Confocal detection of planar homogeneous and heterogeneous immunosorbent assays.

Abstract:

:Optically sectioned detection of fluorescence immunoassays using a confocal microscope enables the creation of both homo- and heterogeneous planar format assays. We report a set assays requiring optically sectioned detection using a model system and analysis procedures for separating signals of a surface layer from an overlying solution. A model sandwich assay with human immunoglobulin G as the target antigen is created on a glass substrate. The prepared surfaces are exposed to antigen and a FITC-labeled secondary antibody. The resulting preparations are either read directly to provide a homogeneous assay or after wash steps, giving a heterogeneous assay. The simplicity of the object shapes arising from the planar format makes the decomposition of analyte signals from the thin film bound to the surface and overlayer straightforward. Measured response functions of the thin film and overlayer fit well to the Cauchy-Lorentz and cumulative Cauchy-Lorentz functions, respectively, enabling the film and overlayer to be separated. Under the conditions used, the detection limits for the homogeneous and heterogeneous forms of the assay are 2.2 and 5.5 ng/ml, respectively. Planar format, confocally read fluorescence assays enable wash-free detection of antigens and should be applicable to a wide range of assays involving surface-bound species.

journal_name

J Biomed Opt

authors

Ghafari H,Zhou Y,Ali S,Hanley QS

doi

10.1117/1.3268772

subject

Has Abstract

pub_date

2009-11-01 00:00:00

pages

064022

issue

6

eissn

1083-3668

issn

1560-2281

journal_volume

14

pub_type

杂志文章
  • Study of cadmium-induced cytotoxicity using two-photon excitation endogenous fluorescence microscopy.

    abstract::We demonstrate that using time-resolved two-photon excitation endogenous fluorescence microscopy, the cadmium (Cd)-induced cellular toxic level can be assessed by the free-to protein-bound reduced nicotinamide adenine dinucleotide (free/bound NADH) ratio in a living cell. NADH fluorescence excited at 730 nm is capture...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3250293

    authors: Li D,Yang MS,Lin T,Zheng W,Qu JY

    更新日期:2009-09-01 00:00:00

  • Comparison of cerebral oxygen saturation in premature infants by near-infrared spatially resolved spectroscopy: observations on probe-dependent bias.

    abstract::Spatially resolved spectroscopy (SRS) allows the estimation of absolute tissue oxygen saturation, the ratio of oxygenated to total hemoglobin concentration, which may facilitate the comparison of results among patients. Eighty-two premature infants were included over two years. The cerebral tissue oxygenation index (c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3013454

    authors: Sorensen LC,Leung TS,Greisen G

    更新日期:2008-11-01 00:00:00

  • Chemical reactivation of fluorescein isothiocyanate immunofluorescence-labeled resin-embedded samples.

    abstract::Resin embedding is widely used and facilitates microscopic imaging of biological tissues. In contrast, quenching of fluorescence during embedding process hinders the application of resin embedding for imaging of fluorescence-labeled samples. For samples expressing fluorescent proteins, it has been demonstrated that th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.2.020501

    authors: Li L,Rao G,Lv X,Chen R,Cheng X,Wang X,Zeng S,Liu X

    更新日期:2018-02-01 00:00:00

  • Infrared spectroscopic imaging of renal tumor tissue.

    abstract::Fourier transform infrared (FTIR) spectroscopic imaging has been used to probe the biochemical composition of human renal tumor tissue and adjacent normal tissue. Freshly resected renal tumor tissue from surgery was prepared as a thin cryosection and examined by FTIR spectroscopic imaging. Tissue types could be discri...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3622292

    authors: Sablinskas V,Urboniene V,Ceponkus J,Laurinavicius A,Dasevicius D,Jankevicius F,Hendrixson V,Koch E,Steiner G

    更新日期:2011-09-01 00:00:00

  • Effect of motion artifacts and their correction on near-infrared spectroscopy oscillation data: a study in healthy subjects and stroke patients.

    abstract::Functional near-infrared spectroscopy is prone to contamination by motion artifacts (MAs). Motion correction algorithms have previously been proposed and their respective performance compared for evoked rain activation studies. We study instead the effect of MAs on "oscillation" data which is at the basis of functiona...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.5.056011

    authors: Selb J,Yücel MA,Phillip D,Schytz HW,Iversen HK,Vangel M,Ashina M,Boas DA

    更新日期:2015-05-01 00:00:00

  • Hyperspectral imaging based method for fast characterization of kidney stone types.

    abstract::The formation of kidney stones is a common and highly studied disease, which causes intense pain and presents a high recidivism. In order to find the causes of this problem, the characterization of the main compounds is of great importance. In this sense, the analysis of the composition and structure of the stone can ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.076027

    authors: Blanco F,López-Mesas M,Serranti S,Bonifazi G,Havel J,Valiente M

    更新日期:2012-07-01 00:00:00

  • Evidence of a heterogeneous tissue oxygenation: renal ischemia/reperfusion injury in a large animal model.

    abstract::Renal ischemia that occurs intraoperatively during procedures requiring clamping of the renal artery (such as renal procurement for transplantation and partial nephrectomy for renal cancer) is known to have a significant impact on the viability of that kidney. To better understand the dynamics of intraoperative renal ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.035001

    authors: Crane NJ,Huffman SW,Alemozaffar M,Gage FA,Levin IW,Elster EA

    更新日期:2013-03-01 00:00:00

  • Characterization and three-dimensional localization of cancerous prostate tissue using backscattering scanning polarization imaging and independent component analysis.

    abstract::Characterization and three-dimensional (3-D) localization of human cancerous prostate tissue embedded in normal prostate tissue were demonstrated using backscattering scanning polarization imaging and an inverse imaging reconstruction algorithm, optical tomography using independent component analysis (OPTICA). Two-dim...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.081419

    authors: Pu Y,Wang W,Xu M,Eastham JA,Tang G,Alfano RR

    更新日期:2012-08-01 00:00:00

  • In vivo photoacoustic imaging of mouse embryos.

    abstract::The ability to noninvasively image embryonic vascular anatomy in mouse models is an important requirement for characterizing the development of the normal cardiovascular system and malformations in the heart and vascular supply. Photoacoustic imaging, which can provide high resolution non invasive images of the vascul...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.6.061220

    authors: Laufer J,Norris F,Cleary J,Zhang E,Treeby B,Cox B,Johnson P,Scambler P,Lythgoe M,Beard P

    更新日期:2012-06-01 00:00:00

  • Near infrared fluorescent optical imaging for nodal staging.

    abstract::Current techniques to assess lymph node metastases in cancer patients include lymphoscintigraphy after administration of a nonspecific radiocolloid in order to locate and resect lymph nodes for pathological examination of harbored cancer cells. Clinical trials involving intradermal or subcutaneous injection of antibod...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.2953498

    authors: Sampath L,Wang W,Sevick-Muraca EM

    更新日期:2008-07-01 00:00:00

  • High-speed 1310 nm-band spectral domain optical coherence tomography at 184,000 lines per second.

    abstract::We propose a useful method to boost the imaging speed for spectral domain optical coherence tomography (SDOCT) by multiplying a number of high-speed spectrometers used in the system with selective precise control of data-recording and data-reading phases for spectral cameras employed in each spectrometer. To demonstra...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3592492

    authors: An L,Guan G,Wang RK

    更新日期:2011-06-01 00:00:00

  • Multimodal optical measurement in vitro of surface deformations and wall thickness of the pressurized aortic arch.

    abstract::Computational modeling of arterial mechanics continues to progress, even to the point of allowing the study of complex regions such as the aortic arch. Nevertheless, most prior studies assign homogeneous and isotropic material properties and constant wall thickness even when implementing patient-specific luminal geome...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.4.046005

    authors: Genovese K,Humphrey JD

    更新日期:2015-04-01 00:00:00

  • Monitoring the progression from intraductal carcinoma to invasive ductal carcinoma based on multiphoton microscopy.

    abstract::Intraductal carcinoma is a precancerous lesion of the breast and the immediate precursor of invasive ductal carcinoma. Multiphoton microscopy (MPM) was used to monitor the progression from intraductal carcinoma to invasive ductal carcinoma, which can improve early detection of precursor lesions and halt progression to...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.9.096007

    authors: Wu Y,Fu F,Lian Y,Nie Y,Zhuo S,Wang C,Chen J

    更新日期:2015-09-01 00:00:00

  • Hyperspectral multiplex single-particle tracking of different receptor subtypes labeled with quantum dots in live neurons.

    abstract::The efficacy of existing therapies and the discovery of innovative treatments for central nervous system (CNS) diseases have been limited by the lack of appropriate methods to investigate complex molecular processes at the synaptic level. To improve our capability to investigate complex mechanisms of synaptic signalin...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.4.046008

    authors: Labrecque S,Sylvestre JP,Marcet S,Mangiarini F,Bourgoin B,Verhaegen M,Blais-Ouellette S,De Koninck P

    更新日期:2016-04-30 00:00:00

  • Quantitative microscopy and nanoscopy of sickle red blood cells performed by wide field digital interferometry.

    abstract::We have applied wide-field digital interferometry (WFDI) to examine the morphology and dynamics of live red blood cells (RBCs) from individuals who suffer from sickle cell anemia (SCA), a genetic disorder that affects the structure and mechanical properties of RBCs. WFDI is a noncontact, label-free optical microscopy ...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3556717

    authors: Shaked NT,Satterwhite LL,Telen MJ,Truskey GA,Wax A

    更新日期:2011-03-01 00:00:00

  • Ultrafast optical property map generation using lookup tables.

    abstract::Imaging technologies working in the spatial frequency domain are becoming increasingly popular for generating wide-field maps of optical properties, enabling rapid analysis of tissue parameters. While acquisition methods have become faster and are now performing in real-time, processing methods remain slow, precluding...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.11.110501

    authors: Angelo J,Vargas CR,Lee BT,Bigio IJ,Gioux S

    更新日期:2016-11-01 00:00:00

  • Neural networks improve brain cancer detection with Raman spectroscopy in the presence of operating room light artifacts.

    abstract::Invasive brain cancer cells cannot be visualized during surgery and so they are often not removed. These residual cancer cells give rise to recurrences.

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.9.094002

    authors: Jermyn M,Desroches J,Mercier J,Tremblay MA,St-Arnaud K,Guiot MC,Petrecca K,Leblond F

    更新日期:2016-09-01 00:00:00

  • Eigenvector-based spatial filtering for reduction of physiological interference in diffuse optical imaging.

    abstract::Diffuse optical imaging is an effective technique for noninvasive functional brain imaging. However, the measurements respond to systemic hemodynamic fluctuations caused by the cardiac cycle, respiration, and blood pressure, which may obscure or overwhelm the desired stimulus-evoked response. Previous work on this pro...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1852552

    authors: Zhang Y,Brooks DH,Franceschini MA,Boas DA

    更新日期:2005-01-01 00:00:00

  • Use of laser tweezers to analyze sperm motility and mitochondrial membrane potential.

    abstract::We combine laser tweezers with custom computer tracking software and robotics to analyze the motility [swimming speed, VCL (curvilinear velocity), and swimming force in terms of escape laser power (Pesc)] and energetics [mitochondrial membrane potential (MP)] of individual sperm. Domestic dog sperm are labeled with a ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2839051

    authors: Nascimento JM,Shi LZ,Chandsawangbhuwana C,Tam J,Durrant B,Botvinick EL,Berns MW

    更新日期:2008-01-01 00:00:00

  • Quantum cascade laser-based hyperspectral imaging of biological tissue.

    abstract::The spectroscopy of analyte-specific molecular vibrations in tissue thin sections has opened up a path toward histopathology without the need for tissue staining. However, biomedical vibrational imaging has not yet advanced from academic research to routine histopathology due to long acquisition times for the microsco...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.111607

    authors: Kröger N,Egl A,Engel M,Gretz N,Haase K,Herpich I,Kränzlin B,Neudecker S,Pucci A,Schönhals A,Vogt J,Petrich W

    更新日期:2014-01-01 00:00:00

  • Monte-Carlo-based model for the extraction of intrinsic fluorescence from turbid media.

    abstract::A Monte-Carlo-based model of fluorescence is developed that is capable of extracting the intrinsic fluorescence properties of tissue, which are independent of the absorption and scattering properties of tissue. This model is flexible in its applicability to different illumination-collection geometries and is also vali...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2907161

    authors: Palmer GM,Ramanujam N

    更新日期:2008-03-01 00:00:00

  • Processing algorithms for tracking speckle shifts in optical elastography of biological tissues.

    abstract::Parametric and nonparametric data processing schemes for analyzing translating laser speckle data used to investigate the mechanical behavior of biological tissues are examined. Cross-correlation, minimum mean square estimator, maximum likelihood, and maximum entropy approaches are discussed and compared on speckle da...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1412224

    authors: Duncan DD,Kirkpatrick SJ

    更新日期:2001-10-01 00:00:00

  • Optical fiber Bragg grating-instrumented silicone liner for interface pressure measurement within prosthetic sockets of lower-limb amputees.

    abstract::This paper presents a fiber Bragg grating (FBG)-instrumented prosthetic silicone liner that provides cushioning for the residual limb and can successfully measure interface pressures inside prosthetic sockets of lower-limb amputees in a simple and practical means of sensing. The liner is made of two silicone layers be...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.8.087001

    authors: Al-Fakih E,Arifin N,Pirouzi G,Mahamd Adikan FR,Shasmin HN,Abu Osman NA

    更新日期:2017-08-01 00:00:00

  • Near-ultraviolet removal rates for subgingival dental calculus at different irradiation angles.

    abstract::The laser ablation rate of subgingival dental calculus irradiated at a 400-nm-wavelength, 7.4-mJ pulse energy, and 85- and 20-deg irradiation angles is measured using laser triangulation. Three-dimensional images taken before and after irradiation create a removal map with 6-μm axial resolution. Fifteen human teeth wi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3564907

    authors: Schoenly JE,Seka WD,Rechmann P

    更新日期:2011-07-01 00:00:00

  • Applications of compressive sensing in spatial frequency domain imaging.

    abstract:SIGNIFICANCE:Spatial frequency domain imaging (SFDI) is an imaging modality that projects spatially modulated light patterns to determine optical property maps for absorption and reduced scattering of biological tissue via a pixel-by-pixel data acquisition and analysis procedure. Compressive sensing (CS) is a signal pr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.11.112904

    authors: Mellors BOL,Bentley A,Spear AM,Howle CR,Dehghani H

    更新日期:2020-11-01 00:00:00

  • Adaptive optics for fluorescence wide-field microscopy using spectrally independent guide star and markers.

    abstract::We describe the implementation and use of an adaptive optics loop in the imaging path of a commercial wide field microscope. We show that it is possible to maintain the optical performances of the original microscope when imaging through aberrant biological samples. The sources used for illuminating the adaptive optic...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3603847

    authors: Vermeulen P,Muro E,Pons T,Loriette V,Fragola A

    更新日期:2011-07-01 00:00:00

  • Dual/differential coherent anti-Stokes Raman scattering module for multiphoton microscopes with a femtosecond Ti:sapphire oscillator.

    abstract::In the last decade, coherent anti-Stokes Raman scattering (CARS) microscopy has emerged as a powerful multiphoton imaging technique offering label-free chemical sensitivity and high three-dimensional resolution. However, its widespread application in the life sciences has been hampered by the use of costly pulsed lase...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.6.066004

    authors: Li B,Borri P,Langbein W

    更新日期:2013-06-01 00:00:00

  • Photodynamic therapy: superficial and interstitial illumination.

    abstract::Photodynamic therapy (PDT) is reviewed using the treatment of skin tumors as an example of superficial lesions and prostate cancer as an example of deep-lying lesions requiring interstitial intervention. These two applications are among the most commonly studied in oncological PDT, and illustrate well the different ch...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3466579

    authors: Svanberg K,Bendsoe N,Axelsson J,Andersson-Engels S,Svanberg S

    更新日期:2010-07-01 00:00:00

  • Practicability and safety of laser-assisted reduction surgery.

    abstract::We have presented an innovative laser-assisted reduction surgery (LARS) based on plasma-induced ablation and photodisruption effects. In addition, we developed a laser operation system. Fetuses of mice from the Institute for Cancer Research that were immersed in physiological saline were irradiated by convergent-pulse...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.11.118002

    authors: Wang Y,Xiong Q,Ye Z,Ge J

    更新日期:2013-11-01 00:00:00

  • Multiplexed neural recording along a single optical fiber via optical reflectometry.

    abstract::We introduce the design and theoretical analysis of a fiber-optic architecture for neural recording without contrast agents, which transduces neural electrical signals into a multiplexed optical readout. Our sensor design is inspired by electro-optic modulators, which modulate the refractive index of a waveguide by ap...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.5.057003

    authors: Rodriques SG,Marblestone AH,Scholvin J,Dapello J,Sarkar D,Mankin M,Gao R,Wood L,Boyden ES

    更新日期:2016-05-01 00:00:00