Test-retest reliability of the prefrontal response to affective pictures based on functional near-infrared spectroscopy.

Abstract:

:Functional near-infrared spectroscopy (fNIRS) is being increasingly applied to affective and social neuroscience research; however, the reliability of this method is still unclear. This study aimed to evaluate the test–retest reliability of the fNIRS-based prefrontal response to emotional stimuli. Twenty-six participants viewed unpleasant and neutral pictures, and were simultaneously scanned by fNIRS in two sessions three weeks apart. The reproducibility of the prefrontal activation map was evaluated at three spatial scales (mapwise, clusterwise, and channelwise) at both the group and individual levels. The influence of the time interval was also explored and comparisons were made between longer (intersession) and shorter (intrasession) time intervals. The reliabilities of the activation map at the group level for the mapwise (up to 0.88, the highest value appeared in the intersession assessment) and clusterwise scales (up to 0.91, the highest appeared in the intrasession assessment) were acceptable, indicating that fNIRS may be a reliable tool for emotion studies, especially for a group analysis and under larger spatial scales. However, it should be noted that the individual-level and the channelwise fNIRS prefrontal responses were not sufficiently stable. Future studies should investigate which factors influence reliability, as well as the validity of fNIRS used in emotion studies.

journal_name

J Biomed Opt

authors

Huang Y,Mao M,Zhang Z,Zhou H,Zhao Y,Duan L,Kreplin U,Xiao X,Zhu C

doi

10.1117/1.JBO.22.1.016011

subject

Has Abstract

pub_date

2017-01-01 00:00:00

pages

16011

issue

1

eissn

1083-3668

issn

1560-2281

pii

2598963

journal_volume

22

pub_type

杂志文章
  • Two-photon microscopy and spectroscopy based on a compact confocal scanning head.

    abstract::We have combined a confocal laser scanning head modified for TPE (two-photon excitation) microscopy with some spectroscopic modules to study single molecules and molecular aggregates. The behavior of the TPE microscope unit has been characterized by means of point spread function measurements and of the demonstration ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.1382809

    authors: Diaspro A,Chirico G,Federici F,Cannone F,Beretta S,Robello M

    更新日期:2001-07-01 00:00:00

  • Fast and automatic imaging of immunoenzyme-stained neuronal circuits in the whole brain of Drosophila.

    abstract::Knowledge of neuronal wiring and morphogenesis in Drosophila is essential to understand brain function and dysfunction. The immunoenzyme method based on horseradish peroxidase/diaminobenzidine (HRP/DAB) provides high-contrast images to resolve details underlying neuronal architecture. However, the poor staining penetr...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.19.9.090506

    authors: Tian Q,Yuan J,Li Y,Jiang T,Gong H,Zhou W

    更新日期:2014-09-01 00:00:00

  • Intrauterine photoacoustic and ultrasound imaging probe.

    abstract::Intrauterine photoacoustic and ultrasound imaging are probe-based imaging modalities with translational potential for use in detecting endometrial diseases. This deep-tissue imaging probe design allows for the retrofitting of commercially available endometrial sampling curettes. The imaging probe presented here has a ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.4.046008

    authors: Miranda C,Barkley J,Smith B

    更新日期:2018-04-01 00:00:00

  • Interplay of tumor vascular oxygenation and tumor pO2 observed using near-infrared spectroscopy, an oxygen needle electrode, and 19F MR pO2 mapping.

    abstract::This study investigates the correlation of tumor blood oxygenation and tumor pO(2) with respect to carbogen inhalation. After having refined and validated the algorithms for calculating hemoglobin concentrations, we used near-infrared spectroscopy (NIRS) to measure changes of oxygenated hemoglobin concentration (delta...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1527049

    authors: Kim JG,Zhao D,Song Y,Constantinescu A,Mason RP,Liu H

    更新日期:2003-01-01 00:00:00

  • Precision and Reproducibility of Measurements of Human Corneal Thickness with Rapid Optical Low-Coherence Reflectometry (OLCR).

    abstract::This study investigates the precision and intraindividual variability of a clinical optical pachometer based on low-coherence reflectometry, which was used to measure the central thickness of a human cornea in vivo. The instrument, attached to a slit lamp, is a single mode fiber optic based Michelson interferometer wi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429901

    authors: Bo Hnke M,Masters BR,Wa Lti R,Ballif JJ,Chavanne P,Gianotti R,Salathe RP

    更新日期:1999-01-01 00:00:00

  • New laryngoscope for quantitative high-speed imaging of human vocal folds vibration in the horizontal and vertical direction.

    abstract::We report the design of a novel laser line-triangulation laryngoscope for the quantitative visualization of the three-dimensional movements of human vocal folds during phonation. This is the first successful in vivo recording of the three-dimensional movements of human vocal folds in absolute values. Triangulation ima...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3041164

    authors: George NA,de Mul FF,Qiu Q,Rakhorst G,Schutte HK

    更新日期:2008-11-01 00:00:00

  • Three-dimensional optical method for integrated visualization of mouse islet microstructure and vascular network with subcellular-level resolution.

    abstract::Microscopic visualization of islets of Langerhans under normal and diabetic conditions is essential for understanding the pathophysiology of the disease. The intrinsic opacity of pancreata, however, limits optical accessibility for high-resolution light microscopy of islets in situ. Because the standard microtome-base...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3470241

    authors: Fu YY,Lu CH,Lin CW,Juang JH,Enikolopov G,Sibley E,Chiang AS,Tang SC

    更新日期:2010-07-01 00:00:00

  • Molecular imaging of epidermal growth factor receptor in live cells with refractive index sensitivity using dark-field microspectroscopy and immunotargeted nanoparticles.

    abstract::We present a study using plasmonic nanoparticles (NPs) to image epidermal growth factor receptor (EGFR) in live cells. Through detailed analysis of the NP scattering spectra, we determine the intracellular refractive index (RI) within attoliter volumes inside of the living cells. Molecular imaging is demonstrated usin...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2837450

    authors: Curry AC,Crow M,Wax A

    更新日期:2008-01-01 00:00:00

  • New pediatric vision screener employing polarization-modulated, retinal-birefringence-scanning-based strabismus detection and bull's eye focus detection with an improved target system: opto-mechanical design and operation.

    abstract::Amblyopia ("lazy eye") is a major public health problem, caused by misalignment of the eyes (strabismus) or defocus. If detected early in childhood, there is an excellent response to therapy, yet most children are detected too late to be treated effectively. Commercially available vision screening devices that test fo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.6.067004

    authors: Irsch K,Gramatikov BI,Wu YK,Guyton DL

    更新日期:2014-06-01 00:00:00

  • Laser trap ionization for identification of human erythrocytes with variable hemoglobin quantitation.

    abstract::An approach to an established technique that is potentially applicable for a more comprehensive understanding of the electrical properties of red blood cells (RBCs) is presented. Using a high-intensity gradient laser trap, RBCs can be singly trapped and consequentially ionized. The subsequent dynamics of the ionized c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.5.055005

    authors: Kelley M,Cooper J,Devito D,Mushi R,Aguinaga MDP,Erenso DB

    更新日期:2018-05-01 00:00:00

  • Spatially resolved reflectance spectroscopy for diagnosis of cervical precancer: Monte Carlo modeling and comparison to clinical measurements.

    abstract::We present Monte Carlo modeling studies to provide a quantitative understanding of contrast observed in spatially resolved reflectance spectra of normal and highly dysplastic cervical tissue. Simulations have been carried out to analyze the sensitivity of spectral measurements to a range of changes in epithelial and s...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2398932

    authors: Arifler D,MacAulay C,Follen M,Richards-Kortum R

    更新日期:2006-11-01 00:00:00

  • Analysis of the dispersion compensation of acousto-optic deflectors used for multiphoton imaging.

    abstract::The acousto-optic deflector (AOD) is highly preferred in laser scanning microscopy for its fast scanning ability and random-addressing capability. However, its application in two-photon microscopy is frustrated by the dispersion of the AOD, which results in beam distortion and pulse lengthening. We report the analysis...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714061

    authors: Zeng S,Lv X,Bi K,Zhan C,Li D,Chen WR,Xiong W,Jacques SL,Luo Q

    更新日期:2007-03-01 00:00:00

  • Optical delivery of liposome encapsulated chemical stimuli to neuronal cells.

    abstract::Spatially confined and precise time delivery of neuroactive molecules is an important issue in neurophysiology. In this work we developed a technique for delivering chemical stimuli to cultured neurons consisting in encapsulating the molecules of interest in liposomes. These vectors were then loaded in reservoirs cons...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3616133

    authors: Pinato G,Raffaelli T,D'Este E,Tavano F,Cojoc D

    更新日期:2011-09-01 00:00:00

  • In vivo simultaneous multispectral fluorescence imaging with spectral multiplexed volume holographic imaging system.

    abstract::A simultaneous multispectral fluorescence imaging system incorporating multiplexed volume holographic grating (VHG) is developed to acquire multispectral images of an object in one shot. With the multiplexed VHG, the imaging system can provide the distribution and spectral characteristics of multiple fluorophores in t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.6.060502

    authors: Lv Y,Zhang J,Zhang D,Cai W,Chen N,Luo J

    更新日期:2016-06-01 00:00:00

  • Rab4 and Rab11 coordinately regulate the recycling of angiotensin II type I receptor as demonstrated by fluorescence resonance energy transfer microscopy.

    abstract::The recycling of G-protein-coupled receptors (GPCR) to the cell surface after internalization plays an important role in the regulation of overall GPCR activity. The angiotensin II type I receptor (AT1R) belongs to class B GPCRs that recycle slowly back to the cell surface. Previous studies have proposed that Rab11 co...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2943286

    authors: Li H,Li HF,Felder RA,Periasamy A,Jose PA

    更新日期:2008-05-01 00:00:00

  • Changes in the redox state and endogenous fluorescence of in vivo human skin due to intrinsic and photo-aging, measured by multiphoton tomography with fluorescence lifetime imaging.

    abstract::Ultraviolet radiation from solar exposure is a key extrinsic factor responsible for premature skin aging (i.e., photo-aging). Recent advances using in vivo multiphoton tomography (MPT) demonstrate the efficacy of this approach to assess intrinsic and extrinsic skin aging as an alternative to existing invasive techniqu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.6.061217

    authors: Sanchez WY,Obispo C,Ryan E,Grice JE,Roberts MS

    更新日期:2013-06-01 00:00:00

  • In vivo label-free quantification of liver microcirculation using dual-modality microscopy.

    abstract::Microcirculation lesion is a common symptom of chronic liver diseases in the form of vasculature deformation and circulation alteration. In acute to chronic liver diseases such as biliary atresia, microcirculation lesion can have an early onset. Detection of microcirculation lesion is meaningful for studying the progr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.116006

    authors: Yan J,Kang Y,Xu S,Ong LL,Zhuo S,Bunte RM,Chen N,Asada HH,So PT,Wanless IR,Yu H

    更新日期:2014-01-01 00:00:00

  • Multi-reference global registration of individual A-lines in adaptive optics optical coherence tomography retinal images.

    abstract:SIGNIFICANCE:Adaptive optics optical coherence tomography (AO-OCT) technology enables non-invasive, high-resolution three-dimensional (3D) imaging of the retina and promises earlier detection of ocular disease. However, AO-OCT data are corrupted by eye-movement artifacts that must be removed in post-processing, a proce...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.26.1.016001

    authors: Kurokawa K,Crowell JA,Do N,Lee JJ,Miller DT

    更新日期:2021-01-01 00:00:00

  • Multispectral in vivo three-dimensional optical coherence tomography of human skin.

    abstract::The capability of optical coherence tomography (OCT) to perform "optical biopsy" of tissues within a depth range of 1 to 2 mm with micron-scale resolution in real time makes it a promising biomedical imaging modality for dermatologic applications. Three high-speed, spectrometer-based frequency-domain OCT systems opera...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3400665

    authors: Alex A,Povazay B,Hofer B,Popov S,Glittenberg C,Binder S,Drexler W

    更新日期:2010-03-01 00:00:00

  • Time-dependent blood flow and oxygenation in human skeletal muscles measured with noninvasive near-infrared diffuse optical spectroscopies.

    abstract::We have employed near-infrared optical methods to measure noninvasively the dynamics of muscle blood flow and oxygen saturation (StO2) during cuff occlusion and plantar flexion exercise. Relative muscle oxygen consumption (rVO2) was also computed from these data. Diffuse correlation spectroscopy provides information a...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1884603

    authors: Yu G,Durduran T,Lech G,Zhou C,Chance B,Mohler ER 3rd,Yodh AG

    更新日期:2005-03-01 00:00:00

  • Technical considerations in longitudinal multispectral small animal molecular imaging.

    abstract::In a previous study, we investigated physical methods to reduce whole-body, diet-related autofluorescence interference in several mouse strains through changes in animal diet. Measurements of mice with an in vivo multispectral imaging system over a 21-day period allowed for the quantification of concentration changes ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2799188

    authors: Bouchard MB,MacLaurin SA,Dwyer PJ,Mansfield J,Levenson R,Krucker T

    更新日期:2007-09-01 00:00:00

  • Photoacoustic properties of anterior ocular tissues.

    abstract::Clinical imaging techniques for the anterior segment of the eye provide excellent anatomical information, but molecular imaging techniques are lacking. Molecular photoacoustic imaging is one option to address this need, but implementation requires use of contrast agents to distinguish molecular targets from background...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.5.056004

    authors: Kubelick KP,Snider EJ,Ethier CR,Emelianov S

    更新日期:2019-05-01 00:00:00

  • Evaluation of the contribution of the renal capsule and cortex to kidney autofluorescence intensity under ultraviolet excitation.

    abstract::The use of reduced nicotinamide adenine dinucleotide (NADH) fluorescence to gain metabolic information on kidneys in response to an alteration in oxygen availability has previously been experimentally demonstrated, but signal quantification has not, to date, been addressed. In this work the relative contribution to ra...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3094948

    authors: Raman RN,Pivetti CD,Rubenchik AM,Matthews DL,Troppmann C,Demos SG

    更新日期:2009-03-01 00:00:00

  • Imaging of skin birefringence for human scar assessment using polarization-sensitive optical coherence tomography aided by vascular masking.

    abstract::We demonstrate the in vivo assessment of human scars by parametric imaging of birefringence using polarization-sensitive optical coherence tomography (PS-OCT). Such in vivo assessment is subject to artifacts in the detected birefringence caused by scattering from blood vessels. To reduce these artifacts, we preprocess...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.12.126014

    authors: Gong P,Chin L,Es'haghian S,Liew YM,Wood FM,Sampson DD,McLaughlin RA

    更新日期:2014-12-01 00:00:00

  • Intraoperative hyperspectral determination of human tissue properties.

    abstract::We address the automatic differentiation of human tissue using multispectral imaging with promising potential for automatic visualization during surgery. Currently, tissue types have to be continuously differentiated based on the surgeon's knowledge only. Further, automatic methods based on optical in vivo properties ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.9.091409

    authors: Wisotzky EL,Uecker FC,Arens P,Dommerich S,Hilsmann A,Eisert P

    更新日期:2018-05-01 00:00:00

  • Time-resolved imaging of optical coefficients through murine chest cavities.

    abstract::As small animal optical imaging and tomography are gaining popularity for interrogating functional and molecular events in vivo, it becomes increasingly necessary to gain knowledge of the optical properties of the species investigated to better understand and describe photon propagation through their tissues. To achie...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2400702

    authors: Niedre MJ,Turner GM,Ntziachristos V

    更新日期:2006-11-01 00:00:00

  • Early development of optical low-coherence reflectometry and some recent biomedical applications.

    abstract::This paper explains the term low-coherence interferometry, reviews the early development of optical low-coherence reflectometry, and shows some of the paths that led to the field of biomedical optics. This paper demonstrates that early technical developments in the telecommunications industry resulted in a myriad of t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429914

    authors: Masters BR

    更新日期:1999-04-01 00:00:00

  • In vivo microvascular network imaging of the human retina combined with an automatic three-dimensional segmentation method.

    abstract::Microvascular network of the retina plays an important role in diagnosis and monitoring of various retinal diseases. We propose a three-dimensional (3-D) segmentation method with intensity-based Doppler variance (IBDV) based on swept-source optical coherence tomography. The automatic 3-D segmentation method is used to...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.7.076003

    authors: Huang S,Piao Z,Zhu J,Lu F,Chen Z

    更新日期:2015-07-01 00:00:00

  • Vector extrapolation methods for accelerating iterative reconstruction methods in limited-data photoacoustic tomography.

    abstract::As limited data photoacoustic tomographic image reconstruction problem is known to be ill-posed, the iterative reconstruction methods were proven to be effective in terms of providing good quality initial pressure distribution. Often, these iterative methods require a large number of iterations to converge to a soluti...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.7.071204

    authors: Awasthi N,Kalva SK,Pramanik M,Yalavarthy PK

    更新日期:2018-02-01 00:00:00

  • Pulsed photoacoustic flow imaging with a handheld system.

    abstract::Flow imaging is an important technique in a range of disease areas, but estimating low flow speeds, especially near the walls of blood vessels, remains challenging. Pulsed photoacoustic flow imaging can be an alternative since there is little signal contamination from background tissue with photoacoustic imaging. We p...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.2.026004

    authors: van den Berg PJ,Daoudi K,Steenbergen W