Evidence of a heterogeneous tissue oxygenation: renal ischemia/reperfusion injury in a large animal model.

Abstract:

:Renal ischemia that occurs intraoperatively during procedures requiring clamping of the renal artery (such as renal procurement for transplantation and partial nephrectomy for renal cancer) is known to have a significant impact on the viability of that kidney. To better understand the dynamics of intraoperative renal ischemia and recovery of renal oxygenation during reperfusion, a visible reflectance imaging system (VRIS) was developed to measure renal oxygenation during renal artery clamping in both cooled and warm porcine kidneys. For all kidneys, normothermic and hypothermic, visible reflectance imaging demonstrated a spatially distinct decrease in the relative oxy-hemoglobin concentration (%HbO₂) of the superior pole of the kidney compared to the middle or inferior pole. Mean relative oxy-hemoglobin concentrations decrease more significantly during ischemia for normothermic kidneys compared to hypothermic kidneys. VRIS may be broadly applicable to provide an indicator of organ ischemia during open and laparoscopic procedures.

journal_name

J Biomed Opt

authors

Crane NJ,Huffman SW,Alemozaffar M,Gage FA,Levin IW,Elster EA

doi

10.1117/1.JBO.18.3.035001

subject

Has Abstract

pub_date

2013-03-01 00:00:00

pages

035001

issue

3

eissn

1083-3668

issn

1560-2281

pii

1658061

journal_volume

18

pub_type

杂志文章
  • Measurement and imaging of birefringent properties of the human cornea with phase-resolved, polarization-sensitive optical coherence tomography.

    abstract::Optical coherence tomography (OCT) is an emerging technology for high-resolution, noncontact imaging of transparent and scattering media. Polarization-sensitive optical coherence tomography (PS-OCT) is a functional extension of OCT that can image birefringent properties of a biological sample. PS-OCT was used to measu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1629308

    authors: Götzinger E,Pircher M,Sticker M,Fercher AF,Hitzenberger CK

    更新日期:2004-01-01 00:00:00

  • Fast spatiotemporal image reconstruction based on low-rank matrix estimation for dynamic photoacoustic computed tomography.

    abstract::In order to monitor dynamic physiological events in near-real time, a variety of photoacoustic computed tomography (PACT) systems have been developed that can rapidly acquire data. Previously reported studies of dynamic PACT have employed conventional static methods to reconstruct a temporally ordered sequence of imag...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.5.056007

    authors: Wang K,Xia J,Li C,Wang LV,Anastasio MA

    更新日期:2014-05-01 00:00:00

  • Detection of Plasmodium falciparum-infected red blood cells by optical stretching.

    abstract::We present the application of a microfluidic optical cell stretcher to measure the elasticity of malaria-infected red blood cells. The measurements confirm an increase in host cell rigidity during the maturation of the parasite Plasmodium falciparum. The device combines the selectivity and sensitivity of single-cell e...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3458919

    authors: Mauritz JM,Tiffert T,Seear R,Lautenschläger F,Esposito A,Lew VL,Guck J,Kaminski CF

    更新日期:2010-05-01 00:00:00

  • Deep learning-level melanoma detection by interpretable machine learning and imaging biomarker cues.

    abstract:SIGNIFICANCE:Melanoma is a deadly cancer that physicians struggle to diagnose early because they lack the knowledge to differentiate benign from malignant lesions. Deep machine learning approaches to image analysis offer promise but lack the transparency to be widely adopted as stand-alone diagnostics. AIM:We aimed to...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.11.112906

    authors: Gareau DS,Browning J,Correa Da Rosa J,Suarez-Farinas M,Lish S,Zong AM,Firester B,Vrattos C,Renert-Yuval Y,Gamboa M,Vallone MG,Barragán-Estudillo ZF,Tamez-Peña AL,Montoya J,Jesús-Silva MA,Carrera C,Malvehy J,Puig S,Mar

    更新日期:2020-11-01 00:00:00

  • Design of synchrotron light source and its beamline dedicated to dual-energy x-ray computed tomography.

    abstract::A synchrotron light source dedicated to medical applications has been designed at National Institute of Radiological Sciences. The storage ring, with circumference of 80 m, is designed for acceleration of 2.3 GeV and a stored current of 420 mA. It is equipped with two multipole wigglers to produce sufficient photon fl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1383062

    authors: Torikoshi M,Tsunoo T,Endo M,Noda K,Kumada M,Yamada S,Soga F,Hyodo K

    更新日期:2001-07-01 00:00:00

  • Estimation of subcellular particle size histograms with electron microscopy for prediction of optical scattering in breast tissue.

    abstract::Diffuse near-infrared tomography of tissue reveals scattering changes that originate from the submicroscopic features of the tissue; yet the existing tools to use this information to predict which features contribute to the scattering spectrum are limited by the lack of direct data quantifying the particle sizes. Brea...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2398903

    authors: Bartek M,Wang X,Wells W,Paulsen KD,Pogue BW

    更新日期:2006-11-01 00:00:00

  • Comparison of motion correction techniques applied to functional near-infrared spectroscopy data from children.

    abstract::Motion artifacts are the most significant sources of noise in the context of pediatric brain imaging designs and data analyses, especially in applications of functional near-infrared spectroscopy (fNIRS), in which it can completely affect the quality of the data acquired. Different methods have been developed to corre...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.12.126003

    authors: Hu XS,Arredondo MM,Gomba M,Confer N,DaSilva AF,Johnson TD,Shalinsky M,Kovelman I

    更新日期:2015-01-01 00:00:00

  • Coregistered optical coherence tomography and frequency-encoded multispectral imaging for spectrally sparse color imaging.

    abstract::We present a system combining optical coherence tomography (OCT) and multispectral imaging (MSI) for coregistered structural imaging and surface color imaging. We first describe and numerically validate an optimization model to guide the selection of the MSI wavelengths and their relative intensities. We then demonstr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.3.032008

    authors: Attendu X,Bourget MH,de Sivry-Houle MP,Boudoux C

    更新日期:2019-11-01 00:00:00

  • Spatially resolved reflectance spectroscopy for diagnosis of cervical precancer: Monte Carlo modeling and comparison to clinical measurements.

    abstract::We present Monte Carlo modeling studies to provide a quantitative understanding of contrast observed in spatially resolved reflectance spectra of normal and highly dysplastic cervical tissue. Simulations have been carried out to analyze the sensitivity of spectral measurements to a range of changes in epithelial and s...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2398932

    authors: Arifler D,MacAulay C,Follen M,Richards-Kortum R

    更新日期:2006-11-01 00:00:00

  • In vivo near-infrared dual-axis confocal microendoscopy in the human lower gastrointestinal tract.

    abstract::Near-infrared confocal microendoscopy is a promising technique for deep in vivo imaging of tissues and can generate high-resolution cross-sectional images at the micron-scale. We demonstrate the use of a dual-axis confocal (DAC) near-infrared fluorescence microendoscope with a 5.5-mm outer diameter for obtaining clini...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.2.021102

    authors: Piyawattanametha W,Ra H,Qiu Z,Friedland S,Liu JT,Loewke K,Kino GS,Solgaard O,Wang TD,Mandella MJ,Contag CH

    更新日期:2012-02-01 00:00:00

  • Imaging performance of a miniature integrated microendoscope.

    abstract::An integrated miniature multi-modal microscope (4M device) for microendoscopy was built and tested. Imaging performance is evaluated and imaging results are presented for both fluorescence and reflectance samples. Images of biological samples show successful imaging of both thin layers of fixed cells prepared on a sli...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2978060

    authors: Rogers JD,Landau S,Tkaczyk TS,Descour MR,Rahman MS,Richards-Kortum R,Kärkäinen AH,Christenson T

    更新日期:2008-09-01 00:00:00

  • Combined anatomical optical coherence tomography and intraluminal pressure reveal viscoelasticity of the in vivo airway.

    abstract::It is hypothesized that the local, viscoelastic (time-dependent) properties of the airway are important to accurately model and ultimately predict dynamic airway collapse in airway obstruction. Toward this end, we present a portable, endoscopic, swept-source anatomical optical coherence tomography (aOCT) system combin...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.23.10.100501

    authors: Balakrishnan S,Bu R,Iftimia N,Price H,Zdanski C,Oldenburg AL

    更新日期:2018-10-01 00:00:00

  • Autofluorescence of epithelial tissue: single-photon versus two-photon excitation.

    abstract::We instrumented a combined fluorescence spectroscopy and imaging system to characterize the single- and two-photon excited autofluorescence in epithelial tissue. Single-photon fluorescence (SPF) are compared with two-photon fluorescence (TPF) measured at the same location in epithelial tissue. It was found that the SP...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2975866

    authors: Zheng W,Wu Y,Li D,Qu JY

    更新日期:2008-09-01 00:00:00

  • Measurement of optical path length change following pulsed laser irradiation using differential phase optical coherence tomography.

    abstract::Differential phase optical coherence tomography (DPOCT) is introduced to measure optical path length changes in response to pulsed laser irradiation (585 nm). An analytical equation that includes thermoelastic surface displacement and thermorefractive index change is derived to predict optical path length change in re...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2236289

    authors: Kim J,Oh J,Milner TE

    更新日期:2006-07-01 00:00:00

  • Preclinical evidence of mitochondrial nicotinamide adenine dinucleotide as an effective alarm parameter under hypoxia.

    abstract::Early detection of tissue hypoxia in the intensive care unit is essential for effective treatment. Reduced nicotinamide adenine dinucleotide (NADH) has been suggested to be the most sensitive indicator of tissue oxygenation at the mitochondrial level. However, no experimental evidence comparing the kinetics of changes...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.1.017005

    authors: Shi H,Sun N,Mayevsky A,Zhang Z,Luo Q

    更新日期:2014-01-01 00:00:00

  • Variations in the endogenous fluorescence of rabbit corneas after mechanical property alterations.

    abstract::Keratoconus is an eye disease in which the cornea progressively deforms due to loss of cornea mechanical rigidity, and thus causes deterioration of visual acuity. Techniques to characterize the mechanical characteristics of the cornea are important to better monitor changes and response to treatments. To investigate t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.9.095005

    authors: Ortega-Martinez A,Touchette G,Zhu H,Kochevar IE,Franco W

    更新日期:2017-09-01 00:00:00

  • Optical properties of adenocarcinoma and squamous cell carcinoma of the gastroesophageal junction.

    abstract::Photodynamic therapy (PDT) is an alternative to radical surgical resection for T1a or nonresectable carcinomas of the gastroesophageal junction. Besides the concentration of the photosensitizer, the light distribution in tissue is responsible for tumor destruction. For this reason, knowledge about the behavior of ligh...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2564793

    authors: Holmer C,Lehmann KS,Wanken J,Reissfelder C,Roggan A,Mueller G,Buhr HJ,Ritz JP

    更新日期:2007-01-01 00:00:00

  • Moving-source elastic wave reconstruction for high-resolution optical coherence elastography.

    abstract::Optical coherence tomography (OCT)-based elasticity imaging can map soft tissue elasticity based on speckle-tracking of elastic wave propagation using highly sensitive phase measurements of OCT signals. Using a fixed elastic wave source and moving detection, current imaging sequences have difficulty in reconstructing ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.11.116006

    authors: Hsieh BY,Song S,Nguyen TM,Yoon SJ,Shen TT,Wang RK,O'Donnell M

    更新日期:2016-11-01 00:00:00

  • Real-time full-field photoacoustic imaging using an ultrasonic camera.

    abstract::A photoacoustic imaging system that incorporates a commercial ultrasonic camera for real-time imaging of two-dimensional (2-D) projection planes in tissue at video rate (30 Hz) is presented. The system uses a Q-switched frequency-doubled Nd:YAG pulsed laser for photoacoustic generation. The ultrasonic camera consists ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3420079

    authors: Balogun O,Regez B,Zhang HF,Krishnaswamy S

    更新日期:2010-03-01 00:00:00

  • Comparison of spectroscopically measured tissue alcohol concentration to blood and breath alcohol measurements.

    abstract::Alcohol testing is an expanding area of interest due to the impacts of alcohol abuse that extend well beyond drunk driving. However, existing approaches such as blood and urine assays are hampered in some testing environments by biohazard risks. A noninvasive, in vivo spectroscopic technique offers a promising alterna...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3253353

    authors: Ridder TD,Ver Steeg BJ,Laaksonen BD

    更新日期:2009-09-01 00:00:00

  • Comparison of laser and diode sources for acceleration of in vitro wound healing by low-level light therapy.

    abstract::Low-level light therapy has been shown to improve in vitro wound healing. However, well-defined parameters of different light sources for this therapy are lacking. The goal of this study was (1) to determine if the wavelengths tested are effective for in vitro wound healing and (2) to compare a laser and a light-emitt...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.3.038001

    authors: Spitler R,Berns MW

    更新日期:2014-03-01 00:00:00

  • Optical pH measurement system using a single fluorescent dye for assessing susceptibility to dental caries.

    abstract::Sugar-rich diets and poor dental hygiene promote the formation of a biofilm (plaque) that strongly adheres to the dental enamel surface and fosters the evolution of aciduric bacteria. The acid contributes to demineralization of the exterior tooth enamel, which accelerates after the pH drops below a critical value (∼5....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.1.017001

    authors: Sharma M,Graham JY,Walczak PA,Nguyen R,Lee LK,Carson MD,Nelson LY,Patel SN,Xu Z,Seibel EJ

    更新日期:2019-01-01 00:00:00

  • Nondestructive imaging of fiber structure in articular cartilage using optical polarization tractography.

    abstract::Collagen fiber orientation plays an important role in determining the structure and function of the articular cartilage. However, there is currently a lack of nondestructive means to image the fiber orientation from the cartilage surface. The purpose of this study is to investigate whether the newly developed optical ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.11.116004

    authors: Yao X,Wang Y,Ravanfar M,Pfeiffer FM,Duan D,Yao G

    更新日期:2016-11-01 00:00:00

  • Measurement of the refractive index of whole blood and its components for a continuous spectral region.

    abstract::The refractive index of blood is a key biophysical parameter, which can reflect the physiological state. We measured the refractive index of whole blood and other components, such as serum, plasma, and hemoglobin, based on internal reflection by using a homemade apparatus in the spectral range of 400 to 750 nm. In add...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.3.035003

    authors: Liu S,Deng Z,Li J,Wang J,Huang N,Cui R,Zhang Q,Mei J,Zhou W,Zhang C,Ye Q,Tian J

    更新日期:2019-03-01 00:00:00

  • Evaluating the use of optical coherence tomography for the detection of epithelial cancers in vitro.

    abstract::Optical coherence tomography (OCT) is a noninvasive imaging methodology that is able to image tissue to depths of over 1 mm. Many epithelial conditions, such as melanoma and oral cancers, require an invasive biopsy for diagnosis. A noninvasive, real-time, point of care method of imaging depth-resolved epithelial struc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3652708

    authors: Smith LE,Hearnden V,Lu Z,Smallwood R,Hunter KD,Matcher SJ,Thornhill MH,Murdoch C,MacNeil S

    更新日期:2011-11-01 00:00:00

  • Review of clinical approaches in fluorescence lifetime imaging ophthalmoscopy.

    abstract::Autofluorescence-based imaging techniques have become very important in the ophthalmological field. Being noninvasive and very sensitive, they are broadly used in clinical routines. Conventional autofluorescence intensity imaging is largely influenced by the strong fluorescence of lipofuscin, a fluorophore that can be...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.23.9.091415

    authors: Sauer L,Andersen KM,Dysli C,Zinkernagel MS,Bernstein PS,Hammer M

    更新日期:2018-09-01 00:00:00

  • Myocardial tissue oxygenation estimated with calibrated diffuse reflectance spectroscopy during coronary artery bypass grafting.

    abstract::We present a study using a method able to assess tissue oxygenation, taking into account the absorption and the level of scattering in myocardial tissue using a calibrated fiber optic probe. With this method, interindividual comparisons of oxygenation can be made despite varying tissue optical properties during corona...

    journal_title:Journal of biomedical optics

    pub_type: 临床试验,杂志文章

    doi:10.1117/1.2976433

    authors: Häggblad E,Lindbergh T,Karlsson MG,Casimir-Ahn H,Salerud EG,Strömberg T

    更新日期:2008-09-01 00:00:00

  • Mid-infrared laser measurements of aqueous glucose.

    abstract::Mid-IR semiconductor lasers of two wavelength bands, 5.4 and 9.6 microm, are applied to measure aqueous glucose concentration ranging from 0 to 500 mgdL with Intralipid emulsion (0 to 8%) added as a fat simulator. The absorption coefficient micro(a) is found linear with respect to glucose and Intralipid concentrations...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714283

    authors: Guo B,Wang Y,Wang Y,Le HQ

    更新日期:2007-03-01 00:00:00

  • Photoacoustic tomography of ex vivo mouse hearts with myocardial infarction.

    abstract::In the present study, we evaluated the applicability of ex vivo photoacoustic imaging (PAI) on small animal organs. We used photoacoustic tomography (PAT) to visualize infarcted areas within murine hearts and compared these data to other imaging techniques [magnetic resonance imaging (MRI), micro-computed tomography] ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3556720

    authors: Holotta M,Grossauer H,Kremser C,Torbica P,Völkl J,Degenhart G,Esterhammer R,Nuster R,Paltauf G,Jaschke W

    更新日期:2011-03-01 00:00:00

  • Detection of canine skin and subcutaneous tumors by visible and near-infrared diffuse reflectance spectroscopy.

    abstract::Cancer is the main cause of canine morbidity and mortality. The existing evaluation of tumors requires an experienced veterinarian and usually includes invasive procedures (e.g., fine-needle aspiration) that can be unpleasant for the dog and the owner. We investigate visible and near-infrared diffuse reflectance spect...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.3.037003

    authors: Cugmas B,Plavec T,Bregar M,Naglič P,Pernuš F,Likar B,Bürmen M

    更新日期:2015-03-01 00:00:00