Abstract:
SIGNIFICANCE:Detailed biochemical and morphological imaging of the plaque burdened coronary arteries holds the promise of improved understanding of atherosclerosis plaque development, ultimately leading to better diagnostics and therapies. AIM:Development of a dual-modality intravascular catheter supporting swept-source optical coherence tomography (OCT) and frequency-domain fluorescence lifetime imaging (FD-FLIM) of endogenous fluorophores with UV excitation. APPROACH:We instituted a refined approach to endoscope development that combines simulation in a commercial ray tracing program, fabrication, and a measurement method for optimizing ball-lens performance. With this approach, we designed and developed a dual-modality catheter endoscope based on a double-clad fiber supporting OCT through the core and fluorescence collection through the first cladding. We varied the relative percent of UV excitation launched into the core and first cladding to explore the potential resolution improvement for FD-FLIM. The developed catheter endoscope was optically characterized, including measurement of spatial resolution and fluorescent lifetimes of standard fluorophores. Finally, the system was demonstrated on fresh ex vivo human coronary arteries. RESULTS:The developed endoscope was shown to have optical performance similar to predictions derived from the simulation approach. The FLIM resolution can be improved by over a factor of 4 by primarily illuminating through the core rather than the first cladding. However, time-dependent solarization losses need to be considered when choosing the relative percentage. We ultimately chose to illuminate with 7% of the power transmitting through the core. The resulting catheter endoscope had 40-μm lateral resolution for OCT and <100 μm lateral resolution for FD-FLIM. Images of ex vivo coronary arteries are consistent with expectations based on histopathology. CONCLUSIONS:The results demonstrate that our approach for endoscope simulation produces reliable predictions of endoscope performance. Simulation results guided our development of a multimodal OCT/FD-FLIM catheter imaging system for investigating atherosclerosis in coronary arteries.
journal_name
J Biomed Optjournal_title
Journal of biomedical opticsauthors
Chen X,Kim W,Serafino M,Tan Z,Jo J,Applegate Bdoi
10.1117/1.JBO.25.9.096010subject
Has Abstractpub_date
2020-09-01 00:00:00issue
9eissn
1083-3668issn
1560-2281pii
JBO-200151Rjournal_volume
25pub_type
杂志文章abstract::The earliest steps of breast cancer begin with aberrations in mammary ductal structure. Techniques that enable an investigator to image in situ and then analyze the same tissue using biochemical tools facilitates identification of genetic networks and signaling pathways active in the imaged structure. Cellular confoca...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2065827
更新日期:2005-09-01 00:00:00
abstract::We have built an all-solid-state camera that is directly modulated at the pixel level for frequency-domain fluorescence lifetime imaging microscopy (FLIM) measurements. This novel camera eliminates the need for an image intensifier through the use of an application-specific charge coupled device design in a frequency-...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.jbo.17.12.126020
更新日期:2012-12-01 00:00:00
abstract::An integrated miniature multi-modal microscope (4M device) for microendoscopy was built and tested. Imaging performance is evaluated and imaging results are presented for both fluorescence and reflectance samples. Images of biological samples show successful imaging of both thin layers of fixed cells prepared on a sli...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2978060
更新日期:2008-09-01 00:00:00
abstract::The effect of glucose on fluorescence of synthesized ZnCdS nanoparticles in the presence of glucose oxidase or in a mixture of glucose oxidase and peroxidase has been investigated. Behavior of fluorescence characteristics of ZnCdS nanoparticles with nonstabilized surface and coated with polymer shell is compared. It h...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.19.1.011020
更新日期:2014-01-01 00:00:00
abstract::High-speed (video-rate) fluorescence lifetime imaging (FLIM) through a flexible endoscope is reported based on gated optical image intensifier technology. The optimization and potential application of FLIM to tissue autofluorescence for clinical applications are discussed. ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2102807
更新日期:2005-09-01 00:00:00
abstract::Optical technique based on diffuse reflectance measurement combined with indocyanine green (ICG) bolus tracking is extensively tested as a method for clinical assessment of brain perfusion in adults at the bedside. Methodology of multiwavelength and time-resolved detection of fluorescence light excited in the ICG is p...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.17.8.087001
更新日期:2012-08-01 00:00:00
abstract::A simple empirical method is presented to determine the scattering coefficient mu' s from backscattered polarized images of turbid media. It uses the ratio, pixel by pixel, of two images that are the second and the first backscattered Stokes parameter images Q and I, respectively. Taking this image ratio, then integra...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1924715
更新日期:2005-05-01 00:00:00
abstract::The metabolic rate of oxygen consumption, an important indicator of tissue metabolism, can be expressed as the change of net blood oxygen flux into and out of a tissue region per 100 g of tissue. In this work, we propose a photoacoustic and Doppler ultrasound method for imaging local blood oxygen flux of a single vess...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.17.3.036012
更新日期:2012-03-01 00:00:00
abstract::Mid-IR semiconductor lasers of two wavelength bands, 5.4 and 9.6 microm, are applied to measure aqueous glucose concentration ranging from 0 to 500 mgdL with Intralipid emulsion (0 to 8%) added as a fat simulator. The absorption coefficient micro(a) is found linear with respect to glucose and Intralipid concentrations...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2714283
更新日期:2007-03-01 00:00:00
abstract:SIGNIFICANCE:Despite the importance of the cell membrane in regulation of drug activity, the influence of drug treatments on its physical properties is still poorly understood. The combination of fluorescence lifetime imaging microscopy (FLIM) with specific viscosity-sensitive fluorescent molecular rotors allows the qu...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.25.12.126004
更新日期:2020-12-01 00:00:00
abstract::To improve surgical guidance toward prostate draining lymph nodes, we investigate the potential of intraoperative fluorescence imaging and combined pre- and intraoperative multimodality imaging approaches. Transgenic adenocarcinoma mouse prostate mice with spontaneous prostate tumors are injected intratumorally with: ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3528027
更新日期:2011-01-01 00:00:00
abstract::Optical clearing is a well-known phenomenon. It is based on the matching of refractive indices of a bulk material and scattering particles. The same principle is also used in scattering-based optical measurements of different constituents, such as glucose. By registering changes in scattering, it is possible to evalua...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2904957
更新日期:2008-03-01 00:00:00
abstract::This paper explains the term low-coherence interferometry, reviews the early development of optical low-coherence reflectometry, and shows some of the paths that led to the field of biomedical optics. This paper demonstrates that early technical developments in the telecommunications industry resulted in a myriad of t...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.429914
更新日期:1999-04-01 00:00:00
abstract::Optical coherence tomography (OCT) provides more parameters than pure morphology does. In a recent paper [A. Knuettel and M. Boehlau-Godau, J. Biomed. Opt. 5(1) 83-92 (2000)] we have shown that the refractive index (RI) can be evaluated in a localized manner in skin tissue under in vivo conditions. Based on a theory, ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1647544
更新日期:2004-03-01 00:00:00
abstract::Three major analytical tools in imaging science are summarized and demonstrated relative to optical imaging in vivo. Standard resolution testing is optimal when infinite contrast is used and hardware evaluation is the goal. However, deep tissue imaging of absorption or fluorescent contrast agents in vivo often present...
journal_title:Journal of biomedical optics
pub_type: 杂志文章,评审
doi:10.1117/1.2209908
更新日期:2006-05-01 00:00:00
abstract::The results of an experimental study of the possibilities of monitoring erbium yttrium aluminum garnet laser-mediated ablation of human epidermis with the use of Fourier transform infrared (FTIR) spectroscopy and spectral polarization techniques are presented. The attenuated total reflection (ATR) method was used for ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1755719
更新日期:2004-07-01 00:00:00
abstract::Intrauterine photoacoustic and ultrasound imaging are probe-based imaging modalities with translational potential for use in detecting endometrial diseases. This deep-tissue imaging probe design allows for the retrofitting of commercially available endometrial sampling curettes. The imaging probe presented here has a ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.23.4.046008
更新日期:2018-04-01 00:00:00
abstract::Planar glass waveguides with a specific number of modes were fabricated by Ag(+)-Na(+) exchange in Schott SG11 glass. The effective refractive indices were determined using m-line spectroscopy in both s- and p-polarization. By using the reversed Wentzel-Kramers-Brillouin approximation, the index profiles were describe...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3443796
更新日期:2010-05-01 00:00:00
abstract::In order to evaluate the impact of anatomy on the spectral properties of oral tissue, we used reflectance and fluorescence spectroscopy to characterize nine different anatomic sites. All spectra were collected in vivo from healthy oral mucosa. We analyzed 710 spectra collected from the oral cavity of 79 healthy volunt...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2992139
更新日期:2008-11-01 00:00:00
abstract:SIGNIFICANCE:Visible light optical coherence tomography (OCT) is emerging for spectroscopic and ultrahigh resolution imaging, but challenges remain. Depth-dependent dispersion limits retinal image quality and current correction approaches are cumbersome. Inconsistent group refractive indices during image reconstruction...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.25.9.090501
更新日期:2020-09-01 00:00:00
abstract::The reflection and transmission of coherent light from a biological system can yield information about its condition. In the case of blood exposed to the air, there is a change in the properties of the speckle patterns observed in the coagulation process. This can be studied by means of the rate of temporal variation,...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.24.3.031018
更新日期:2018-12-01 00:00:00
abstract::We describe the protocol for an inexpensive and nondestructive optical reflectance assay for the measurement of biofilm formation. Reflectance data are obtained using an Ocean Optics (Dunedin, Florida) USB 2000 spectrometer with a polychromatic light source. A fiber optic cable is used both for illumination and collec...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1953347
更新日期:2005-07-01 00:00:00
abstract::Image correlation spectroscopy (ICS) is a powerful technique for detecting arrangement of fluorophores in images. This tutorial gives background into the mathematical underpinnings of ICS, specifically image autocorrelation. The effects of various artifacts and image processing steps, including background subtraction,...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.17.8.080801
更新日期:2012-08-01 00:00:00
abstract::In laser retinal photocoagulation, short (<20 ms) pulses have been found to reduce thermal damage to the inner retina, decrease treatment time, and minimize pain. However, the safe therapeutic window (defined as the ratio of power for producing a rupture to that of mild coagulation) decreases with shorter exposures. T...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3130282
更新日期:2009-05-01 00:00:00
abstract::Motion artifacts are the most significant sources of noise in the context of pediatric brain imaging designs and data analyses, especially in applications of functional near-infrared spectroscopy (fNIRS), in which it can completely affect the quality of the data acquired. Different methods have been developed to corre...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.12.126003
更新日期:2015-01-01 00:00:00
abstract::Hemorrhagic hypovolemia and inotropic agent administration were used to manipulate cardiac output (CO) and oxygen delivery in rabbits to investigate the correlation between noninvasive frequency domain photon migration (FDPM) spectroscopy and invasive hemodynamic monitoring parameters. Frequency-domain photon migratio...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1427046
更新日期:2002-01-01 00:00:00
abstract::The specificity of the hemodynamic response function (HRF) is determined spatially by the vascular architecture and temporally by the evolution of hemodynamic changes. Here, we used functional photoacoustic microscopy (fPAM) to investigate single cerebral blood vessels of rats after left forepaw stimulation. In this s...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.17.6.061210
更新日期:2012-06-01 00:00:00
abstract::A reflectance volume holographic imaging (VHI) endoscope has been designed for simultaneous in vivo imaging of surface and subsurface tissue structures. Prior utilization of VHI systems has been limited to ex vivo tissue imaging. The VHI system presented in this work is designed for laparoscopic use. It consists of a ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.22.5.056010
更新日期:2017-05-01 00:00:00
abstract::A classifier capable of ranking structural alterations of the cytoskeleton is developed. Images of cytoskeletal microtubules obtained from the epifluorescence microscopy of primary culture rat hepatocytes are analyzed. Morphological descriptors are extracted by contour and mass fractal analysis, direct methods, and sp...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2187423
更新日期:2006-03-01 00:00:00
abstract::In order to diagnose cancer, a sample must be removed, prepared, and examined under a microscope, which is expensive, invasive, and time consuming. Fiber optic fluorescence endomicroscopy, where an image guide is used to obtain high-resolution images of tissue in vivo, has shown promise as an alternative to convention...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.9.096003
更新日期:2013-09-01 00:00:00