Perfusion assessment in rat spinal cord tissue using photoplethysmography and laser Doppler flux measurements.

Abstract:

:Animal models are widely used to investigate the pathological mechanisms of spinal cord injury (SCI), most commonly in rats. It is well known that compromised blood flow caused by mechanical disruption of the vasculature can produce irreversible damage and cell death in hypoperfused tissue regions and spinal cord tissue is particularly susceptible to such damage. A fiberoptic photoplethysmography (PPG) probe and instrumentation system were used to investigate the practical considerations of making measurements from rat spinal cord and to assess its suitability for use in SCI models. Experiments to assess the regional perfusion of exposed spinal cord in anesthetized adult rats using both PPG and laser Doppler flowmetry (LDF) were performed. It was found that signals could be obtained reliably from all subjects, although considerable intersite and intersubject variability was seen in the PPG signal amplitude compared to LDF. We present results from 30 measurements in five subjects, the two methods are compared, and practical application to SCI animal models is discussed.

journal_name

J Biomed Opt

authors

Phillips JP,Cibert-Goton V,Langford RM,Shortland PJ

doi

10.1117/1.JBO.18.3.037005

subject

Has Abstract

pub_date

2013-03-01 00:00:00

pages

037005

issue

3

eissn

1083-3668

issn

1560-2281

pii

1663337

journal_volume

18

pub_type

杂志文章
  • Biocompatible semiconductor optoelectronics.

    abstract::We investigate optoelectronic properties of integrated structures comprising semiconductor light-emitting materials for optical probes of microscopic biological systems. Compound semiconductors are nearly ideal light emitters for probing cells and other microorganisms because of their spectral match to the transparenc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1506931

    authors: Gourley PL,Copeland RG,Cox JD,Hendricks JK,McDonald AE,Peterson SL,Sasaki DY

    更新日期:2002-10-01 00:00:00

  • In vivo assessment and evaluation of lung tissue morphologic and physiological changes from non-contact endoscopic reflectance spectroscopy for improving lung cancer detection.

    abstract::We present a method for lung cancer detection exploiting reflectance spectra measured in vivo during endoscopic imaging of the lung. The measured reflectance spectra were analyzed using a specially developed light-transport model to obtain quantitative information about cancer-related, physiological, and morphologic c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2337529

    authors: Fawzy YS,Petek M,Tercelj M,Zeng H

    更新日期:2006-07-01 00:00:00

  • Optical imaging for brain tissue characterization using relative fluorescence lifetime imaging.

    abstract::An autofluorescence lifetime wide-field imaging system that can generate contrast in underlying tissue structures of normal and malignant brain tissue samples with video rate acquisition and processing time is presented. Images of the investigated tissues were acquired with high resolution (∼35 μm) using an algorithm ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.6.060504

    authors: Papour A,Taylor Z,Sherman A,Sanchez D,Lucey G,Liau L,Stafsudd O,Yong W,Grundfest W

    更新日期:2013-06-01 00:00:00

  • System analysis of spatial frequency domain imaging for quantitative mapping of surgically resected breast tissues.

    abstract::The feasibility of spatial frequency domain imaging (SFDI) for breast surgical margin assessment was evaluated in tissue-simulating phantoms and in fully intact lumpectomy specimens at the time of surgery. Phantom data was evaluated according to contrast-detail resolution, quantitative accuracy and model-data goodness...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.036012

    authors: Laughney AM,Krishnaswamy V,Rice TB,Cuccia DJ,Barth RJ,Tromberg BJ,Paulsen KD,Pogue BW,Wells WA

    更新日期:2013-03-01 00:00:00

  • Confocal multispot microscope for fast and deep imaging in semicleared tissues.

    abstract::Although perfectly transparent specimens are imaged faster with light-sheet microscopy, less transparent samples are often imaged with two-photon microscopy leveraging its robustness to scattering; however, at the price of increased acquisition times. Clearing methods that are capable of rendering strongly scattering ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.2.020503

    authors: Adam MP,Müllenbroich MC,Di Giovanna AP,Alfieri D,Silvestri L,Sacconi L,Pavone FS

    更新日期:2018-02-01 00:00:00

  • Swept-source optical coherence tomography powered by a 1.3-μm vertical cavity surface emitting laser enables 2.3-mm-deep brain imaging in mice in vivo.

    abstract::We report noninvasive, in vivo optical imaging deep within a mouse brain by swept-source optical coherence tomography (SS-OCT), enabled by a 1.3-μm vertical cavity surface emitting laser (VCSEL). VCSEL SS-OCT offers a constant signal sensitivity of 105 dB throughout an entire depth of 4.25 mm in air, ensuring an exten...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.10.106004

    authors: Choi WJ,Wang RK

    更新日期:2015-10-01 00:00:00

  • Computer model to investigate the effect of eye movements on retinal heating during long-duration fixation on a laser source.

    abstract::A computer simulation called RHME (Retinal Heating in Moving Eye) is developed to simulate the heating pattern that occurs in the retina during a long-duration exposure to a continuous wave laser beam. The simulation takes into account eye movements that occur during a deliberate fixation. Due to the rapid (millisecon...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1783355

    authors: Lund BJ

    更新日期:2004-09-01 00:00:00

  • Effects of breast density and compression on normal breast tissue hemodynamics through breast tomosynthesis guided near-infrared spectral tomography.

    abstract::Optically derived tissue properties across a range of breast densities and the effects of breast compression on estimates of hemoglobin, oxygen metabolism, and water and lipid concentrations were obtained from a coregistered imaging system that integrates near-infrared spectral tomography (NIRST) with digital breast t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.9.091316

    authors: Michaelsen KE,Krishnaswamy V,Shi L,Vedantham S,Karellas A,Pogue BW,Paulsen KD,Poplack SP

    更新日期:2016-09-01 00:00:00

  • Effects of lipid composition on photothermal optical coherence tomography signals.

    abstract:SIGNIFICANCE:Photothermal optical coherence tomography (PT-OCT) has the promise to offer structural images coregistered with chemical composition information, which can offer a significant impact in early detection of diseases such as atherosclerosis. AIM:We take the first step in understanding the relation between PT...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.12.120501

    authors: Salimi M,Villiger M,Tabatabaei N

    更新日期:2020-12-01 00:00:00

  • Acousto-optic-tunable-filter-based spectropolarimetric imagers for medical diagnostic applications--instrument design point of view.

    abstract::Compact optical imagers that can detect both spectral and polarization signatures are required in many biomedical applications. An acousto-optic-tunable-filter (AOTF)-based imager is ideally suited to provide both agile spectral and polarization signatures. Such an imager can be readily used for real-time in vivo medi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2102507

    authors: Gupta N

    更新日期:2005-09-01 00:00:00

  • Shear wave elastography using amplitude-modulated acoustic radiation force and phase-sensitive optical coherence tomography.

    abstract::Investigating the elasticity of ocular tissue (cornea and intraocular lens) could help the understanding and management of pathologies related to biomechanical deficiency. In previous studies, we introduced a setup based on optical coherence tomography for shear wave elastography (SWE) with high resolution and high se...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.1.016001

    authors: Nguyen TM,Arnal B,Song S,Huang Z,Wang RK,O'Donnell M

    更新日期:2015-01-01 00:00:00

  • Analysis of red blood cell parameters by Talbot-projected fringes.

    abstract::Red blood cell (RBC) anomalies are significant symptoms for identification of health disorders and several blood diseases, which involve the modification of the parameters and biophysical characteristics of such cells. The aim of this study is to measure the three-dimensional phase information of healthy RBCs and thei...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.10.106009

    authors: Agarwal S,Kumar V,Shakher C

    更新日期:2017-10-01 00:00:00

  • Distinguishing tracheal and esophageal tissues with hyperspectral imaging and fiber-optic sensing.

    abstract::During emergency medical situations, where the patient has an obstructed airway or necessitates respiratory support, endotracheal intubation (ETI) is the medical technique of placing a tube into the trachea in order to facilitate adequate ventilation of the lungs. Complications during ETI, such as repeated attempts, f...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.11.117004

    authors: Nawn CD,Souhan BE,Carter R 3rd,Kneapler C,Fell N,Ye JY

    更新日期:2016-11-01 00:00:00

  • Rapid convergence to the inverse solution regularized with Lorentzian distributed function for near-infrared continuous wave diffuse optical tomography.

    abstract::A promising method to achieve rapid convergence for image reconstruction is introduced for the continuous-wave near-infrared (NIR) diffuse optical tomography (DOT). Tomographic techniques are usually implemented off line and are time consuming to realize image reconstruction, especially for NIR DOT. Therefore, it is e...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3299727

    authors: Pan MC,Pan MC

    更新日期:2010-01-01 00:00:00

  • Measurement of the refractive index of whole blood and its components for a continuous spectral region.

    abstract::The refractive index of blood is a key biophysical parameter, which can reflect the physiological state. We measured the refractive index of whole blood and other components, such as serum, plasma, and hemoglobin, based on internal reflection by using a homemade apparatus in the spectral range of 400 to 750 nm. In add...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.3.035003

    authors: Liu S,Deng Z,Li J,Wang J,Huang N,Cui R,Zhang Q,Mei J,Zhou W,Zhang C,Ye Q,Tian J

    更新日期:2019-03-01 00:00:00

  • Label-free optical activation of astrocyte in vivo.

    abstract::As the most abundant cell type in the central nervous system, astrocyte has been one of main research topics in neuroscience. Although various tools have been developed, at present, there is no tool that allows noninvasive activation of astrocyte in vivo without genetic or pharmacological perturbation. Here we report ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3600774

    authors: Choi M,Yoon J,Ku T,Choi K,Choi C

    更新日期:2011-07-01 00:00:00

  • Measurement of oxygen saturation in small retinal vessels with adaptive optics confocal scanning laser ophthalmoscope.

    abstract::We have used an adaptive optics confocal scanning laser ophthalmoscope to assess oxygen saturation in small retinal vessels. Images of the vessels with a diameter smaller than 50 μm are recorded at oxygen sensitive and isosbestic wavelengths (680 and 796 nm, respectively). The vessel optical densities (ODs) are determ...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3655354

    authors: Li H,Lu J,Shi G,Zhang Y

    更新日期:2011-11-01 00:00:00

  • Infrared spectroscopic analysis of human and bovine articular cartilage proteoglycans using carbohydrate peak or its second derivative.

    abstract::Fourier transform infrared (FTIR) microspectroscopy has been used to estimate the spatial proteoglycan (PG) and collagen contents in articular cartilage (AC). However, it is not clear whether the results of FTIR analyses are consistent between different species. Our aim was to clarify how three different FTIR PG param...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.9.097006

    authors: Rieppo L,Närhi T,Helminen HJ,Jurvelin JS,Saarakkala S,Rieppo J

    更新日期:2013-09-01 00:00:00

  • Photonic approach to the selective inactivation of viruses with a near-infrared subpicosecond fiber laser.

    abstract::We report a photonic approach for selective inactivation of viruses with a near-infrared subpicosecond laser. We demonstrate that this method can selectively inactivate viral particles ranging from nonpathogenic viruses such as the M13 bacteriophage and the tobacco mosaic virus to pathogenic viruses such as the human ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3275477

    authors: Tsen KT,Tsen SW,Fu Q,Lindsay SM,Kibler K,Jacobs B,Wu TC,Karanam B,Jagu S,Roden RB,Hung CF,Sankey OF,Ramakrishna B,Kiang JG

    更新日期:2009-11-01 00:00:00

  • Diagnosis of oral submucous fibrosis with optical coherence tomography.

    abstract::The epithelium (EP) thickness and the standard deviation (SD) of A-mode scan intensity in the laminar propria (LP) layer are used as effective indicators for the diagnosis of oral submucous fibrosis (OSF) based on the noninvasive clinical scanning of a swept-source optical coherence tomography (OCT) system of approxim...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3233653

    authors: Lee CK,Tsai MT,Lee HC,Chen HM,Chiang CP,Wang YM,Yang CC

    更新日期:2009-09-01 00:00:00

  • In vivo photoacoustic imaging of blood vessels using a homodyne interferometer with zero-crossing triggering.

    abstract::We demonstrate a quasinoncontact photoacoustic imaging method using a homodyne interferometer with a long coherence length laser. The generated photoacoustic signal is detected by a system that is locked at its maximum sensitivity through the use of balanced detection and zero-crossing triggering. The balanced detecto...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.3.036002

    authors: Lu J,Gao Y,Ma Z,Zhou H,Wang RK,Wang Y

    更新日期:2017-03-01 00:00:00

  • Development of single-channel optical video stereomicroscopy.

    abstract::This study introduces a single-channel optical video stereomicroscope based on a transparent rotating deflector (TRD) for high-resolution and high-magnification stereomicroscopy. The existing stereomicroscopes have some limitations, such as limited resolution and magnification, fixed optical channel, and the necessity...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.126001

    authors: Radfar E,Park J,Jung B

    更新日期:2016-12-01 00:00:00

  • Fast spatiotemporal image reconstruction based on low-rank matrix estimation for dynamic photoacoustic computed tomography.

    abstract::In order to monitor dynamic physiological events in near-real time, a variety of photoacoustic computed tomography (PACT) systems have been developed that can rapidly acquire data. Previously reported studies of dynamic PACT have employed conventional static methods to reconstruct a temporally ordered sequence of imag...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.5.056007

    authors: Wang K,Xia J,Li C,Wang LV,Anastasio MA

    更新日期:2014-05-01 00:00:00

  • Handheld projective imaging device for near-infrared fluorescence imaging and intraoperative guidance of sentinel lymph node resection.

    abstract::We propose a handheld projective imaging device for orthotopic projection of near-infrared fluorescence images onto target biological tissue at visible wavelengths without any additional visual aid. The device integrates a laser diode light source module, a camera module, a projector, an ultrasonic distance sensor, a ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.8.080503

    authors: Li C,Liu P,Shao P,Pei J,Li Y,Pawlik TM,Martin EW,Xu RX

    更新日期:2019-08-01 00:00:00

  • Resolution in the ApoTome and the confocal laser scanning microscope: comparison.

    abstract::The essential feature of the confocal laser scanning microscope (cLSM) is the generation of optical sections by the removal of out-of-focus light. About ten years ago, structured illumination microscopy (SIM) was introduced as an alternative method for obtaining optical sections from biological specimens. Here we comp...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3083439

    authors: Weigel A,Schild D,Zeug A

    更新日期:2009-01-01 00:00:00

  • Ocular optical aberrometer for clinical use.

    abstract::Higher-order optical errors of the human eye are often responsible for reduced visual acuity in spite of an optimal spherical or cylindrical refraction. These optical aberrations are of natural origin or can result from operations in the eye that involve optical structures. The ocular aberrometer presented is based on...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1344589

    authors: Mierdel P,Kaemmerer M,Mrochen M,Krinke HE,Seiler T

    更新日期:2001-04-01 00:00:00

  • Imaging performance of a miniature integrated microendoscope.

    abstract::An integrated miniature multi-modal microscope (4M device) for microendoscopy was built and tested. Imaging performance is evaluated and imaging results are presented for both fluorescence and reflectance samples. Images of biological samples show successful imaging of both thin layers of fixed cells prepared on a sli...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2978060

    authors: Rogers JD,Landau S,Tkaczyk TS,Descour MR,Rahman MS,Richards-Kortum R,Kärkäinen AH,Christenson T

    更新日期:2008-09-01 00:00:00

  • Noninvasive measurements of carotenoids in bovine udder by reflection spectroscopy.

    abstract::For a long time, the antioxidative status in cattle has been discussed as an indicator for stress conditions resulting from disease or exertion. Until now, invasive approaches have been necessary to obtain blood samples or biopsy materials and gain insights into the antioxidative status of cattle. Due to these efforts...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.10.101514

    authors: Klein J,Darvin ME,Müller KE,Lademann J

    更新日期:2012-10-01 00:00:00

  • Comparison of spectroscopically measured finger and forearm tissue ethanol concentration to blood and breath ethanol measurements.

    abstract::Previous works investigated a spectroscopic technique that offered a promising alternative to blood and breath assays for determining in vivo alcohol concentration. Although these prior works measured the dorsal forearm, we report the results of a 26-subject clinical study designed to evaluate the spectroscopic techni...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3535594

    authors: Ridder TD,Hull EL,Ver Steeg BJ,Laaksonen BD

    更新日期:2011-02-01 00:00:00

  • Tutorial on diffuse light transport.

    abstract::A tutorial introduction to diffuse light transport is presented. The basic analytic equations of time-resolved, steady-state and modulated light transport are introduced. The perturbation method for handling slight heterogeneities in optical properties is outlined. The treatment of boundary conditions such as an air/t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2967535

    authors: Jacques SL,Pogue BW

    更新日期:2008-07-01 00:00:00