Three-dimensional optical method for integrated visualization of mouse islet microstructure and vascular network with subcellular-level resolution.

Abstract:

:Microscopic visualization of islets of Langerhans under normal and diabetic conditions is essential for understanding the pathophysiology of the disease. The intrinsic opacity of pancreata, however, limits optical accessibility for high-resolution light microscopy of islets in situ. Because the standard microtome-based, 2-D tissue analysis confines visualization of the islet architecture at a specific cut plane, 3-D representation of image data is preferable for islet assessment. We applied optical clearing to minimize the random light scattering in the mouse pancreatic tissue. The optical-cleared pancreas allowed penetrative, 3-D microscopic imaging of the islet microstructure and vasculature. Specifically, the islet vasculature was revealed by vessel painting-lipophilic dye labeling of blood vessels-for confocal microscopy. The voxel-based confocal micrographs were digitally processed with projection algorithms for 3-D visualization. Unlike the microtome-based tissue imaging, this optical method for penetrative imaging of mouse islets yielded clear, continuous optical sections for an integrated visualization of the islet microstructure and vasculature with subcellular-level resolution. We thus provide a useful imaging approach to change our conventional planar view of the islet structure into a 3-D panorama for better understanding of the islet physiology.

journal_name

J Biomed Opt

authors

Fu YY,Lu CH,Lin CW,Juang JH,Enikolopov G,Sibley E,Chiang AS,Tang SC

doi

10.1117/1.3470241

subject

Has Abstract

pub_date

2010-07-01 00:00:00

pages

046018

issue

4

eissn

1083-3668

issn

1560-2281

journal_volume

15

pub_type

杂志文章
  • Hybrid method for fast Monte Carlo simulation of diffuse reflectance from a multilayered tissue model with tumor-like heterogeneities.

    abstract::We present a hybrid method that combines a multilayered scaling method and a perturbation method to speed up the Monte Carlo simulation of diffuse reflectance from a multilayered tissue model with finite-size tumor-like heterogeneities. The proposed method consists of two steps. In the first step, a set of photon traj...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.1.010501

    authors: Zhu C,Liu Q

    更新日期:2012-01-01 00:00:00

  • Surgical lighting with contrast enhancement based on spectral reflectance comparison and entropy analysis.

    abstract::Surgical light is important for helping the surgeon easily identify specific tissues during an operation. We propose a spectral reflectance comparison model to optimize the light-emitting diode light spectrum in the operating room. An entropy evaluation method, meant specifically for surgical situations, was developed...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.10.105012

    authors: Shen J,Wang H,Wu Y,Li A,Chen C,Zheng Z

    更新日期:2015-10-01 00:00:00

  • Volumetric full-range magnetomotive optical coherence tomography.

    abstract::Magnetomotive optical coherence tomography (MM-OCT) can be utilized to spatially localize the presence of magnetic particles within tissues or organs. These magnetic particle-containing regions are detected by using the capability of OCT to measure small-scale displacements induced by the activation of an external ele...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.12.126001

    authors: Ahmad A,Kim J,Shemonski ND,Marjanovic M,Boppart SA

    更新日期:2014-12-01 00:00:00

  • Depth-sensitive reflectance measurements using obliquely oriented fiber probes.

    abstract::Computer simulation is used to facilitate the design of fiber-probe geometries that enable enhanced detection of optical signals arising from specific tissue depths. Obtaining understanding of the relationship between fiber-probe design and tissue interrogation is critical when developing strategies for optical detect...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1989335

    authors: Wang AM,Bender JE,Pfefer J,Utzinger U,Drezek RA

    更新日期:2005-07-01 00:00:00

  • Differential optical spectropolarimetric imaging system assisted by liquid crystal devices for skin imaging.

    abstract::Skin cancer diagnosis depends not only on histopathological examination but also on visual inspection before and after the excision of suspected lesion. Neoplasm is accompanied with changes in birefringence of collagen, pleomorphicity, and hyperchromatic state of epithelial nuclei. These phenomena can be measured by s...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3609003

    authors: Aharon O,Abdulhalim I,Arnon O,Rosenberg L,Dyomin V,Silberstein E

    更新日期:2011-08-01 00:00:00

  • Analysis of the dispersion compensation of acousto-optic deflectors used for multiphoton imaging.

    abstract::The acousto-optic deflector (AOD) is highly preferred in laser scanning microscopy for its fast scanning ability and random-addressing capability. However, its application in two-photon microscopy is frustrated by the dispersion of the AOD, which results in beam distortion and pulse lengthening. We report the analysis...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714061

    authors: Zeng S,Lv X,Bi K,Zhan C,Li D,Chen WR,Xiong W,Jacques SL,Luo Q

    更新日期:2007-03-01 00:00:00

  • Rab4 and Rab11 coordinately regulate the recycling of angiotensin II type I receptor as demonstrated by fluorescence resonance energy transfer microscopy.

    abstract::The recycling of G-protein-coupled receptors (GPCR) to the cell surface after internalization plays an important role in the regulation of overall GPCR activity. The angiotensin II type I receptor (AT1R) belongs to class B GPCRs that recycle slowly back to the cell surface. Previous studies have proposed that Rab11 co...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2943286

    authors: Li H,Li HF,Felder RA,Periasamy A,Jose PA

    更新日期:2008-05-01 00:00:00

  • Parameters affecting ultrafast laser microsurgery of subepithelial voids for scar treatment in vocal folds.

    abstract::Toward developing a new method for restoring tissue viscoelasticity in scarred vocal folds, we previously proposed a method to localize biomaterials within subepithelial voids ablated using ultrafast laser pulses. The clinical implementation of this method necessitates the quantification of the laser parameters for ab...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.11.118001

    authors: Yildirim M,Ferhanoglu O,Kobler J,Zeitels SM,Ben-Yakar A

    更新日期:2013-11-01 00:00:00

  • Analysis of optically anisotropic properties of biological tissues under stretching based on differential Mueller matrix formalism.

    abstract::The optical properties of biological tissues under stretching are investigated using a full-field ellipsometry technique based on a differential Mueller matrix formalism. Traditional photoelastic-based formalism for extracting the linear birefringence (LB) properties of stretched anisotropic optical samples ignores th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.3.035006

    authors: Chen HW,Huang CL,Lo YL,Chang YR

    更新日期:2017-03-01 00:00:00

  • Optical tweezers study of red blood cell aggregation and disaggregation in plasma and protein solutions.

    abstract::Kinetics of optical tweezers (OT)-induced spontaneous aggregation and disaggregation of red blood cells (RBCs) were studied at the level of cell doublets to assess RBC interaction mechanics. Measurements were performed under in vitro conditions in plasma and fibrinogen and fibrinogen + albumin solutions. The RBC spont...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.3.035001

    authors: Lee K,Kinnunen M,Khokhlova MD,Lyubin EV,Priezzhev AV,Meglinski I,Fedyanin AA

    更新日期:2016-03-01 00:00:00

  • Quantitative photoacoustic imaging: correcting for heterogeneous light fluence distributions using diffuse optical tomography.

    abstract::The specificity of molecular and functional photoacoustic (PA) images depends on the accuracy of the photoacoustic absorption spectroscopy. The PA signal is proportional to the product of the optical absorption coefficient and local light fluence; quantitative PA measurements of the optical absorption coefficient ther...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3626212

    authors: Bauer AQ,Nothdurft RE,Erpelding TN,Wang LV,Culver JP

    更新日期:2011-09-01 00:00:00

  • Pulse-modulated second harmonic imaging microscope quantitatively demonstrates marked increase of collagen in tumor after chemotherapy.

    abstract::Pulse-modulated second harmonic imaging microscopes (PM-SHIMs) exhibit improved signal-to-noise ratio (SNR) over conventional SHIMs on sensitive imaging and quantification of weak collagen signals inside tissues. We quantify the spatial distribution of sparse collagen inside a xenograft model of human acute myeloid le...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3497565

    authors: Raja AM,Xu S,Sun W,Zhou J,Tai DC,Chen CS,Rajapakse JC,So PT,Yu H

    更新日期:2010-09-01 00:00:00

  • Vector extrapolation methods for accelerating iterative reconstruction methods in limited-data photoacoustic tomography.

    abstract::As limited data photoacoustic tomographic image reconstruction problem is known to be ill-posed, the iterative reconstruction methods were proven to be effective in terms of providing good quality initial pressure distribution. Often, these iterative methods require a large number of iterations to converge to a soluti...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.7.071204

    authors: Awasthi N,Kalva SK,Pramanik M,Yalavarthy PK

    更新日期:2018-02-01 00:00:00

  • Machine learning approach for rapid and accurate estimation of optical properties using spatial frequency domain imaging.

    abstract::Fast estimation of optical properties from reflectance measurements at two spatial frequencies could pave way for real-time, wide-field and quantitative mapping of vital signs of tissues. We present a machine learning-based approach for estimating optical properties in the spatial frequency domain, where a random fore...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.7.071606

    authors: Panigrahi S,Gioux S

    更新日期:2018-12-01 00:00:00

  • Optical redox imaging indices discriminate human breast cancer from normal tissues.

    abstract::Our long-term goal was to investigate the potential of incorporating redox imaging technique as a breast cancer (BC) diagnosis component to increase the positive predictive value of suspicious imaging finding and to reduce unnecessary biopsies and overdiagnosis. We previously found that precancer and cancer tissues in...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.11.114003

    authors: Xu HN,Tchou J,Feng M,Zhao H,Li LZ

    更新日期:2016-11-01 00:00:00

  • Real-time microscopic visualization of tissue response to laser thermal therapy.

    abstract::We present methods for visualizing the dynamic response of biological samples to laser-induced heating. Our approach utilizes optical frequency-domain imaging to detect, spatially localize, and monitor unique dynamic signatures that arise within zones of active tissue denaturation. Since this information is precisely ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714027

    authors: Vakoc BJ,Tearney GJ,Bouma BE

    更新日期:2007-03-01 00:00:00

  • Fluorescence confocal endomicroscopy of the cervix: pilot study on the potential and limitations for clinical implementation.

    abstract::Current diagnostic capabilities and limitations of fluorescence endomicroscopy in the cervix are assessed by qualitative and quantitative image analysis. Four cervical tissue types are investigated: normal columnar epithelium, normal and precancerous squamous epithelium, and stromal tissue. This study focuses on the p...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.126011

    authors: Schlosser C,Bodenschatz N,Lam S,Lee M,McAlpine JN,Miller DM,Van Niekerk DJ,Follen M,Guillaud M,MacAulay CE,Lane PM

    更新日期:2016-12-01 00:00:00

  • Antibody-based magnetic nanoparticle immunoassay for quantification of Alzheimer's disease pathogenic factor.

    abstract::Alzheimer's disease (AD) is a neurodegenerative disorder that leads to a decline in cognitive and intellectual abilities and an irreversible mental deterioration. Based on multidisciplinary AD research, the most universally accepted hypotheses on AD pathogenesis are the intracerebral aggregate formation of beta-amyloi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.5.051205

    authors: Kim CB,Choi YY,Song WK,Song KB

    更新日期:2014-05-01 00:00:00

  • simEye: Computer-based simulation of visual perception under various eye defects using Zernike polynomials.

    abstract::We describe a computer eye model that allows for aspheric surfaces and a three-dimensional computer-based ray-tracing technique to simulate optical properties of the human eye and visual perception under various eye defects. Eye surfaces, such as the cornea, eye lens, and retina, are modeled or approximated by a set o...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2357734

    authors: Fink W,Micol D

    更新日期:2006-09-01 00:00:00

  • Review of clinical approaches in fluorescence lifetime imaging ophthalmoscopy.

    abstract::Autofluorescence-based imaging techniques have become very important in the ophthalmological field. Being noninvasive and very sensitive, they are broadly used in clinical routines. Conventional autofluorescence intensity imaging is largely influenced by the strong fluorescence of lipofuscin, a fluorophore that can be...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.23.9.091415

    authors: Sauer L,Andersen KM,Dysli C,Zinkernagel MS,Bernstein PS,Hammer M

    更新日期:2018-09-01 00:00:00

  • Molecular imaging of epidermal growth factor receptor in live cells with refractive index sensitivity using dark-field microspectroscopy and immunotargeted nanoparticles.

    abstract::We present a study using plasmonic nanoparticles (NPs) to image epidermal growth factor receptor (EGFR) in live cells. Through detailed analysis of the NP scattering spectra, we determine the intracellular refractive index (RI) within attoliter volumes inside of the living cells. Molecular imaging is demonstrated usin...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2837450

    authors: Curry AC,Crow M,Wax A

    更新日期:2008-01-01 00:00:00

  • Noninvasive monitoring of hemodynamic stress using quantitative near-infrared frequency-domain photon migration spectroscopy.

    abstract::Hemorrhagic hypovolemia and inotropic agent administration were used to manipulate cardiac output (CO) and oxygen delivery in rabbits to investigate the correlation between noninvasive frequency domain photon migration (FDPM) spectroscopy and invasive hemodynamic monitoring parameters. Frequency-domain photon migratio...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1427046

    authors: Pham TH,Hornung R,Ha HP,Burney T,Serna D,Powell L,Brenner M,Tromberg BJ

    更新日期:2002-01-01 00:00:00

  • Modulation transfer function measurement of scanning reflectance microscopes.

    abstract::Real-time medical imaging systems such as reflectance confocal microscopes and optical coherence microscopes are being tested in multiple-patient and multiple-center clinical trials. The modulation transfer function (MTF) of these systems at any given time influences the image information content and can affect the in...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2779352

    authors: Wang Z,Glazowski CE,Zavislan JM

    更新日期:2007-09-01 00:00:00

  • Permeability of hyperosmotic agent in normal and atherosclerotic vascular tissues.

    abstract::Noninvasive cardiovascular imaging could lead to the early detection and timely treatment of complex atherosclerotic lesions responsible for major cardiovascular events. Recent investigations have suggested that optical coherence tomography (OCT) is an ideal diagnostic tool due to the high resolution this technology a...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2870153

    authors: Ghosn MG,Carbajal EF,Befrui NA,Tellez A,Granada JF,Larin KV

    更新日期:2008-01-01 00:00:00

  • Near-infrared fluorescence goggle system with complementary metal-oxide-semiconductor imaging sensor and see-through display.

    abstract::We have developed a near-infrared (NIR) fluorescence goggle system based on the complementary metal-oxide-semiconductor active pixel sensor imaging and see-through display technologies. The fluorescence goggle system is a compact wearable intraoperative fluorescence imaging and display system that can guide surgery in...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.10.101303

    authors: Liu Y,Njuguna R,Matthews T,Akers WJ,Sudlow GP,Mondal S,Tang R,Gruev V,Achilefu S

    更新日期:2013-10-01 00:00:00

  • Parallel two-channel near- and far-field fluorescence microscopy.

    abstract::We report a new two-channel fluorescence microscopy technique for surface-generated fluorescence. The realized fluorescence microscope allows high resolution imaging of aqueous samples. The core element of the instrument is a parabolic mirror objective that is used to collect the fluorescence at large surface angles a...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2747627

    authors: Verdes D,Ruckstuhl T,Seeger S

    更新日期:2007-05-01 00:00:00

  • Monitoring hemodynamic and morphologic responses to closed head injury in a mouse model using orthogonal diffuse near-infrared light reflectance spectroscopy.

    abstract::The authors' aim is to assess and quantitatively measure brain hemodynamic and morphological variations during closed-head injury (CHI) in mice using orthogonal diffuse near-infrared reflectance spectroscopy (o-DRS). CHI is a type of injury to the head that does not penetrate the skull. Usually, it is caused by mechan...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.4.045003

    authors: Abookasis D,Shochat A,Mathews MS

    更新日期:2013-04-01 00:00:00

  • Angiography with a multifunctional line scanning ophthalmoscope.

    abstract::A multifunctional line scanning ophthalmoscope (mLSO) was designed, constructed, and tested on human subjects. The mLSO could sequentially acquire wide-field, confocal, near-infrared reflectance, fluorescein angiography (FA), and indocyanine green angiography (ICGA) retinal images. The system also included a retinal t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.2.026008

    authors: Hammer DX,Ferguson RD,Patel AH,Vazquez V,Husain D

    更新日期:2012-02-01 00:00:00

  • Scattering coefficient determination in turbid media with backscattered polarized light.

    abstract::A simple empirical method is presented to determine the scattering coefficient mu' s from backscattered polarized images of turbid media. It uses the ratio, pixel by pixel, of two images that are the second and the first backscattered Stokes parameter images Q and I, respectively. Taking this image ratio, then integra...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1924715

    authors: Jaillon F,Saint-Jalmes H

    更新日期:2005-05-01 00:00:00

  • Multiphoton adaptation of a commercial low-cost confocal microscope for live tissue imaging.

    abstract::The Nikon C1 confocal laser scanning microscope is a relatively inexpensive and user-friendly instrument. We describe a straightforward method to convert the C1 for multiphoton microscopy utilizing direct coupling of a femtosecond near-infrared laser into the scan head and fiber optic transmission of emission light to...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3139850

    authors: Mancuso JJ,Larson AM,Wensel TG,Saggau P

    更新日期:2009-05-01 00:00:00