Hyperspectral multiplex single-particle tracking of different receptor subtypes labeled with quantum dots in live neurons.

Abstract:

:The efficacy of existing therapies and the discovery of innovative treatments for central nervous system (CNS) diseases have been limited by the lack of appropriate methods to investigate complex molecular processes at the synaptic level. To improve our capability to investigate complex mechanisms of synaptic signaling and remodeling, we designed a fluorescence hyperspectral imaging platform to simultaneously track different subtypes of individual neurotransmitter receptors trafficking in and out of synapses. This imaging platform allows simultaneous image acquisition of at least five fluorescent markers in living neurons with a high-spatial resolution. We used quantum dots emitting at different wavelengths and functionalized to specifically bind to single receptors on the membrane of living neurons. The hyperspectral imaging platform enabled the simultaneous optical tracking of five different synaptic proteins, including subtypes of glutamate receptors (mGluR and AMPAR) and postsynaptic signaling proteins. It also permitted the quantification of their mobility after treatments with various pharmacological agents. This technique provides an efficient method to monitor several synaptic proteins at the same time, which could accelerate the screening of effective compounds for treatment of CNS disorders.

journal_name

J Biomed Opt

authors

Labrecque S,Sylvestre JP,Marcet S,Mangiarini F,Bourgoin B,Verhaegen M,Blais-Ouellette S,De Koninck P

doi

10.1117/1.JBO.21.4.046008

subject

Has Abstract

pub_date

2016-04-30 00:00:00

pages

46008

issue

4

eissn

1083-3668

issn

1560-2281

pii

2518011

journal_volume

21

pub_type

杂志文章
  • Quantitative analysis of angle-resolved scattering properties of ovarian tissue using optical coherence tomography.

    abstract::Angle-resolved optical scattering properties of ovarian tissue, on different optical coherence tomography (OCT) imaging planes, were quantitatively measured by fitting the compounded OCT A-lines into a single scattering model. Higher cross correlation value of angle-resolved scattering coefficients between different O...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.17.9.090503

    authors: Yang Y,Wang T,Brewer M,Zhu Q

    更新日期:2012-09-01 00:00:00

  • Evans blue dye-enhanced capillary-resolution photoacoustic microscopy in vivo.

    abstract::Complete and continuous imaging of microvascular networks is crucial for a wide variety of biomedical applications. Photoacoustic tomography can provide high resolution microvascular imaging using hemoglobin within red blood cells (RBCs) as an endogenic contrast agent. However, intermittent RBC flow in capillaries res...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3251044

    authors: Yao J,Maslov K,Hu S,Wang LV

    更新日期:2009-09-01 00:00:00

  • Effects of breast density and compression on normal breast tissue hemodynamics through breast tomosynthesis guided near-infrared spectral tomography.

    abstract::Optically derived tissue properties across a range of breast densities and the effects of breast compression on estimates of hemoglobin, oxygen metabolism, and water and lipid concentrations were obtained from a coregistered imaging system that integrates near-infrared spectral tomography (NIRST) with digital breast t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.9.091316

    authors: Michaelsen KE,Krishnaswamy V,Shi L,Vedantham S,Karellas A,Pogue BW,Paulsen KD,Poplack SP

    更新日期:2016-09-01 00:00:00

  • Surface plasmon-based infrared spectroscopy for cell biosensing.

    abstract::Cell morphology is often used as a valuable indicator of the physical condition and general status of living cells. We demonstrate a noninvasive method for morphological characterization of adherent cells. We measure infrared reflectivity spectrum at oblique angle from living cells cultured on thin Au film, and utiliz...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.081409

    authors: Yashunsky V,Lirtsman V,Zilbershtein A,Bein A,Schwartz B,Aroeti B,Golosovsky M,Davidov D

    更新日期:2012-08-01 00:00:00

  • Label-free optical activation of astrocyte in vivo.

    abstract::As the most abundant cell type in the central nervous system, astrocyte has been one of main research topics in neuroscience. Although various tools have been developed, at present, there is no tool that allows noninvasive activation of astrocyte in vivo without genetic or pharmacological perturbation. Here we report ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3600774

    authors: Choi M,Yoon J,Ku T,Choi K,Choi C

    更新日期:2011-07-01 00:00:00

  • Comparison of cerebral oxygen saturation in premature infants by near-infrared spatially resolved spectroscopy: observations on probe-dependent bias.

    abstract::Spatially resolved spectroscopy (SRS) allows the estimation of absolute tissue oxygen saturation, the ratio of oxygenated to total hemoglobin concentration, which may facilitate the comparison of results among patients. Eighty-two premature infants were included over two years. The cerebral tissue oxygenation index (c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3013454

    authors: Sorensen LC,Leung TS,Greisen G

    更新日期:2008-11-01 00:00:00

  • Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry.

    abstract::Optical spectroscopy, imaging, and therapy tissue phantoms must have the scattering and absorption properties that are characteristic of human tissues, and over the past few decades, many useful models have been created. In this work, an overview of their composition and properties is outlined, by separating matrix, s...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.2335429

    authors: Pogue BW,Patterson MS

    更新日期:2006-07-01 00:00:00

  • Measurement of retinal blood flow in the rat by combining Doppler Fourier-domain optical coherence tomography with fundus imaging.

    abstract::A wide variety of ocular diseases are associated with abnormalities in ocular circulation. As such, there is considerable interest in techniques for quantifying retinal blood flow, among which Doppler optical coherence tomography (OCT) may be the most promising. We present an approach to measure retinal blood flow in ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.106008

    authors: Werkmeister RM,Vietauer M,Knopf C,Fürnsinn C,Leitgeb RA,Reitsamer H,Gröschl M,Garhöfer G,Vilser W,Schmetterer L

    更新日期:2014-01-01 00:00:00

  • Handheld projective imaging device for near-infrared fluorescence imaging and intraoperative guidance of sentinel lymph node resection.

    abstract::We propose a handheld projective imaging device for orthotopic projection of near-infrared fluorescence images onto target biological tissue at visible wavelengths without any additional visual aid. The device integrates a laser diode light source module, a camera module, a projector, an ultrasonic distance sensor, a ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.8.080503

    authors: Li C,Liu P,Shao P,Pei J,Li Y,Pawlik TM,Martin EW,Xu RX

    更新日期:2019-08-01 00:00:00

  • Detecting glucose-induced changes in in vitro and in vivo experiments with optical coherence tomography.

    abstract::Optical clearing is a well-known phenomenon. It is based on the matching of refractive indices of a bulk material and scattering particles. The same principle is also used in scattering-based optical measurements of different constituents, such as glucose. By registering changes in scattering, it is possible to evalua...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2904957

    authors: Kinnunen M,Myllylä R,Vainio S

    更新日期:2008-03-01 00:00:00

  • Laser-ultraviolet-A-induced ultraweak photon emission in mammalian cells.

    abstract::Photobiological research in the last 30 yr has shown the existence of ultraweak photon emission in biological tissue, which can be detected with sophisticated photomultiplier systems. Although the emission of this ultraweak radiation, often termed biophotons, is extremely low in mammalian cells, it can be efficiently ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1899185

    authors: Niggli HJ,Tudisco S,Privitera G,Applegate LA,Scordino A,Musumeci F

    更新日期:2005-03-01 00:00:00

  • Chemical reactivation of fluorescein isothiocyanate immunofluorescence-labeled resin-embedded samples.

    abstract::Resin embedding is widely used and facilitates microscopic imaging of biological tissues. In contrast, quenching of fluorescence during embedding process hinders the application of resin embedding for imaging of fluorescence-labeled samples. For samples expressing fluorescent proteins, it has been demonstrated that th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.2.020501

    authors: Li L,Rao G,Lv X,Chen R,Cheng X,Wang X,Zeng S,Liu X

    更新日期:2018-02-01 00:00:00

  • Noninvasive assessment of diabetic foot ulcers with diffuse photon density wave methodology: pilot human study.

    abstract::A pilot human study is conducted to evaluate the potential of using diffuse photon density wave (DPDW) methodology at near-infrared (NIR) wavelengths (685 to 830 nm) to monitor changes in tissue hemoglobin concentration in diabetic foot ulcers. Hemoglobin concentration is measured by DPDW in 12 human wounds for a peri...

    journal_title:Journal of biomedical optics

    pub_type: 临床试验,杂志文章

    doi:10.1117/1.3275467

    authors: Papazoglou ES,Neidrauer M,Zubkov L,Weingarten MS,Pourrezaei K

    更新日期:2009-11-01 00:00:00

  • Fluidic lens laparoscopic zoom camera for minimally invasive surgery.

    abstract::This work reports a miniaturized laparoscopic zoom camera that can significantly improve vision for minimally invasive surgery (MIS), also known as laparoscopic surgery. The laparoscopic zoom camera contains bioinspired fluidic lenses that can change curvature and focal length in a manner similar to the crystalline le...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3420192

    authors: Tsai FS,Johnson D,Francis CS,Cho SH,Qiao W,Arianpour A,Mintz Y,Horgan S,Talamini M,Lo YH

    更新日期:2010-05-01 00:00:00

  • Study of the influence of over-the-counter vitamin supplement intake on urine fluorescence to optimize cancer detection by fluorescence cystoscopy.

    abstract::Fluorescence cystoscopy (FC) efficiently enhances the detection and improves the therapeutic management of early bladder cancer. During an FC, about 150 ml of water is needed to inflate the bladder. The water is quickly diluted by urine which can be fluorescent. If this bladder washout fluid (BWF) becomes fluorescent,...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.6.066011

    authors: Zellweger M,Martoccia C,Mengin M,Iselin C,van den Bergh H,Wagnières G

    更新日期:2015-06-01 00:00:00

  • In vivo photoacoustic imaging of major blood vessels in the pancreas and liver during surgery.

    abstract::Abdominal surgeries carry considerable risk of gastrointestinal and intra-abdominal hemorrhage, which could possibly cause patient death. Photoacoustic imaging is one solution to overcome this challenge by providing visualization of major blood vessels during surgery. We investigate the feasibility of in vivo blood ve...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.12.121905

    authors: Kempski KM,Wiacek A,Graham M,González E,Goodson B,Allman D,Palmer J,Hou H,Beck S,He J,Bell MAL

    更新日期:2019-08-01 00:00:00

  • Surgical lighting with contrast enhancement based on spectral reflectance comparison and entropy analysis.

    abstract::Surgical light is important for helping the surgeon easily identify specific tissues during an operation. We propose a spectral reflectance comparison model to optimize the light-emitting diode light spectrum in the operating room. An entropy evaluation method, meant specifically for surgical situations, was developed...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.10.105012

    authors: Shen J,Wang H,Wu Y,Li A,Chen C,Zheng Z

    更新日期:2015-10-01 00:00:00

  • Modulation of an optical needle's reflectivity alters the average photon path through scattering media.

    abstract::We introduce the concept of deliberate placement of absorbers to alter the average path of photons through tissue for a biomedical optical device. By changing the reflectivity of a needle that separates a source and detector, the average photon path through a turbid medium can be changed. Totally reflective needles ha...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2168167

    authors: Simonson P,D'Amico E,Gratton E

    更新日期:2006-01-01 00:00:00

  • Fiber optic biosensor for the detection of C-reactive protein and the study of protein binding kinetics.

    abstract::Application of a fiber optic biosensor (FOB) to the real-time investigation of the interaction kinetics between FITC-conjugated monoclonal sheep anti-human C-reactive protein (CRP) antibody and CRP isoforms on the surface of optical fiber is described. Recently, both the native pentameric CRP (pCRP), an acute phase pr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714029

    authors: Chou C,Hsu HY,Wu HT,Tseng KY,Chiou A,Yu CJ,Lee ZY,Chan TS

    更新日期:2007-03-01 00:00:00

  • Oral cancer screening: serum Raman spectroscopic approach.

    abstract::Serum Raman spectroscopy (RS) has previously shown potential in oral cancer diagnosis and recurrence prediction. To evaluate the potential of serum RS in oral cancer screening, premalignant and cancer-specific detection was explored in the present study using 328 subjects belonging to healthy controls, premalignant, d...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.11.115006

    authors: Sahu AK,Dhoot S,Singh A,Sawant SS,Nandakumar N,Talathi-Desai S,Garud M,Pagare S,Srivastava S,Nair S,Chaturvedi P,Murali Krishna C

    更新日期:2015-11-01 00:00:00

  • Using ultrahigh sensitive optical microangiography to achieve comprehensive depth resolved microvasculature mapping for human retina.

    abstract::This paper presents comprehensive and depth-resolved retinal microvasculature images within human retina achieved by a newly developed ultrahigh sensitive optical microangiography (UHS-OMAG) system. Due to its high flow sensitivity, UHS-OMAG is much more sensitive to tissue motion due to the involuntary movement of th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3642638

    authors: An L,Shen TT,Wang RK

    更新日期:2011-10-01 00:00:00

  • Mapping local optical axis in birefringent samples using polarization-sensitive optical coherence tomography.

    abstract::An algorithm was developed to obtain depth-resolved local optical axis in birefringent samples by using conventional polarization-sensitive optical coherence tomography (PSOCT) that uses a single circularly polarized incident light. The round-trip sample Jones matrices were first constructed from the cumulative PSOCT ...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.17.11.110501

    authors: Fan C,Yao G

    更新日期:2012-11-01 00:00:00

  • Characterizing depth-dependent refractive index of articular cartilage subjected to mechanical wear or enzymic degeneration.

    abstract::Utilizing a laser scanning confocal microscope system, the refractive indices of articular cartilage (AC) with mechanical or biochemical degenerations were characterized to investigate whether potential correlations exist between refractive index (RI) and cartilage degeneration. The cartilage samples collected from th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.9.095002

    authors: Wang K,Wu J,Day R,Kirk TB,Hu X

    更新日期:2016-09-01 00:00:00

  • Neural networks improve brain cancer detection with Raman spectroscopy in the presence of operating room light artifacts.

    abstract::Invasive brain cancer cells cannot be visualized during surgery and so they are often not removed. These residual cancer cells give rise to recurrences.

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.9.094002

    authors: Jermyn M,Desroches J,Mercier J,Tremblay MA,St-Arnaud K,Guiot MC,Petrecca K,Leblond F

    更新日期:2016-09-01 00:00:00

  • In vivo photoacoustic imaging of mouse embryos.

    abstract::The ability to noninvasively image embryonic vascular anatomy in mouse models is an important requirement for characterizing the development of the normal cardiovascular system and malformations in the heart and vascular supply. Photoacoustic imaging, which can provide high resolution non invasive images of the vascul...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.6.061220

    authors: Laufer J,Norris F,Cleary J,Zhang E,Treeby B,Cox B,Johnson P,Scambler P,Lythgoe M,Beard P

    更新日期:2012-06-01 00:00:00

  • Pulsed photoacoustic flow imaging with a handheld system.

    abstract::Flow imaging is an important technique in a range of disease areas, but estimating low flow speeds, especially near the walls of blood vessels, remains challenging. Pulsed photoacoustic flow imaging can be an alternative since there is little signal contamination from background tissue with photoacoustic imaging. We p...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.2.026004

    authors: van den Berg PJ,Daoudi K,Steenbergen W

    更新日期:2016-02-01 00:00:00

  • Lamellar keratoplasty using position-guided surgical needle and M-mode optical coherence tomography.

    abstract::Deep anterior lamellar keratoplasty (DALK) is an emerging surgical technique for the restoration of corneal clarity and vision acuity. The big-bubble technique in DALK surgery is the most essential procedure that includes the air injection through a thin syringe needle to separate the dysfunctional region of the corne...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.12.125005

    authors: Shin S,Bae JK,Ahn Y,Kim H,Choi G,Yoo YS,Joo CK,Moon S,Jung W

    更新日期:2017-12-01 00:00:00

  • Multispectral in vivo three-dimensional optical coherence tomography of human skin.

    abstract::The capability of optical coherence tomography (OCT) to perform "optical biopsy" of tissues within a depth range of 1 to 2 mm with micron-scale resolution in real time makes it a promising biomedical imaging modality for dermatologic applications. Three high-speed, spectrometer-based frequency-domain OCT systems opera...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3400665

    authors: Alex A,Povazay B,Hofer B,Popov S,Glittenberg C,Binder S,Drexler W

    更新日期:2010-03-01 00:00:00

  • High-spatial-resolution deep tissue imaging with spectral-domain optical coherence microscopy in the 1700-nm spectral band.

    abstract::We present three-dimensional (3-D) high-resolution spectral-domain optical coherence microscopy (SD-OCM) by using a supercontinuum (SC) fiber laser source with 300-nm spectral bandwidth (full-width at half-maximum) in the 1700-nm spectral band. By using low-coherence interferometry with SC light and a confocal detecti...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.7.070502

    authors: Yamanaka M,Hayakawa N,Nishizawa N

    更新日期:2019-07-01 00:00:00

  • Quantitative concentration measurements of creatinine dissolved in water and urine using Raman spectroscopy and a liquid core optical fiber.

    abstract::We describe the use of a Teflon-AF liquid core optical fiber (LCOF) geometry to enhance the collection of Raman scattering from the biochemical creatinine, dissolved in water and in urine. At short integration times, where shot noise is most troublesome, the enhanced signal leads to greater accuracy in estimating the ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1917842

    authors: Qi D,Berger AJ

    更新日期:2005-05-01 00:00:00