Comparison of motion correction techniques applied to functional near-infrared spectroscopy data from children (Erratum).

Abstract:

:The erratum concerns amendment of Section 2.5 of the published article.

journal_name

J Biomed Opt

authors

Hu XS,Arredondo MM,Gomba M,Confer N,DaSilva AF,Johnson TD,Shalinsky M,Kovelman I

doi

10.1117/1.JBO.25.5.059801

subject

Has Abstract

pub_date

2020-05-01 00:00:00

pages

1

issue

5

eissn

1083-3668

issn

1560-2281

pii

JBO-20-0429

journal_volume

25

pub_type

杂志文章,已发布勘误
  • Optical coherence tomography in gynecology: a narrative review.

    abstract::Modern gynecologic practice requires noninvasive diagnostics techniques capable of detecting morphological and functional alterations in tissues of female reproductive organs. Optical coherence tomography (OCT) is a promising tool for providing imaging of biotissues with high resolution at depths up to 2 mm. Design of...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.22.12.121709

    authors: Kirillin M,Motovilova T,Shakhova N

    更新日期:2017-12-01 00:00:00

  • No-core fiber-based highly sensitive optical fiber pH sensor.

    abstract::The present work describes the fabrication and characterization of an optical fiber pH sensor using a sol–gel technique. The sensing head configuration is incorporated using a short section of no-core fiber, coated with tetraethyl orthosilicate and spliced at the end of a single mode fiber with a bulge. Different type...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.5.057001

    authors: Bhardwaj V,Pathak AK,Singh VK

    更新日期:2017-05-01 00:00:00

  • Characterization of a multicore fiber image guide for nonlinear endoscopic imaging using two-photon fluorescence and second-harmonic generation.

    abstract::Multiphoton microscopy (MPM) has the capacity to record second-harmonic generation (SHG) and endogenous two-photon excitation fluorescence (2PEF) signals emitted from biological tissues. The development of fiber-based miniaturized endomicroscopes delivering pulses in the femtosecond range will allow the transfer of MP...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.10.106004

    authors: Garofalakis A,Kruglik SG,Mansuryan T,Gillibert A,Thiberville L,Louradour F,Vever-Bizet C,Bourg-Heckly G

    更新日期:2019-10-01 00:00:00

  • Analysis of the efficiency of hair removal by different optical methods: comparison of Trichoscan, reflectance confocal microscopy, and optical coherence tomography.

    abstract::Noninvasive diagnostic tools, such as Trichoscan®, reflectance confocal microscopy (RCM), and optical coherence tomography (OCT), are efficient methods of hair shaft and growth evaluation. The aim of this study was to carry out a comparative assessment of these three medical procedures by measuring the hair shaft and ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,随机对照试验

    doi:10.1117/1.JBO.17.10.101504

    authors: Kuck M,Schanzer S,Ulrich M,Garcia Bartels N,Meinke MC,Fluhr J,Krah M,Blume-Peytavi U,Stockfleth E,Lademann J

    更新日期:2012-10-01 00:00:00

  • Differentiation of cancer cells in two-dimensional and three-dimensional breast cancer models by Raman spectroscopy.

    abstract::We demonstrate the first application of Raman spectroscopy in diagnosing nonmalignant, premalignant, malignant, and metastatic stages of breast cancer in a three-dimensional (3-D) cell culture model that closely mimics an in vivo environment. Comprehensive study comparing classification in two-dimensional (2-D) and 3-...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.11.117008

    authors: Damayanti NP,Fang Y,Parikh MR,Craig AP,Kirshner J,Irudayaraj J

    更新日期:2013-11-01 00:00:00

  • Calibration of diffuse correlation spectroscopy blood flow index with venous-occlusion diffuse optical spectroscopy in skeletal muscle.

    abstract::We investigate and assess the utility of a simple scheme for continuous absolute blood flow monitoring based on diffuse correlation spectroscopy (DCS). The scheme calibrates DCS using venous-occlusion diffuse optical spectroscopy (VO-DOS) measurements of arm muscle tissue at a single time-point. A calibration coeffici...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.12.125005

    authors: Li Z,Baker WB,Parthasarathy AB,Ko TS,Wang D,Schenkel S,Durduran T,Li G,Yodh AG

    更新日期:2015-01-01 00:00:00

  • Two-photon microscopy of cortical NADH fluorescence intensity changes: correcting contamination from the hemodynamic response.

    abstract::Quantification of nicotinamide adenine dinucleotide (NADH) changes during functional brain activation and pathological conditions provides critical insight into brain metabolism. Of the different imaging modalities, two-photon laser scanning microscopy (TPLSM) is becoming an important tool for cellular-resolution meas...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3633339

    authors: Baraghis E,Devor A,Fang Q,Srinivasan VJ,Wu W,Lesage F,Ayata C,Kasischke KA,Boas DA,Sakadzić S

    更新日期:2011-10-01 00:00:00

  • Correlation of in vivo photosensitizer fluorescence and photodynamic-therapy-induced depth of necrosis in a murine tumor model.

    abstract::We compared light-induced fluorescence (LIF) to nominal injected drug dose for predicting the depth of necrosis response to photodynamic therapy (PDT) in a murine tumor model. Mice were implanted with radiation-induced fibrosarcoma (RIF) and were injected with 0, 5, or 10 mg/kg Photofrin. 630-nm light (30 J/cm(2), 75 ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1560011

    authors: Cheung R,Solonenko M,Busch TM,Del Piero F,Putt ME,Hahn SM,Yodh AG

    更新日期:2003-04-01 00:00:00

  • Colloidal mesoporous silica nanoparticles with protoporphyrin IX encapsulated for photodynamic therapy.

    abstract::Protoporphyrin IX (PpIX)-encapsulated mesoporous silica nanoparticles were synthesized, characterized, and utilized for photodynamic therapy (PDT) of cancer. Silica encapsulation is relatively transparent for activated light and can protect the PpIX against denaturation induced by the extreme bioenvironment. The mesop...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3083427

    authors: Qian J,Gharibi A,He S

    更新日期:2009-01-01 00:00:00

  • Shear wave elastography using amplitude-modulated acoustic radiation force and phase-sensitive optical coherence tomography.

    abstract::Investigating the elasticity of ocular tissue (cornea and intraocular lens) could help the understanding and management of pathologies related to biomechanical deficiency. In previous studies, we introduced a setup based on optical coherence tomography for shear wave elastography (SWE) with high resolution and high se...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.1.016001

    authors: Nguyen TM,Arnal B,Song S,Huang Z,Wang RK,O'Donnell M

    更新日期:2015-01-01 00:00:00

  • Clinical study of noninvasive in vivo melanoma and nonmelanoma skin cancers using multimodal spectral diagnosis.

    abstract::The goal of this study was to determine the diagnostic capability of a multimodal spectral diagnosis (SD) for in vivo noninvasive disease diagnosis of melanoma and nonmelanoma skin cancers. We acquired reflectance, fluorescence, and Raman spectra from 137 lesions in 76 patients using custom-built optical fiber-based c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.117003

    authors: Lim L,Nichols B,Migden MR,Rajaram N,Reichenberg JS,Markey MK,Ross MI,Tunnell JW

    更新日期:2014-01-01 00:00:00

  • Optimal optode montage on electroencephalography/functional near-infrared spectroscopy caps dedicated to study epileptic discharges.

    abstract::Functional near-infrared spectroscopy (fNIRS), acquired simultaneously with electroencephalography (EEG), allows the investigation of hemodynamic brain responses to epileptic activity. Because the presumed epileptogenic focus is patient-specific, an appropriate source/detector (SD) montage has to be reconfigured for e...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.2.026010

    authors: Machado A,Marcotte O,Lina JM,Kobayashi E,Grova C

    更新日期:2014-02-01 00:00:00

  • Fluidic lens laparoscopic zoom camera for minimally invasive surgery.

    abstract::This work reports a miniaturized laparoscopic zoom camera that can significantly improve vision for minimally invasive surgery (MIS), also known as laparoscopic surgery. The laparoscopic zoom camera contains bioinspired fluidic lenses that can change curvature and focal length in a manner similar to the crystalline le...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3420192

    authors: Tsai FS,Johnson D,Francis CS,Cho SH,Qiao W,Arianpour A,Mintz Y,Horgan S,Talamini M,Lo YH

    更新日期:2010-05-01 00:00:00

  • Retinal response of Macaca mulatta to picosecond laser pulses of varying energy and spot size.

    abstract::We investigate the relationship between the laser beam at the retina (spot size) and the extent of retinal injury from single ultrashort laser pulses. From previous studies it is believed that the retinal effect of single 3-ps laser pulses should vary in extent and location, depending on the occurrence of laser-induce...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1805554

    authors: Roach WP,Cain CP,Narayan DG,Noojin GD,Boppart SA,Birngruber R,Fujimoto JG,Toth CA

    更新日期:2004-11-01 00:00:00

  • Development of single-channel optical video stereomicroscopy.

    abstract::This study introduces a single-channel optical video stereomicroscope based on a transparent rotating deflector (TRD) for high-resolution and high-magnification stereomicroscopy. The existing stereomicroscopes have some limitations, such as limited resolution and magnification, fixed optical channel, and the necessity...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.126001

    authors: Radfar E,Park J,Jung B

    更新日期:2016-12-01 00:00:00

  • Optical oximetry of volume-oscillating vascular compartments: contributions from oscillatory blood flow.

    abstract::We present a quantitative analysis of dynamic diffuse optical measurements to obtain oxygen saturation of hemoglobin in volume oscillating compartments. We used a phasor representation of oscillatory hemodynamics at the heart rate and respiration frequency to separate the oscillations of tissue concentrations of oxyhe...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.10.101408

    authors: Kainerstorfer JM,Sassaroli A,Fantini S

    更新日期:2016-10-01 00:00:00

  • Time-reversed ultrasonically encoded optical focusing using two ultrasonic transducers for improved ultrasonic axial resolution.

    abstract::Focusing light inside highly scattering media is a challenging task in biomedical optical imaging, manipulation, and therapy. A recent invention has overcome this challenge by time reversing ultrasonically encoded diffuse light to an ultrasound-modulated volume inside a turbid medium. In this technique, a photorefract...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.11.110502

    authors: Yang Q,Xu X,Lai P,Xu D,Wang LV

    更新日期:2013-11-01 00:00:00

  • Rab4 and Rab11 coordinately regulate the recycling of angiotensin II type I receptor as demonstrated by fluorescence resonance energy transfer microscopy.

    abstract::The recycling of G-protein-coupled receptors (GPCR) to the cell surface after internalization plays an important role in the regulation of overall GPCR activity. The angiotensin II type I receptor (AT1R) belongs to class B GPCRs that recycle slowly back to the cell surface. Previous studies have proposed that Rab11 co...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2943286

    authors: Li H,Li HF,Felder RA,Periasamy A,Jose PA

    更新日期:2008-05-01 00:00:00

  • Spatially confined and temporally resolved refractive index and scattering evaluation in human skin performed with optical coherence tomography.

    abstract::In the present applications of optical coherence tomography (OCT), parameters besides pure morphology are evaluated in skin tissue under in vivo conditions. Spatially mapped refractive indices and scattering coefficients may support tissue characterization for research and diagnostic purposes in cosmetics/pharmacy and...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.429972

    authors: Knüttel A,Boehlau-Godau M

    更新日期:2000-01-01 00:00:00

  • Augmented microscopy: real-time overlay of bright-field and near-infrared fluorescence images.

    abstract::Intraoperative applications of near-infrared (NIR) fluorescent contrast agents can be aided by instrumentation capable of merging the view of surgical field with that of NIR fluorescence. We demonstrate augmented microscopy, an intraoperative imaging technique in which bright-field (real) and electronically processed ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.10.106002

    authors: Watson JR,Gainer CF,Martirosyan N,Skoch J,Lemole GM Jr,Anton R,Romanowski M

    更新日期:2015-10-01 00:00:00

  • Swept-source optical coherence tomography powered by a 1.3-μm vertical cavity surface emitting laser enables 2.3-mm-deep brain imaging in mice in vivo.

    abstract::We report noninvasive, in vivo optical imaging deep within a mouse brain by swept-source optical coherence tomography (SS-OCT), enabled by a 1.3-μm vertical cavity surface emitting laser (VCSEL). VCSEL SS-OCT offers a constant signal sensitivity of 105 dB throughout an entire depth of 4.25 mm in air, ensuring an exten...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.10.106004

    authors: Choi WJ,Wang RK

    更新日期:2015-10-01 00:00:00

  • Anomalous photobleaching in fluorescence recovery after photobleaching measurements due to excitation saturation--a case study for fluorescein.

    abstract::In this study we examine the implications of excitation saturation on fluorescence recovery after photobleaching (FRAP) experiments. In particular we present both experimental and theoretical evidence that fluorescein, one of the most frequently used fluorophores in FRAP, does not always comply with the basic assumpti...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2337531

    authors: Braeckmans K,Stubbe BG,Remaut K,Demeester J,De Smedt SC

    更新日期:2006-07-01 00:00:00

  • Dynamic performance of microelectromechanical systems deformable mirrors for use in an active/adaptive two-photon microscope.

    abstract::Active optics such as deformable mirrors can be used to control both focal depth and aberrations during scanning laser microscopy. If the focal depth can be changed dynamically during scanning, then imaging of oblique surfaces becomes possible. If aberrations can be corrected dynamically during scanning, an image can ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.121507

    authors: Archer-Zhang CC,Foster WB,Downey RD,Arrasmith CL,Dickensheets DL

    更新日期:2016-12-01 00:00:00

  • Miniature endoscopic optical coherence tomography probe employing a two-axis microelectromechanical scanning mirror with through-silicon vias.

    abstract::We present the design and experimental results of a new MEMS-based endoscopic optical coherence tomography (OCT) probe. The uniqueness of this miniature OCT imaging probe is a two-axis MEMS mirror with through-silicon vias (TSVs) for interconnecting. The TSV interconnection enables ultracompact probe design, successfu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3533323

    authors: Liu L,Wu L,Sun J,Lin E,Xie H

    更新日期:2011-02-01 00:00:00

  • Multimodal optical microscope for detecting viability of mouse embryos in vitro.

    abstract::We present a multimodal optical microscope that incorporates six imaging modalities on one common platform. The imaging modalities include three staring modes, optical quadrature microscopy (OQM), differential interference contrast (DIC) microscopy, and epi-fluorescence microscopy, and three scanning modes, confocal r...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2753744

    authors: Warger WC 2nd,Laevsky GS,Townsend DJ,Rajadhyaksha M,DiMarzio CA

    更新日期:2007-07-01 00:00:00

  • Optical properties of adenocarcinoma and squamous cell carcinoma of the gastroesophageal junction.

    abstract::Photodynamic therapy (PDT) is an alternative to radical surgical resection for T1a or nonresectable carcinomas of the gastroesophageal junction. Besides the concentration of the photosensitizer, the light distribution in tissue is responsible for tumor destruction. For this reason, knowledge about the behavior of ligh...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2564793

    authors: Holmer C,Lehmann KS,Wanken J,Reissfelder C,Roggan A,Mueller G,Buhr HJ,Ritz JP

    更新日期:2007-01-01 00:00:00

  • Photoacoustic properties of anterior ocular tissues.

    abstract::Clinical imaging techniques for the anterior segment of the eye provide excellent anatomical information, but molecular imaging techniques are lacking. Molecular photoacoustic imaging is one option to address this need, but implementation requires use of contrast agents to distinguish molecular targets from background...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.5.056004

    authors: Kubelick KP,Snider EJ,Ethier CR,Emelianov S

    更新日期:2019-05-01 00:00:00

  • Eigenvector-based spatial filtering for reduction of physiological interference in diffuse optical imaging.

    abstract::Diffuse optical imaging is an effective technique for noninvasive functional brain imaging. However, the measurements respond to systemic hemodynamic fluctuations caused by the cardiac cycle, respiration, and blood pressure, which may obscure or overwhelm the desired stimulus-evoked response. Previous work on this pro...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1852552

    authors: Zhang Y,Brooks DH,Franceschini MA,Boas DA

    更新日期:2005-01-01 00:00:00

  • Measuring red blood cell flow dynamics in a glass capillary using Doppler optical coherence tomography and Doppler amplitude optical coherence tomography.

    abstract::Blood, being a suspension of deformable red cells suspended in plasma, displays flow dynamics considerably more complicated than those of an ideal Newtonian fluid. Flow dynamics in blood capillaries of a few hundred micrometers in diameter are investigated using Doppler optical coherence tomography (DOCT) and Doppler ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1781163

    authors: Moger J,Matcher SJ,Winlove CP,Shore A

    更新日期:2004-09-01 00:00:00

  • Handheld projective imaging device for near-infrared fluorescence imaging and intraoperative guidance of sentinel lymph node resection.

    abstract::We propose a handheld projective imaging device for orthotopic projection of near-infrared fluorescence images onto target biological tissue at visible wavelengths without any additional visual aid. The device integrates a laser diode light source module, a camera module, a projector, an ultrasonic distance sensor, a ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.8.080503

    authors: Li C,Liu P,Shao P,Pei J,Li Y,Pawlik TM,Martin EW,Xu RX

    更新日期:2019-08-01 00:00:00