Imaging caries lesions and lesion progression with polarization sensitive optical coherence tomography.

Abstract:

:New diagnostic tools are needed for the characterization of dental caries in the early stages of development. If carious lesions are detected early enough, they can be arrested without the need for surgical intervention. The objective of this study was to demonstrate that polarization sensitive optical coherence tomography (PS-OCT) can be used for the imaging of early caries lesions and for the monitoring of lesion progression over time. High-resolution polarization resolved images were acquired of natural caries lesions and simulated caries lesions of varying severity created over time periods of 1 to 14 days. Linearly polarized light was incident on the tooth samples and the reflected intensity in both orthogonal polarizations was measured. PS-OCT was invaluable for removing the confounding influence of surface reflections and native birefringence necessary for the enhanced resolution of the surface structure of caries lesions. This study demonstrated that PS-OCT is well suited for the imaging of interproximal and occlusal caries, early root caries, and for imaging decay under composite fillings. Longitudinal measurements of the reflected light intensity in the orthogonal polarization state from the area of simulated caries lesions linearly correlated with the square root of time of demineralization indicating that PS-OCT is well suited for monitoring changes in enamel mineralization over time.

journal_name

J Biomed Opt

authors

Fried D,Xie J,Shafi S,Featherstone JD,Breunig TM,Le C

doi

10.1117/1.1509752

subject

Has Abstract

pub_date

2002-10-01 00:00:00

pages

618-27

issue

4

eissn

1083-3668

issn

1560-2281

journal_volume

7

pub_type

杂志文章
  • Optical power transfer and communication methods for wireless implantable sensing platforms.

    abstract::Ultrasmall scale implants have recently attracted focus as valuable tools for monitoring both acute and chronic diseases. Semiconductor optical technologies are the key to miniaturizing these devices to the long-sought sub-mm scale, which will enable long-term use of these devices for medical applications. This can al...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.9.095012

    authors: Mujeeb-U-Rahman M,Adalian D,Chang CF,Scherer A

    更新日期:2015-09-01 00:00:00

  • Review of diverse optical fibers used in biomedical research and clinical practice.

    abstract::Optical fiber technology has significantly bolstered the growth of photonics applications in basic life sciences research and in biomedical diagnosis, therapy, monitoring, and surgery. The unique operational characteristics of diverse fibers have been exploited to realize advanced biomedical functions in areas such as...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.19.8.080902

    authors: Keiser G,Xiong F,Cui Y,Shum PP

    更新日期:2014-08-01 00:00:00

  • Time-reversed ultrasonically encoded optical focusing using two ultrasonic transducers for improved ultrasonic axial resolution.

    abstract::Focusing light inside highly scattering media is a challenging task in biomedical optical imaging, manipulation, and therapy. A recent invention has overcome this challenge by time reversing ultrasonically encoded diffuse light to an ultrasound-modulated volume inside a turbid medium. In this technique, a photorefract...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.11.110502

    authors: Yang Q,Xu X,Lai P,Xu D,Wang LV

    更新日期:2013-11-01 00:00:00

  • Screening for the breast cancer gene (BRCA1) using a biochip system and molecular beacon probes immobilized on solid surfaces.

    abstract::We describe the use of a biochip based on complementary metal oxide semiconductor (CMOS) technology for detection of specific genetic sequences using molecular beacons (MB) immobilized on solid surfaces as probes. The applicability of this miniature detection system for screening for the BRCA1 gene is evaluated using ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1691025

    authors: Culha M,Stokes DL,Griffin GD,Vo-Dinh T

    更新日期:2004-05-01 00:00:00

  • Measuring red blood cell flow dynamics in a glass capillary using Doppler optical coherence tomography and Doppler amplitude optical coherence tomography.

    abstract::Blood, being a suspension of deformable red cells suspended in plasma, displays flow dynamics considerably more complicated than those of an ideal Newtonian fluid. Flow dynamics in blood capillaries of a few hundred micrometers in diameter are investigated using Doppler optical coherence tomography (DOCT) and Doppler ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1781163

    authors: Moger J,Matcher SJ,Winlove CP,Shore A

    更新日期:2004-09-01 00:00:00

  • Biocompatible semiconductor optoelectronics.

    abstract::We investigate optoelectronic properties of integrated structures comprising semiconductor light-emitting materials for optical probes of microscopic biological systems. Compound semiconductors are nearly ideal light emitters for probing cells and other microorganisms because of their spectral match to the transparenc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1506931

    authors: Gourley PL,Copeland RG,Cox JD,Hendricks JK,McDonald AE,Peterson SL,Sasaki DY

    更新日期:2002-10-01 00:00:00

  • Dynamics of retinal photocoagulation and rupture.

    abstract::In laser retinal photocoagulation, short (<20 ms) pulses have been found to reduce thermal damage to the inner retina, decrease treatment time, and minimize pain. However, the safe therapeutic window (defined as the ratio of power for producing a rupture to that of mild coagulation) decreases with shorter exposures. T...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3130282

    authors: Sramek C,Paulus Y,Nomoto H,Huie P,Brown J,Palanker D

    更新日期:2009-05-01 00:00:00

  • Voxel-based measurement sensitivity of spatially resolved near-infrared spectroscopy in layered tissues.

    abstract::We quantitatively investigated the measurement sensitivity of spatially resolved spectroscopy (SRS) across six tissue models: cerebral tissue, a small animal brain, the forehead of a fetus, an adult brain, forearm muscle, and thigh muscle. The optical path length in the voxel of the model was analyzed using Monte Carl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.3.030503

    authors: Niwayama M

    更新日期:2018-03-01 00:00:00

  • In vivo assessment and evaluation of lung tissue morphologic and physiological changes from non-contact endoscopic reflectance spectroscopy for improving lung cancer detection.

    abstract::We present a method for lung cancer detection exploiting reflectance spectra measured in vivo during endoscopic imaging of the lung. The measured reflectance spectra were analyzed using a specially developed light-transport model to obtain quantitative information about cancer-related, physiological, and morphologic c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2337529

    authors: Fawzy YS,Petek M,Tercelj M,Zeng H

    更新日期:2006-07-01 00:00:00

  • Real-time full-field photoacoustic imaging using an ultrasonic camera.

    abstract::A photoacoustic imaging system that incorporates a commercial ultrasonic camera for real-time imaging of two-dimensional (2-D) projection planes in tissue at video rate (30 Hz) is presented. The system uses a Q-switched frequency-doubled Nd:YAG pulsed laser for photoacoustic generation. The ultrasonic camera consists ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3420079

    authors: Balogun O,Regez B,Zhang HF,Krishnaswamy S

    更新日期:2010-03-01 00:00:00

  • In vivo near-infrared dual-axis confocal microendoscopy in the human lower gastrointestinal tract.

    abstract::Near-infrared confocal microendoscopy is a promising technique for deep in vivo imaging of tissues and can generate high-resolution cross-sectional images at the micron-scale. We demonstrate the use of a dual-axis confocal (DAC) near-infrared fluorescence microendoscope with a 5.5-mm outer diameter for obtaining clini...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.2.021102

    authors: Piyawattanametha W,Ra H,Qiu Z,Friedland S,Liu JT,Loewke K,Kino GS,Solgaard O,Wang TD,Mandella MJ,Contag CH

    更新日期:2012-02-01 00:00:00

  • Perfusion assessment in rat spinal cord tissue using photoplethysmography and laser Doppler flux measurements.

    abstract::Animal models are widely used to investigate the pathological mechanisms of spinal cord injury (SCI), most commonly in rats. It is well known that compromised blood flow caused by mechanical disruption of the vasculature can produce irreversible damage and cell death in hypoperfused tissue regions and spinal cord tiss...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.037005

    authors: Phillips JP,Cibert-Goton V,Langford RM,Shortland PJ

    更新日期:2013-03-01 00:00:00

  • Time-resolved diffuse optical tomography and its application to in vitro and in vivo imaging.

    abstract::This work reviews our research during the past several years on time-resolved (TR) near-infrared diffuse optical tomography (DOT). Following an introduction of the measuring modes, two proposed schemes of image reconstruction in TR-DOT are described: one utilizes the full TR data, and the other, referred to as the mod...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.2815724

    authors: Zhao H,Gao F,Tanikawa Y,Yamada Y

    更新日期:2007-11-01 00:00:00

  • Handheld projective imaging device for near-infrared fluorescence imaging and intraoperative guidance of sentinel lymph node resection.

    abstract::We propose a handheld projective imaging device for orthotopic projection of near-infrared fluorescence images onto target biological tissue at visible wavelengths without any additional visual aid. The device integrates a laser diode light source module, a camera module, a projector, an ultrasonic distance sensor, a ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.8.080503

    authors: Li C,Liu P,Shao P,Pei J,Li Y,Pawlik TM,Martin EW,Xu RX

    更新日期:2019-08-01 00:00:00

  • Noninvasive enhanced mid-IR imaging of breast cancer development in vivo.

    abstract::Lumpectomy coupled with radiation therapy and/or chemotherapy is commonly used to treat breast cancer patients. We are developing an enhanced thermal IR imaging technique that has the potential to provide real-time imaging to guide tissue excision during a lumpectomy by delineating tumor margins. This enhanced thermal...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.11.116003

    authors: Case JR,Young MA,Dréau D,Trammell SR

    更新日期:2015-11-01 00:00:00

  • Blind deconvolution estimation of fluorescence measurements through quadratic programming.

    abstract::Time-deconvolution of the instrument response from fluorescence lifetime imaging microscopy (FLIM) data is usually necessary for accurate fluorescence lifetime estimation. In many applications, however, the instrument response is not available. In such cases, a blind deconvolution approach is required. An iterative me...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.7.075010

    authors: Campos-Delgado DU,Gutierrez-Navarro O,Arce-Santana ER,Skala MC,Walsh AJ,Jo JA

    更新日期:2015-07-01 00:00:00

  • Evaluation of hypericin-mediated photodynamic therapy in combination with angiogenesis inhibitor bevacizumab using in vivo fluorescence confocal endomicroscopy.

    abstract::Photodynamic therapy (PDT) is an alternative cancer treatment modality that offers localized treatment using a photosensitizer and light. However, tumor angiogenesis is a major concern following PDT-induced hypoxia as it promotes recurrence. Bevacizumab is a monoclonal antibody that targets vascular endothelial growth...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3281671

    authors: Bhuvaneswari R,Thong PS,Gan YY,Soo KC,Olivo M

    更新日期:2010-01-01 00:00:00

  • Real-time measurement of the vaginal pressure profile using an optical-fiber-based instrumented speculum.

    abstract::Pelvic organ prolapse (POP) occurs when changes to the pelvic organ support structures cause descent or herniation of the pelvic organs into the vagina. Clinical evaluation of POP is a series of manual measurements known as the pelvic organ prolapse quantification (POP-Q) score. However, it fails to identify the mecha...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.127008

    authors: Parkinson LA,Gargett CE,Young N,Rosamilia A,Vashi AV,Werkmeister JA,Papageorgiou AW,Arkwright JW

    更新日期:2016-12-01 00:00:00

  • Blood screening using diffraction phase cytometry.

    abstract::Blood smear analysis has remained a crucial diagnostic tool for pathologists despite the advent of automatic analyzers such as flow cytometers and impedance counters. Though these current methods have proven to be indispensible tools for physicians and researchers alike, they provide limited information on the detaile...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3369965

    authors: Mir M,Ding H,Wang Z,Reedy J,Tangella K,Popescu G

    更新日期:2010-03-01 00:00:00

  • Attenuated total reflection Fourier transform infrared and polarization spectroscopy of in vivo human skin ablated, layer by layer, by erbium:YAG laser.

    abstract::The results of an experimental study of the possibilities of monitoring erbium yttrium aluminum garnet laser-mediated ablation of human epidermis with the use of Fourier transform infrared (FTIR) spectroscopy and spectral polarization techniques are presented. The attenuated total reflection (ATR) method was used for ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1755719

    authors: Sviridov AP,Zimnyakov DA,Sinichkin YP,Butvina LN,Omelchenko AJ,Shakh GS,Bagratashvili VN

    更新日期:2004-07-01 00:00:00

  • Compact instrument for fluorescence image-guided surgery.

    abstract::Fluorescence image-guided surgery (FIGS) is an emerging technique in oncology, neurology, and cardiology. To adapt intraoperative imaging for various surgical applications, increasingly flexible and compact FIGS instruments are necessary. We present a compact, portable FIGS system and demonstrate its use in cardiovasc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3378128

    authors: Wang X,Bhaumik S,Li Q,Staudinger VP,Yazdanfar S

    更新日期:2010-03-01 00:00:00

  • Molecular interactions of exogenous chemical agents with collagen--implications for tissue optical clearing.

    abstract::Reduction of optical scattering in turbid biological tissues using nonreactive chemical agents has potential applications for light-based diagnostics and therapeutics. Optical clearing effects by exogenous chemical agents, in particular sugars and sugar alcohols, have been found to be temporary with tissue rehydration...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.2166381

    authors: Yeh AT,Hirshburg J

    更新日期:2006-01-01 00:00:00

  • Calibration of diffuse correlation spectroscopy blood flow index with venous-occlusion diffuse optical spectroscopy in skeletal muscle.

    abstract::We investigate and assess the utility of a simple scheme for continuous absolute blood flow monitoring based on diffuse correlation spectroscopy (DCS). The scheme calibrates DCS using venous-occlusion diffuse optical spectroscopy (VO-DOS) measurements of arm muscle tissue at a single time-point. A calibration coeffici...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.12.125005

    authors: Li Z,Baker WB,Parthasarathy AB,Ko TS,Wang D,Schenkel S,Durduran T,Li G,Yodh AG

    更新日期:2015-01-01 00:00:00

  • Temperature-modulated fluorescence tomography based on both concentration and lifetime contrast.

    abstract::It is challenging to image fluorescence objects with high spatial resolution in a highly scattering medium. Recently reported temperature-sensitive indocyanine green-loaded pluronic nanocapsules can potentially alleviate this problem. Here we demonstrate a frequency-domain temperature-modulated fluorescence tomography...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.5.056007

    authors: Lin Y,Kwong TC,Bolisay L,Gulsen G

    更新日期:2012-05-01 00:00:00

  • Quantitative analysis of angle-resolved scattering properties of ovarian tissue using optical coherence tomography.

    abstract::Angle-resolved optical scattering properties of ovarian tissue, on different optical coherence tomography (OCT) imaging planes, were quantitatively measured by fitting the compounded OCT A-lines into a single scattering model. Higher cross correlation value of angle-resolved scattering coefficients between different O...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.17.9.090503

    authors: Yang Y,Wang T,Brewer M,Zhu Q

    更新日期:2012-09-01 00:00:00

  • In vivo super-resolution retinal imaging through virtually structured detection.

    abstract::High resolution is important for sensitive detection of subtle distortions of retinal morphology at an early stage of eye diseases. We demonstrate virtually structured detection (VSD) as a feasible method to achieve in vivo super-resolution ophthalmoscopy. A line-scanning strategy was employed to achieve a super-resol...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.120502

    authors: Liu C,Zhi Y,Wang B,Thapa D,Chen Y,Alam M,Lu Y,Yao X

    更新日期:2016-12-01 00:00:00

  • Analysis of optically anisotropic properties of biological tissues under stretching based on differential Mueller matrix formalism.

    abstract::The optical properties of biological tissues under stretching are investigated using a full-field ellipsometry technique based on a differential Mueller matrix formalism. Traditional photoelastic-based formalism for extracting the linear birefringence (LB) properties of stretched anisotropic optical samples ignores th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.3.035006

    authors: Chen HW,Huang CL,Lo YL,Chang YR

    更新日期:2017-03-01 00:00:00

  • Spectrally resolved fluorescence lifetime imaging to investigate cell metabolism in malignant and nonmalignant oral mucosa cells.

    abstract::Fluorescence-guided diagnosis of tumor tissue is in many cases insufficient, because false positive results interfere with the outcome. Improvement through observation of cell metabolism might offer the solution, but needs a detailed understanding of the origin of autofluorescence. With respect to this, spectrally res...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.9.096005

    authors: Rück A,Hauser C,Mosch S,Kalinina S

    更新日期:2014-09-01 00:00:00

  • Pancreatic cancer cell detection by targeted lipid microbubbles and multiphoton imaging.

    abstract::Surgical resection of pancreatic cancer represents the only chance of cure and long-term survival in this common disease. Unfortunately, determination of a cancer-free margin at surgery is based on one or two tiny frozen section biopsies, which is far from ideal. Not surprisingly, cancer is usually left behind and is ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.4.046501

    authors: Cromey B,McDaniel A,Matsunaga T,Vagner J,Kieu KQ,Banerjee B

    更新日期:2018-04-01 00:00:00

  • Swept-source optical coherence tomography powered by a 1.3-μm vertical cavity surface emitting laser enables 2.3-mm-deep brain imaging in mice in vivo.

    abstract::We report noninvasive, in vivo optical imaging deep within a mouse brain by swept-source optical coherence tomography (SS-OCT), enabled by a 1.3-μm vertical cavity surface emitting laser (VCSEL). VCSEL SS-OCT offers a constant signal sensitivity of 105 dB throughout an entire depth of 4.25 mm in air, ensuring an exten...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.10.106004

    authors: Choi WJ,Wang RK

    更新日期:2015-10-01 00:00:00