Ultrasonic standing wave preparation of a liquid cell for glucose measurements in urine by midinfrared spectroscopy and potential application to smart toilets.

Abstract:

:Smart toilets could be used to monitor different components of urine in daily life for early detection of lifestyle-related diseases and prompt provision of treatment. For analysis of biological samples such as urine by midinfrared spectroscopy, thin-film samples like liquid cells are needed because of the strong absorption of midinfrared light by water. Conventional liquid cells or fixed cells are prepared based on the liquid membrane method and solution technique, but these are not quantitative and are difficult to set up and clean. We generated an ultrasonic standing wave reflection plane in a sample and produced an ultrasonic liquid cell. In this cell, the thickness of the optical path length was adjustable, as in the conventional method. The reflection plane could be generated at an arbitrary depth and internal reflected light could be detected by changing the frequency of the ultrasonic wave. We could generate refractive index boundaries using the density difference created by the ultrasonic standing wave. Creation of the reflection plane in the sample was confirmed by optical coherence tomography. Using the proposed method and midinfrared spectroscopy, we discriminated between normal urine samples spiked with glucose at different concentrations and obtained a high correlation coefficient.

journal_name

J Biomed Opt

authors

Yamamoto N,Kawashima N,Kitazaki T,Mori K,Kang H,Nishiyama A,Wada K,Ishimaru I

doi

10.1117/1.JBO.23.5.050503

subject

Has Abstract

pub_date

2018-05-01 00:00:00

pages

1-4

issue

5

eissn

1083-3668

issn

1560-2281

pii

JBO-170800LR

journal_volume

23

pub_type

信件
  • Hyperspectral wide gap second derivative analysis for in vivo detection of cervical intraepithelial neoplasia.

    abstract::Hyperspectral reflectance imaging technique has been used for in vivo detection of cervical intraepithelial neoplasia. However, the clinical outcome of this technique is suboptimal owing to multiple limitations such as nonuniform illumination, high-cost and bulky setup, and time-consuming data acquisition and processi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.12.121303

    authors: Zheng W,Wang C,Chang S,Zhang S,Xu RX

    更新日期:2015-12-01 00:00:00

  • Analysis of the spatial distribution of polarized light backscattered from layered scattering media.

    abstract::The scattering of polarized light from a two layer scattering medium is investigated using Monte Carlo simulations. First order and normalized second order moments are used to analyze the spatial properties of the emerging light in different polarization states. Linearly and circularly polarized illumination is used t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1483316

    authors: Stockford IM,Morgan SP,Chang PC,Walker JG

    更新日期:2002-07-01 00:00:00

  • Laser scoop desobliteration: a method for minimally invasive remote recanalization of chronically occluded superficial femoral arteries.

    abstract::Stenosis and occlusion of the superficial femoral artery (SFA) are most common in arterial occlusive disease. There are numerous interventional, surgical, and combined approaches to reconstitute maximum blood supply to the lower limb; however, despite intense clinical research, the long-term success rates are still po...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.2.025005

    authors: Heneweer C,Siggelkow M,Helle M,Petzina R,Wulff A,Schaefer JP,Berndt R,Rusch R,Wedel T,Klaws G,Müller-Gerbl M,Röcken C,Jansen O,Lutter G,Cremer J,Groß J

    更新日期:2015-02-01 00:00:00

  • Quality analysis of in vivo near-infrared fluorescence and conventional gamma images acquired using a dual-labeled tumor-targeting probe.

    abstract::The cyclic peptide, cyclopentapeptide cyclo(lys-Arg-Gly-Asp-phe) (c(KRGDf)), which is known to target alpha(v)beta3 integrin, is dual-labeled with a radiotracer, (111)indium, for gamma scintigraphy as well as with a near-infrared dye, IRDye800, for continuous-wave (cw) imaging of alpha(v)beta3 positive human M21 melan...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2114748

    authors: Houston JP,Ke S,Wang W,Li C,Sevick-Muraca EM

    更新日期:2005-09-01 00:00:00

  • Diagnostic performance of receptor-specific surgical specimen staining correlates with receptor expression level.

    abstract::Intraoperative margin assessment is imperative to cancer cure but is a continued challenge to successful surgery. Breast conserving surgery is a relevant example, where a cosmetically improved outcome is gained over mastectomy, but re-excision is required in >25  %   of cases due to positive or closely involved margin...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.2.026002

    authors: Schaefer JM,Barth CW,Davis SC,Gibbs SL

    更新日期:2019-02-01 00:00:00

  • Precision and Reproducibility of Measurements of Human Corneal Thickness with Rapid Optical Low-Coherence Reflectometry (OLCR).

    abstract::This study investigates the precision and intraindividual variability of a clinical optical pachometer based on low-coherence reflectometry, which was used to measure the central thickness of a human cornea in vivo. The instrument, attached to a slit lamp, is a single mode fiber optic based Michelson interferometer wi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429901

    authors: Bo Hnke M,Masters BR,Wa Lti R,Ballif JJ,Chavanne P,Gianotti R,Salathe RP

    更新日期:1999-01-01 00:00:00

  • Raman microscopy in the diagnosis and prognosis of surgically resected nonsmall cell lung cancer.

    abstract::The main curative therapy for patients with nonsmall cell lung cancer is surgery. Despite this, the survival rate is only 50%, therefore it is important to more efficiently diagnose and predict prognosis for lung cancer patients. Raman spectroscopy is useful in the diagnosis of malignant and premalignant lesions. The ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3323088

    authors: Magee ND,Beattie JR,Carland C,Davis R,McManus K,Bradbury I,Fennell DA,Hamilton PW,Ennis M,McGarvey JJ,Elborn JS

    更新日期:2010-03-01 00:00:00

  • Handheld projective imaging device for near-infrared fluorescence imaging and intraoperative guidance of sentinel lymph node resection.

    abstract::We propose a handheld projective imaging device for orthotopic projection of near-infrared fluorescence images onto target biological tissue at visible wavelengths without any additional visual aid. The device integrates a laser diode light source module, a camera module, a projector, an ultrasonic distance sensor, a ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.8.080503

    authors: Li C,Liu P,Shao P,Pei J,Li Y,Pawlik TM,Martin EW,Xu RX

    更新日期:2019-08-01 00:00:00

  • Swept-source optical coherence tomography powered by a 1.3-μm vertical cavity surface emitting laser enables 2.3-mm-deep brain imaging in mice in vivo.

    abstract::We report noninvasive, in vivo optical imaging deep within a mouse brain by swept-source optical coherence tomography (SS-OCT), enabled by a 1.3-μm vertical cavity surface emitting laser (VCSEL). VCSEL SS-OCT offers a constant signal sensitivity of 105 dB throughout an entire depth of 4.25 mm in air, ensuring an exten...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.10.106004

    authors: Choi WJ,Wang RK

    更新日期:2015-10-01 00:00:00

  • Confocal multispot microscope for fast and deep imaging in semicleared tissues.

    abstract::Although perfectly transparent specimens are imaged faster with light-sheet microscopy, less transparent samples are often imaged with two-photon microscopy leveraging its robustness to scattering; however, at the price of increased acquisition times. Clearing methods that are capable of rendering strongly scattering ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.2.020503

    authors: Adam MP,Müllenbroich MC,Di Giovanna AP,Alfieri D,Silvestri L,Sacconi L,Pavone FS

    更新日期:2018-02-01 00:00:00

  • Combined high-speed holographic shape and full-field displacement measurements of tympanic membrane.

    abstract::The conical shape of the tympanic membrane (TM or eardrum) plays an important role in its function, such that variations in shape alter the acoustically induced motions of the TM. We present a method that precisely determines both shape and acoustically induced transient response of the entire TM using the same optics...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.3.031008

    authors: Razavi P,Tang H,Rosowski JJ,Furlong C,Cheng JT

    更新日期:2018-09-01 00:00:00

  • Sensing dynamic cytoplasm refractive index changes of adherent cells with quantitative phase microscopy using incorporated microspheres as optical probes.

    abstract::The intracellular refractive index is an important parameter that describes the optical density of the cytoplasm and the concentration of the intracellular solutes. The refractive index of adherently grown cells is difficult to access. We present a method in which silica microspheres in living cells are used to determ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.9.097001

    authors: Przibilla S,Dartmann S,Vollmer A,Ketelhut S,Greve B,von Bally G,Kemper B

    更新日期:2012-09-01 00:00:00

  • Noninvasive measurement of glucose concentration on human fingertip by optical coherence tomography.

    abstract::A method is proposed for determining the glucose concentration on the human fingertip by extracting two optical parameters, namely the optical rotation angle and the depolarization index, using a Mueller optical coherence tomography technique and a genetic algorithm. The feasibility of the proposed method is demonstra...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.4.047001

    authors: Chen TL,Lo YL,Liao CC,Phan QH

    更新日期:2018-04-01 00:00:00

  • Laser-ultraviolet-A-induced ultraweak photon emission in mammalian cells.

    abstract::Photobiological research in the last 30 yr has shown the existence of ultraweak photon emission in biological tissue, which can be detected with sophisticated photomultiplier systems. Although the emission of this ultraweak radiation, often termed biophotons, is extremely low in mammalian cells, it can be efficiently ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1899185

    authors: Niggli HJ,Tudisco S,Privitera G,Applegate LA,Scordino A,Musumeci F

    更新日期:2005-03-01 00:00:00

  • Image analysis methods for diffuse optical tomography.

    abstract::Three major analytical tools in imaging science are summarized and demonstrated relative to optical imaging in vivo. Standard resolution testing is optimal when infinite contrast is used and hardware evaluation is the goal. However, deep tissue imaging of absorption or fluorescent contrast agents in vivo often present...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.2209908

    authors: Pogue BW,Davis SC,Song X,Brooksby BA,Dehghani H,Paulsen KD

    更新日期:2006-05-01 00:00:00

  • Resolution in the ApoTome and the confocal laser scanning microscope: comparison.

    abstract::The essential feature of the confocal laser scanning microscope (cLSM) is the generation of optical sections by the removal of out-of-focus light. About ten years ago, structured illumination microscopy (SIM) was introduced as an alternative method for obtaining optical sections from biological specimens. Here we comp...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3083439

    authors: Weigel A,Schild D,Zeug A

    更新日期:2009-01-01 00:00:00

  • Robust single-molecule approach for counting autofluorescent proteins.

    abstract::Using single-molecule microscopy, we present a method to quantify the number of single autofluorescent proteins when they cannot be optically resolved. This method relies on the measurement of the total intensity emitted by each aggregate until it photobleaches. This strategy overcomes the inherent problem of blinking...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2940600

    authors: Cognet L,Tardin C,Négrier ML,Breillat C,Coussen F,Choquet D,Lounis B

    更新日期:2008-05-01 00:00:00

  • Photon migration through fetal head in utero using continuous wave, near-infrared spectroscopy: development and evaluation of experimental and numerical models.

    abstract::In this work experimental tissue phantoms and numerical models were developed to estimate photon migration through the fetal head in utero. The tissue phantoms incorporate a fetal head within an amniotic fluid sac surrounded by a maternal tissue layer. A continuous wave, dual-wavelength (lambda = 760 and 850 nm) spect...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429983

    authors: Vishnoi G,Hielscher AH,Ramanujam N,Chance B

    更新日期:2000-04-01 00:00:00

  • Optical fiber Bragg grating-instrumented silicone liner for interface pressure measurement within prosthetic sockets of lower-limb amputees.

    abstract::This paper presents a fiber Bragg grating (FBG)-instrumented prosthetic silicone liner that provides cushioning for the residual limb and can successfully measure interface pressures inside prosthetic sockets of lower-limb amputees in a simple and practical means of sensing. The liner is made of two silicone layers be...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.8.087001

    authors: Al-Fakih E,Arifin N,Pirouzi G,Mahamd Adikan FR,Shasmin HN,Abu Osman NA

    更新日期:2017-08-01 00:00:00

  • Navigation of a robot-integrated fluorescence laparoscope in preoperative SPECT/CT and intraoperative freehand SPECT imaging data: a phantom study.

    abstract::Robot-assisted laparoscopic surgery is becoming an established technique for prostatectomy and is increasingly being explored for other types of cancer. Linking intraoperative imaging techniques, such as fluorescence guidance, with the three-dimensional insights provided by preoperative imaging remains a challenge. Na...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.8.086008

    authors: van Oosterom MN,Engelen MA,van den Berg NS,KleinJan GH,van der Poel HG,Wendler T,van de Velde CJ,Navab N,van Leeuwen FW

    更新日期:2016-08-01 00:00:00

  • Optoacoustic diagnostic modality: from idea to clinical studies with highly compact laser diode-based systems.

    abstract::Optoacoustic (photoacoustic) diagnostic modality is a technique that combines high optical contrast and ultrasound spatial resolution. We proposed using the optoacoustic technique for a number of applications, including cancer detection, monitoring of thermotherapy (hyperthermia, coagulation, and freezing), monitoring...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.9.091512

    authors: Esenaliev RO

    更新日期:2017-09-01 00:00:00

  • Identification of abnormal motor cortex activation patterns in children with cerebral palsy by functional near-infrared spectroscopy.

    abstract::We demonstrate the utility of functional near-infrared spectroscopy (fNIRS) as a tool for physicians to study cortical plasticity in children with cerebral palsy (CP). Motor cortex activation patterns were studied in five healthy children and five children with CP (8.4+/-2.3 years old in both groups) performing a fing...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3432746

    authors: Khan B,Tian F,Behbehani K,Romero MI,Delgado MR,Clegg NJ,Smith L,Reid D,Liu H,Alexandrakis G

    更新日期:2010-05-01 00:00:00

  • Intravascular near-infrared fluorescence catheter with ultrasound guidance and blood attenuation correction.

    abstract::Intravascular near-infrared fluorescence (NIRF) imaging offers a new approach for characterizing atherosclerotic plaque, but random catheter positioning within the vessel lumen results in variable light attenuation and can yield inaccurate measurements. We hypothesized that NIRF measurements could be corrected for var...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.5.056009

    authors: Dixon AJ,Hossack JA

    更新日期:2013-05-01 00:00:00

  • Preclinical evidence of mitochondrial nicotinamide adenine dinucleotide as an effective alarm parameter under hypoxia.

    abstract::Early detection of tissue hypoxia in the intensive care unit is essential for effective treatment. Reduced nicotinamide adenine dinucleotide (NADH) has been suggested to be the most sensitive indicator of tissue oxygenation at the mitochondrial level. However, no experimental evidence comparing the kinetics of changes...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.1.017005

    authors: Shi H,Sun N,Mayevsky A,Zhang Z,Luo Q

    更新日期:2014-01-01 00:00:00

  • Monte-Carlo-based model for the extraction of intrinsic fluorescence from turbid media.

    abstract::A Monte-Carlo-based model of fluorescence is developed that is capable of extracting the intrinsic fluorescence properties of tissue, which are independent of the absorption and scattering properties of tissue. This model is flexible in its applicability to different illumination-collection geometries and is also vali...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2907161

    authors: Palmer GM,Ramanujam N

    更新日期:2008-03-01 00:00:00

  • Method measuring oxygen tension and transport within subcutaneous devices.

    abstract::Cellular therapies hold promise to replace the implantation of whole organs in the treatment of disease. For most cell types, in vivo viability depends on oxygen delivery to avoid the toxic effects of hypoxia. A promising approach is the in situ vascularization of implantable devices which can mediate hypoxia and impr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.8.087006

    authors: Weidling J,Sameni S,Lakey JR,Botvinick E

    更新日期:2014-08-01 00:00:00

  • In vivo photoacoustic imaging of major blood vessels in the pancreas and liver during surgery.

    abstract::Abdominal surgeries carry considerable risk of gastrointestinal and intra-abdominal hemorrhage, which could possibly cause patient death. Photoacoustic imaging is one solution to overcome this challenge by providing visualization of major blood vessels during surgery. We investigate the feasibility of in vivo blood ve...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.12.121905

    authors: Kempski KM,Wiacek A,Graham M,González E,Goodson B,Allman D,Palmer J,Hou H,Beck S,He J,Bell MAL

    更新日期:2019-08-01 00:00:00

  • Delineation of an oral cancer lesion with swept-source optical coherence tomography.

    abstract::We demonstrate the ex vivo imaging of an oral cancerous sample with a swept-source optical coherence tomography (SS-OCT) system. With the axial resolution of 8 microm in free space and system sensitivity of 108 dB, we can well distinguish the normal and abnormal tissue portions in a sample. In particular, we analyze t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2960632

    authors: Tsai MT,Lee HC,Lu CW,Wang YM,Lee CK,Yang CC,Chiang CP

    更新日期:2008-07-01 00:00:00

  • Contact, high-resolution spatial diffuse reflectance imaging system for skin condition diagnosis.

    abstract::Spatially resolved diffuse reflectance spectroscopy (srDRS) is a well-established technique for noninvasive, in vivo characterization of tissue optical properties toward diagnostic applications. srDRS has a potential for depth-resolved analysis of tissue, which is desired in various clinical situations. However, curre...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.11.115003

    authors: Petitdidier N,Koenig A,Gerbelot R,Grateau H,Gioux S,Jallon P

    更新日期:2018-11-01 00:00:00

  • Photoacoustic properties of anterior ocular tissues.

    abstract::Clinical imaging techniques for the anterior segment of the eye provide excellent anatomical information, but molecular imaging techniques are lacking. Molecular photoacoustic imaging is one option to address this need, but implementation requires use of contrast agents to distinguish molecular targets from background...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.5.056004

    authors: Kubelick KP,Snider EJ,Ethier CR,Emelianov S

    更新日期:2019-05-01 00:00:00