Super-resolution photoacoustic microscopy using photonic nanojets: a simulation study.

Abstract:

:Optical resolution photoacoustic microscopy (ORPAM) is important for various biomedical applications, such as the study of cellular structures, microcirculation systems, and tumor angiogenesis. However, the lateral resolution of a conventional ORPAM is limited by optical diffraction. In this work, we report a simulation study to achieve subdiffraction-limited super-resolution in ORPAM using microspheres. Laser radiation is focused through a microsphere to generate a photonic nanojet, which provides the possibility to break the diffraction limit in ORPAM by reducing the size of the excitation volume. In our simulations using microspheres, we observed improvement in the lateral resolution up to compared to conventional ORPAM. The method is simple, cost effective, and can provide far-field resolution. This approach may provide new opportunities for many biomedical imaging applications that require finer resolution.

journal_name

J Biomed Opt

authors

Upputuri PK,Wen ZB,Wu Z,Pramanik M

doi

10.1117/1.JBO.19.11.116003

subject

Has Abstract

pub_date

2014-01-01 00:00:00

pages

116003

issue

11

eissn

1083-3668

issn

1560-2281

pii

1926222

journal_volume

19

pub_type

杂志文章
  • Analysis of the change in peak corneal temperature during excimer laser ablation in porcine eyes.

    abstract::The objective is to characterize the impact of different ablation parameters on the thermal load during corneal refractive surgery by means of excimer laser ablation on porcine eyes. One hundred eleven ablations were performed in 105 porcine eyes. Each ablation was recorded using infrared thermography and analyzed mai...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.7.078001

    authors: Arba Mosquera S,Verma S

    更新日期:2015-07-01 00:00:00

  • In vivo simultaneous multispectral fluorescence imaging with spectral multiplexed volume holographic imaging system.

    abstract::A simultaneous multispectral fluorescence imaging system incorporating multiplexed volume holographic grating (VHG) is developed to acquire multispectral images of an object in one shot. With the multiplexed VHG, the imaging system can provide the distribution and spectral characteristics of multiple fluorophores in t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.6.060502

    authors: Lv Y,Zhang J,Zhang D,Cai W,Chen N,Luo J

    更新日期:2016-06-01 00:00:00

  • In vivo assessment and evaluation of lung tissue morphologic and physiological changes from non-contact endoscopic reflectance spectroscopy for improving lung cancer detection.

    abstract::We present a method for lung cancer detection exploiting reflectance spectra measured in vivo during endoscopic imaging of the lung. The measured reflectance spectra were analyzed using a specially developed light-transport model to obtain quantitative information about cancer-related, physiological, and morphologic c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2337529

    authors: Fawzy YS,Petek M,Tercelj M,Zeng H

    更新日期:2006-07-01 00:00:00

  • Depth-correction algorithm that improves optical quantification of large breast lesions imaged by diffuse optical tomography.

    abstract::Optical quantification of large lesions imaged with diffuse optical tomography in reflection geometry is depth dependence due to the exponential decay of photon density waves. We introduce a depth-correction method that incorporates the target depth information provided by coregistered ultrasound. It is based on balan...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3573814

    authors: Tavakoli B,Zhu Q

    更新日期:2011-05-01 00:00:00

  • System analysis of spatial frequency domain imaging for quantitative mapping of surgically resected breast tissues.

    abstract::The feasibility of spatial frequency domain imaging (SFDI) for breast surgical margin assessment was evaluated in tissue-simulating phantoms and in fully intact lumpectomy specimens at the time of surgery. Phantom data was evaluated according to contrast-detail resolution, quantitative accuracy and model-data goodness...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.036012

    authors: Laughney AM,Krishnaswamy V,Rice TB,Cuccia DJ,Barth RJ,Tromberg BJ,Paulsen KD,Pogue BW,Wells WA

    更新日期:2013-03-01 00:00:00

  • Rise of Raman spectroscopy in neurosurgery: a review.

    abstract:SIGNIFICANCE:Although the clinical potential for Raman spectroscopy (RS) has been anticipated for decades, it has only recently been used in neurosurgery. Still, few devices have succeeded in making their way into the operating room. With recent technological advancements, however, vibrational sensing is poised to be a...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.5.050901

    authors: DePaoli D,Lemoine É,Ember K,Parent M,Prud'homme M,Cantin L,Petrecca K,Leblond F,Côté DC

    更新日期:2020-05-01 00:00:00

  • Automatic detection of foreign objects in computed radiography.

    abstract::This paper presents an effective two-step scheme for automatic object detection in computed radiography (CR) images. First, various structure elements of the morphological filters, designed by incorporating available morphological features of the objects of interest including their sizes and rough shape descriptions, ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1289771

    authors: Xuan J,Adali T,Wang Y,Siegel E

    更新日期:2000-10-01 00:00:00

  • simEye: Computer-based simulation of visual perception under various eye defects using Zernike polynomials.

    abstract::We describe a computer eye model that allows for aspheric surfaces and a three-dimensional computer-based ray-tracing technique to simulate optical properties of the human eye and visual perception under various eye defects. Eye surfaces, such as the cornea, eye lens, and retina, are modeled or approximated by a set o...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2357734

    authors: Fink W,Micol D

    更新日期:2006-09-01 00:00:00

  • Quantitative mapping of collagen fiber alignment in thick tissue samples using transmission polarized-light microscopy.

    abstract::Immersion optical clearing makes it possible to use transmission polarized-light microscopy for characterization of thick (200 to 2000  μm) layers of biological tissues. We discuss polarization properties of thick samples in the context of the problem of characterization of collagen fiber alignment in connective tissu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.7.071111

    authors: Yakovlev DD,Shvachkina ME,Sherman MM,Spivak AV,Pravdin AB,Yakovlev DA

    更新日期:2016-07-01 00:00:00

  • Photoacoustic properties of anterior ocular tissues.

    abstract::Clinical imaging techniques for the anterior segment of the eye provide excellent anatomical information, but molecular imaging techniques are lacking. Molecular photoacoustic imaging is one option to address this need, but implementation requires use of contrast agents to distinguish molecular targets from background...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.5.056004

    authors: Kubelick KP,Snider EJ,Ethier CR,Emelianov S

    更新日期:2019-05-01 00:00:00

  • Test-retest reliability of the prefrontal response to affective pictures based on functional near-infrared spectroscopy.

    abstract::Functional near-infrared spectroscopy (fNIRS) is being increasingly applied to affective and social neuroscience research; however, the reliability of this method is still unclear. This study aimed to evaluate the test–retest reliability of the fNIRS-based prefrontal response to emotional stimuli. Twenty-six participa...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.1.016011

    authors: Huang Y,Mao M,Zhang Z,Zhou H,Zhao Y,Duan L,Kreplin U,Xiao X,Zhu C

    更新日期:2017-01-01 00:00:00

  • Diagnostic performance of receptor-specific surgical specimen staining correlates with receptor expression level.

    abstract::Intraoperative margin assessment is imperative to cancer cure but is a continued challenge to successful surgery. Breast conserving surgery is a relevant example, where a cosmetically improved outcome is gained over mastectomy, but re-excision is required in >25  %   of cases due to positive or closely involved margin...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.2.026002

    authors: Schaefer JM,Barth CW,Davis SC,Gibbs SL

    更新日期:2019-02-01 00:00:00

  • Raman microscopy in the diagnosis and prognosis of surgically resected nonsmall cell lung cancer.

    abstract::The main curative therapy for patients with nonsmall cell lung cancer is surgery. Despite this, the survival rate is only 50%, therefore it is important to more efficiently diagnose and predict prognosis for lung cancer patients. Raman spectroscopy is useful in the diagnosis of malignant and premalignant lesions. The ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3323088

    authors: Magee ND,Beattie JR,Carland C,Davis R,McManus K,Bradbury I,Fennell DA,Hamilton PW,Ennis M,McGarvey JJ,Elborn JS

    更新日期:2010-03-01 00:00:00

  • Three-dimensional optical method for integrated visualization of mouse islet microstructure and vascular network with subcellular-level resolution.

    abstract::Microscopic visualization of islets of Langerhans under normal and diabetic conditions is essential for understanding the pathophysiology of the disease. The intrinsic opacity of pancreata, however, limits optical accessibility for high-resolution light microscopy of islets in situ. Because the standard microtome-base...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3470241

    authors: Fu YY,Lu CH,Lin CW,Juang JH,Enikolopov G,Sibley E,Chiang AS,Tang SC

    更新日期:2010-07-01 00:00:00

  • Functional assessment of gap junctions in monolayer and three-dimensional cultures of human tendon cells using fluorescence recovery after photobleaching.

    abstract::Gap junction-mediated intercellular communication influences a variety of cellular activities. In tendons, gap junctions modulate collagen production, are involved in strain-induced cell death, and are involved in the response to mechanical stimulation. The aim of the present study was to investigate gap junction-medi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.1.015001

    authors: Kuzma-Kuzniarska M,Yapp C,Pearson-Jones TW,Jones AK,Hulley PA

    更新日期:2014-01-01 00:00:00

  • Noninvasive measurements of carotenoids in bovine udder by reflection spectroscopy.

    abstract::For a long time, the antioxidative status in cattle has been discussed as an indicator for stress conditions resulting from disease or exertion. Until now, invasive approaches have been necessary to obtain blood samples or biopsy materials and gain insights into the antioxidative status of cattle. Due to these efforts...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.10.101514

    authors: Klein J,Darvin ME,Müller KE,Lademann J

    更新日期:2012-10-01 00:00:00

  • Dynamics of retinal photocoagulation and rupture.

    abstract::In laser retinal photocoagulation, short (<20 ms) pulses have been found to reduce thermal damage to the inner retina, decrease treatment time, and minimize pain. However, the safe therapeutic window (defined as the ratio of power for producing a rupture to that of mild coagulation) decreases with shorter exposures. T...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3130282

    authors: Sramek C,Paulus Y,Nomoto H,Huie P,Brown J,Palanker D

    更新日期:2009-05-01 00:00:00

  • Delineation of an oral cancer lesion with swept-source optical coherence tomography.

    abstract::We demonstrate the ex vivo imaging of an oral cancerous sample with a swept-source optical coherence tomography (SS-OCT) system. With the axial resolution of 8 microm in free space and system sensitivity of 108 dB, we can well distinguish the normal and abnormal tissue portions in a sample. In particular, we analyze t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2960632

    authors: Tsai MT,Lee HC,Lu CW,Wang YM,Lee CK,Yang CC,Chiang CP

    更新日期:2008-07-01 00:00:00

  • Optical fiber probe spectroscopy for laparoscopic monitoring of tissue oxygenation during esophagectomies.

    abstract::Anastomotic complication is a major morbidity associated with esophagectomy. Gastric ischemia after conduit creation contributes to anastomotic complications, but a reliable method to assess oxygenation in the gastric conduit is lacking. We hypothesize that fiber optic spectroscopy can reliably assess conduit oxygenat...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3512149

    authors: Gareau DS,Truffer F,Perry KA,Pham TH,Enestvedt CK,Dolan JP,Hunter JG,Jacques SL

    更新日期:2010-11-01 00:00:00

  • Spatial distribution of vastus lateralis blood flow and oxyhemoglobin saturation measured at the end of isometric quadriceps contraction by multichannel near-infrared spectroscopy.

    abstract::Muscle blood flow (MBF) and muscle oxygen saturation (SmO(2)) were measured at eight locations (four proximal, four distal) over a 4 x 8 cm(2) area of the vastus lateralis at rest and immediately after isometric, maximal quadriceps contraction using multichannel, frequency-domain, near-infrared spectroscopy. A venous ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1646417

    authors: Quaresima V,Ferrari M,Franceschini MA,Hoimes ML,Fantini S

    更新日期:2004-03-01 00:00:00

  • Photon migration through fetal head in utero using continuous wave, near-infrared spectroscopy: development and evaluation of experimental and numerical models.

    abstract::In this work experimental tissue phantoms and numerical models were developed to estimate photon migration through the fetal head in utero. The tissue phantoms incorporate a fetal head within an amniotic fluid sac surrounded by a maternal tissue layer. A continuous wave, dual-wavelength (lambda = 760 and 850 nm) spect...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429983

    authors: Vishnoi G,Hielscher AH,Ramanujam N,Chance B

    更新日期:2000-04-01 00:00:00

  • Label-free separation of human embryonic stem cells and their differentiating progenies by phasor fluorescence lifetime microscopy.

    abstract::We develop a label-free optical technique to image and discriminate undifferentiated human embryonic stem cells (hESCs) from their differentiating progenies in vitro. Using intrinsic cellular fluorophores, we perform fluorescence lifetime microscopy (FLIM) and phasor analysis to obtain hESC metabolic signatures. We id...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.4.046012

    authors: Stringari C,Sierra R,Donovan PJ,Gratton E

    更新日期:2012-04-01 00:00:00

  • Combined ultrasound and photoacoustic imaging to detect and stage deep vein thrombosis: phantom and ex vivo studies.

    abstract::Treatment of deep venous thrombosis (DVT)--a primary cause of potentially fatal pulmonary embolism (PE)--depends on the age of the thrombus. The existing clinical imaging methods are capable of visualizing a thrombus but cannot determine the age of the blood clot. Therefore, there is a need for an imaging technique to...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2992175

    authors: Karpiouk AB,Aglyamov SR,Mallidi S,Shah J,Scott WG,Rubin JM,Emelianov SY

    更新日期:2008-09-01 00:00:00

  • Needle-based fluorescence endomicroscopy via structured illumination with a plastic, achromatic objective.

    abstract::In order to diagnose cancer, a sample must be removed, prepared, and examined under a microscope, which is expensive, invasive, and time consuming. Fiber optic fluorescence endomicroscopy, where an image guide is used to obtain high-resolution images of tissue in vivo, has shown promise as an alternative to convention...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.9.096003

    authors: Kyrish M,Dobbs J,Jain S,Wang X,Yu D,Richards-Kortum R,Tkaczyk TS

    更新日期:2013-09-01 00:00:00

  • Noninvasive measurement of glucose concentration on human fingertip by optical coherence tomography.

    abstract::A method is proposed for determining the glucose concentration on the human fingertip by extracting two optical parameters, namely the optical rotation angle and the depolarization index, using a Mueller optical coherence tomography technique and a genetic algorithm. The feasibility of the proposed method is demonstra...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.4.047001

    authors: Chen TL,Lo YL,Liao CC,Phan QH

    更新日期:2018-04-01 00:00:00

  • In vivo label-free quantification of liver microcirculation using dual-modality microscopy.

    abstract::Microcirculation lesion is a common symptom of chronic liver diseases in the form of vasculature deformation and circulation alteration. In acute to chronic liver diseases such as biliary atresia, microcirculation lesion can have an early onset. Detection of microcirculation lesion is meaningful for studying the progr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.116006

    authors: Yan J,Kang Y,Xu S,Ong LL,Zhuo S,Bunte RM,Chen N,Asada HH,So PT,Wanless IR,Yu H

    更新日期:2014-01-01 00:00:00

  • Comparison of motion correction techniques applied to functional near-infrared spectroscopy data from children (Erratum).

    abstract::The erratum concerns amendment of Section 2.5 of the published article. ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,已发布勘误

    doi:10.1117/1.JBO.25.5.059801

    authors: Hu XS,Arredondo MM,Gomba M,Confer N,DaSilva AF,Johnson TD,Shalinsky M,Kovelman I

    更新日期:2020-05-01 00:00:00

  • Curved array photoacoustic tomographic system for small animal imaging.

    abstract::We present systematic characterization of a photoacoustic imaging system optimized for rapid, high-resolution tomographic imaging of small animals. The system is based on a 128-element ultrasonic transducer array with a 5-MHz center frequency and 80% bandwidth shaped to a quarter circle of 25 mm radius. A 16-channel d...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2907157

    authors: Gamelin J,Aguirre A,Maurudis A,Huang F,Castillo D,Wang LV,Zhu Q

    更新日期:2008-03-01 00:00:00

  • Robust single-molecule approach for counting autofluorescent proteins.

    abstract::Using single-molecule microscopy, we present a method to quantify the number of single autofluorescent proteins when they cannot be optically resolved. This method relies on the measurement of the total intensity emitted by each aggregate until it photobleaches. This strategy overcomes the inherent problem of blinking...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2940600

    authors: Cognet L,Tardin C,Négrier ML,Breillat C,Coussen F,Choquet D,Lounis B

    更新日期:2008-05-01 00:00:00

  • Toward the clinical application of time-domain fluorescence lifetime imaging.

    abstract::High-speed (video-rate) fluorescence lifetime imaging (FLIM) through a flexible endoscope is reported based on gated optical image intensifier technology. The optimization and potential application of FLIM to tissue autofluorescence for clinical applications are discussed. ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2102807

    authors: Munro I,McGinty J,Galletly N,Requejo-Isidro J,Lanigan PM,Elson DS,Dunsby C,Neil MA,Lever MJ,Stamp GW,French PM

    更新日期:2005-09-01 00:00:00