Raman mapping of oral buccal mucosa: a spectral histopathology approach.

Abstract:

:Oral cancer is one of the most common cancers worldwide. One-fifth of the world's oral cancer subjects are from India and other South Asian countries. The present Raman mapping study was carried out to understand biochemical variations in normal and malignant oral buccal mucosa. Data were acquired using WITec alpha 300R instrument from 10 normal and 10 tumors unstained tissue sections. Raman maps of normal sections could resolve the layers of epithelium, i.e. basal, intermediate, and superficial. Inflammatory, tumor, and stromal regions are distinctly depicted on Raman maps of tumor sections. Mean and difference spectra of basal and inflammatory cells suggest abundance of DNA and carotenoids features. Strong cytochrome bands are observed in intermediate layers of normal and stromal regions of tumor. Epithelium and stromal regions of normal cells are classified by principal component analysis. Classification among cellular components of normal and tumor sections is also observed. Thus, the findings of the study further support the applicability of Raman mapping for providing molecular level insights in normal and malignant conditions.

journal_name

J Biomed Opt

authors

Behl I,Kukreja L,Deshmukh A,Singh SP,Mamgain H,Hole AR,Krishna CM

doi

10.1117/1.JBO.19.12.126005

subject

Has Abstract

pub_date

2014-12-01 00:00:00

pages

126005

issue

12

eissn

1083-3668

issn

1560-2281

pii

2022044

journal_volume

19

pub_type

杂志文章
  • Measurement of the refractive index of whole blood and its components for a continuous spectral region.

    abstract::The refractive index of blood is a key biophysical parameter, which can reflect the physiological state. We measured the refractive index of whole blood and other components, such as serum, plasma, and hemoglobin, based on internal reflection by using a homemade apparatus in the spectral range of 400 to 750 nm. In add...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.3.035003

    authors: Liu S,Deng Z,Li J,Wang J,Huang N,Cui R,Zhang Q,Mei J,Zhou W,Zhang C,Ye Q,Tian J

    更新日期:2019-03-01 00:00:00

  • Infrared spectroscopic analysis of human and bovine articular cartilage proteoglycans using carbohydrate peak or its second derivative.

    abstract::Fourier transform infrared (FTIR) microspectroscopy has been used to estimate the spatial proteoglycan (PG) and collagen contents in articular cartilage (AC). However, it is not clear whether the results of FTIR analyses are consistent between different species. Our aim was to clarify how three different FTIR PG param...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.9.097006

    authors: Rieppo L,Närhi T,Helminen HJ,Jurvelin JS,Saarakkala S,Rieppo J

    更新日期:2013-09-01 00:00:00

  • Monitoring the reduced scattering coefficient of bone tissues on the trajectory of pedicle screw placement using near-infrared spectroscopy.

    abstract::Pedicle screw (PS) fixation has been widely used for spine diseases. Scientists and clinicians employ several approaches to navigate PS during operation. We have demonstrated the feasibility of monitoring the reduced scattering coefficient (μ's) on the trajectory of PS using near-infrared spectroscopy (NIRS). To perfo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.117002

    authors: Liu Y,Wang Y,Qian Z,Zhao J,Cao X,Li W

    更新日期:2014-01-01 00:00:00

  • Measurement of drug and macromolecule diffusion across atherosclerotic rabbit aorta ex vivo by attenuated total reflection-Fourier transform infrared imaging.

    abstract::Diffusion of two model drugs-benzyl nicotinate and ibuprofen-and the plasma macromolecule albumin across atherosclerotic rabbit aorta was studied ex vivo by attenuated total reflection-Fourier transform infrared (ATR-FTIR) imaging. Solutions of these molecules were applied to the endothelial surface of histological se...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3174395

    authors: Palombo F,Danoux CB,Weinberg PD,Kazarian SG

    更新日期:2009-07-01 00:00:00

  • Optical coherence tomography for the diagnosis of malignant skin tumors: a meta-analysis.

    abstract::Optical coherence tomography (OCT) is an emergent imaging tool used for noninvasive diagnosis of skin diseases. The present meta-analysis was carried out to assess the accuracy of OCT for the diagnosis of skin cancer. We conducted a systematic literature search though EMBASE, Medline, PubMed, the Cochrane Library, and...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,meta分析

    doi:10.1117/1.JBO.23.2.020902

    authors: Xiong YQ,Mo Y,Wen YQ,Cheng MJ,Huo ST,Chen XJ,Chen Q

    更新日期:2018-02-01 00:00:00

  • On the noninvasive optical monitoring and differentiation of methemoglobinemia and sulfhemoglobinemia.

    abstract::There are several pathologies whose study and diagnosis is impaired by a relatively small number of documented cases. A practical approach to overcome this obstacle and advance the research in this area consists in employing computer simulations to perform controlled in silico experiments. The results of these experim...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.9.097005

    authors: Baranoski GV,Chen TF,Kimmel BW,Miranda E,Yim D

    更新日期:2012-09-01 00:00:00

  • Ultrafast wavelength multiplexed broad bandwidth digital diffuse optical spectroscopy for in vivo extraction of tissue optical properties.

    abstract::Frequency-domain diffuse optical spectroscopy (FD-DOS) utilizes intensity-modulated light to characterize optical scattering and absorption in thick tissue. Previous FD-DOS systems have been limited by large device footprints, complex electronics, high costs, and limited acquisition speeds, all of which complicate acc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.3.036009

    authors: Torjesen A,Istfan R,Roblyer D

    更新日期:2017-03-01 00:00:00

  • Interplay of tumor vascular oxygenation and tumor pO2 observed using near-infrared spectroscopy, an oxygen needle electrode, and 19F MR pO2 mapping.

    abstract::This study investigates the correlation of tumor blood oxygenation and tumor pO(2) with respect to carbogen inhalation. After having refined and validated the algorithms for calculating hemoglobin concentrations, we used near-infrared spectroscopy (NIRS) to measure changes of oxygenated hemoglobin concentration (delta...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1527049

    authors: Kim JG,Zhao D,Song Y,Constantinescu A,Mason RP,Liu H

    更新日期:2003-01-01 00:00:00

  • Analysis of sampling volume and tissue heterogeneity on the in vivo detection of fluorescence.

    abstract::The effect of sampling region size and tissue heterogeneity is examined using fluorescence histogram assessment in a rat prostate tumor model with benzoporphyrin derivative fluorophore. Spatial heterogeneity in the fluorescence signal occurs on both macroscopic and microscopic scales. The periphery of the tumor is mor...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2002978

    authors: Pogue BW,Chen B,Zhou X,Hoopes PJ

    更新日期:2005-07-01 00:00:00

  • Design and validation of an angle-resolved low-coherence interferometry fiber probe for in vivo clinical measurements of depth-resolved nuclear morphology.

    abstract::We present a novel Fourier-domain angle-resolved low-coherence interferometry (a /LCI) fiber probe designed for in vivo clinical application in gastrointestinal endoscopy. The a/LCI technique measures the depth-resolved angular scattering distribution to determine the size distribution and optical density of cell nucl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3520130

    authors: Zhu Y,Terry NG,Woosley JT,Shaheen NJ,Wax A

    更新日期:2011-01-01 00:00:00

  • Preliminary evaluation of optical glucose sensing in red cell concentrations using near-infrared diffuse-reflectance spectroscopy.

    abstract::Bacterial contamination of blood products is one of the most frequent infectious complications of transfusion. Since glucose levels in blood supplies decrease as bacteria proliferate, it should be possible to detect the presence of bacterial contamination by measuring the glucose concentrations in the blood components...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.1.017004

    authors: Suzuki Y,Maruo K,Zhang AW,Shimogaki K,Ogawa H,Hirayama F

    更新日期:2012-01-01 00:00:00

  • Photochemical effects and hypericin photosensitized processes in collagen.

    abstract::Emission and excitation spectra of collagen were recorded in the ultraviolet and visible regions. The existence of several types of chromophores absorbing and emitting throughout these spectral regions was observed. It was shown that laser irradiation at 355 and 532 nm caused collagen fluorescence photobleaching by 30...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1331559

    authors: Yova D,Hovhannisyan V,Theodossiou T

    更新日期:2001-01-01 00:00:00

  • Intravascular near-infrared fluorescence catheter with ultrasound guidance and blood attenuation correction.

    abstract::Intravascular near-infrared fluorescence (NIRF) imaging offers a new approach for characterizing atherosclerotic plaque, but random catheter positioning within the vessel lumen results in variable light attenuation and can yield inaccurate measurements. We hypothesized that NIRF measurements could be corrected for var...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.5.056009

    authors: Dixon AJ,Hossack JA

    更新日期:2013-05-01 00:00:00

  • Variations in the endogenous fluorescence of rabbit corneas after mechanical property alterations.

    abstract::Keratoconus is an eye disease in which the cornea progressively deforms due to loss of cornea mechanical rigidity, and thus causes deterioration of visual acuity. Techniques to characterize the mechanical characteristics of the cornea are important to better monitor changes and response to treatments. To investigate t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.9.095005

    authors: Ortega-Martinez A,Touchette G,Zhu H,Kochevar IE,Franco W

    更新日期:2017-09-01 00:00:00

  • Quantitative tool for rapid disease mapping using optical coherence tomography images of azoxymethane-treated mouse colon.

    abstract::Optical coherence tomography (OCT) can provide new insight into disease progression and therapy by enabling nondestructive, serial imaging of in vivo cancer models. In previous studies, we have shown the utility of endoscopic OCT for identifying adenomas in the azoxymethane-treated mouse model of colorectal cancer and...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3446674

    authors: Winkler AM,Rice PF,Drezek RA,Barton JK

    更新日期:2010-07-01 00:00:00

  • Spectral imaging technique for retinal perfusion detection using confocal scanning laser ophthalmoscopy.

    abstract::To evaluate retinal perfusion in the human eye, a dual-wavelength confocal scanning laser ophthalmoscope (cSLO) was developed that provides spectral imaging of the fundus using a combination of red (670 nm) and near-infrared (810 nm) wavelengths. The image of the ocular fundus was analyzed to find out if quantitative ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.11.116005

    authors: Rasta SH,Manivannan A,Sharp PF

    更新日期:2012-11-01 00:00:00

  • Noninvasive monitoring of hemodynamic stress using quantitative near-infrared frequency-domain photon migration spectroscopy.

    abstract::Hemorrhagic hypovolemia and inotropic agent administration were used to manipulate cardiac output (CO) and oxygen delivery in rabbits to investigate the correlation between noninvasive frequency domain photon migration (FDPM) spectroscopy and invasive hemodynamic monitoring parameters. Frequency-domain photon migratio...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1427046

    authors: Pham TH,Hornung R,Ha HP,Burney T,Serna D,Powell L,Brenner M,Tromberg BJ

    更新日期:2002-01-01 00:00:00

  • Raman biophysical markers in skin cancer diagnosis.

    abstract::Raman spectroscopy (RS) has demonstrated great potential for in vivo cancer screening; however, the biophysical changes that occur for specific diagnoses remain unclear. We recently developed an inverse biophysical skin cancer model to address this issue. Here, we presented the first demonstration of in vivo melanoma ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.5.057002

    authors: Feng X,Moy AJ,Nguyen HTM,Zhang Y,Zhang J,Fox MC,Sebastian KR,Reichenberg JS,Markey MK,Tunnell JW

    更新日期:2018-05-01 00:00:00

  • Methodology for examining polarized light interactions with tissues and tissuelike media in the exact backscattering direction.

    abstract::The properties of polarized light emerging from turbid media in the exact backscattering direction are studied by modulating the incident light polarization state and isolating the synchronous signal with lock-in amplifier detection. The results are reported for polystyrene microsphere suspensions in distilled water, ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.430004

    authors: Studinski RC,Vitkin IA

    更新日期:2000-07-01 00:00:00

  • Adaptive optics for fluorescence wide-field microscopy using spectrally independent guide star and markers.

    abstract::We describe the implementation and use of an adaptive optics loop in the imaging path of a commercial wide field microscope. We show that it is possible to maintain the optical performances of the original microscope when imaging through aberrant biological samples. The sources used for illuminating the adaptive optic...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3603847

    authors: Vermeulen P,Muro E,Pons T,Loriette V,Fragola A

    更新日期:2011-07-01 00:00:00

  • Staining-free malaria diagnostics by multispectral and multimodality light-emitting-diode microscopy.

    abstract::We report an accurate optical differentiation technique between healthy and malaria-infected erythrocytes by quasi-simultaneous measurements of transmittance, reflectance, and scattering properties of unstained blood smears using a multispectral and multimode light-emitting diode microscope. We propose a technique for...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.036002

    authors: Merdasa A,Brydegaard M,Svanberg S,Zoueu JT

    更新日期:2013-03-01 00:00:00

  • Quantitative three-dimensional photoacoustic tomography of the finger joints: an in vivo study.

    abstract::We present for the first time in vivo full three-dimensional (3-D) photoacoustic tomography (PAT) of the distal interphalangeal joint in a human subject. Both absorbed energy density and absorption coefficient images of the joint are quantitatively obtained using our finite-element-based photoacoustic image reconstruc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3257246

    authors: Sun Y,Sobel E,Jiang H

    更新日期:2009-11-01 00:00:00

  • Near-infrared transmittance pulse oximetry with laser diodes.

    abstract::Pulse oximeters are widely used for noninvasive monitoring of oxygen saturation in arterial blood hemoglobin. We present a transmittance pulse oximetry system based on near-infrared (NIR) laser diodes (750 and 850 nm) for monitoring oxygen saturation of arterial blood hemoglobin. The pulse oximetry system is made up o...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1578495

    authors: Lopez Silva SM,Dotor Castilla ML,Silveira Martin JP

    更新日期:2003-07-01 00:00:00

  • Effect of light losses of sample between two integrating spheres on optical properties estimation.

    abstract::A Monte Carlo algorithm is applied to simulate the measurements of a sample with glass slides sandwiched between the double integrating sphere (DIS) setup. The effects caused by various parameters, such as the sample port of integrating sphere, thicknesses, and optical properties of the sample, on light losses and opt...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2815691

    authors: Zhu D,Lu W,Zeng S,Luo Q

    更新日期:2007-11-01 00:00:00

  • Control of cardiomyocyte orientation on a microscaffold fabricated by photopolymerization with laser beam interference.

    abstract::We fabricate scaffolds with a fine linear grating (periodicity of 1 to 8 microm and height of 1 microm) on a glass substrate for controlling cardiomyocyte orientation. The fabrication is done by the solidification of a liquid photopolymerizable material using two laser beam interference. As the photopolymerizable mate...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2186042

    authors: Fujita A,Fujita K,Nakamura O,Matsuda T,Kawata S

    更新日期:2006-03-01 00:00:00

  • Optical fiber Bragg grating-instrumented silicone liner for interface pressure measurement within prosthetic sockets of lower-limb amputees.

    abstract::This paper presents a fiber Bragg grating (FBG)-instrumented prosthetic silicone liner that provides cushioning for the residual limb and can successfully measure interface pressures inside prosthetic sockets of lower-limb amputees in a simple and practical means of sensing. The liner is made of two silicone layers be...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.8.087001

    authors: Al-Fakih E,Arifin N,Pirouzi G,Mahamd Adikan FR,Shasmin HN,Abu Osman NA

    更新日期:2017-08-01 00:00:00

  • Multimodal optical measurement in vitro of surface deformations and wall thickness of the pressurized aortic arch.

    abstract::Computational modeling of arterial mechanics continues to progress, even to the point of allowing the study of complex regions such as the aortic arch. Nevertheless, most prior studies assign homogeneous and isotropic material properties and constant wall thickness even when implementing patient-specific luminal geome...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.4.046005

    authors: Genovese K,Humphrey JD

    更新日期:2015-04-01 00:00:00

  • Transmission versus reflectance spectroscopy for quantitation.

    abstract::The objective of this work was to compare the accuracy of analyte concentration estimation when using transmission versus diffuse reflectance spectroscopy of a scattering medium. Monte Carlo ray tracing of light through the medium was used in conjunction with pure component absorption spectra and Beer-Lambert absorpti...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.1.018001

    authors: Gardner CM

    更新日期:2018-01-01 00:00:00

  • Temperature-controlled in vivo ocular exposure to 1090-nm radiation suggests that near-infrared radiation cataract is thermally induced.

    abstract::The damage mechanism for near-infrared radiation (IRR) induced cataract is unclear. Both a photochemical and a thermal mechanism were suggested. The current paper aims to elucidate a photochemical effect based on investigation of irradiance-exposure time reciprocity. Groups of 20 rats were unilaterally exposed to 96-W...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.1.015003

    authors: Yu Z,Schulmeister K,Talebizadeh N,Kronschläger M,Söderberg P

    更新日期:2015-01-01 00:00:00

  • Vector extrapolation methods for accelerating iterative reconstruction methods in limited-data photoacoustic tomography.

    abstract::As limited data photoacoustic tomographic image reconstruction problem is known to be ill-posed, the iterative reconstruction methods were proven to be effective in terms of providing good quality initial pressure distribution. Often, these iterative methods require a large number of iterations to converge to a soluti...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.7.071204

    authors: Awasthi N,Kalva SK,Pramanik M,Yalavarthy PK

    更新日期:2018-02-01 00:00:00