Multi-reference global registration of individual A-lines in adaptive optics optical coherence tomography retinal images.

Abstract:

SIGNIFICANCE:Adaptive optics optical coherence tomography (AO-OCT) technology enables non-invasive, high-resolution three-dimensional (3D) imaging of the retina and promises earlier detection of ocular disease. However, AO-OCT data are corrupted by eye-movement artifacts that must be removed in post-processing, a process rendered time-consuming by the immense quantity of data. AIM:To efficiently remove eye-movement artifacts at the level of individual A-lines, including those present in any individual reference volume. APPROACH:We developed a registration method that cascades (1) a 3D B-scan registration algorithm with (2) a global A-line registration algorithm for correcting torsional eye movements and image scaling and generating global motion-free coordinates. The first algorithm corrects 3D translational eye movements to a single reference volume, accelerated using parallel computing. The second algorithm combines outputs of multiple runs of the first algorithm using different reference volumes followed by an affine transformation, permitting registration of all images to a global coordinate system at the level of individual A-lines. RESULTS:The 3D B-scan algorithm estimates and corrects 3D translational motions with high registration accuracy and robustness, even for volumes containing microsaccades. Averaging registered volumes improves our image quality metrics up to 22 dB. Implementation in CUDA™ on a graphics processing unit registers a 512  ×  512  ×  512 volume in only 10.6 s, 150 times faster than MATLAB™ on a central processing unit. The global A-line algorithm minimizes image distortion, improves regularity of the cone photoreceptor mosaic, and supports enhanced visualization of low-contrast retinal cellular features. Averaging registered volumes improves our image quality up to 9.4 dB. It also permits extending the imaging field of view (∼2.1  ×  ) and depth of focus (∼5.6  ×  ) beyond what is attainable with single-reference registration. CONCLUSIONS:We can efficiently correct eye motion in all 3D at the level of individual A-lines using a global coordinate system.

journal_name

J Biomed Opt

authors

Kurokawa K,Crowell JA,Do N,Lee JJ,Miller DT

doi

10.1117/1.JBO.26.1.016001

subject

Has Abstract

pub_date

2021-01-01 00:00:00

issue

1

eissn

1083-3668

issn

1560-2281

pii

JBO-200266R

journal_volume

26

pub_type

杂志文章
  • Oblique incidence reflectometry: optical models and measurements using a side-viewing gradient index lens-based endoscopic imaging system.

    abstract::A side-viewing, 2.3-mm diameter oblique incidence reflectometry endoscope has been designed to obtain optical property measurements of turbid samples. Light from a single-mode fiber is relayed obliquely onto the tissue with a gradient index lens-based distal optics assembly and the resulting diffuse reflectance profil...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.6.067002

    authors: Wall RA,Barton JK

    更新日期:2014-06-01 00:00:00

  • Early detection of high-grade squamous intraepithelial lesions in the cervix with quantitative spectroscopic imaging.

    abstract::Quantitative spectroscopy has recently been extended from a contact-probe to wide-area spectroscopic imaging to enable mapping of optical properties across a wide area of tissue. We train quantitative spectroscopic imaging (QSI) to identify cervical high-grade squamous intraepithelial lesions (HSILs) in 34 subjects un...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.7.076013

    authors: Lau C,Mirkovic J,Yu CC,O'Donoghue GP,Galindo L,Dasari R,de las Morenas A,Feld M,Stier E

    更新日期:2013-07-01 00:00:00

  • In vivo label-free quantification of liver microcirculation using dual-modality microscopy.

    abstract::Microcirculation lesion is a common symptom of chronic liver diseases in the form of vasculature deformation and circulation alteration. In acute to chronic liver diseases such as biliary atresia, microcirculation lesion can have an early onset. Detection of microcirculation lesion is meaningful for studying the progr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.116006

    authors: Yan J,Kang Y,Xu S,Ong LL,Zhuo S,Bunte RM,Chen N,Asada HH,So PT,Wanless IR,Yu H

    更新日期:2014-01-01 00:00:00

  • Confocal reflectance and two-photon microscopy studies of a songbird skull for preparation of transcranial imaging.

    abstract::We present experiments and analyses of confocal reflectance and two-photon microscopy studies of zebra finch skull samples. The thin and hollow structure of these birds' skulls is quite translucent, which can allow in vivo transcranial two-photon imaging for brain activation monitoring. However, the skull structure is...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3155522

    authors: Abi-Haidar D,Olivier T

    更新日期:2009-05-01 00:00:00

  • Confocal detection of planar homogeneous and heterogeneous immunosorbent assays.

    abstract::Optically sectioned detection of fluorescence immunoassays using a confocal microscope enables the creation of both homo- and heterogeneous planar format assays. We report a set assays requiring optically sectioned detection using a model system and analysis procedures for separating signals of a surface layer from an...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3268772

    authors: Ghafari H,Zhou Y,Ali S,Hanley QS

    更新日期:2009-11-01 00:00:00

  • Simultaneous imaging of multiple focal planes for three-dimensional microscopy using ultra-high-speed adaptive optics.

    abstract::Traditional white-light and fluorescent imaging techniques provide powerful methods to extract high-resolution information from two-dimensional (2-D) sections, but to retrieve information from a three-dimensional (3-D) volume they require relatively slow scanning methods that result in increased acquisition time. Usin...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.17.5.050505

    authors: Duocastella M,Sun B,Arnold CB

    更新日期:2012-05-01 00:00:00

  • Prehistological evaluation of benign and malignant pigmented skin lesions with optical computed tomography.

    abstract::Discrimination of benign and malignant melanocytic lesions is a major issue in clinical dermatology. Assessment of the thickness of melanoma is critical for prognosis and treatment selection. We aimed to evaluate a novel optical computed tomography (optical-CT) system as a tool for three-dimensional (3-D) imaging of m...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.6.066004

    authors: Kokolakis A,Zacharakis G,Krasagakis K,Lasithiotakis K,Favicchio R,Spiliopoulos G,Giannikaki E,Ripoll J,Tosca A

    更新日期:2012-06-01 00:00:00

  • Detecting glucose-induced changes in in vitro and in vivo experiments with optical coherence tomography.

    abstract::Optical clearing is a well-known phenomenon. It is based on the matching of refractive indices of a bulk material and scattering particles. The same principle is also used in scattering-based optical measurements of different constituents, such as glucose. By registering changes in scattering, it is possible to evalua...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2904957

    authors: Kinnunen M,Myllylä R,Vainio S

    更新日期:2008-03-01 00:00:00

  • Special Section Guest Editorial: Celebrating the Exponential Growth of Optoacoustic/Photoacoustic Imaging.

    abstract::Guest editors introduce contributors to the Special Section Celebrating the Exponential Growth of Optoacoustic/Photoacoustic Imaging. ...

    journal_title:Journal of biomedical optics

    pub_type: 社论

    doi:10.1117/1.JBO.24.12.121901

    authors: Beard P,Anastasio M,Oraevsky AA,Wang LV

    更新日期:2019-12-01 00:00:00

  • Characterization of a multicore fiber image guide for nonlinear endoscopic imaging using two-photon fluorescence and second-harmonic generation.

    abstract::Multiphoton microscopy (MPM) has the capacity to record second-harmonic generation (SHG) and endogenous two-photon excitation fluorescence (2PEF) signals emitted from biological tissues. The development of fiber-based miniaturized endomicroscopes delivering pulses in the femtosecond range will allow the transfer of MP...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.10.106004

    authors: Garofalakis A,Kruglik SG,Mansuryan T,Gillibert A,Thiberville L,Louradour F,Vever-Bizet C,Bourg-Heckly G

    更新日期:2019-10-01 00:00:00

  • All fiber optics circular-state swept source polarization-sensitive optical coherence tomography.

    abstract::A swept source (SS)-based circular-state (CS) polarization-sensitive optical coherence tomography (PS-OCT) constructed entirely with polarization-maintaining fiber optics components is proposed with the experimental verification. By means of the proposed calibration scheme, bulk quarter-wave plates can be replaced by ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.2.021110

    authors: Lin H,Kao MC,Lai CM,Huang JC,Kuo WC

    更新日期:2014-02-01 00:00:00

  • Toward soft-tissue elastography using digital holography to monitor surface acoustic waves.

    abstract::Measuring the elasticity distribution inside the human body is of great interest because elastic abnormalities can serve as indicators of several diseases. We present a method for mapping elasticity inside soft tissues by imaging surface acoustic waves (SAWs) with digital holographic interferometry. With this method, ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3646211

    authors: Li S,Mohan KD,Sanders WW,Oldenburg AL

    更新日期:2011-11-01 00:00:00

  • Chemical reactivation of fluorescein isothiocyanate immunofluorescence-labeled resin-embedded samples.

    abstract::Resin embedding is widely used and facilitates microscopic imaging of biological tissues. In contrast, quenching of fluorescence during embedding process hinders the application of resin embedding for imaging of fluorescence-labeled samples. For samples expressing fluorescent proteins, it has been demonstrated that th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.2.020501

    authors: Li L,Rao G,Lv X,Chen R,Cheng X,Wang X,Zeng S,Liu X

    更新日期:2018-02-01 00:00:00

  • Interstitial Doppler optical coherence tomography monitors microvascular changes during photodynamic therapy in a Dunning prostate model under varying treatment conditions.

    abstract::We measure the tumor vascular response to varying irradiance rates during photodynamic therapy (PDT) in a Dunning rat prostate model with interstitial Doppler optical coherence tomography (IS-DOCT). Rats are given a photosensitizer drug, Photofrin, and the tumors are exposed to light (635 nm) with irradiance rates ran...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2744068

    authors: Standish BA,Jin X,Smolen J,Mariampillai A,Munce NR,Wilson BC,Vitkin IA,Yang VX

    更新日期:2007-05-01 00:00:00

  • Dependence of image quality on image operator and noise for optical diffusion tomography.

    abstract::By applying linear perturbation theory to the radiation transport equation, the inverse problem of optical diffusion tomography can be reduced to a set of linear equations, Wμ=R, where W is the weight function, μ are the cross-section perturbations to be imaged, and R is the detector readings perturbations. We have st...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429870

    authors: Chang J,Graber HL,Barbour RL

    更新日期:1998-04-01 00:00:00

  • Fluorescence confocal endomicroscopy of the cervix: pilot study on the potential and limitations for clinical implementation.

    abstract::Current diagnostic capabilities and limitations of fluorescence endomicroscopy in the cervix are assessed by qualitative and quantitative image analysis. Four cervical tissue types are investigated: normal columnar epithelium, normal and precancerous squamous epithelium, and stromal tissue. This study focuses on the p...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.126011

    authors: Schlosser C,Bodenschatz N,Lam S,Lee M,McAlpine JN,Miller DM,Van Niekerk DJ,Follen M,Guillaud M,MacAulay CE,Lane PM

    更新日期:2016-12-01 00:00:00

  • Graphics processing unit-based dispersion encoded full-range frequency-domain optical coherence tomography.

    abstract::Dispersion encoded full-range (DEFR) frequency-domain optical coherence tomography (FD-OCT) and its enhanced version, fast DEFR, utilize dispersion mismatch between sample and reference arm to eliminate the ambiguity in OCT signals caused by non-complex valued spectral measurement, thereby numerically doubling the usa...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.077007

    authors: Wang L,Hofer B,Guggenheim JA,Povazay B

    更新日期:2012-07-01 00:00:00

  • Dialysis-assisted fiber optic spectroscopy for in situ biomedical sensing.

    abstract::A miniature fiber optic spectrometer enclosed within a semipermeable (dialysis) membrane is proposed for in vivo interstitial sensing applications. The semipermeable membrane acts as a molecular filter, allowing only small molecules to pass through to the sampling volume. This filtering, in principle, should enable co...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2166086

    authors: Blazkiewicz P,Blazkiewicz K,Verhaege A,Anissimov YG,Roberts MS,Zvyagin AV

    更新日期:2006-01-01 00:00:00

  • Light scattering of human red blood cells during metabolic remodeling of the membrane.

    abstract::We present the light scattering properties of individual human red blood cells (RBCs). We show that both the RBC static and dynamic scattering signals are altered by adenosine 5'-triphosphate (ATP)-driven membrane metabolic remodeling. To measure the light scattering signal from individual RBCs, we use diffraction pha...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3524509

    authors: Park Y,Best-Popescu CA,Dasari RR,Popescu G

    更新日期:2011-01-01 00:00:00

  • Measuring red blood cell flow dynamics in a glass capillary using Doppler optical coherence tomography and Doppler amplitude optical coherence tomography.

    abstract::Blood, being a suspension of deformable red cells suspended in plasma, displays flow dynamics considerably more complicated than those of an ideal Newtonian fluid. Flow dynamics in blood capillaries of a few hundred micrometers in diameter are investigated using Doppler optical coherence tomography (DOCT) and Doppler ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1781163

    authors: Moger J,Matcher SJ,Winlove CP,Shore A

    更新日期:2004-09-01 00:00:00

  • Spatial extent of cochlear infrared neural stimulation determined by tone-on-light masking.

    abstract::Artificial neural stimulation is widely used in clinic, rehabilitation, and research. One of the limitations of electrical stimulation is the current spread in tissue. Recently, pulsed mid-infrared laser stimulation of nerves has been investigated as an alternative stimulation method. The likely benefits of infrared n...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3655590

    authors: Matic AI,Walsh JT Jr,Richter CP

    更新日期:2011-11-01 00:00:00

  • Detection of canine skin and subcutaneous tumors by visible and near-infrared diffuse reflectance spectroscopy.

    abstract::Cancer is the main cause of canine morbidity and mortality. The existing evaluation of tumors requires an experienced veterinarian and usually includes invasive procedures (e.g., fine-needle aspiration) that can be unpleasant for the dog and the owner. We investigate visible and near-infrared diffuse reflectance spect...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.3.037003

    authors: Cugmas B,Plavec T,Bregar M,Naglič P,Pernuš F,Likar B,Bürmen M

    更新日期:2015-03-01 00:00:00

  • Extraction of optical properties and prediction of light distribution in rat brain tissue.

    abstract::Predicting the distribution of light inside any turbid media, such as biological tissue, requires detailed information about the optical properties of the medium, including the absorption and scattering coefficients and the anisotropy factor. Particularly, in biophotonic applications where photons directly interact wi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.7.075001

    authors: Azimipour M,Baumgartner R,Liu Y,Jacques SL,Eliceiri K,Pashaie R

    更新日期:2014-01-01 00:00:00

  • Site-specific gene transfer into the rat spinal cord by photomechanical waves.

    abstract::Nonviral, site-specific gene delivery to deep tissue is required for gene therapy of a spinal cord injury. However, an efficient method satisfying these requirements has not been established. This study demonstrates efficient and targeted gene transfer into the spinal cord by using photomechanical waves (PMWs), which ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3642014

    authors: Ando T,Sato S,Toyooka T,Uozumi Y,Nawashiro H,Ashida H,Obara M

    更新日期:2011-10-01 00:00:00

  • Hardware implementation algorithm and error analysis of high-speed fluorescence lifetime sensing systems using center-of-mass method.

    abstract::A new, simple, high-speed, and hardware-only integration-based fluorescence-lifetime-sensing algorithm using a center-of-mass method (CMM) is proposed to implement lifetime calculations, and its signal-to-noise-ratio based on statistics theory is also deduced. Compared to the commonly used iterative least-squares meth...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3309737

    authors: Li DU,Rae B,Andrews R,Arlt J,Henderson R

    更新日期:2010-01-01 00:00:00

  • Diabetic retinopathy assessed by dynamic light scattering and corneal autofluorescence.

    abstract::Autofluorescence of the cornea within specific wavelength region and dynamic light scattering measurements of ocular tissue have both been used for early-stage detection of the presence of diabetic retinopathy. In the present study, autofluorescence of the cornea and dynamic light scattering in the cornea and vitreous...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429882

    authors: Rovati L,Fankhauser F,Docchio F,Van Best J

    更新日期:1998-07-01 00:00:00

  • In vivo assessment and evaluation of lung tissue morphologic and physiological changes from non-contact endoscopic reflectance spectroscopy for improving lung cancer detection.

    abstract::We present a method for lung cancer detection exploiting reflectance spectra measured in vivo during endoscopic imaging of the lung. The measured reflectance spectra were analyzed using a specially developed light-transport model to obtain quantitative information about cancer-related, physiological, and morphologic c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2337529

    authors: Fawzy YS,Petek M,Tercelj M,Zeng H

    更新日期:2006-07-01 00:00:00

  • Human graft cornea and laser incisions imaging with micrometer scale resolution full-field optical coherence tomography.

    abstract::Micrometer scale resolution full-field optical coherence tomography (FF-OCT) is developed for imaging human graft corneas. Three-dimensional (3-D) images with ultrahigh resolution (respectively, 1 and 1.5 μm in the axial and transverse directions), comparable to traditional histological sections, are obtained allowing...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3486544

    authors: Latour G,Georges G,Lamoine LS,Deumié C,Conrath J,Hoffart L

    更新日期:2010-09-01 00:00:00

  • Simulating the scanning of a focused beam through scattering media using a numerical solution of Maxwell's equations.

    abstract::A highly efficient method based on Maxwell's theory was developed, which enables the calculation of the scanning of a focused beam through scattering media. Maxwell's equations were numerically solved in two dimensions using finite difference time domain simulations. The modeling of the focused beam was achieved by ap...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.7.071404

    authors: Elmaklizi A,Schäfer J,Kienle A

    更新日期:2014-07-01 00:00:00

  • Implantable photonic devices for improved medical treatments.

    abstract::An evolving area of biomedical research is related to the creation of implantable units that provide various possibilities for imaging, measurement, and the monitoring of a wide range of diseases and intrabody phototherapy. The units can be autonomic or built-in in some kind of clinically applicable implants. Because ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.108001

    authors: Sheinman V,Rudnitsky A,Toichuev R,Eshiev A,Abdullaeva S,Egemkulov T,Zalevsky Z

    更新日期:2014-01-01 00:00:00