Swept-source optical coherence tomography powered by a 1.3-μm vertical cavity surface emitting laser enables 2.3-mm-deep brain imaging in mice in vivo.

Abstract:

:We report noninvasive, in vivo optical imaging deep within a mouse brain by swept-source optical coherence tomography (SS-OCT), enabled by a 1.3-μm vertical cavity surface emitting laser (VCSEL). VCSEL SS-OCT offers a constant signal sensitivity of 105 dB throughout an entire depth of 4.25 mm in air, ensuring an extended usable imaging depth range of more than 2 mm in turbid biological tissue. Using this approach, we show deep brain imaging in mice with an open-skull cranial window preparation, revealing intact mouse brain anatomy from the superficial cerebral cortex to the deep hippocampus. VCSEL SS-OCT would be applicable to small animal studies for the investigation of deep tissue compartments in living brains where diseases such as dementia and tumor can take their toll.

journal_name

J Biomed Opt

authors

Choi WJ,Wang RK

doi

10.1117/1.JBO.20.10.106004

subject

Has Abstract

pub_date

2015-10-01 00:00:00

pages

106004

issue

10

eissn

1083-3668

issn

1560-2281

pii

2458790

journal_volume

20

pub_type

杂志文章
  • Measuring the dynamics of cyclic adenosine monophosphate level in living cells induced by low-level laser irradiation using bioluminescence resonance energy transfer.

    abstract::Several studies demonstrated that the cyclic adenosine monophosphate (cAMP), an important second messenger, is involved in the mechanism of low-level laser irradiation (LLLI) treatment. However, most of these studies obtained the cAMP level in cell culture extracts or supernatant. In this study, the cAMP level in livi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.5.051029

    authors: Huang Y,Zheng L,Yang H,Chen J,Wang Y,Li H,Xie S,Zeng H

    更新日期:2015-05-01 00:00:00

  • Retinal blood flow measurement by circumpapillary Fourier domain Doppler optical coherence tomography.

    abstract::We present in vivo human total retinal blood flow measurements using Doppler Fourier domain optical coherence tomography (OCT). The scan pattern consisted of two concentric circles around the optic nerve head, transecting all retinal branch arteries and veins. The relative positions of each blood vessel in the two OCT...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2998480

    authors: Wang Y,Bower BA,Izatt JA,Tan O,Huang D

    更新日期:2008-11-01 00:00:00

  • Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry.

    abstract::Optical spectroscopy, imaging, and therapy tissue phantoms must have the scattering and absorption properties that are characteristic of human tissues, and over the past few decades, many useful models have been created. In this work, an overview of their composition and properties is outlined, by separating matrix, s...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.2335429

    authors: Pogue BW,Patterson MS

    更新日期:2006-07-01 00:00:00

  • Ex vivo optical metabolic measurements from cultured tissue reflect in vivo tissue status.

    abstract::Optical measurements of metabolism are ideally acquired in vivo; however, intravital measurements are often impractical. Accurate ex vivo assessments would greatly broaden the applicability of optical measurements of metabolism. We investigate the use of live tissue culture experiments to serve as a surrogate for in v...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.11.116015

    authors: Walsh AJ,Poole KM,Duvall CL,Skala MC

    更新日期:2012-11-01 00:00:00

  • In vitro model for endogenous optical signatures of collagen.

    abstract::Type I collagen is a major component of the extracellular matrix as well as many tissue engineered models. To understand changes in collagen related models over time, it is important to evaluate collagen dynamics with noninvasive techniques. Fluorescence spectroscopy provides a method to noninvasively measure endogeno...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2360516

    authors: Kirkpatrick ND,Hoying JB,Botting SK,Weiss JA,Utzinger U

    更新日期:2006-09-01 00:00:00

  • Time-dependent blood flow and oxygenation in human skeletal muscles measured with noninvasive near-infrared diffuse optical spectroscopies.

    abstract::We have employed near-infrared optical methods to measure noninvasively the dynamics of muscle blood flow and oxygen saturation (StO2) during cuff occlusion and plantar flexion exercise. Relative muscle oxygen consumption (rVO2) was also computed from these data. Diffuse correlation spectroscopy provides information a...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1884603

    authors: Yu G,Durduran T,Lech G,Zhou C,Chance B,Mohler ER 3rd,Yodh AG

    更新日期:2005-03-01 00:00:00

  • Quantitative measurement of reactive oxygen species in vivo by utilizing a novel method: chemiluminescence with an internal fluorescence as reference.

    abstract::Reactive oxygen species (ROS) produced by photodynamic therapy (PDT) is recorded in vivo using a chemiluminescence (CL)-based gated optical system. A novel approach is developed to utilize the fluorescence (FL) of the CL probe as an internal fluorescence to calibrate the observed CL on pharmacokinetics of the probe in...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3368688

    authors: Wei Y,Xing D,Luo S,Yang L,Chen Q

    更新日期:2010-03-01 00:00:00

  • Single-cell analysis of dihydroartemisinin-induced apoptosis through reactive oxygen species-mediated caspase-8 activation and mitochondrial pathway in ASTC-a-1 cells using fluorescence imaging techniques.

    abstract::Dihydroartemisinin (DHA), a front-line antimalarial herbal compound, has been shown to possess promising anticancer activity with low toxicity. We have previously reported that DHA induced caspase-3-dependent apoptosis in human lung adenocarcinoma cells. However, the cellular target and molecular mechanism of DHA-indu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3481141

    authors: Lu YY,Chen TS,Wang XP,Li L

    更新日期:2010-07-01 00:00:00

  • Continuous-wave circular polarization terahertz imaging.

    abstract::Biomedical applications of terahertz (THz) radiation are appealing because THz radiation is nonionizing and has the demonstrated ability to detect intrinsic contrasts between cancerous and normal tissue. A linear polarization-sensitive detection technique for tumor margin delineation has already been demonstrated; how...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.7.070502

    authors: Martin JP,Joseph CS,Giles RH

    更新日期:2016-07-01 00:00:00

  • Design and validation of an angle-resolved low-coherence interferometry fiber probe for in vivo clinical measurements of depth-resolved nuclear morphology.

    abstract::We present a novel Fourier-domain angle-resolved low-coherence interferometry (a /LCI) fiber probe designed for in vivo clinical application in gastrointestinal endoscopy. The a/LCI technique measures the depth-resolved angular scattering distribution to determine the size distribution and optical density of cell nucl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3520130

    authors: Zhu Y,Terry NG,Woosley JT,Shaheen NJ,Wax A

    更新日期:2011-01-01 00:00:00

  • Correlation of in vivo photosensitizer fluorescence and photodynamic-therapy-induced depth of necrosis in a murine tumor model.

    abstract::We compared light-induced fluorescence (LIF) to nominal injected drug dose for predicting the depth of necrosis response to photodynamic therapy (PDT) in a murine tumor model. Mice were implanted with radiation-induced fibrosarcoma (RIF) and were injected with 0, 5, or 10 mg/kg Photofrin. 630-nm light (30 J/cm(2), 75 ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1560011

    authors: Cheung R,Solonenko M,Busch TM,Del Piero F,Putt ME,Hahn SM,Yodh AG

    更新日期:2003-04-01 00:00:00

  • Comparison of laser and diode sources for acceleration of in vitro wound healing by low-level light therapy.

    abstract::Low-level light therapy has been shown to improve in vitro wound healing. However, well-defined parameters of different light sources for this therapy are lacking. The goal of this study was (1) to determine if the wavelengths tested are effective for in vitro wound healing and (2) to compare a laser and a light-emitt...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.3.038001

    authors: Spitler R,Berns MW

    更新日期:2014-03-01 00:00:00

  • Structured light scatteroscopy.

    abstract::A new imaging approach, structured light scatteroscopy (SLS), is demonstrated, which offers rapid wide-field imaging of microscopic morphological variations in bulk tissue surfaces. Elastic scattering of light offers exquisite sensitivity to ultrastructural changes at multiple size scales ranging from nanometers to mi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.7.070504

    authors: Krishnaswamy V,Elliott JT,McClatchy DM 3rd,Barth RJ Jr,Wells WA,Pogue BW,Paulsen KD

    更新日期:2014-01-01 00:00:00

  • Three-dimensional optical coherence tomography at 1050 nm versus 800 nm in retinal pathologies: enhanced performance and choroidal penetration in cataract patients.

    abstract::Frequency domain optical coherence tomography (FD-OCT), based on an all-reflective high-speed InGaAs spectrometer, operating in the 1050 nm wavelength region for retinal diagnostics, enables high-speed, volumetric imaging of retinal pathologies with greater penetration into choroidal tissue is compared to conventional...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2773728

    authors: Povazay B,Hermann B,Unterhuber A,Hofer B,Sattmann H,Zeiler F,Morgan JE,Falkner-Radler C,Glittenberg C,Blinder S,Drexler W

    更新日期:2007-07-01 00:00:00

  • Nonlinear multispectral imaging for tumor delineation.

    abstract:SIGNIFICANCE:In breast-preserving tumor surgery, the inspection of the excised tissue boundaries for tumor residue is too slow to provide feedback during the surgery. The discovery of positive margins requires a new surgery which is difficult and associated with low success. If the re-excision could be done immediately...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.9.096001

    authors: Beletkaia E,Dashtbozorg B,Jansen RG,Ruers TJM,Offerhaus HL

    更新日期:2020-09-01 00:00:00

  • Holographic laser Doppler imaging of pulsatile blood flow.

    abstract::We report on wide-field imaging of pulsatile motion induced by blood flow using heterodyne holographic interferometry on the thumb of a healthy volunteer, in real time. Optical Doppler images were measured with green laser light by a frequency-shifted Mach-Zehnder interferometer in off-axis configuration. The recorded...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.6.066006

    authors: Bencteux J,Pagnoux P,Kostas T,Bayat S,Atlan M

    更新日期:2015-06-01 00:00:00

  • New pediatric vision screener employing polarization-modulated, retinal-birefringence-scanning-based strabismus detection and bull's eye focus detection with an improved target system: opto-mechanical design and operation.

    abstract::Amblyopia ("lazy eye") is a major public health problem, caused by misalignment of the eyes (strabismus) or defocus. If detected early in childhood, there is an excellent response to therapy, yet most children are detected too late to be treated effectively. Commercially available vision screening devices that test fo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.6.067004

    authors: Irsch K,Gramatikov BI,Wu YK,Guyton DL

    更新日期:2014-06-01 00:00:00

  • Diagnosis of oral submucous fibrosis with optical coherence tomography.

    abstract::The epithelium (EP) thickness and the standard deviation (SD) of A-mode scan intensity in the laminar propria (LP) layer are used as effective indicators for the diagnosis of oral submucous fibrosis (OSF) based on the noninvasive clinical scanning of a swept-source optical coherence tomography (OCT) system of approxim...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3233653

    authors: Lee CK,Tsai MT,Lee HC,Chen HM,Chiang CP,Wang YM,Yang CC

    更新日期:2009-09-01 00:00:00

  • Overview of diffuse optical tomography and its clinical applications.

    abstract::Near-infrared diffuse optical tomography (DOT), one of the most sophisticated optical imaging techniques for observations through biological tissue, allows 3-D quantitative imaging of optical properties, which include functional and anatomical information. With DOT, it is expected to be possible to overcome the limita...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.21.9.091312

    authors: Hoshi Y,Yamada Y

    更新日期:2016-09-01 00:00:00

  • Miniature endoscopic optical coherence tomography probe employing a two-axis microelectromechanical scanning mirror with through-silicon vias.

    abstract::We present the design and experimental results of a new MEMS-based endoscopic optical coherence tomography (OCT) probe. The uniqueness of this miniature OCT imaging probe is a two-axis MEMS mirror with through-silicon vias (TSVs) for interconnecting. The TSV interconnection enables ultracompact probe design, successfu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3533323

    authors: Liu L,Wu L,Sun J,Lin E,Xie H

    更新日期:2011-02-01 00:00:00

  • Computer model to investigate the effect of eye movements on retinal heating during long-duration fixation on a laser source.

    abstract::A computer simulation called RHME (Retinal Heating in Moving Eye) is developed to simulate the heating pattern that occurs in the retina during a long-duration exposure to a continuous wave laser beam. The simulation takes into account eye movements that occur during a deliberate fixation. Due to the rapid (millisecon...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1783355

    authors: Lund BJ

    更新日期:2004-09-01 00:00:00

  • Raman spectroscopy of in vivo cutaneous melanin.

    abstract::We successfully acquire the in vivo Raman spectrum of melanin from human skin using a rapid near-infrared (NIR) Raman spectrometer. The Raman signals of in vivo cutaneous melanin are similar to those observed from natural and synthetic eumelanins. The melanin Raman spectrum is dominated by two intense and broad peaks ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1805553

    authors: Huang Z,Lui H,Chen XK,Alajlan A,McLean DI,Zeng H

    更新日期:2004-11-01 00:00:00

  • Video-rate optical flow corrected intraoperative functional fluorescence imaging.

    abstract::Intraoperative fluorescence molecular imaging based on targeted fluorescence agents is an emerging approach to improve surgical and endoscopic imaging and guidance. Short exposure times per frame and implementation at video rates are necessary to provide continuous feedback to the physician and avoid motion artifacts....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.4.046012

    authors: Koch M,Glatz J,Ermolayev V,de Vries EG,van Dam GM,Englmeier KH,Ntziachristos V

    更新日期:2014-04-01 00:00:00

  • Effects of breast density and compression on normal breast tissue hemodynamics through breast tomosynthesis guided near-infrared spectral tomography.

    abstract::Optically derived tissue properties across a range of breast densities and the effects of breast compression on estimates of hemoglobin, oxygen metabolism, and water and lipid concentrations were obtained from a coregistered imaging system that integrates near-infrared spectral tomography (NIRST) with digital breast t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.9.091316

    authors: Michaelsen KE,Krishnaswamy V,Shi L,Vedantham S,Karellas A,Pogue BW,Paulsen KD,Poplack SP

    更新日期:2016-09-01 00:00:00

  • Control of cardiomyocyte orientation on a microscaffold fabricated by photopolymerization with laser beam interference.

    abstract::We fabricate scaffolds with a fine linear grating (periodicity of 1 to 8 microm and height of 1 microm) on a glass substrate for controlling cardiomyocyte orientation. The fabrication is done by the solidification of a liquid photopolymerizable material using two laser beam interference. As the photopolymerizable mate...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2186042

    authors: Fujita A,Fujita K,Nakamura O,Matsuda T,Kawata S

    更新日期:2006-03-01 00:00:00

  • Photoacoustic imaging of lymphatic pumping.

    abstract::The lymphatic system is responsible for fluid homeostasis and immune cell trafficking and has been implicated in several diseases, including obesity, diabetes, and cancer metastasis. Despite its importance, the lack of suitable in vivo imaging techniques has hampered our understanding of the lymphatic system. This is,...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.10.106003

    authors: Forbrich A,Heinmiller A,Zemp RJ

    更新日期:2017-10-01 00:00:00

  • Real-time in vivo photoacoustic and ultrasound imaging.

    abstract::A real-time photoacoustic imaging system is designed and built. This system is based on a commercially available ultrasound imaging system. It can achieve a frame rate of 8 frames/sec. Vasculature in the hand of a human volunteer is imaged, and the resulting photoacoustic image is combined with the ultrasound image. T...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3005421

    authors: Kolkman RG,Brands PJ,Steenbergen W,van Leeuwen TG

    更新日期:2008-09-01 00:00:00

  • Eigenvector-based spatial filtering for reduction of physiological interference in diffuse optical imaging.

    abstract::Diffuse optical imaging is an effective technique for noninvasive functional brain imaging. However, the measurements respond to systemic hemodynamic fluctuations caused by the cardiac cycle, respiration, and blood pressure, which may obscure or overwhelm the desired stimulus-evoked response. Previous work on this pro...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1852552

    authors: Zhang Y,Brooks DH,Franceschini MA,Boas DA

    更新日期:2005-01-01 00:00:00

  • Multimodal optical microscope for detecting viability of mouse embryos in vitro.

    abstract::We present a multimodal optical microscope that incorporates six imaging modalities on one common platform. The imaging modalities include three staring modes, optical quadrature microscopy (OQM), differential interference contrast (DIC) microscopy, and epi-fluorescence microscopy, and three scanning modes, confocal r...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2753744

    authors: Warger WC 2nd,Laevsky GS,Townsend DJ,Rajadhyaksha M,DiMarzio CA

    更新日期:2007-07-01 00:00:00

  • In vivo label-free quantification of liver microcirculation using dual-modality microscopy.

    abstract::Microcirculation lesion is a common symptom of chronic liver diseases in the form of vasculature deformation and circulation alteration. In acute to chronic liver diseases such as biliary atresia, microcirculation lesion can have an early onset. Detection of microcirculation lesion is meaningful for studying the progr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.116006

    authors: Yan J,Kang Y,Xu S,Ong LL,Zhuo S,Bunte RM,Chen N,Asada HH,So PT,Wanless IR,Yu H

    更新日期:2014-01-01 00:00:00