Toward optical guidance during endoscopic ultrasound-guided fine needle aspirations of pancreatic masses using single fiber reflectance spectroscopy: a feasibility study.

Abstract:

:Endoscopic ultrasound-guided fine needle aspirations (EUS-FNA) of pancreatic masses suffer from sample errors and low-negative predictive values. Fiber-optic spectroscopy in the visible to near-infrared wavelength spectrum can noninvasively extract physiological parameters from tissue and has the potential to guide the sampling process and reduce sample errors. We assessed the feasibility of single fiber (SF) reflectance spectroscopy measurements during EUS-FNA of pancreatic masses and its ability to distinguish benign from malignant pancreatic tissue. A single optical fiber was placed inside a 19-gauge biopsy needle during EUS-FNA and at least three reflectance measurements were taken prior to FNA. Spectroscopy measurements did not cause any related adverse events and prolonged procedure time with ? 5 ?? min . An accurate correlation between spectroscopy measurements and cytology could be made in nine patients (three benign and six malignant). The oxygen saturation and bilirubin concentration were significantly higher in benign tissue compared with malignant tissue (55% versus 21%, p = 0.038 ; 166 ?? ? mol / L versus 17 ?? ? mol / L , p = 0.039 , respectively). To conclude, incorporation of SF spectroscopy during EUS-FNA was feasible, safe, and relatively quick to perform. The optical properties of benign and malignant pancreatic tissue are different, implying that SF spectroscopy can potentially guide the FNA sampling.

journal_name

J Biomed Opt

authors

Stegehuis PL,Boogerd LS,Inderson A,Veenendaal RA,van Gerven P,Bonsing BA,Sven Mieog J,Amelink A,Veselic M,Morreau H,van de Velde CJ,Lelieveldt BP,Dijkstra J,Robinson DJ,Vahrmeijer AL

doi

10.1117/1.JBO.22.2.024001

subject

Has Abstract

pub_date

2017-02-01 00:00:00

pages

24001

issue

2

eissn

1083-3668

issn

1560-2281

pii

2601697

journal_volume

22

pub_type

杂志文章
  • Context encoding enables machine learning-based quantitative photoacoustics.

    abstract::Real-time monitoring of functional tissue parameters, such as local blood oxygenation, based on optical imaging could provide groundbreaking advances in the diagnosis and interventional therapy of various diseases. Although photoacoustic (PA) imaging is a modality with great potential to measure optical absorption dee...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.5.056008

    authors: Kirchner T,Gröhl J,Maier-Hein L

    更新日期:2018-05-01 00:00:00

  • Temperature changes on the root surfaces of mandibular incisors after an 810-nm high-intensity intracanal diode laser irradiation.

    abstract:UNLABELLED:Temperature changes caused by laser irradiation can promote damage to the surrounding dental tissues. In this study, we evaluated the temperature changes of recently extracted human mandibular incisors during intracanal irradiation with an 810-nm diode laser at different settings. Fifty mandibular incisors w...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.1.015006

    authors: da Fonseca Alvarez A,Moura-Netto C,Daliberto Frugoli A,Fernando C,Aranha AC,Davidowicz H

    更新日期:2012-01-01 00:00:00

  • Characterization of retinal biomechanical properties using Brillouin microscopy.

    abstract:SIGNIFICANCE:The retina is critical for vision, and several diseases may alter its biomechanical properties. However, assessing the biomechanical properties of the retina nondestructively is a challenge due to its fragile nature and location within the eye globe. Advancements in Brillouin spectroscopy have provided the...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.9.090502

    authors: Ambekar YS,Singh M,Scarcelli G,Rueda EM,Hall BM,Poché RA,Larin KV

    更新日期:2020-09-01 00:00:00

  • Potential of optical microangiography to monitor cerebral blood perfusion and vascular plasticity following traumatic brain injury in mice in vivo.

    abstract::Optical microanglography (OMAG) is a recently developed imaging modality capable of volumetric imaging of dynamic blood perfusion, down to capillary level resolution, with an imaging depth up to 2.00 mm beneath the tissue surface. We report the use of OMAG to monitor the cerebral blood flow (CBF) over the cortex of mo...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3207121

    authors: Jia Y,Alkayed N,Wang RK

    更新日期:2009-07-01 00:00:00

  • Classification of skin moles from optical spectropolarimetric images: a pilot study.

    abstract::A new skin-imaging method, which was developed recently, gives an informative image data about skin moles by collecting scattered polarized light reflected from their tissue area at different wavelengths and polarizations. This method is called as optical rotational spectropolarimetric imaging (ORSI), which scans the ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.11.111403

    authors: Graham L,Yitzhaky Y,Abdulhalim I

    更新日期:2013-11-01 00:00:00

  • Listening to membrane potential: photoacoustic voltage-sensitive dye recording.

    abstract::Voltage-sensitive dyes (VSDs) are designed to monitor membrane potential by detecting fluorescence changes in response to neuronal or muscle electrical activity. However, fluorescence imaging is limited by depth of penetration and high scattering losses, which leads to low sensitivity in vivo systems for external dete...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.4.045006

    authors: Zhang HK,Yan P,Kang J,Abou DS,Le HN,Jha AK,Thorek DL,Kang JU,Rahmim A,Wong DF,Boctor EM,Loew LM

    更新日期:2017-04-01 00:00:00

  • Image analysis methods for diffuse optical tomography.

    abstract::Three major analytical tools in imaging science are summarized and demonstrated relative to optical imaging in vivo. Standard resolution testing is optimal when infinite contrast is used and hardware evaluation is the goal. However, deep tissue imaging of absorption or fluorescent contrast agents in vivo often present...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.2209908

    authors: Pogue BW,Davis SC,Song X,Brooksby BA,Dehghani H,Paulsen KD

    更新日期:2006-05-01 00:00:00

  • Modulation transfer function measurement of scanning reflectance microscopes.

    abstract::Real-time medical imaging systems such as reflectance confocal microscopes and optical coherence microscopes are being tested in multiple-patient and multiple-center clinical trials. The modulation transfer function (MTF) of these systems at any given time influences the image information content and can affect the in...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2779352

    authors: Wang Z,Glazowski CE,Zavislan JM

    更新日期:2007-09-01 00:00:00

  • Temperature-modulated fluorescence tomography based on both concentration and lifetime contrast.

    abstract::It is challenging to image fluorescence objects with high spatial resolution in a highly scattering medium. Recently reported temperature-sensitive indocyanine green-loaded pluronic nanocapsules can potentially alleviate this problem. Here we demonstrate a frequency-domain temperature-modulated fluorescence tomography...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.5.056007

    authors: Lin Y,Kwong TC,Bolisay L,Gulsen G

    更新日期:2012-05-01 00:00:00

  • Compact instrument for fluorescence image-guided surgery.

    abstract::Fluorescence image-guided surgery (FIGS) is an emerging technique in oncology, neurology, and cardiology. To adapt intraoperative imaging for various surgical applications, increasingly flexible and compact FIGS instruments are necessary. We present a compact, portable FIGS system and demonstrate its use in cardiovasc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3378128

    authors: Wang X,Bhaumik S,Li Q,Staudinger VP,Yazdanfar S

    更新日期:2010-03-01 00:00:00

  • Time-dependent blood flow and oxygenation in human skeletal muscles measured with noninvasive near-infrared diffuse optical spectroscopies.

    abstract::We have employed near-infrared optical methods to measure noninvasively the dynamics of muscle blood flow and oxygen saturation (StO2) during cuff occlusion and plantar flexion exercise. Relative muscle oxygen consumption (rVO2) was also computed from these data. Diffuse correlation spectroscopy provides information a...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1884603

    authors: Yu G,Durduran T,Lech G,Zhou C,Chance B,Mohler ER 3rd,Yodh AG

    更新日期:2005-03-01 00:00:00

  • Fiber optic biosensor for the detection of C-reactive protein and the study of protein binding kinetics.

    abstract::Application of a fiber optic biosensor (FOB) to the real-time investigation of the interaction kinetics between FITC-conjugated monoclonal sheep anti-human C-reactive protein (CRP) antibody and CRP isoforms on the surface of optical fiber is described. Recently, both the native pentameric CRP (pCRP), an acute phase pr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714029

    authors: Chou C,Hsu HY,Wu HT,Tseng KY,Chiou A,Yu CJ,Lee ZY,Chan TS

    更新日期:2007-03-01 00:00:00

  • Volume holographic imaging endoscopic design and construction techniques.

    abstract::A reflectance volume holographic imaging (VHI) endoscope has been designed for simultaneous in vivo imaging of surface and subsurface tissue structures. Prior utilization of VHI systems has been limited to ex vivo tissue imaging. The VHI system presented in this work is designed for laparoscopic use. It consists of a ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.5.056010

    authors: Howlett ID,Han W,Gordon M,Rice P,Barton JK,Kostuk RK

    更新日期:2017-05-01 00:00:00

  • Selecting optimal spectral bands for improved detection of autofluorescent biomarkers in multiphoton microscopy.

    abstract:SIGNIFICANCE:In multiphoton microscopy, two-photon excited fluorescence (TPEF) spectra carry valuable information on morphological and functional biological features. For measuring these biomarkers, separation of different parts of the fluorescence spectrum into channels is typically achieved by the use of optical band...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.7.071206

    authors: Meyer BO,Stella MPJ,Holst B,Nielsen BS,Holmstrøm K,Andersen PE,Marti D

    更新日期:2020-07-01 00:00:00

  • Temperature-controlled in vivo ocular exposure to 1090-nm radiation suggests that near-infrared radiation cataract is thermally induced.

    abstract::The damage mechanism for near-infrared radiation (IRR) induced cataract is unclear. Both a photochemical and a thermal mechanism were suggested. The current paper aims to elucidate a photochemical effect based on investigation of irradiance-exposure time reciprocity. Groups of 20 rats were unilaterally exposed to 96-W...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.1.015003

    authors: Yu Z,Schulmeister K,Talebizadeh N,Kronschläger M,Söderberg P

    更新日期:2015-01-01 00:00:00

  • Mapping cisplatin-induced viscosity alterations in cancer cells using molecular rotor and fluorescence lifetime imaging microscopy.

    abstract:SIGNIFICANCE:Despite the importance of the cell membrane in regulation of drug activity, the influence of drug treatments on its physical properties is still poorly understood. The combination of fluorescence lifetime imaging microscopy (FLIM) with specific viscosity-sensitive fluorescent molecular rotors allows the qu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.12.126004

    authors: Shimolina LE,Gulin AA,Paez-Perez M,López-Duarte I,Druzhkova IN,Lukina MM,Gubina MV,Brooks NJ,Zagaynova EV,Kuimova MK,Shirmanova MV

    更新日期:2020-12-01 00:00:00

  • Nondestructive inspection of phase transformation in zirconia-containing hip joints by confocal Raman spectroscopy.

    abstract::Environmental metastability of zirconia (ZrO2) ceramic in the human body [represented by a tetragonal-to-monoclinic (t→m) phase transformation] takes place on the surface of the artificial joint and proceeds with time toward its interior. Its quantitative characterization is mandatory for the safety of joint implants ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.12.127002

    authors: Zhu W,Sugano N,Pezzotti G

    更新日期:2013-12-01 00:00:00

  • Quantitative assessment of radiation-induced changes of bladder and rectum collagen structure using optical methods.

    abstract::The objective of the study is the quantitative analysis of the dose-time dependences of changes occurring in collagen of bladder and rectum after gamma-irradiation using optical methods [nonlinear microscopy in a second harmonic generation (SHG) detection regime and cross-polarization optical coherence tomography (CP ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.9.091417

    authors: Kochueva M,Dudenkova V,Kuznetsov S,Varlamova A,Sergeeva E,Kiseleva E,Maslennikova A

    更新日期:2018-08-01 00:00:00

  • Determination of optical properties of human blood in the spectral range 250 to 1100 nm using Monte Carlo simulations with hematocrit-dependent effective scattering phase functions.

    abstract::The absorption coefficient mu(a), scattering coefficient mu(s), and anisotropy factor g of diluted and undiluted human blood (hematocrit 0.84 and 42.1%) are determined under flow conditions in the wavelength range 250 to 1100 nm, covering the absorption bands of hemoglobin. These values are obtained by high precision ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2203659

    authors: Friebel M,Roggan A,Müller G,Meinke M

    更新日期:2006-05-01 00:00:00

  • Performance of a lookup table-based approach for measuring tissue optical properties with diffuse optical spectroscopy.

    abstract::Diffuse optical spectroscopy (DOS) provides a powerful tool for fast and noninvasive disease diagnosis. The ability to leverage DOS to accurately quantify tissue optical parameters hinges on the model used to estimate light-tissue interaction. We describe the accuracy of a lookup table (LUT)-based inverse model for me...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.5.057001

    authors: Nichols BS,Rajaram N,Tunnell JW

    更新日期:2012-05-01 00:00:00

  • Second-harmonic generation in collagen as a potential cancer diagnostic parameter.

    abstract::The fibrillar collagen network in tumor and normal tissues is different due to remodeling of the extracellular matrix during the malignant process. Collagen type I fibers have the crystalline and noncentrosymmetric properties required for generating the second-harmonic signal. The content and structure of collagen wer...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2983664

    authors: Hompland T,Erikson A,Lindgren M,Lindmo T,de Lange Davies C

    更新日期:2008-09-01 00:00:00

  • Antibody-based magnetic nanoparticle immunoassay for quantification of Alzheimer's disease pathogenic factor.

    abstract::Alzheimer's disease (AD) is a neurodegenerative disorder that leads to a decline in cognitive and intellectual abilities and an irreversible mental deterioration. Based on multidisciplinary AD research, the most universally accepted hypotheses on AD pathogenesis are the intracerebral aggregate formation of beta-amyloi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.5.051205

    authors: Kim CB,Choi YY,Song WK,Song KB

    更新日期:2014-05-01 00:00:00

  • Depth profiling of photothermal compound concentrations using phase sensitive optical coherence tomography.

    abstract::A model that describes the concentration of photothermal (light-to-heat converters) compounds as a function of depth in a turbid medium is developed. The system consists of a pump laser (808 nm modulated at 400 Hz), which heats a photothermal compound, and a phase sensitive spectral domain optical coherence tomography...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3659211

    authors: Guan G,Reif R,Huang Z,Wang RK

    更新日期:2011-12-01 00:00:00

  • Holographic analysis on deformation and restoration of malaria-infected red blood cells by antimalarial drug.

    abstract::Malaria parasites induce morphological, biochemical, and mechanical changes in red blood cells (RBCs). Mechanical variations are closely related to the deformability of individual RBCs. The deformation of various RBCs, including healthy and malaria-infected RBCs (iRBCs), can be directly observed through quantitative p...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.11.115003

    authors: Byeon H,Ha YR,Lee SJ

    更新日期:2015-11-01 00:00:00

  • Cellular resolution ex vivo imaging of gastrointestinal tissues with optical coherence microscopy.

    abstract::Optical coherence microscopy (OCM) combines confocal microscopy and optical coherence tomography (OCT) to improve imaging depth and contrast, enabling cellular imaging in human tissues. We aim to investigate OCM for ex vivo imaging of upper and lower gastrointestinal tract tissues, to establish correlations between OC...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3322704

    authors: Aguirre AD,Chen Y,Bryan B,Mashimo H,Huang Q,Connolly JL,Fujimoto JG

    更新日期:2010-01-01 00:00:00

  • Application of biospeckles for assessment of structural and cellular changes in muscle tissue.

    abstract::A modified spatial-temporal speckle correlation technique for operational assessment of structural changes in muscle tissues after slaughtering is considered. Coefficient of biological activity as a quantitative indicator of structural changes of biochemical processes in biological tissues is proposed. The experimenta...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.9.095006

    authors: Maksymenko OP,Muravsky LI,Berezyuk MI

    更新日期:2015-09-01 00:00:00

  • Characterization of a multicore fiber image guide for nonlinear endoscopic imaging using two-photon fluorescence and second-harmonic generation.

    abstract::Multiphoton microscopy (MPM) has the capacity to record second-harmonic generation (SHG) and endogenous two-photon excitation fluorescence (2PEF) signals emitted from biological tissues. The development of fiber-based miniaturized endomicroscopes delivering pulses in the femtosecond range will allow the transfer of MP...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.10.106004

    authors: Garofalakis A,Kruglik SG,Mansuryan T,Gillibert A,Thiberville L,Louradour F,Vever-Bizet C,Bourg-Heckly G

    更新日期:2019-10-01 00:00:00

  • Sensing dynamic cytoplasm refractive index changes of adherent cells with quantitative phase microscopy using incorporated microspheres as optical probes.

    abstract::The intracellular refractive index is an important parameter that describes the optical density of the cytoplasm and the concentration of the intracellular solutes. The refractive index of adherently grown cells is difficult to access. We present a method in which silica microspheres in living cells are used to determ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.9.097001

    authors: Przibilla S,Dartmann S,Vollmer A,Ketelhut S,Greve B,von Bally G,Kemper B

    更新日期:2012-09-01 00:00:00

  • Digital phantoms generated by spectral and spatial light modulators.

    abstract::A hyperspectral image projector (HIP) based on liquid crystal on silicon spatial light modulators is explained and demonstrated to generate data cubes. The HIP-constructed data cubes are three-dimensional images of the spatial distribution of spectrally resolved abundances of intracellular light-absorbing oxyhemoglobi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,收录出版

    doi:10.1117/1.JBO.20.11.111215

    authors: Chon B,Tokumasu F,Lee JY,Allen DW,Rice JP,Hwang J

    更新日期:2015-01-01 00:00:00

  • Subcellular imaging of epithelium with time-lapse optical coherence tomography.

    abstract::We present the first experimental result of direct delineation of the nuclei of living rat bladder epithelium with ultrahigh-resolution optical coherence tomography (uOCT). We demonstrate that the cellular details embedded in the speckle noise in a uOCT image can be uncovered by time-lapse frame averaging that takes a...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.2800007

    authors: Pan YT,Wu ZL,Yuan ZJ,Wang ZG,Du CW

    更新日期:2007-09-01 00:00:00