Abstract:
:The reflection and transmission of coherent light from a biological system can yield information about its condition. In the case of blood exposed to the air, there is a change in the properties of the speckle patterns observed in the coagulation process. This can be studied by means of the rate of temporal variation, the contrast, and also the fractality of patterns. The fractality of the speckle pattern can be investigated by a fractal dimension, which can quantify a level of the complexity of platelet aggregation structure and a fibrin network formed in the process of blood coagulation. In addition, dynamic characteristics of a movement in blood also contain information on the progress of the coagulation process. Fractality and dynamic characteristics are investigated simultaneously for speckle patterns observed in the coagulation process of stored horse blood. Experimental results show the feasibility of the proposed method for detecting hemolysis and formation of platelet aggregation structure and the fibrin network during the coagulation process.
journal_name
J Biomed Optjournal_title
Journal of biomedical opticsauthors
Yokoi N,Aizu Y,Uozumi Jdoi
10.1117/1.JBO.24.3.031018keywords:
["blood coagulation","fractal dimension","image processing","speckle imaging"]subject
Has Abstractpub_date
2018-12-01 00:00:00pages
1-7issue
3eissn
1083-3668issn
1560-2281pii
JBO-180393SSRjournal_volume
24pub_type
杂志文章abstract::Coherent anti-Stokes Raman scattering (CARS) microscopy is used to determine the distribution and concentration of selected compounds in intact human hair. By generating images based on ratiometric CARS contrast, quantitative concentration maps of both water and externally applied d-glycine are produced in the cortex ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3184444
更新日期:2009-07-01 00:00:00
abstract::This work reviews our research during the past several years on time-resolved (TR) near-infrared diffuse optical tomography (DOT). Following an introduction of the measuring modes, two proposed schemes of image reconstruction in TR-DOT are described: one utilizes the full TR data, and the other, referred to as the mod...
journal_title:Journal of biomedical optics
pub_type: 杂志文章,评审
doi:10.1117/1.2815724
更新日期:2007-11-01 00:00:00
abstract::In the last decade, coherent anti-Stokes Raman scattering (CARS) microscopy has emerged as a powerful multiphoton imaging technique offering label-free chemical sensitivity and high three-dimensional resolution. However, its widespread application in the life sciences has been hampered by the use of costly pulsed lase...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.6.066004
更新日期:2013-06-01 00:00:00
abstract::Protoporphyrin IX (PpIX)-encapsulated mesoporous silica nanoparticles were synthesized, characterized, and utilized for photodynamic therapy (PDT) of cancer. Silica encapsulation is relatively transparent for activated light and can protect the PpIX against denaturation induced by the extreme bioenvironment. The mesop...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3083427
更新日期:2009-01-01 00:00:00
abstract::Oxygen plays a very important role in living cells. The intracellular level of oxygen is under tight control, as even a small deviation from normal oxygen level affects major cellular metabolic processes and is likely to result in cellular damage or cell death. This paper describes the use of the oxygen sensitive fluo...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1344190
更新日期:2001-04-01 00:00:00
abstract::We demonstrate the utility of functional near-infrared spectroscopy (fNIRS) as a tool for physicians to study cortical plasticity in children with cerebral palsy (CP). Motor cortex activation patterns were studied in five healthy children and five children with CP (8.4+/-2.3 years old in both groups) performing a fing...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3432746
更新日期:2010-05-01 00:00:00
abstract::Current diagnostic capabilities and limitations of fluorescence endomicroscopy in the cervix are assessed by qualitative and quantitative image analysis. Four cervical tissue types are investigated: normal columnar epithelium, normal and precancerous squamous epithelium, and stromal tissue. This study focuses on the p...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.12.126011
更新日期:2016-12-01 00:00:00
abstract::The erratum notes a correction to Fig. 5 for the published article. ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章,已发布勘误
doi:10.1117/1.JBO.25.4.049803
更新日期:2020-04-01 00:00:00
abstract::Treatment of deep venous thrombosis (DVT)--a primary cause of potentially fatal pulmonary embolism (PE)--depends on the age of the thrombus. The existing clinical imaging methods are capable of visualizing a thrombus but cannot determine the age of the blood clot. Therefore, there is a need for an imaging technique to...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2992175
更新日期:2008-09-01 00:00:00
abstract::Fluorescence spectroscopy has been widely investigated as a technique for identifying pathological tissue; however, unrelated subject-to-subject variations in spectra complicate data analysis and interpretation. We describe and evaluate a new biosensing technique, differential laser-induced perturbation spectroscopy (...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.17.6.067002
更新日期:2012-06-01 00:00:00
abstract::Flow imaging is an important technique in a range of disease areas, but estimating low flow speeds, especially near the walls of blood vessels, remains challenging. Pulsed photoacoustic flow imaging can be an alternative since there is little signal contamination from background tissue with photoacoustic imaging. We p...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.2.026004
更新日期:2016-02-01 00:00:00
abstract::Using commercially available organic fluorophores, the current applications of Förster (fluorescence) resonance energy transfer (FRET) are limited to about 80 Å. However, many essential activities in cells are spatially and/or temporally dependent on the assembly/disassembly of transient complexes consisting of large-...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.17.1.011006
更新日期:2012-01-01 00:00:00
abstract::It is widely known that not all of the treated cells survive after introduction of exogenous molecules via any physical method. Therefore, it is important to develop methods that would allow simultaneous evaluation of both molecular delivery efficiency and cell viability. This study presents Förster resonance energy t...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.22.9.097001
更新日期:2017-09-01 00:00:00
abstract::Subsurface fluorescence molecular tomography (FMT) has promising potential for noninvasive characterization of molecular and cellular activities in small animals by tomographic means in reflectance geometry. In this work, subsurface FMT is employed to monitor the therapeutic response of cisplatin in tumor-bearing mice...
journal_title:Journal of biomedical optics
pub_type: 信件
doi:10.1117/1.JBO.17.4.040504
更新日期:2012-04-01 00:00:00
abstract::We report a photonic approach for selective inactivation of viruses with a near-infrared subpicosecond laser. We demonstrate that this method can selectively inactivate viral particles ranging from nonpathogenic viruses such as the M13 bacteriophage and the tobacco mosaic virus to pathogenic viruses such as the human ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3275477
更新日期:2009-11-01 00:00:00
abstract::We introduce the concept of deliberate placement of absorbers to alter the average path of photons through tissue for a biomedical optical device. By changing the reflectivity of a needle that separates a source and detector, the average photon path through a turbid medium can be changed. Totally reflective needles ha...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2168167
更新日期:2006-01-01 00:00:00
abstract::We present a method for tissue fluorescence quantification in situ using a handheld fiber optic probe that measures both the fluorescence and diffuse reflectance spectra. A simplified method to decouple the fluorescence spectrum from distorting effects of the tissue optical absorption and scattering is developed, with...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3523616
更新日期:2010-11-01 00:00:00
abstract::We present a novel confocal microscope that has dual-axis architecture and biaxial postobjective scanning for the collection of fluorescence images from biological specimens. This design uses two low-numerical-aperture lenses to achieve high axial resolution and long working distance, and the scanning mirror located d...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1760760
更新日期:2004-07-01 00:00:00
abstract::An autofluorescence lifetime wide-field imaging system that can generate contrast in underlying tissue structures of normal and malignant brain tissue samples with video rate acquisition and processing time is presented. Images of the investigated tissues were acquired with high resolution (∼35 μm) using an algorithm ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.6.060504
更新日期:2013-06-01 00:00:00
abstract::A stable optical system is required to acquire a high-quality image. A motionless lensless setup is designated to obtain high-resolution and large field of view images. The sample is sequentially illuminated with multiple random phase patterns, and the recorded images are subtracted from the system calibration images ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.22.11.110502
更新日期:2017-11-01 00:00:00
abstract::Functional near-infrared spectroscopy (fNIRS), acquired simultaneously with electroencephalography (EEG), allows the investigation of hemodynamic brain responses to epileptic activity. Because the presumed epileptogenic focus is patient-specific, an appropriate source/detector (SD) montage has to be reconfigured for e...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.19.2.026010
更新日期:2014-02-01 00:00:00
abstract::Laser-induced breakdown spectroscopy (LIBS) is applied to analyze human fingernails using nanosecond laser pulses. Measurements on 45 nail samples are carried out and 14 key species are identified. The elements detected with the present system are: Al, C, Ca, Fe, H, K, Mg, N, Na, O, Si, Sr, Ti as well as CN molecule. ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3574757
更新日期:2011-05-01 00:00:00
abstract::Pelvic organ prolapse (POP) occurs when changes to the pelvic organ support structures cause descent or herniation of the pelvic organs into the vagina. Clinical evaluation of POP is a series of manual measurements known as the pelvic organ prolapse quantification (POP-Q) score. However, it fails to identify the mecha...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.12.127008
更新日期:2016-12-01 00:00:00
abstract::We have used an adaptive optics confocal scanning laser ophthalmoscope to assess oxygen saturation in small retinal vessels. Images of the vessels with a diameter smaller than 50 μm are recorded at oxygen sensitive and isosbestic wavelengths (680 and 796 nm, respectively). The vessel optical densities (ODs) are determ...
journal_title:Journal of biomedical optics
pub_type: 信件
doi:10.1117/1.3655354
更新日期:2011-11-01 00:00:00
abstract::We describe the implementation and use of an adaptive optics loop in the imaging path of a commercial wide field microscope. We show that it is possible to maintain the optical performances of the original microscope when imaging through aberrant biological samples. The sources used for illuminating the adaptive optic...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3603847
更新日期:2011-07-01 00:00:00
abstract::Our aim is the development of a simple optical method for pulse wave profile, pulse wave delay time, and blood flow measurement. The method is based on recording the Doppler frequency shift related to a moving target--blood vessel walls or small particles. The Doppler signal is detected using the self-mixing that occu...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1528949
更新日期:2003-01-01 00:00:00
abstract::To improve surgical guidance toward prostate draining lymph nodes, we investigate the potential of intraoperative fluorescence imaging and combined pre- and intraoperative multimodality imaging approaches. Transgenic adenocarcinoma mouse prostate mice with spontaneous prostate tumors are injected intratumorally with: ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3528027
更新日期:2011-01-01 00:00:00
abstract::We report noninvasive, in vivo optical imaging deep within a mouse brain by swept-source optical coherence tomography (SS-OCT), enabled by a 1.3-μm vertical cavity surface emitting laser (VCSEL). VCSEL SS-OCT offers a constant signal sensitivity of 105 dB throughout an entire depth of 4.25 mm in air, ensuring an exten...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.10.106004
更新日期:2015-10-01 00:00:00
abstract::Previous studies suggest that altered corneal temperature may be a feature of schizophrenia, but the association between major depressive disorder (MDD) and corneal temperature has yet to be assessed. The aim of this study is to investigate whether eye temperature is different among MDD patients than among healthy ind...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.2.026001
更新日期:2016-02-01 00:00:00
abstract::The feasibility of spatial frequency domain imaging (SFDI) for breast surgical margin assessment was evaluated in tissue-simulating phantoms and in fully intact lumpectomy specimens at the time of surgery. Phantom data was evaluated according to contrast-detail resolution, quantitative accuracy and model-data goodness...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.3.036012
更新日期:2013-03-01 00:00:00