Abstract:
:We introduce the design and theoretical analysis of a fiber-optic architecture for neural recording without contrast agents, which transduces neural electrical signals into a multiplexed optical readout. Our sensor design is inspired by electro-optic modulators, which modulate the refractive index of a waveguide by applying a voltage across an electro-optic core material. We estimate that this design would allow recording of the activities of individual neurons located at points along a 10-cm length of optical fiber with 40-μm axial resolution and sensitivity down to 100 μV using commercially available optical reflectometers as readout devices. Neural recording sites detect a potential difference against a reference and apply this potential to a capacitor. The waveguide serves as one of the plates of the capacitor, so charge accumulation across the capacitor results in an optical effect. A key concept of the design is that the sensitivity can be improved by increasing the capacitance. To maximize the capacitance, we utilize a microscopic layer of material with high relative permittivity. If suitable materials can be found—possessing high capacitance per unit area as well as favorable properties with respect to toxicity, optical attenuation, ohmic junctions, and surface capacitance—then such sensing fibers could, in principle, be scaled down to few-micron cross-sections for minimally invasive neural interfacing. We study these material requirements and propose potential material choices. Custom-designed multimaterial optical fibers, probed using a reflectometric readout, may, therefore, provide a powerful platform for neural sensing.
journal_name
J Biomed Optjournal_title
Journal of biomedical opticsauthors
Rodriques SG,Marblestone AH,Scholvin J,Dapello J,Sarkar D,Mankin M,Gao R,Wood L,Boyden ESdoi
10.1117/1.JBO.21.5.057003subject
Has Abstractpub_date
2016-05-01 00:00:00pages
57003issue
5eissn
1083-3668issn
1560-2281pii
2524865journal_volume
21pub_type
杂志文章abstract::The Nikon C1 confocal laser scanning microscope is a relatively inexpensive and user-friendly instrument. We describe a straightforward method to convert the C1 for multiphoton microscopy utilizing direct coupling of a femtosecond near-infrared laser into the scan head and fiber optic transmission of emission light to...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3139850
更新日期:2009-05-01 00:00:00
abstract::Functional near-infrared spectroscopy is prone to contamination by motion artifacts (MAs). Motion correction algorithms have previously been proposed and their respective performance compared for evoked rain activation studies. We study instead the effect of MAs on "oscillation" data which is at the basis of functiona...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.5.056011
更新日期:2015-05-01 00:00:00
abstract::Optical-resolution photoacoustic microscopy (ORPAM) in theory provides lateral resolution equivalent to the optical diffraction limit. Scattering media, such as biological turbid media, attenuates the optical signal and also alters the diffraction-limited spot size of the focused beam. The ORPAM signal is generated on...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.12.121202
更新日期:2015-12-01 00:00:00
abstract::Functional near-infrared spectroscopy (fNIRS), acquired simultaneously with electroencephalography (EEG), allows the investigation of hemodynamic brain responses to epileptic activity. Because the presumed epileptogenic focus is patient-specific, an appropriate source/detector (SD) montage has to be reconfigured for e...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.19.2.026010
更新日期:2014-02-01 00:00:00
abstract::A Fourier transform spectrometer is used to simultaneously measure distance, dispersion and spectrum. It is shown that short coherence interferometry has the potential to measure the three-dimensional distribution of the spatial structure of a sample with a resolution determined by the coherence length of the light so...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.429885
更新日期:1998-01-01 00:00:00
abstract::We report noninvasive, in vivo optical imaging deep within a mouse brain by swept-source optical coherence tomography (SS-OCT), enabled by a 1.3-μm vertical cavity surface emitting laser (VCSEL). VCSEL SS-OCT offers a constant signal sensitivity of 105 dB throughout an entire depth of 4.25 mm in air, ensuring an exten...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.10.106004
更新日期:2015-10-01 00:00:00
abstract::We investigate a technology to create a high temperature heat source on the tip surface of the glass fiber proposed for medical surgery applications. Using 4 to 6 W power level semiconductor lasers at a wavelength of 980 nm, a laser coupled fiber tip was preprocessed to contain a certain amount of titanium oxide powde...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.19.10.101502
更新日期:2014-01-01 00:00:00
abstract::Photodynamic therapy (PDT) is an alternative cancer treatment modality that offers localized treatment using a photosensitizer and light. However, tumor angiogenesis is a major concern following PDT-induced hypoxia as it promotes recurrence. Bevacizumab is a monoclonal antibody that targets vascular endothelial growth...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3281671
更新日期:2010-01-01 00:00:00
abstract::We propose a handheld projective imaging device for orthotopic projection of near-infrared fluorescence images onto target biological tissue at visible wavelengths without any additional visual aid. The device integrates a laser diode light source module, a camera module, a projector, an ultrasonic distance sensor, a ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.24.8.080503
更新日期:2019-08-01 00:00:00
abstract::Mid-IR semiconductor lasers of two wavelength bands, 5.4 and 9.6 microm, are applied to measure aqueous glucose concentration ranging from 0 to 500 mgdL with Intralipid emulsion (0 to 8%) added as a fat simulator. The absorption coefficient micro(a) is found linear with respect to glucose and Intralipid concentrations...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2714283
更新日期:2007-03-01 00:00:00
abstract::We present a novel confocal microscope that has dual-axis architecture and biaxial postobjective scanning for the collection of fluorescence images from biological specimens. This design uses two low-numerical-aperture lenses to achieve high axial resolution and long working distance, and the scanning mirror located d...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1760760
更新日期:2004-07-01 00:00:00
abstract::High resolution is important for sensitive detection of subtle distortions of retinal morphology at an early stage of eye diseases. We demonstrate virtually structured detection (VSD) as a feasible method to achieve in vivo super-resolution ophthalmoscopy. A line-scanning strategy was employed to achieve a super-resol...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.12.120502
更新日期:2016-12-01 00:00:00
abstract::Fluorescent proteins and dyes are routine tools for biological research to describe the behavior of genes, proteins, and cells, as well as more complex physiological dynamics such as vessel permeability and pharmacokinetics. The use of these probes in whole body in vivo imaging would allow extending the range and scop...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.2.026009
更新日期:2016-02-01 00:00:00
abstract::Given the several difficulties associated with histology, including difficulty in continuous monitoring, this study aimed to investigate the feasibility of optical imaging modalities—cross-polarization color (CPC) imaging, erythema index (EI) imaging, and laser speckle contrast (LSC) imaging—for continuous evaluation ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.19.10.106010
更新日期:2014-01-01 00:00:00
abstract::We investigate and assess the utility of a simple scheme for continuous absolute blood flow monitoring based on diffuse correlation spectroscopy (DCS). The scheme calibrates DCS using venous-occlusion diffuse optical spectroscopy (VO-DOS) measurements of arm muscle tissue at a single time-point. A calibration coeffici...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.12.125005
更新日期:2015-01-01 00:00:00
abstract::The results of an experimental study of the possibilities of monitoring erbium yttrium aluminum garnet laser-mediated ablation of human epidermis with the use of Fourier transform infrared (FTIR) spectroscopy and spectral polarization techniques are presented. The attenuated total reflection (ATR) method was used for ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1755719
更新日期:2004-07-01 00:00:00
abstract::We present a new detection instrument for sensor measurements based on excited-state fluorescence lifetimes. This system consists of a primary optoelectronic loop containing a resonance-type rf amplifier, a modulatable fluorescence-excitation light source, a fiber optic feedback loop (with a gap for a fluorescent sens...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1688814
更新日期:2004-05-01 00:00:00
abstract::Recently, it was shown in measurements carried out on humans that time-resolved near-infrared reflectometry and fluorescence spectroscopy may allow for discrimination of information originating directly from the brain avoiding influence of contaminating signals related to the perfusion of extracerebral tissues. We rep...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3574018
更新日期:2011-04-01 00:00:00
abstract::We present three-dimensional (3-D) high-resolution spectral-domain optical coherence microscopy (SD-OCM) by using a supercontinuum (SC) fiber laser source with 300-nm spectral bandwidth (full-width at half-maximum) in the 1700-nm spectral band. By using low-coherence interferometry with SC light and a confocal detecti...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.24.7.070502
更新日期:2019-07-01 00:00:00
abstract::By applying linear perturbation theory to the radiation transport equation, the inverse problem of optical diffusion tomography can be reduced to a set of linear equations, Wμ=R, where W is the weight function, μ are the cross-section perturbations to be imaged, and R is the detector readings perturbations. We have st...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.429870
更新日期:1998-04-01 00:00:00
abstract::Complete and continuous imaging of microvascular networks is crucial for a wide variety of biomedical applications. Photoacoustic tomography can provide high resolution microvascular imaging using hemoglobin within red blood cells (RBCs) as an endogenic contrast agent. However, intermittent RBC flow in capillaries res...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3251044
更新日期:2009-09-01 00:00:00
abstract::We demonstrate that using time-resolved two-photon excitation endogenous fluorescence microscopy, the cadmium (Cd)-induced cellular toxic level can be assessed by the free-to protein-bound reduced nicotinamide adenine dinucleotide (free/bound NADH) ratio in a living cell. NADH fluorescence excited at 730 nm is capture...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3250293
更新日期:2009-09-01 00:00:00
abstract::The study of red blood cell (RBC) aggregation is of great interest because of its implications for human health. Altered RBC aggregation can lead to microcirculatory problems as in vascular pathologies, such as hypertension and diabetes, due to a decrease in the erythrocyte surface electric charge and an increase in t...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.22.1.017003
更新日期:2017-01-01 00:00:00
abstract::High-speed (video-rate) fluorescence lifetime imaging (FLIM) through a flexible endoscope is reported based on gated optical image intensifier technology. The optimization and potential application of FLIM to tissue autofluorescence for clinical applications are discussed. ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2102807
更新日期:2005-09-01 00:00:00
abstract::We demonstrate the utility of functional near-infrared spectroscopy (fNIRS) as a tool for physicians to study cortical plasticity in children with cerebral palsy (CP). Motor cortex activation patterns were studied in five healthy children and five children with CP (8.4+/-2.3 years old in both groups) performing a fing...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3432746
更新日期:2010-05-01 00:00:00
abstract::Intraductal carcinoma is a precancerous lesion of the breast and the immediate precursor of invasive ductal carcinoma. Multiphoton microscopy (MPM) was used to monitor the progression from intraductal carcinoma to invasive ductal carcinoma, which can improve early detection of precursor lesions and halt progression to...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.9.096007
更新日期:2015-09-01 00:00:00
abstract::The attenuation of near-infrared (NIR) light intensity as it propagates in a turbid medium like biological tissue is described by modified the Beer–Lambert law (MBLL). The MBLL is generally used to quantify the changes in tissue chromophore concentrations for NIR spectroscopic data analysis. Even though MBLL is effect...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.7.076012
更新日期:2016-07-01 00:00:00
abstract::The spatiotemporal characteristics of changes in cerebral blood volume associated with neuronal activity were investigated in the hindlimb somatosensory cortex of alpha-chloralose-urethane anesthetized rats (n=10) with optical imaging at 570 nm through a thinned skull. Activation of the cortex was carried out by elect...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1609199
更新日期:2003-10-01 00:00:00
abstract::Clustering analysis (CA) and principal component analysis (PCA) were applied to dynamic Cerenkov luminescence images (dCLI). In order to investigate the performances of the proposed approaches, two distinct dynamic data sets obtained by injecting mice with (32)P-ATP and (18)F-FDG were acquired using the IVIS 200 optic...
journal_title:Journal of biomedical optics
pub_type: 信件
doi:10.1117/1.3663442
更新日期:2011-12-01 00:00:00
abstract::The potential of intrinsic optical imaging and resting-state analysis under anesthetized conditions as a tool to study brain networks associated with epileptic seizures is investigated. Using an acute model of epileptiform activity, the 4-aminopyridine model in live mice, we observe the changes in resting-state networ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.7.076021
更新日期:2013-07-01 00:00:00