Self-mixing in a diode laser as a method for cardiovascular diagnostics.

Abstract:

:Our aim is the development of a simple optical method for pulse wave profile, pulse wave delay time, and blood flow measurement. The method is based on recording the Doppler frequency shift related to a moving target--blood vessel walls or small particles. The Doppler signal is detected using the self-mixing that occurs in the diode laser cavity when radiation scatters back from the moving target into the laser and interferes with the field inside. Two different ways can be simultaneously used for the self-mixing signal extraction: a photodiode accommodated in the rear facet of the diode laser package and a resistor from the laser pump current. An experimental device with a pigtail laser diode is developed that is able to detect the pulsation of major arteries with potentially useful information, including the pulse wave profile and the pulse wave delay time. The pulse wave delay time in different regions of the human body is measured relative to the electrocardiogram (ECG) signal. Also the flow velocity of a liquid suspension containing particles the size of erythrocytes (equivalent to blood flow) is measured. Registered signals are stored after digitalization and preprocessed using LabView for a Windows environment. The described device has the application of the self-mixing method and highlights significant advantages of simplicity, compactness, and robustness as well as the self-aligning and self-detecting abilities of such method, compared with the use of conventional interferometric method.

journal_name

J Biomed Opt

authors

Meigas K,Hinrikus H,Kattai R,Lass J

doi

10.1117/1.1528949

subject

Has Abstract

pub_date

2003-01-01 00:00:00

pages

152-60

issue

1

eissn

1083-3668

issn

1560-2281

journal_volume

8

pub_type

杂志文章
  • Voxel-based measurement sensitivity of spatially resolved near-infrared spectroscopy in layered tissues.

    abstract::We quantitatively investigated the measurement sensitivity of spatially resolved spectroscopy (SRS) across six tissue models: cerebral tissue, a small animal brain, the forehead of a fetus, an adult brain, forearm muscle, and thigh muscle. The optical path length in the voxel of the model was analyzed using Monte Carl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.3.030503

    authors: Niwayama M

    更新日期:2018-03-01 00:00:00

  • Surgical lighting with contrast enhancement based on spectral reflectance comparison and entropy analysis.

    abstract::Surgical light is important for helping the surgeon easily identify specific tissues during an operation. We propose a spectral reflectance comparison model to optimize the light-emitting diode light spectrum in the operating room. An entropy evaluation method, meant specifically for surgical situations, was developed...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.10.105012

    authors: Shen J,Wang H,Wu Y,Li A,Chen C,Zheng Z

    更新日期:2015-10-01 00:00:00

  • Differentiation of cancer cells in two-dimensional and three-dimensional breast cancer models by Raman spectroscopy.

    abstract::We demonstrate the first application of Raman spectroscopy in diagnosing nonmalignant, premalignant, malignant, and metastatic stages of breast cancer in a three-dimensional (3-D) cell culture model that closely mimics an in vivo environment. Comprehensive study comparing classification in two-dimensional (2-D) and 3-...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.11.117008

    authors: Damayanti NP,Fang Y,Parikh MR,Craig AP,Kirshner J,Irudayaraj J

    更新日期:2013-11-01 00:00:00

  • Descriptive parameters of the erythrocyte aggregation phenomenon using a laser transmission optical chip.

    abstract::The study of red blood cell (RBC) aggregation is of great interest because of its implications for human health. Altered RBC aggregation can lead to microcirculatory problems as in vascular pathologies, such as hypertension and diabetes, due to a decrease in the erythrocyte surface electric charge and an increase in t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.1.017003

    authors: Toderi MA,Castellini HV,Riquelme BD

    更新日期:2017-01-01 00:00:00

  • Inexpensive diffuse reflectance spectroscopy system for measuring changes in tissue optical properties.

    abstract::The measurement of changes in blood volume in tissue is important for monitoring the effects of a wide range of therapeutic interventions, from radiation therapy to skin-flap transplants. Many systems available for purchase are either expensive or difficult to use, limiting their utility in the clinical setting. A low...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.105005

    authors: Glennie DL,Hayward JE,McKee DE,Farrell TJ

    更新日期:2014-01-01 00:00:00

  • Near-infrared fluorescence goggle system with complementary metal-oxide-semiconductor imaging sensor and see-through display.

    abstract::We have developed a near-infrared (NIR) fluorescence goggle system based on the complementary metal-oxide-semiconductor active pixel sensor imaging and see-through display technologies. The fluorescence goggle system is a compact wearable intraoperative fluorescence imaging and display system that can guide surgery in...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.10.101303

    authors: Liu Y,Njuguna R,Matthews T,Akers WJ,Sudlow GP,Mondal S,Tang R,Gruev V,Achilefu S

    更新日期:2013-10-01 00:00:00

  • Toward optical guidance during endoscopic ultrasound-guided fine needle aspirations of pancreatic masses using single fiber reflectance spectroscopy: a feasibility study.

    abstract::Endoscopic ultrasound-guided fine needle aspirations (EUS-FNA) of pancreatic masses suffer from sample errors and low-negative predictive values. Fiber-optic spectroscopy in the visible to near-infrared wavelength spectrum can noninvasively extract physiological parameters from tissue and has the potential to guide th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.2.024001

    authors: Stegehuis PL,Boogerd LS,Inderson A,Veenendaal RA,van Gerven P,Bonsing BA,Sven Mieog J,Amelink A,Veselic M,Morreau H,van de Velde CJ,Lelieveldt BP,Dijkstra J,Robinson DJ,Vahrmeijer AL

    更新日期:2017-02-01 00:00:00

  • Application of fluorescence recovery after photobleaching to study prestin lateral mobility in the human embryonic kidney cell.

    abstract::The transmembrane protein prestin is crucial to outer hair cell (OHC) electromotility and contributes to the sensitivity and frequency selectivity of mammalian hearing. The molecular mechanisms of electromotility remain unclear, but prestin is purported to function as both a voltage sensor and a molecular motor. Under...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2715202

    authors: Organ LE,Raphael RM

    更新日期:2007-03-01 00:00:00

  • Measurement of drug and macromolecule diffusion across atherosclerotic rabbit aorta ex vivo by attenuated total reflection-Fourier transform infrared imaging.

    abstract::Diffusion of two model drugs-benzyl nicotinate and ibuprofen-and the plasma macromolecule albumin across atherosclerotic rabbit aorta was studied ex vivo by attenuated total reflection-Fourier transform infrared (ATR-FTIR) imaging. Solutions of these molecules were applied to the endothelial surface of histological se...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3174395

    authors: Palombo F,Danoux CB,Weinberg PD,Kazarian SG

    更新日期:2009-07-01 00:00:00

  • Real-time brightfield, darkfield, and phase contrast imaging in a light-emitting diode array microscope.

    abstract::We demonstrate a single-camera imaging system that can simultaneously acquire brightfield, darkfield, and phase contrast images in real time. Our method uses computational illumination via a programmable light-emitting diode (LED) array at the source plane, providing flexible patterning of illumination angles. Brightf...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.106002

    authors: Liu Z,Tian L,Liu S,Waller L

    更新日期:2014-01-01 00:00:00

  • Oral cancer screening: serum Raman spectroscopic approach.

    abstract::Serum Raman spectroscopy (RS) has previously shown potential in oral cancer diagnosis and recurrence prediction. To evaluate the potential of serum RS in oral cancer screening, premalignant and cancer-specific detection was explored in the present study using 328 subjects belonging to healthy controls, premalignant, d...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.11.115006

    authors: Sahu AK,Dhoot S,Singh A,Sawant SS,Nandakumar N,Talathi-Desai S,Garud M,Pagare S,Srivastava S,Nair S,Chaturvedi P,Murali Krishna C

    更新日期:2015-11-01 00:00:00

  • Performance assessment of time-domain optical brain imagers, part 2: nEUROPt protocol.

    abstract::The nEUROPt protocol is one of two new protocols developed within the European project nEUROPt to characterize the performances of time-domain systems for optical imaging of the brain. It was applied in joint measurement campaigns to compare the various instruments and to assess the impact of technical improvements. T...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.8.086012

    authors: Wabnitz H,Jelzow A,Mazurenka M,Steinkellner O,Macdonald R,Milej D,Żołek N,Kacprzak M,Sawosz P,Maniewski R,Liebert A,Magazov S,Hebden J,Martelli F,Di Ninni P,Zaccanti G,Torricelli A,Contini D,Re R,Zucchelli L,Spine

    更新日期:2014-08-01 00:00:00

  • Optical waveguides formed by silver ion exchange in Schott SG11 glass for waveguide evanescent field fluorescence microscopy: evanescent images of HEK293 cells.

    abstract::Planar glass waveguides with a specific number of modes were fabricated by Ag(+)-Na(+) exchange in Schott SG11 glass. The effective refractive indices were determined using m-line spectroscopy in both s- and p-polarization. By using the reversed Wentzel-Kramers-Brillouin approximation, the index profiles were describe...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3443796

    authors: Hassanzadeh A,Nitsche M,Armstrong S,Nabavi N,Harrison R,Dixon SJ,Langbein U,Mittler S

    更新日期:2010-05-01 00:00:00

  • New pediatric vision screener employing polarization-modulated, retinal-birefringence-scanning-based strabismus detection and bull's eye focus detection with an improved target system: opto-mechanical design and operation.

    abstract::Amblyopia ("lazy eye") is a major public health problem, caused by misalignment of the eyes (strabismus) or defocus. If detected early in childhood, there is an excellent response to therapy, yet most children are detected too late to be treated effectively. Commercially available vision screening devices that test fo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.6.067004

    authors: Irsch K,Gramatikov BI,Wu YK,Guyton DL

    更新日期:2014-06-01 00:00:00

  • Fiber optic biosensor for the detection of C-reactive protein and the study of protein binding kinetics.

    abstract::Application of a fiber optic biosensor (FOB) to the real-time investigation of the interaction kinetics between FITC-conjugated monoclonal sheep anti-human C-reactive protein (CRP) antibody and CRP isoforms on the surface of optical fiber is described. Recently, both the native pentameric CRP (pCRP), an acute phase pr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714029

    authors: Chou C,Hsu HY,Wu HT,Tseng KY,Chiou A,Yu CJ,Lee ZY,Chan TS

    更新日期:2007-03-01 00:00:00

  • Proposed method for internal electron therapy based on high-intensity laser acceleration.

    abstract::Radiotherapy is one of the main methods to treat cancer. However, due to the propagation pattern of high-energy photons in tissue and their inability to discriminate between healthy and malignant tissues, healthy tissues may also be damaged, causing undesired side effects. A possible method for internal electron thera...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.5.051041

    authors: Tepper M,Barkai U,Gannot I

    更新日期:2015-05-01 00:00:00

  • Multiphoton fluorescence lifetime imaging of chemotherapy distribution in solid tumors.

    abstract::Doxorubicin is a commonly used chemotherapeutic employed to treat multiple human cancers, including numerous sarcomas and carcinomas. Furthermore, doxorubicin possesses strong fluorescent properties that make it an ideal reagent for modeling drug delivery by examining its distribution in cells and tissues. However, wh...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.11.116010

    authors: Carlson M,Watson AL,Anderson L,Largaespada DA,Provenzano PP

    更新日期:2017-11-01 00:00:00

  • Sensing dynamic cytoplasm refractive index changes of adherent cells with quantitative phase microscopy using incorporated microspheres as optical probes.

    abstract::The intracellular refractive index is an important parameter that describes the optical density of the cytoplasm and the concentration of the intracellular solutes. The refractive index of adherently grown cells is difficult to access. We present a method in which silica microspheres in living cells are used to determ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.9.097001

    authors: Przibilla S,Dartmann S,Vollmer A,Ketelhut S,Greve B,von Bally G,Kemper B

    更新日期:2012-09-01 00:00:00

  • Modulation of an optical needle's reflectivity alters the average photon path through scattering media.

    abstract::We introduce the concept of deliberate placement of absorbers to alter the average path of photons through tissue for a biomedical optical device. By changing the reflectivity of a needle that separates a source and detector, the average photon path through a turbid medium can be changed. Totally reflective needles ha...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2168167

    authors: Simonson P,D'Amico E,Gratton E

    更新日期:2006-01-01 00:00:00

  • Optical coherence tomography today: speed, contrast, and multimodality.

    abstract::In the last 25 years, optical coherence tomography (OCT) has advanced to be one of the most innovative and most successful translational optical imaging techniques, achieving substantial economic impact as well as clinical acceptance. This is largely owing to the resolution improvements by a factor of 10 to the submic...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.19.7.071412

    authors: Drexler W,Liu M,Kumar A,Kamali T,Unterhuber A,Leitgeb RA

    更新日期:2014-01-01 00:00:00

  • Filter-based method for background removal in high-sensitivity wide-field-surface-enhanced Raman scattering imaging in vivo.

    abstract::As molecular imaging moves towards lower detection limits, the elimination of endogenous background signals becomes imperative. We present a facile background-suppression technique that specifically segregates the signal from surface-enhanced Raman scattering (SERS)-active nanoparticles (NPs) from the tissue autofluor...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.076017

    authors: Mallia RJ,McVeigh PZ,Veilleux I,Wilson BC

    更新日期:2012-07-01 00:00:00

  • Macromolecular diffusion in the extracellular matrix measured by fluorescence correlation spectroscopy.

    abstract::Diffusion of therapeutic macromolecules through the extracellular matrix of tumor tissue is a crucial step in drug delivery. We use fluorescence correlation spectroscopy (FCS) to measure diffusion of IgG (150 kDa) and dextrans (155 kDa and 2 MDa) in solution, 5% gelatin hydrogel, and multicellular spheroids. Gel and s...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2982530

    authors: Reitan NK,Juthajan A,Lindmo T,de Lange Davies C

    更新日期:2008-09-01 00:00:00

  • Table top surface plasmon resonance measurement system for efficient urea biosensing using ZnO thin film matrix.

    abstract::The present report addresses the application of surface plasmon resonance (SPR) phenomenon for urea sensing. The former promises a high sensitivity, label-free detection, and real-time information by monitoring the refractive index change at the metal–dielectric interface. In the present report, a highly sensitive ure...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.8.087006

    authors: Paliwal A,Tomar M,Gupta V

    更新日期:2016-08-01 00:00:00

  • Tracer-cocktail injections for combined pre- and intraoperative multimodal imaging of lymph nodes in a spontaneous mouse prostate tumor model.

    abstract::To improve surgical guidance toward prostate draining lymph nodes, we investigate the potential of intraoperative fluorescence imaging and combined pre- and intraoperative multimodality imaging approaches. Transgenic adenocarcinoma mouse prostate mice with spontaneous prostate tumors are injected intratumorally with: ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3528027

    authors: van Leeuwen AC,Buckle T,Bendle G,Vermeeren L,Valdés Olmos R,van de Poel HG,van Leeuwen FW

    更新日期:2011-01-01 00:00:00

  • Two-photon microscopy and spectroscopy based on a compact confocal scanning head.

    abstract::We have combined a confocal laser scanning head modified for TPE (two-photon excitation) microscopy with some spectroscopic modules to study single molecules and molecular aggregates. The behavior of the TPE microscope unit has been characterized by means of point spread function measurements and of the demonstration ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.1382809

    authors: Diaspro A,Chirico G,Federici F,Cannone F,Beretta S,Robello M

    更新日期:2001-07-01 00:00:00

  • Optical redox imaging indices discriminate human breast cancer from normal tissues.

    abstract::Our long-term goal was to investigate the potential of incorporating redox imaging technique as a breast cancer (BC) diagnosis component to increase the positive predictive value of suspicious imaging finding and to reduce unnecessary biopsies and overdiagnosis. We previously found that precancer and cancer tissues in...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.11.114003

    authors: Xu HN,Tchou J,Feng M,Zhao H,Li LZ

    更新日期:2016-11-01 00:00:00

  • Classifying structural alterations of the cytoskeleton by spectrum enhancement and descriptor fusion.

    abstract::A classifier capable of ranking structural alterations of the cytoskeleton is developed. Images of cytoskeletal microtubules obtained from the epifluorescence microscopy of primary culture rat hepatocytes are analyzed. Morphological descriptors are extracted by contour and mass fractal analysis, direct methods, and sp...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2187423

    authors: Crosta GF,Urani C,Fumarola L

    更新日期:2006-03-01 00:00:00

  • Perfusion assessment in rat spinal cord tissue using photoplethysmography and laser Doppler flux measurements.

    abstract::Animal models are widely used to investigate the pathological mechanisms of spinal cord injury (SCI), most commonly in rats. It is well known that compromised blood flow caused by mechanical disruption of the vasculature can produce irreversible damage and cell death in hypoperfused tissue regions and spinal cord tiss...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.037005

    authors: Phillips JP,Cibert-Goton V,Langford RM,Shortland PJ

    更新日期:2013-03-01 00:00:00

  • Polarization birefringence measurements for characterizing the myocardium, including healthy, infarcted, and stem-cell-regenerated tissues.

    abstract::Myocardial infarction leads to structural remodeling of the myocardium, in particular to the loss of cardiomyocytes due to necrosis and an increase in collagen with scar formation. Stem cell regenerative treatments have been shown to alter this remodeling process, resulting in improved cardiac function. As healthy myo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3469844

    authors: Wood MF,Ghosh N,Wallenburg MA,Li SH,Weisel RD,Wilson BC,Li RK,Vitkin IA

    更新日期:2010-07-01 00:00:00

  • Measurement of ocular anterior segment dimension and wavefront aberration simultaneously during accommodation.

    abstract::In order to understand the relationship between accommodation and vision quality, a custom-built ultra-long scan depth spectral domain optical coherence tomography (UL-SDOCT) and a Shack-Hartmann wavefront sensor (HSWFS) were combined. The resolution and scan depth of UL-SDOCT are 6 μm and 15.6 mm, respectively, which...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.17.12.120501

    authors: Shi G,Wang Y,Yuan Y,Wei L,Lv F,Zhang Y

    更新日期:2012-12-01 00:00:00