  • Quantitative phase microscopy of articular chondrocyte dynamics by wide-field digital interferometry.

    abstract::We experimentally implement label-free phase microscopy using wide-field digital interferometry (WFDI) techniques to retrieve quantitative volumetric data of articular chondrocyte dynamics. Using the scanless interferometric system, we visualize chondrocyte swelling and bursting induced by hypo-osmotic pressure. Recon...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3290242

    authors: Shaked NT,Finan JD,Guilak F,Wax A

    更新日期:2010-01-01 00:00:00