Abstract:
:Compact optical imagers that can detect both spectral and polarization signatures are required in many biomedical applications. An acousto-optic-tunable-filter (AOTF)-based imager is ideally suited to provide both agile spectral and polarization signatures. Such an imager can be readily used for real-time in vivo medical diagnostic applications. We develop a family of small, robust, and programmable hyperspectral imagers operating from the ultraviolet (UV) to the long-wave IR (LWIR). Such imagers require minimal data processing because they can acquire images at only select wavelengths of interest. We use AOTFs made of KDP, TeO2, and TAS with Si-based CCD, InGaAs, InSb, and HgCdTe cameras to cover different spectral regions from the UV to the LWIR. Operation of each of these imagers and image acquisition is computer controlled. The most developed imager covers the visible to near-infrared (VNIR) region from 400 to 900 nm, with a 10-nm spectral resolution at 600 nm, it uses an electronically tunable TeO2 AOTF as a bandpass filter, and a nematic liquid crystal retarder to change polarization. We describe our concept in the development of these imagers and present new results obtained using the VNIR imager.
journal_name
J Biomed Optjournal_title
Journal of biomedical opticsauthors
Gupta Ndoi
10.1117/1.2102507subject
Has Abstractpub_date
2005-09-01 00:00:00pages
051802issue
5eissn
1083-3668issn
1560-2281journal_volume
10pub_type
杂志文章abstract::We instrumented a combined fluorescence spectroscopy and imaging system to characterize the single- and two-photon excited autofluorescence in epithelial tissue. Single-photon fluorescence (SPF) are compared with two-photon fluorescence (TPF) measured at the same location in epithelial tissue. It was found that the SP...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2975866
更新日期:2008-09-01 00:00:00
abstract::Several studies demonstrated that the cyclic adenosine monophosphate (cAMP), an important second messenger, is involved in the mechanism of low-level laser irradiation (LLLI) treatment. However, most of these studies obtained the cAMP level in cell culture extracts or supernatant. In this study, the cAMP level in livi...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.5.051029
更新日期:2015-05-01 00:00:00
abstract::Occlusal discoloration due to staining frequently occurs on the pits and fissures of teeth. Noncariogenic discoloration (non-CD) refers to the attachment of staining chromogens to sound surfaces, whereas cariogenic discoloration (CD) represents the discoloration of porous structures due to bacterial metabolites and mi...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.23.9.091402
更新日期:2018-03-01 00:00:00
abstract::We demonstrate a single-camera imaging system that can simultaneously acquire brightfield, darkfield, and phase contrast images in real time. Our method uses computational illumination via a programmable light-emitting diode (LED) array at the source plane, providing flexible patterning of illumination angles. Brightf...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.19.10.106002
更新日期:2014-01-01 00:00:00
abstract::A hyperspectral image projector (HIP) based on liquid crystal on silicon spatial light modulators is explained and demonstrated to generate data cubes. The HIP-constructed data cubes are three-dimensional images of the spatial distribution of spectrally resolved abundances of intracellular light-absorbing oxyhemoglobi...
journal_title:Journal of biomedical optics
pub_type: 杂志文章,收录出版
doi:10.1117/1.JBO.20.11.111215
更新日期:2015-01-01 00:00:00
abstract::We have developed a novel nitroimidazole indocyanine dye conjugate for tumor-targeted hypoxia fluorescence tomography. The hypoxia probe has been evaluated in vitro using tumor cell lines and in vivo with tumor targeting in mice. The in vitro cell studies were performed to assess fluorescence labeling differences betw...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3589348
更新日期:2011-06-01 00:00:00
abstract::A main field in biomedical optics research is diffuse optical tomography, where intensity variations of the transmitted light traversing through tissue are detected. Mathematical models and reconstruction algorithms based on finite element methods and Monte Carlo simulations describe the light transport inside the tis...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.17.12.126009
更新日期:2012-12-01 00:00:00
abstract::Ambulatory diffuse optical tomography (aDOT) is based on near-infrared spectroscopy (NIRS) and enables three-dimensional imaging of regional hemodynamics and oxygen consumption during a person’s normal activities. Although NIRS has been previously used for muscle assessment, it has been notably limited in terms of the...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.9.091314
更新日期:2016-09-01 00:00:00
abstract::Fluorescence lifetime imaging microscopy (FLIM) using multiphoton excitation techniques is now finding an important place in quantitative imaging of protein-protein interactions and intracellular physiology. Recent developments in multiphoton FLIM methods are reviewed and a novel multiphoton FLIM system using a streak...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1577574
更新日期:2003-07-01 00:00:00
abstract::We investigate optoelectronic properties of integrated structures comprising semiconductor light-emitting materials for optical probes of microscopic biological systems. Compound semiconductors are nearly ideal light emitters for probing cells and other microorganisms because of their spectral match to the transparenc...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1506931
更新日期:2002-10-01 00:00:00
abstract::We present a novel fluorescence imaging system developed for real-time interventional imaging applications. The system implements a correction scheme that improves the accuracy of epi-illumination fluorescence images for light intensity variation in tissues. The implementation is based on the use of three cameras oper...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3259362
更新日期:2009-11-01 00:00:00
abstract::Pulse-modulated second harmonic imaging microscopes (PM-SHIMs) exhibit improved signal-to-noise ratio (SNR) over conventional SHIMs on sensitive imaging and quantification of weak collagen signals inside tissues. We quantify the spatial distribution of sparse collagen inside a xenograft model of human acute myeloid le...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3497565
更新日期:2010-09-01 00:00:00
abstract::The capability of optical coherence tomography (OCT) to perform "optical biopsy" of tissues within a depth range of 1 to 2 mm with micron-scale resolution in real time makes it a promising biomedical imaging modality for dermatologic applications. Three high-speed, spectrometer-based frequency-domain OCT systems opera...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3400665
更新日期:2010-03-01 00:00:00
abstract::We compared light-induced fluorescence (LIF) to nominal injected drug dose for predicting the depth of necrosis response to photodynamic therapy (PDT) in a murine tumor model. Mice were implanted with radiation-induced fibrosarcoma (RIF) and were injected with 0, 5, or 10 mg/kg Photofrin. 630-nm light (30 J/cm(2), 75 ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1560011
更新日期:2003-04-01 00:00:00
abstract::The expensive fabrication of current opto-microfluidic sensors is a barrier to the successful adoption of these devices in point-of-care testing. This work reports a simple inexpensive opto-microfluidic device incorporating a poly(dimethylsiloxane)-glass hybrid microfluidic chip modified with gold nanoparticles and a ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.19.3.030504
更新日期:2014-03-01 00:00:00
abstract::By applying linear perturbation theory to the radiation transport equation, the inverse problem of optical diffusion tomography can be reduced to a set of linear equations, Wμ=R, where W is the weight function, μ are the cross-section perturbations to be imaged, and R is the detector readings perturbations. We have st...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.429870
更新日期:1998-04-01 00:00:00
abstract::Three-dimensional (3-D) tissue imaging offers substantial benefits to a wide range of biomedical investigations from cardiovascular biology, diabetes, Alzheimer's disease to cancer. Two-photon tissue cytometry is a novel technique based on high-speed multiphoton microscopy coupled with automated histological sectionin...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2435626
更新日期:2007-01-01 00:00:00
abstract::Functional near-infrared spectroscopy is prone to contamination by motion artifacts (MAs). Motion correction algorithms have previously been proposed and their respective performance compared for evoked rain activation studies. We study instead the effect of MAs on "oscillation" data which is at the basis of functiona...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.5.056011
更新日期:2015-05-01 00:00:00
abstract::Quantitative microscopy has been extensively used in biomedical research and has provided significant insights into structure and dynamics at the cell and tissue level. The entire procedure of quantitative microscopy is comprised of specimen preparation, light absorption/reflection/emission from the specimen, microsco...
journal_title:Journal of biomedical optics
pub_type: 杂志文章,评审
doi:10.1117/1.1779233
更新日期:2004-09-01 00:00:00
abstract::We demonstrate dynamic in vivo imaging using a low-cost portable pulsed laser diode (PLD)-based photoacoustic tomography system. The system takes advantage of an 803-nm PLD having high-repetition rate ∼7000 Hz combined with a fast-scanning single-element ultrasound transducer leading to a 5 s cross-sectional imaging....
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.22.9.090501
更新日期:2017-09-01 00:00:00
abstract::Using single-molecule microscopy, we present a method to quantify the number of single autofluorescent proteins when they cannot be optically resolved. This method relies on the measurement of the total intensity emitted by each aggregate until it photobleaches. This strategy overcomes the inherent problem of blinking...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2940600
更新日期:2008-05-01 00:00:00
abstract::The objective of this work was to compare the accuracy of analyte concentration estimation when using transmission versus diffuse reflectance spectroscopy of a scattering medium. Monte Carlo ray tracing of light through the medium was used in conjunction with pure component absorption spectra and Beer-Lambert absorpti...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.23.1.018001
更新日期:2018-01-01 00:00:00
abstract::We report that the pathologic components present within the atheromatous plaques of ApoE knock-out mice can reflect significant amounts of mid-infrared (mid-IR) light. Furthermore, the reflected light spectra contained the unique signatures of a variety of biologic features including those found in unstable or "vulner...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2937469
更新日期:2008-05-01 00:00:00
abstract::In the last decade, coherent anti-Stokes Raman scattering (CARS) microscopy has emerged as a powerful multiphoton imaging technique offering label-free chemical sensitivity and high three-dimensional resolution. However, its widespread application in the life sciences has been hampered by the use of costly pulsed lase...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.6.066004
更新日期:2013-06-01 00:00:00
abstract::We combine laser tweezers with custom computer tracking software and robotics to analyze the motility [swimming speed, VCL (curvilinear velocity), and swimming force in terms of escape laser power (Pesc)] and energetics [mitochondrial membrane potential (MP)] of individual sperm. Domestic dog sperm are labeled with a ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2839051
更新日期:2008-01-01 00:00:00
abstract::Photodynamic therapy (PDT) is reviewed using the treatment of skin tumors as an example of superficial lesions and prostate cancer as an example of deep-lying lesions requiring interstitial intervention. These two applications are among the most commonly studied in oncological PDT, and illustrate well the different ch...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3466579
更新日期:2010-07-01 00:00:00
abstract::Fourier transform infrared (FTIR) microspectroscopy has been used to estimate the spatial proteoglycan (PG) and collagen contents in articular cartilage (AC). However, it is not clear whether the results of FTIR analyses are consistent between different species. Our aim was to clarify how three different FTIR PG param...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.9.097006
更新日期:2013-09-01 00:00:00
abstract::We propose an offset-sparsity decomposition method for the enhancement of a color microscopic image of a stained specimen. The method decomposes vectorized spectral images into offset terms and sparse terms. A sparse term represents an enhanced image, and an offset term represents a "shadow." The related optimization ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.7.076012
更新日期:2015-07-01 00:00:00
abstract::Photoacoustic imaging has become an emerging tool for theranostic applications. Not only does it help in journal_title:Journal of biomedical optics pub_type: 杂志文章 doi:10.1117/1.JBO.22.4.041007 更新日期:2017-04-01 00:00:00
abstract::Artificially created demineralized and remineralized carious lesions on the root and enamel of human teeth were examined by photothermal radiometry (PTR) and modulated luminescence (LUM). Fourteen extracted human teeth were used and a lesion was created on a 1 mmx4 mm rectangular window, spanning root to enamel, using...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2942374
更新日期:2008-05-01 00:00:00