Coregistered optical coherence tomography and frequency-encoded multispectral imaging for spectrally sparse color imaging.

Abstract:

:We present a system combining optical coherence tomography (OCT) and multispectral imaging (MSI) for coregistered structural imaging and surface color imaging. We first describe and numerically validate an optimization model to guide the selection of the MSI wavelengths and their relative intensities. We then demonstrate the integration of this model into an all-fiber bench-top system. We implement frequency-domain multiplexing for the MSI to enable concurrent acquisition of both OCT and MSI at OCT acquisition rates. Such a system could be implemented in endoscopic practices to provide multimodal, high-resolution imaging of deep organ structures that are currently inaccessible to standard video endoscopes.

journal_name

J Biomed Opt

authors

Attendu X,Bourget MH,de Sivry-Houle MP,Boudoux C

doi

10.1117/1.JBO.25.3.032008

subject

Has Abstract

pub_date

2019-11-01 00:00:00

pages

1-12

issue

3

eissn

1083-3668

issn

1560-2281

pii

JBO-190223SSR

journal_volume

25

pub_type

杂志文章
  • Nanophotothermolysis of multiple scattered cancer cells with carbon nanotubes guided by time-resolved infrared thermal imaging.

    abstract::Nanophotothermolysis with long laser pulses for treatment of scattered cancer cells and their clusters is introduced with the main focus on real-time monitoring of temperature dynamics inside and around individual cancer cells labeled with carbon nanotubes. This technique utilizes advanced time- and spatially-resolved...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3119135

    authors: Biris AS,Boldor D,Palmer J,Monroe WT,Mahmood M,Dervishi E,Xu Y,Li Z,Galanzha EI,Zharov VP

    更新日期:2009-03-01 00:00:00

  • New laryngoscope for quantitative high-speed imaging of human vocal folds vibration in the horizontal and vertical direction.

    abstract::We report the design of a novel laser line-triangulation laryngoscope for the quantitative visualization of the three-dimensional movements of human vocal folds during phonation. This is the first successful in vivo recording of the three-dimensional movements of human vocal folds in absolute values. Triangulation ima...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3041164

    authors: George NA,de Mul FF,Qiu Q,Rakhorst G,Schutte HK

    更新日期:2008-11-01 00:00:00

  • Polarization birefringence measurements for characterizing the myocardium, including healthy, infarcted, and stem-cell-regenerated tissues.

    abstract::Myocardial infarction leads to structural remodeling of the myocardium, in particular to the loss of cardiomyocytes due to necrosis and an increase in collagen with scar formation. Stem cell regenerative treatments have been shown to alter this remodeling process, resulting in improved cardiac function. As healthy myo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3469844

    authors: Wood MF,Ghosh N,Wallenburg MA,Li SH,Weisel RD,Wilson BC,Li RK,Vitkin IA

    更新日期:2010-07-01 00:00:00

  • Distinguishing autofluorescence of normal, benign, and cancerous breast tissues through wavelet domain correlation studies.

    abstract::Using the multiresolution ability of wavelets and effectiveness of singular value decomposition (SVD) to identify statistically robust parameters, we find a number of local and global features, capturing spectral correlations in the co- and cross-polarized channels, at different scales (of human breast tissues). The c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3606563

    authors: Gharekhan AH,Arora S,Oza AN,Sureshkumar MB,Pradhan A,Panigrahi PK

    更新日期:2011-08-01 00:00:00

  • Bipolar cellular morphology of malignant melanoma in unstained human melanoma skin tissue.

    abstract::Microstructures of unstained human melanoma skin tissues have been examined by multimodal nonlinear optical microscopy. The polarized shape of the individual melanoma cell can be readily recognized-a phenotype that has been identified in laboratory cultures as characteristic of proliferating melanocytes but has not be...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3120491

    authors: Zhang K,Zhang W,Yang CY,Yang H

    更新日期:2009-03-01 00:00:00

  • Distinguishing tracheal and esophageal tissues with hyperspectral imaging and fiber-optic sensing.

    abstract::During emergency medical situations, where the patient has an obstructed airway or necessitates respiratory support, endotracheal intubation (ETI) is the medical technique of placing a tube into the trachea in order to facilitate adequate ventilation of the lungs. Complications during ETI, such as repeated attempts, f...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.11.117004

    authors: Nawn CD,Souhan BE,Carter R 3rd,Kneapler C,Fell N,Ye JY

    更新日期:2016-11-01 00:00:00

  • Monitoring remineralization of enamel subsurface lesions by optical coherence tomography.

    abstract::Optical coherence tomography (OCT) is a potential clinical tool for enamel lesion monitoring. Swept-source OCT findings were compared with cross-sectional nanohardness findings of enamel. Subsurface bovine enamel lesions in three groups were subjected to (1) deionized water (control), (2) phosphoryl oligosaccharide of...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.4.046006

    authors: Mandurah MM,Sadr A,Shimada Y,Kitasako Y,Nakashima S,Bakhsh TA,Tagami J,Sumi Y

    更新日期:2013-04-01 00:00:00

  • Two-photon imaging using adaptive phase compensated ultrashort laser pulses.

    abstract::An adaptive pulse shaper controlled by multiphoton intrapulse interference phase scanning (MIIPS) was used, together with a prism-pair, to measure and cancel high-order phase distortions introduced by a high-numerical-aperture objective and other dispersive elements of a two-photon laser-scanning microscope. The deliv...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3059629

    authors: Xi P,Andegeko Y,Pestov D,Lovozoy VV,Dantus M

    更新日期:2009-01-01 00:00:00

  • Real-time measurement of the vaginal pressure profile using an optical-fiber-based instrumented speculum.

    abstract::Pelvic organ prolapse (POP) occurs when changes to the pelvic organ support structures cause descent or herniation of the pelvic organs into the vagina. Clinical evaluation of POP is a series of manual measurements known as the pelvic organ prolapse quantification (POP-Q) score. However, it fails to identify the mecha...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.127008

    authors: Parkinson LA,Gargett CE,Young N,Rosamilia A,Vashi AV,Werkmeister JA,Papageorgiou AW,Arkwright JW

    更新日期:2016-12-01 00:00:00

  • Mapping local optical axis in birefringent samples using polarization-sensitive optical coherence tomography.

    abstract::An algorithm was developed to obtain depth-resolved local optical axis in birefringent samples by using conventional polarization-sensitive optical coherence tomography (PSOCT) that uses a single circularly polarized incident light. The round-trip sample Jones matrices were first constructed from the cumulative PSOCT ...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.17.11.110501

    authors: Fan C,Yao G

    更新日期:2012-11-01 00:00:00

  • Modulation transfer function measurement of scanning reflectance microscopes.

    abstract::Real-time medical imaging systems such as reflectance confocal microscopes and optical coherence microscopes are being tested in multiple-patient and multiple-center clinical trials. The modulation transfer function (MTF) of these systems at any given time influences the image information content and can affect the in...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2779352

    authors: Wang Z,Glazowski CE,Zavislan JM

    更新日期:2007-09-01 00:00:00

  • Analyzing near-infrared scattering from human skin to monitor changes in hematocrit.

    abstract::Probing tissue with near-infrared radiation (NIR) simultaneously produces remitted fluorescence and Raman scattering (IE) plus Rayleigh∕Mie light scattering (EE) that noninvasively give chemical and physical information about the materials and objects within. We model tissue as a three-phase system: plasma and red blo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3625283

    authors: Chaiken J,Deng B,Goodisman J,Shaheen G,Bussjager RJ

    更新日期:2011-09-01 00:00:00

  • Intraoperative hyperspectral determination of human tissue properties.

    abstract::We address the automatic differentiation of human tissue using multispectral imaging with promising potential for automatic visualization during surgery. Currently, tissue types have to be continuously differentiated based on the surgeon's knowledge only. Further, automatic methods based on optical in vivo properties ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.9.091409

    authors: Wisotzky EL,Uecker FC,Arens P,Dommerich S,Hilsmann A,Eisert P

    更新日期:2018-05-01 00:00:00

  • Navigation of a robot-integrated fluorescence laparoscope in preoperative SPECT/CT and intraoperative freehand SPECT imaging data: a phantom study.

    abstract::Robot-assisted laparoscopic surgery is becoming an established technique for prostatectomy and is increasingly being explored for other types of cancer. Linking intraoperative imaging techniques, such as fluorescence guidance, with the three-dimensional insights provided by preoperative imaging remains a challenge. Na...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.8.086008

    authors: van Oosterom MN,Engelen MA,van den Berg NS,KleinJan GH,van der Poel HG,Wendler T,van de Velde CJ,Navab N,van Leeuwen FW

    更新日期:2016-08-01 00:00:00

  • Design of synchrotron light source and its beamline dedicated to dual-energy x-ray computed tomography.

    abstract::A synchrotron light source dedicated to medical applications has been designed at National Institute of Radiological Sciences. The storage ring, with circumference of 80 m, is designed for acceleration of 2.3 GeV and a stored current of 420 mA. It is equipped with two multipole wigglers to produce sufficient photon fl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1383062

    authors: Torikoshi M,Tsunoo T,Endo M,Noda K,Kumada M,Yamada S,Soga F,Hyodo K

    更新日期:2001-07-01 00:00:00

  • Real-time microscopic visualization of tissue response to laser thermal therapy.

    abstract::We present methods for visualizing the dynamic response of biological samples to laser-induced heating. Our approach utilizes optical frequency-domain imaging to detect, spatially localize, and monitor unique dynamic signatures that arise within zones of active tissue denaturation. Since this information is precisely ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714027

    authors: Vakoc BJ,Tearney GJ,Bouma BE

    更新日期:2007-03-01 00:00:00

  • Reflection spectroscopy of atherosclerotic plaque.

    abstract::Heart disease is the primary cause of death in the western world. Many of these deaths are caused by the rupture of vulnerable plaque. Vulnerable plaques are characterized by a large lipid core covered by a thin fibrous cap. One method for detecting these plaques is reflection spectroscopy. Several studies have invest...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2186332

    authors: Lilledahl MB,Haugen OA,Barkost M,Svaasand LO

    更新日期:2006-03-01 00:00:00

  • Evaluation and quantification of spectral information in tissue by confocal microscopy.

    abstract::A confocal imaging and image processing scheme is introduced to visualize and evaluate the spatial distribution of spectral information in tissue. The image data are recorded using a confocal laser-scanning microscope equipped with a detection unit that provides high spectral resolution. The processing scheme is based...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.10.106011

    authors: Maeder U,Marquardt K,Beer S,Bergmann T,Schmidts T,Heverhagen JT,Zink K,Runkel F,Fiebich M

    更新日期:2012-10-01 00:00:00

  • Fiber optic biosensor for the detection of C-reactive protein and the study of protein binding kinetics.

    abstract::Application of a fiber optic biosensor (FOB) to the real-time investigation of the interaction kinetics between FITC-conjugated monoclonal sheep anti-human C-reactive protein (CRP) antibody and CRP isoforms on the surface of optical fiber is described. Recently, both the native pentameric CRP (pCRP), an acute phase pr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714029

    authors: Chou C,Hsu HY,Wu HT,Tseng KY,Chiou A,Yu CJ,Lee ZY,Chan TS

    更新日期:2007-03-01 00:00:00

  • Early detection of colorectal cancer relapse by infrared spectroscopy in "normal" anastomosis tissue.

    abstract::Colorectal cancer is one of the most aggressive cancers usually occurring in people above the age of 50 years. In the United States, colorectal cancer is the third most diagnosed cancer. The American Cancer Society has estimated 96,830 new cases of colon cancer and 40,000 new cases of rectal cancer in 2014 in the Unit...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.7.075007

    authors: Salman A,Sebbag G,Argov S,Mordechai S,Sahu RK

    更新日期:2015-07-01 00:00:00

  • Label-free separation of human embryonic stem cells and their differentiating progenies by phasor fluorescence lifetime microscopy.

    abstract::We develop a label-free optical technique to image and discriminate undifferentiated human embryonic stem cells (hESCs) from their differentiating progenies in vitro. Using intrinsic cellular fluorophores, we perform fluorescence lifetime microscopy (FLIM) and phasor analysis to obtain hESC metabolic signatures. We id...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.4.046012

    authors: Stringari C,Sierra R,Donovan PJ,Gratton E

    更新日期:2012-04-01 00:00:00

  • Investigation of nuclear nano-morphology marker as a biomarker for cancer risk assessment using a mouse model.

    abstract::The development of accurate and clinically applicable tools to assess cancer risk is essential to define candidates to undergo screening for early-stage cancers at a curable stage or provide a novel method to monitor chemoprevention treatments. With the use of our recently developed optical technology--spatial-domain ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.6.066014

    authors: Bista RK,Uttam S,Hartman DJ,Qiu W,Yu J,Zhang L,Brand RE,Liu Y

    更新日期:2012-06-01 00:00:00

  • Angiography with a multifunctional line scanning ophthalmoscope.

    abstract::A multifunctional line scanning ophthalmoscope (mLSO) was designed, constructed, and tested on human subjects. The mLSO could sequentially acquire wide-field, confocal, near-infrared reflectance, fluorescein angiography (FA), and indocyanine green angiography (ICGA) retinal images. The system also included a retinal t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.2.026008

    authors: Hammer DX,Ferguson RD,Patel AH,Vazquez V,Husain D

    更新日期:2012-02-01 00:00:00

  • Quantitative performance characterization of three-dimensional noncontact fluorescence molecular tomography.

    abstract::Fluorescent proteins and dyes are routine tools for biological research to describe the behavior of genes, proteins, and cells, as well as more complex physiological dynamics such as vessel permeability and pharmacokinetics. The use of these probes in whole body in vivo imaging would allow extending the range and scop...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.2.026009

    authors: Favicchio R,Psycharakis S,Schönig K,Bartsch D,Mamalaki C,Papamatheakis J,Ripoll J,Zacharakis G

    更新日期:2016-02-01 00:00:00

  • Assessment of inflow and washout of indocyanine green in the adult human brain by monitoring of diffuse reflectance at large source-detector separation.

    abstract::Recently, it was shown in measurements carried out on humans that time-resolved near-infrared reflectometry and fluorescence spectroscopy may allow for discrimination of information originating directly from the brain avoiding influence of contaminating signals related to the perfusion of extracerebral tissues. We rep...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3574018

    authors: Liebert A,Sawosz P,Milej D,Kacprzak M,Weigl W,Botwicz M,Maczewska J,Fronczewska K,Mayzner-Zawadzka E,Królicki L,Maniewski R

    更新日期:2011-04-01 00:00:00

  • Image reconstruction in photoacoustic tomography with variable speed of sound using a higher-order geometrical acoustics approximation.

    abstract::Previous research correcting for variable speed of sound in photoacoustic tomography (PAT) based on a generalized radon transform (GRT) model assumes first-order geometrical acoustics (GA) approximation. In the GRT model, the pressure is related to the optical absorption, in an acoustically inhomogeneous medium, throu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3333550

    authors: Modgil D,Anastasio MA,La Rivière PJ

    更新日期:2010-03-01 00:00:00

  • Time-dependent blood flow and oxygenation in human skeletal muscles measured with noninvasive near-infrared diffuse optical spectroscopies.

    abstract::We have employed near-infrared optical methods to measure noninvasively the dynamics of muscle blood flow and oxygen saturation (StO2) during cuff occlusion and plantar flexion exercise. Relative muscle oxygen consumption (rVO2) was also computed from these data. Diffuse correlation spectroscopy provides information a...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1884603

    authors: Yu G,Durduran T,Lech G,Zhou C,Chance B,Mohler ER 3rd,Yodh AG

    更新日期:2005-03-01 00:00:00

  • Retinal response of Macaca mulatta to picosecond laser pulses of varying energy and spot size.

    abstract::We investigate the relationship between the laser beam at the retina (spot size) and the extent of retinal injury from single ultrashort laser pulses. From previous studies it is believed that the retinal effect of single 3-ps laser pulses should vary in extent and location, depending on the occurrence of laser-induce...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1805554

    authors: Roach WP,Cain CP,Narayan DG,Noojin GD,Boppart SA,Birngruber R,Fujimoto JG,Toth CA

    更新日期:2004-11-01 00:00:00

  • Ultrasonic standing wave preparation of a liquid cell for glucose measurements in urine by midinfrared spectroscopy and potential application to smart toilets.

    abstract::Smart toilets could be used to monitor different components of urine in daily life for early detection of lifestyle-related diseases and prompt provision of treatment. For analysis of biological samples such as urine by midinfrared spectroscopy, thin-film samples like liquid cells are needed because of the strong abso...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.23.5.050503

    authors: Yamamoto N,Kawashima N,Kitazaki T,Mori K,Kang H,Nishiyama A,Wada K,Ishimaru I

    更新日期:2018-05-01 00:00:00

  • Measurement of oxygen saturation in small retinal vessels with adaptive optics confocal scanning laser ophthalmoscope.

    abstract::We have used an adaptive optics confocal scanning laser ophthalmoscope to assess oxygen saturation in small retinal vessels. Images of the vessels with a diameter smaller than 50 μm are recorded at oxygen sensitive and isosbestic wavelengths (680 and 796 nm, respectively). The vessel optical densities (ODs) are determ...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3655354

    authors: Li H,Lu J,Shi G,Zhang Y

    更新日期:2011-11-01 00:00:00