Image reconstruction in photoacoustic tomography with variable speed of sound using a higher-order geometrical acoustics approximation.

Abstract:

:Previous research correcting for variable speed of sound in photoacoustic tomography (PAT) based on a generalized radon transform (GRT) model assumes first-order geometrical acoustics (GA) approximation. In the GRT model, the pressure is related to the optical absorption, in an acoustically inhomogeneous medium, through integration over nonspherical isochronous surfaces. Previous research based on the GRT model assumes that the path taken by acoustic rays is linear and neglects amplitude perturbations to the measured pressure. We have derived a higher-order GA expression that takes into account the first-order effect in the amplitude of the measured signal and higher-order perturbation to the travel times. The higher-order perturbation to travel time incorporates the effect of ray bending. Incorrect travel times can lead to image distortion and blurring. These corrections are expected to impact image quality and quantitative PAT. We have previously shown that travel-time corrections in 2-D suggest that perceivable differences in the isochronous surfaces can be seen when the second-order travel-time perturbations are taken into account with a 10% speed-of-sound variation. In this work, we develop iterative image reconstruction algorithms that incorporate this higher-order GA approximation assuming that the speed of sound map is known. We evaluate the effect of higher-order GA approximation on image quality and accuracy.

journal_name

J Biomed Opt

authors

Modgil D,Anastasio MA,La Rivière PJ

doi

10.1117/1.3333550

subject

Has Abstract

pub_date

2010-03-01 00:00:00

pages

021308

issue

2

eissn

1083-3668

issn

1560-2281

journal_volume

15

pub_type

杂志文章
  • Virtual organelle self-coding for fluorescence imaging via adversarial learning.

    abstract:SIGNIFICANCE:Our study introduces an application of deep learning to virtually generate fluorescence images to reduce the burdens of cost and time from considerable effort in sample preparation related to chemical fixation and staining. AIM:The objective of our work was to determine how successfully deep learning meth...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.9.096009

    authors: Nguyen T,Bui V,Thai A,Lam V,Raub C,Chang LC,Nehmetallah G

    更新日期:2020-09-01 00:00:00

  • Detection of intramyocardial scroll waves using absorptive transillumination imaging.

    abstract::Optical imaging using voltage-sensitive dyes has become an important tool for studying vortex-like electrical waves in the heart. Such waves, known as spiral or scroll waves, can spontaneously form in pathological ventricular myocardium, causing ventricular fibrillation and sudden death. Until recently, observations o...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2709661

    authors: Bernus O,Mukund KS,Pertsov AM

    更新日期:2007-01-01 00:00:00

  • Differential optical spectropolarimetric imaging system assisted by liquid crystal devices for skin imaging.

    abstract::Skin cancer diagnosis depends not only on histopathological examination but also on visual inspection before and after the excision of suspected lesion. Neoplasm is accompanied with changes in birefringence of collagen, pleomorphicity, and hyperchromatic state of epithelial nuclei. These phenomena can be measured by s...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3609003

    authors: Aharon O,Abdulhalim I,Arnon O,Rosenberg L,Dyomin V,Silberstein E

    更新日期:2011-08-01 00:00:00

  • Noninvasive assessment of diabetic foot ulcers with diffuse photon density wave methodology: pilot human study.

    abstract::A pilot human study is conducted to evaluate the potential of using diffuse photon density wave (DPDW) methodology at near-infrared (NIR) wavelengths (685 to 830 nm) to monitor changes in tissue hemoglobin concentration in diabetic foot ulcers. Hemoglobin concentration is measured by DPDW in 12 human wounds for a peri...

    journal_title:Journal of biomedical optics

    pub_type: 临床试验,杂志文章

    doi:10.1117/1.3275467

    authors: Papazoglou ES,Neidrauer M,Zubkov L,Weingarten MS,Pourrezaei K

    更新日期:2009-11-01 00:00:00

  • Evaluation and quantification of spectral information in tissue by confocal microscopy.

    abstract::A confocal imaging and image processing scheme is introduced to visualize and evaluate the spatial distribution of spectral information in tissue. The image data are recorded using a confocal laser-scanning microscope equipped with a detection unit that provides high spectral resolution. The processing scheme is based...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.10.106011

    authors: Maeder U,Marquardt K,Beer S,Bergmann T,Schmidts T,Heverhagen JT,Zink K,Runkel F,Fiebich M

    更新日期:2012-10-01 00:00:00

  • Dialysis-assisted fiber optic spectroscopy for in situ biomedical sensing.

    abstract::A miniature fiber optic spectrometer enclosed within a semipermeable (dialysis) membrane is proposed for in vivo interstitial sensing applications. The semipermeable membrane acts as a molecular filter, allowing only small molecules to pass through to the sampling volume. This filtering, in principle, should enable co...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2166086

    authors: Blazkiewicz P,Blazkiewicz K,Verhaege A,Anissimov YG,Roberts MS,Zvyagin AV

    更新日期:2006-01-01 00:00:00

  • On the noninvasive optical monitoring and differentiation of methemoglobinemia and sulfhemoglobinemia.

    abstract::There are several pathologies whose study and diagnosis is impaired by a relatively small number of documented cases. A practical approach to overcome this obstacle and advance the research in this area consists in employing computer simulations to perform controlled in silico experiments. The results of these experim...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.9.097005

    authors: Baranoski GV,Chen TF,Kimmel BW,Miranda E,Yim D

    更新日期:2012-09-01 00:00:00

  • Optical fiber-based dispersion for spectral discrimination in fluorescence lifetime imaging systems.

    abstract::The excited state lifetime of a fluorophore together with its fluorescence emission spectrum provide information that can yield valuable insights into the nature of a fluorophore and its microenvironment. However, it is difficult to obtain both channels of information in a conventional scheme as detectors are typicall...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.1.014506

    authors: Sagar MAK,Dai B,Chacko J,Weber J,Velten A,Sanders S,White J,Eliceiri K

    更新日期:2019-12-01 00:00:00

  • Graphics processing unit-based dispersion encoded full-range frequency-domain optical coherence tomography.

    abstract::Dispersion encoded full-range (DEFR) frequency-domain optical coherence tomography (FD-OCT) and its enhanced version, fast DEFR, utilize dispersion mismatch between sample and reference arm to eliminate the ambiguity in OCT signals caused by non-complex valued spectral measurement, thereby numerically doubling the usa...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.077007

    authors: Wang L,Hofer B,Guggenheim JA,Povazay B

    更新日期:2012-07-01 00:00:00

  • Calibration of diffuse correlation spectroscopy blood flow index with venous-occlusion diffuse optical spectroscopy in skeletal muscle.

    abstract::We investigate and assess the utility of a simple scheme for continuous absolute blood flow monitoring based on diffuse correlation spectroscopy (DCS). The scheme calibrates DCS using venous-occlusion diffuse optical spectroscopy (VO-DOS) measurements of arm muscle tissue at a single time-point. A calibration coeffici...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.12.125005

    authors: Li Z,Baker WB,Parthasarathy AB,Ko TS,Wang D,Schenkel S,Durduran T,Li G,Yodh AG

    更新日期:2015-01-01 00:00:00

  • Near-infrared light-responsive liposomal contrast agent for photoacoustic imaging and drug release applications.

    abstract::Photoacoustic imaging has become an emerging tool for theranostic applications. Not only does it help in

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.4.041007

    authors: Sivasubramanian K,Mathiyazhakan M,Wiraja C,Upputuri PK,Xu C,Pramanik M

    更新日期:2017-04-01 00:00:00

  • Infrared spectroscopic analysis of human and bovine articular cartilage proteoglycans using carbohydrate peak or its second derivative.

    abstract::Fourier transform infrared (FTIR) microspectroscopy has been used to estimate the spatial proteoglycan (PG) and collagen contents in articular cartilage (AC). However, it is not clear whether the results of FTIR analyses are consistent between different species. Our aim was to clarify how three different FTIR PG param...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.9.097006

    authors: Rieppo L,Närhi T,Helminen HJ,Jurvelin JS,Saarakkala S,Rieppo J

    更新日期:2013-09-01 00:00:00

  • Optically sectioned in vivo imaging with speckle illumination HiLo microscopy.

    abstract::We present a simple wide-field imaging technique, called HiLo microscopy, that is capable of producing optically sectioned images in real time, comparable in quality to confocal laser scanning microscopy. The technique is based on the fusion of two raw images, one acquired with speckle illumination and another with st...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3528656

    authors: Lim D,Ford TN,Chu KK,Mertz J

    更新日期:2011-01-01 00:00:00

  • Hyperspectral imaging based method for fast characterization of kidney stone types.

    abstract::The formation of kidney stones is a common and highly studied disease, which causes intense pain and presents a high recidivism. In order to find the causes of this problem, the characterization of the main compounds is of great importance. In this sense, the analysis of the composition and structure of the stone can ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.076027

    authors: Blanco F,López-Mesas M,Serranti S,Bonifazi G,Havel J,Valiente M

    更新日期:2012-07-01 00:00:00

  • Swept-source optical coherence tomography powered by a 1.3-μm vertical cavity surface emitting laser enables 2.3-mm-deep brain imaging in mice in vivo.

    abstract::We report noninvasive, in vivo optical imaging deep within a mouse brain by swept-source optical coherence tomography (SS-OCT), enabled by a 1.3-μm vertical cavity surface emitting laser (VCSEL). VCSEL SS-OCT offers a constant signal sensitivity of 105 dB throughout an entire depth of 4.25 mm in air, ensuring an exten...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.10.106004

    authors: Choi WJ,Wang RK

    更新日期:2015-10-01 00:00:00

  • Discovery of the near-infrared window into the body and the early development of near-infrared spectroscopy.

    abstract::Extension of optical monitoring of intact tissues from the visible and ultraviolet to the near-infrared (NIR) range (700-1300 nm) was first undertaken in 1977 for the purpose of monitoring the redox behavior of Cytochrome c oxidase (cyt c ox) in vivo. Soon it became evident that the much greater NIR translucency of sk...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429952

    authors: Jo Bsis-Vandervliet FF

    更新日期:1999-10-01 00:00:00

  • Study of the influence of over-the-counter vitamin supplement intake on urine fluorescence to optimize cancer detection by fluorescence cystoscopy.

    abstract::Fluorescence cystoscopy (FC) efficiently enhances the detection and improves the therapeutic management of early bladder cancer. During an FC, about 150 ml of water is needed to inflate the bladder. The water is quickly diluted by urine which can be fluorescent. If this bladder washout fluid (BWF) becomes fluorescent,...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.6.066011

    authors: Zellweger M,Martoccia C,Mengin M,Iselin C,van den Bergh H,Wagnières G

    更新日期:2015-06-01 00:00:00

  • Human graft cornea and laser incisions imaging with micrometer scale resolution full-field optical coherence tomography.

    abstract::Micrometer scale resolution full-field optical coherence tomography (FF-OCT) is developed for imaging human graft corneas. Three-dimensional (3-D) images with ultrahigh resolution (respectively, 1 and 1.5 μm in the axial and transverse directions), comparable to traditional histological sections, are obtained allowing...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3486544

    authors: Latour G,Georges G,Lamoine LS,Deumié C,Conrath J,Hoffart L

    更新日期:2010-09-01 00:00:00

  • Monte Carlo simulations related to gas-based optical diagnosis of human sinusitis.

    abstract::We investigate the feasibility of using diode laser gas spectroscopy for sinusitis diagnostics. We simulate light propagation using the Monte Carlo concept, as implemented by the Advanced Systems Analysis Program (ASAP) software. Simulations and experimental data are compared for a model based on two scattering bodies...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2777179

    authors: Persson L,Kristensson E,Simonsson L,Svanberg S

    更新日期:2007-09-01 00:00:00

  • Methodology for examining polarized light interactions with tissues and tissuelike media in the exact backscattering direction.

    abstract::The properties of polarized light emerging from turbid media in the exact backscattering direction are studied by modulating the incident light polarization state and isolating the synchronous signal with lock-in amplifier detection. The results are reported for polystyrene microsphere suspensions in distilled water, ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.430004

    authors: Studinski RC,Vitkin IA

    更新日期:2000-07-01 00:00:00

  • Simulating the scanning of a focused beam through scattering media using a numerical solution of Maxwell's equations.

    abstract::A highly efficient method based on Maxwell's theory was developed, which enables the calculation of the scanning of a focused beam through scattering media. Maxwell's equations were numerically solved in two dimensions using finite difference time domain simulations. The modeling of the focused beam was achieved by ap...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.7.071404

    authors: Elmaklizi A,Schäfer J,Kienle A

    更新日期:2014-07-01 00:00:00

  • Photon migration through fetal head in utero using continuous wave, near-infrared spectroscopy: development and evaluation of experimental and numerical models.

    abstract::In this work experimental tissue phantoms and numerical models were developed to estimate photon migration through the fetal head in utero. The tissue phantoms incorporate a fetal head within an amniotic fluid sac surrounded by a maternal tissue layer. A continuous wave, dual-wavelength (lambda = 760 and 850 nm) spect...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429983

    authors: Vishnoi G,Hielscher AH,Ramanujam N,Chance B

    更新日期:2000-04-01 00:00:00

  • Measurement of the refractive index of whole blood and its components for a continuous spectral region.

    abstract::The refractive index of blood is a key biophysical parameter, which can reflect the physiological state. We measured the refractive index of whole blood and other components, such as serum, plasma, and hemoglobin, based on internal reflection by using a homemade apparatus in the spectral range of 400 to 750 nm. In add...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.3.035003

    authors: Liu S,Deng Z,Li J,Wang J,Huang N,Cui R,Zhang Q,Mei J,Zhou W,Zhang C,Ye Q,Tian J

    更新日期:2019-03-01 00:00:00

  • Video-rate optical flow corrected intraoperative functional fluorescence imaging.

    abstract::Intraoperative fluorescence molecular imaging based on targeted fluorescence agents is an emerging approach to improve surgical and endoscopic imaging and guidance. Short exposure times per frame and implementation at video rates are necessary to provide continuous feedback to the physician and avoid motion artifacts....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.4.046012

    authors: Koch M,Glatz J,Ermolayev V,de Vries EG,van Dam GM,Englmeier KH,Ntziachristos V

    更新日期:2014-04-01 00:00:00

  • Quantitative concentration measurements of creatinine dissolved in water and urine using Raman spectroscopy and a liquid core optical fiber.

    abstract::We describe the use of a Teflon-AF liquid core optical fiber (LCOF) geometry to enhance the collection of Raman scattering from the biochemical creatinine, dissolved in water and in urine. At short integration times, where shot noise is most troublesome, the enhanced signal leads to greater accuracy in estimating the ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1917842

    authors: Qi D,Berger AJ

    更新日期:2005-05-01 00:00:00

  • In vivo near-infrared dual-axis confocal microendoscopy in the human lower gastrointestinal tract.

    abstract::Near-infrared confocal microendoscopy is a promising technique for deep in vivo imaging of tissues and can generate high-resolution cross-sectional images at the micron-scale. We demonstrate the use of a dual-axis confocal (DAC) near-infrared fluorescence microendoscope with a 5.5-mm outer diameter for obtaining clini...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.2.021102

    authors: Piyawattanametha W,Ra H,Qiu Z,Friedland S,Liu JT,Loewke K,Kino GS,Solgaard O,Wang TD,Mandella MJ,Contag CH

    更新日期:2012-02-01 00:00:00

  • Diabetic retinopathy assessed by dynamic light scattering and corneal autofluorescence.

    abstract::Autofluorescence of the cornea within specific wavelength region and dynamic light scattering measurements of ocular tissue have both been used for early-stage detection of the presence of diabetic retinopathy. In the present study, autofluorescence of the cornea and dynamic light scattering in the cornea and vitreous...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429882

    authors: Rovati L,Fankhauser F,Docchio F,Van Best J

    更新日期:1998-07-01 00:00:00

  • Modulation of an optical needle's reflectivity alters the average photon path through scattering media.

    abstract::We introduce the concept of deliberate placement of absorbers to alter the average path of photons through tissue for a biomedical optical device. By changing the reflectivity of a needle that separates a source and detector, the average photon path through a turbid medium can be changed. Totally reflective needles ha...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2168167

    authors: Simonson P,D'Amico E,Gratton E

    更新日期:2006-01-01 00:00:00

  • Impact of treatment response metrics on photodynamic therapy planning and outcomes in a three-dimensional model of ovarian cancer.

    abstract::Common methods to characterize treatment efficacy based on morphological imaging may misrepresent outcomes and exclude effective therapies. Using a three-dimensional model of ovarian cancer, two functional treatment response metrics are used to evaluate photodynamic therapy (PDT) efficacy: total volume, calculated fro...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.9.098004

    authors: Anbil S,Rizvi I,Celli JP,Alagic N,Pogue BW,Hasan T

    更新日期:2013-09-01 00:00:00

  • Early development of optical low-coherence reflectometry and some recent biomedical applications.

    abstract::This paper explains the term low-coherence interferometry, reviews the early development of optical low-coherence reflectometry, and shows some of the paths that led to the field of biomedical optics. This paper demonstrates that early technical developments in the telecommunications industry resulted in a myriad of t...

    journal_title:Journal of biomedical optics